Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 103
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Sensors (Basel) ; 21(13)2021 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-34283107

RESUMEN

The most common imaging technique for dental diagnoses and treatment monitoring is X-ray imaging, which evolved from the first intraoral radiographs to high-quality three-dimensional (3D) Cone Beam Computed Tomography (CBCT). Other imaging techniques have shown potential, such as Optical Coherence Tomography (OCT). We have recently reported on the boundaries of these two types of techniques, regarding. the dental fields where each one is more appropriate or where they should be both used. The aim of the present study is to explore the unique capabilities of the OCT technique to optimize X-ray units imaging (i.e., in terms of image resolution, radiation dose, or contrast). Two types of commercially available and widely used X-ray units are considered. To adjust their parameters, a protocol is developed to employ OCT images of dental conditions that are documented on high (i.e., less than 10 µm) resolution OCT images (both B-scans/cross sections and 3D reconstructions) but are hardly identified on the 200 to 75 µm resolution panoramic or CBCT radiographs. The optimized calibration of the X-ray unit includes choosing appropriate values for the anode voltage and current intensity of the X-ray tube, as well as the patient's positioning, in order to reach the highest possible X-rays resolution at a radiation dose that is safe for the patient. The optimization protocol is developed in vitro on OCT images of extracted teeth and is further applied in vivo for each type of dental investigation. Optimized radiographic results are compared with un-optimized previously performed radiographs. Also, we show that OCT can permit a rigorous comparison between two (types of) X-ray units. In conclusion, high-quality dental images are possible using low radiation doses if an optimized protocol, developed using OCT, is applied for each type of dental investigation. Also, there are situations when the X-ray technology has drawbacks for dental diagnosis or treatment assessment. In such situations, OCT proves capable to provide qualitative images.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Tomografía de Coherencia Óptica , Odontología , Humanos , Imagenología Tridimensional , Fantasmas de Imagen , Rayos X
2.
Opt Express ; 26(17): 21831-21842, 2018 Aug 20.
Artículo en Inglés | MEDLINE | ID: mdl-30130886

RESUMEN

This paper demonstrates that the complex master slave interferometry (CMSI) method used in spectral domain interferometry (SDI) can efficiently be used for accurate refractive index and group velocity dispersion measurements of optically transparent samples. For the first time, we demonstrate the relevance of the phase information delivered by CMSI for dispersion evaluations with no need to linearize data. The technique proposed here has been used to accurately measure the group refractive index and the group velocity dispersion of a strong dispersive sample (SF6 glass), and a weak dispersive one (distilled water). The robustness of the technique is demonstrated through the manipulation of several sets of experimental data.

3.
Skin Res Technol ; 24(2): 265-273, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29143429

RESUMEN

BACKGROUND: Optical coherence tomography (OCT) of skin delivers three-dimensional images of tissue microstructures. Although OCT imaging offers a promising high-resolution modality, OCT images suffer from some artifacts that lead to misinterpretation of tissue structures. Therefore, an overview of methods to mitigate artifacts in OCT imaging of the skin is of paramount importance. Speckle, intensity decay, and blurring are three major artifacts in OCT images. Speckle is due to the low coherent light source used in the configuration of OCT. Intensity decay is a deterioration of light with respect to depth, and blurring is the consequence of deficiencies of optical components. METHOD: Two speckle reduction methods (one based on artificial neural network and one based on spatial compounding), an attenuation compensation algorithm (based on Beer-Lambert law) and a deblurring procedure (using deconvolution), are described. Moreover, optical properties extraction algorithm based on extended Huygens-Fresnel (EHF) principle to obtain some additional information from OCT images are discussed. RESULTS: In this short overview, we summarize some of the image enhancement algorithms for OCT images which address the abovementioned artifacts. The results showed a significant improvement in the visibility of the clinically relevant features in the images. The quality improvement was evaluated using several numerical assessment measures. CONCLUSION: Clinical dermatologists benefit from using these image enhancement algorithms to improve OCT diagnosis and essentially function as a noninvasive optical biopsy.


Asunto(s)
Enfermedades de la Piel/diagnóstico por imagen , Piel/diagnóstico por imagen , Algoritmos , Artefactos , Diseño de Equipo , Humanos , Redes Neurales de la Computación , Dispersión de Radiación , Tomografía de Coherencia Óptica/instrumentación , Tomografía de Coherencia Óptica/métodos
4.
Opt Express ; 25(13): 14533-14544, 2017 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-28789039

RESUMEN

The paper presents a proof-of-concept polarization-sensitive swept source optical coherence tomography (OCT) system that performs measurements of the retardance as well as of the axis orientation of a linear birefringent sample. The system performs single input state polarization-sensitive OCT and employs an optical module based on optically passive elements such as two beam displacers and a Faraday rotator. Our implementation of the PS-OCT system does not need any calibration step to compensate for the polarimetric effect of the fibers, and its operation does not require a balanced polarization-diversity detector. The optical module allows measurement of the two polarization properties of the sample via two measurements which are performed simultaneously.

5.
Opt Lett ; 42(22): 4744-4747, 2017 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-29140358

RESUMEN

In this Letter, we investigate the possibility of using a commercially available Q-switch-pumped supercontinuum (QS-SC) source, operating in the kilohertz regime, for ultra-high resolution optical coherence tomography (UHR-OCT) in the 1300 nm region. The QS-SC source proves to be more intrinsically stable from pulse to pulse than a mode-locked-based SC (ML-SC) source while, at the same time, is less expensive. However, its pumping rate is lower than that used in ML-SC sources. Therefore, we investigate here specific conditions to make such a source usable for OCT. We compare images acquired with the QS-SC source and with a current state-of-the-art SC source used for imaging. We show that comparable visual contrast obtained with the two technologies is achievable by increasing the readout time of the camera to include a sufficient number of QS-SC pulses.

6.
Appl Opt ; 56(12): 3378-3382, 2017 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-28430264

RESUMEN

In this paper we investigate a phase-correction method for compensation of the nonlinearity of conventional wavelength-swept laser sources based on a fiber Fabry-Perot tunable filter as a wavelength selective element. A triangular waveform signal is commonly used to drive the filter. We, however, extract the zero crossings from the interferograms and modify the shape of the triangular signal accordingly. This algorithm was tested for different values of the optical path length difference in the interferometer setup. Significant compensation for the nonlinearity of the filter was obtained.

7.
Opt Express ; 24(3): 2885-904, 2016 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-26906857

RESUMEN

A general theoretical model is developed to improve the novel Spectral Domain Interferometry method denoted as Master/Slave (MS) Interferometry. In this model, two functions, g and h are introduced to describe the modulation chirp of the channeled spectrum signal due to nonlinearities in the decoding process from wavenumber to time and due to dispersion in the interferometer. The utilization of these two functions brings two major improvements to previous implementations of the MS method. A first improvement consists in reducing the number of channeled spectra necessary to be collected at Master stage. In previous MSI implementation, the number of channeled spectra at the Master stage equated the number of depths where information was selected from at the Slave stage. The paper demonstrates that two experimental channeled spectra only acquired at Master stage suffice to produce A-scans from any number of resolved depths at the Slave stage. A second improvement is the utilization of complex signal processing. Previous MSI implementations discarded the phase. Complex processing of the electrical signal determined by the channeled spectrum allows phase processing that opens several novel avenues. A first consequence of such signal processing is reduction in the random component of the phase without affecting the axial resolution. In previous MSI implementations, phase instabilities were reduced by an average over the wavenumber that led to reduction in the axial resolution.

8.
Opt Lett ; 41(12): 2743-6, 2016 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-27304278

RESUMEN

We report the usefulness of a single all-fiber-based supercontinuum (SC) source for combined photoacoustic microscopy (PAM) and optical coherence tomography (OCT). The SC light is generated by a tapered photonic crystal fiber pumped by a nanosecond pulsed master oscillator power amplifier at 1064 nm. The spectrum is split into a shorter wavelength band (500-800 nm) for single/multi-spectral PAM and a longer wavelength band (800-900 nm) band for OCT. In vivo mouse ear imaging was achieved with an integrated dual-modality system. We further demonstrated its potential for spectroscopic photoacoustic imaging by doing multispectral measurements on retinal pigment epithelium and blood samples with 15-nm linewidth.

9.
Appl Opt ; 55(21): 5707-14, 2016 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-27463927

RESUMEN

A broadband supercontinuum light source with an acousto-optic tunable filter (AOTF) are used to characterize dispersion in two time-domain OCT systems, at 850 and 1300 nm. The filter is designed to sweep across two spectral ranges, which are restricted here from 800 to 900 nm and from 1200 to 1500 nm, respectively. Dispersion compensation for 850 nm was achieved with a spectral delay line. Dispersion compensation for 1300 nm was achieved using BK 7 rod glasses in the reference arm. The AOTF allows evaluation of dispersion in under as well as overcompensated systems. The AOTF method is based on wavelength dependence of the optical path difference corresponding to the maximum strength of the interference signal recorded using a mirror as object. Comparison is made between the AOTF method and the more usual method based on measurement of the full width at half-maximum of the autocorrelation peak. This comparison shows that the AOTF method is more accurate in terms of evaluation of the dispersion left uncompensated after each adjustment. The AOTF method additionally provides information on the direction of dispersion compensation.

10.
Appl Opt ; 55(26): 7378-86, 2016 Sep 10.
Artículo en Inglés | MEDLINE | ID: mdl-27661377

RESUMEN

Optical coherence tomography (OCT) is fast emerging as an additional non-interventional modality for skin tumor detection and diagnosis. A master/slave flying spot OCT configuration was assembled to detect periocular basal cell carcinomas (BCC). A swept source at 1300 nm and sweeping speed of 50 kHz were used. A three-step process was involved. First, 384 channeled spectra using a mirror were stored for 384 optical path differences at the master stage. Then, the stored channeled spectra (masks) were correlated with the channeled spectrum from the BCC tissue to produce 384 en face OCT images (200×200 pixels) for the optical path difference values used to acquire the masks. Finally, these en face slices were stacked to form a volume to cross-reference BCC tumor margins in the orthogonal plane. Per each eyelid sample, several en face images of 200×200 lateral pixels are produced in the time to scan laterally a complete raster of 1.6 s. Combination of the en face views with the cross-sectioning views allow for better discrimination of BCCs comparable to using cross-sectional imaging alone, as previously reported using the conventional fast-Fourier-transform-based OCT techniques.


Asunto(s)
Carcinoma Basocelular/diagnóstico por imagen , Neoplasias de los Párpados/diagnóstico , Neoplasias Cutáneas/diagnóstico por imagen , Tomografía de Coherencia Óptica/métodos , Análisis de Fourier , Humanos
11.
Opt Express ; 23(18): 23768-86, 2015 Sep 07.
Artículo en Inglés | MEDLINE | ID: mdl-26368471

RESUMEN

A new set-up is proposed to measure the full polarimetric properties of a sample through an optical fiber, paving the way to full-Mueller endoscopic imaging. The technique combines a channeled spectrum polarimeter and an interferometer. This permits high-speed measurement of two Mueller matrices simultaneously. The first matrix characterizes only the fiber while the second characterizes both fiber and sample. The instrument is validated on vacuum, a quarter-wave plate and a linear polarizer for single-point measurements. Insensitivity of the polarimetric measurement to fiber disturbances is proven while manipulating the fiber.

12.
Opt Express ; 23(11): 14148-61, 2015 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-26072783

RESUMEN

A theoretical model is developed for the Master/Slave interferometry (MSI) that is used to demonstrate its tolerance to dispersion left uncompensated in the interferometer when evaluating distances and thicknesses. In order to prove experimentally its tolerance to dispersion, different lengths of optical fiber are inserted into the interferometer to introduce dispersion. It is demonstrated that the sensitivity profile versus optical path difference is not affected by the length of fiber left uncompensated. It is also demonstrated that the axial resolution is constant within the axial range, close to the expected theoretical resolution determined by the optical source bandwidth. Then the thickness of a glass plate is measured several times in the presence of dispersion and errors in measurements are evaluated using the MSI method and the conventional Fourier transformation (FT) based method using linearized/calibrated data. The standard deviation for thickness results obtained with the MSI is more than 5 times smaller than the standard deviation for results delivered by the conventional, FT based method.

13.
Opt Lett ; 40(7): 1322-5, 2015 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-25831323

RESUMEN

A fast dual-mode-locked akinetic optical swept source in the 1550-nm wavelength band is presented that is tested up to a sweep rate of 797 KHz. It comprises a voltage-controlled oscillator-driven wideband semiconductor optical amplifier (SOA) along with a dispersion compensation fiber, in a ring laser configuration. A Faraday rotating mirror is employed in the cavity as a reflective element in order to achieve better polarization control. By driving the SOA at a high-MHz-frequency value multiple of the resonant frequency f(R), equal to the inverse round trip time, a first-mode locking mechanism is imposed. A second locking mechanism consists in sweeping the radio frequency of the locking signal at a rate slightly detuned from f(R). A dynamic linewidth of 0.8 nm is assessed by measuring the decay of interference signal strength versus optical path difference in a Mach-Zehnder interferometer.

14.
Opt Lett ; 40(16): 3858-61, 2015 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-26274678

RESUMEN

This Letter presents a spectral-domain, polarization-sensitive optical coherence tomography (PS-OCT) system, where the light collection from the two arms of the interferometer is performed exclusively using single-mode fibers and couplers, and the two orthogonal polarization components are sequentially detected by a single line camera. Retardance measurements can be affected by polarimetric effects because of fiber birefringence and diattenuation in fiber couplers. This configuration bypasses such issues by performing polarization selection before the collection fiber through the combination of a polarization rotator and a linear polarizer. Retardance calibration is achieved with a Berek compensator. Similar net retardance maps of a birefringent phantom are obtained for two different settings of induced fiber birefringence, effectively demonstrating the tolerance of the configuration to fiber-based disturbances.


Asunto(s)
Fibras Ópticas , Tomografía de Coherencia Óptica/instrumentación , Birrefringencia , Relación Señal-Ruido
15.
Opt Lett ; 40(17): 4014-7, 2015 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-26368700

RESUMEN

A configuration for Talbot bands is presented in which two tilted gratings replace the splitter normally used for recombining the signals from the two interferometer arms. The two optical beams from the interferometer are launched by two fiber leads tightly brought together in the front focal plane of a collimating lens. As the tips of the two fibers are slightly off-axis, the emergent beams after the collimating lens are not parallel. In combination with the two tilted gratings, the nonparallel launching of the two beams leads to a total elimination of mirror terms even when the two beams overlap on either grating. The effects of several geometrical parameters on the visibility performance versus optical path difference between the two arm lengths of the interferometer are evaluated.


Asunto(s)
Interferometría/instrumentación , Fibras Ópticas , Fenómenos Ópticos
16.
Opt Lett ; 39(3): 450-3, 2014 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-24487837

RESUMEN

We report on a novel method to produce B-scan images in spectral domain optical coherence tomography (SD-OCT). The method proceeds in two steps. In the first step, using a mirror in the sample arm of the interferometer, channelled spectra are acquired for different values of the optical path difference (OPD) and stored as masks. In the second step, the mirror is replaced with an object and the captured channelled spectrum is correlated with each mask, providing the interference strength from the OPD value used to collect the respective mask. Such a procedure does not require data organized in equal frequency slots, and therefore there is no need for resampling as practiced in the conventional fast Fourier transform (FFT)-based SD-OCT technology. We show that the sensitivity drop-off versus OPD and the quality of B-scan images of the novel method are similar to those obtained in the conventional FFT-based SD-OCT, using spectral data linearly organized in frequency.


Asunto(s)
Tomografía de Coherencia Óptica/métodos , Calibración , Análisis de Fourier
17.
Appl Opt ; 53(26): 5912-6, 2014 Sep 10.
Artículo en Inglés | MEDLINE | ID: mdl-25321671

RESUMEN

We demonstrate the capability of optical coherence tomography (OCT) to perform topography of metallic surfaces after being subjected to ductile or brittle fracturing. Two steel samples, OL 37 and OL 52, and an antifriction Sn-Sb-Cu alloy were analyzed. Using an in-house-built swept source OCT system, height profiles were generated for the surfaces of the two samples. Based on such profiles, it can be concluded that the first two samples were subjected to ductile fracture, while the third one was subjected to brittle fracture. The OCT potential for assessing the surface state of materials after fracture was evaluated by comparing OCT images with images generated using an established method for such investigations, scanning electron microscopy (SEM). Analysis of cause of fracture is essential in response to damage of machinery parts during various accidents. Currently the analysis is performed using SEM, on samples removed from the metallic parts, while OCT would allow in situ imaging using mobile units. To the best of our knowledge, this is the first time that the OCT capability to replace SEM has been demonstrated. SEM is a more costly and time-consuming method to use in the investigation of surfaces of microstructures of metallic materials.

18.
Opt Express ; 21(16): 19324-38, 2013 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-23938849

RESUMEN

Conventional spectral domain interferometry (SDI) methods suffer from the need of data linearization. When applied to optical coherence tomography (OCT), conventional SDI methods are limited in their 3D capability, as they cannot deliver direct en-face cuts. Here we introduce a novel SDI method, which eliminates these disadvantages. We denote this method as Master - Slave Interferometry (MSI), because a signal is acquired by a slave interferometer for an optical path difference (OPD) value determined by a master interferometer. The MSI method radically changes the main building block of an SDI sensor and of a spectral domain OCT set-up. The serially provided signal in conventional technology is replaced by multiple signals, a signal for each OPD point in the object investigated. This opens novel avenues in parallel sensing and in parallelization of signal processing in 3D-OCT, with applications in high- resolution medical imaging and microscopy investigation of biosamples. Eliminating the need of linearization leads to lower cost OCT systems and opens potential avenues in increasing the speed of production of en-face OCT images in comparison with conventional SDI.


Asunto(s)
Imagenología Tridimensional/métodos , Interferometría/métodos , Tomografía de Coherencia Óptica/métodos , Análisis de Fourier , Humanos , Nervio Óptico/anatomía & histología , Pulgar/anatomía & histología , Factores de Tiempo
19.
Opt Express ; 21(2): 1925-36, 2013 Jan 28.
Artículo en Inglés | MEDLINE | ID: mdl-23389175

RESUMEN

We present a novel low-coherence interferometer configuration, equipped with acousto-optic deflectors that can be used to simultaneously acquire up to eight time domain optical coherence tomography en-face images. The capabilities of the configuration are evaluated in terms of depth resolution, signal to noise ratio and crosstalk. Then the configuration is employed to demonstrate simultaneous en-face optical coherence tomography imaging at five different depths in a specimen of armadillidium vulgare.


Asunto(s)
Aumento de la Imagen/instrumentación , Imagenología Tridimensional/instrumentación , Lentes , Iluminación/instrumentación , Tomografía de Coherencia Óptica/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo
20.
Appl Opt ; 52(29): 7054-61, 2013 Oct 10.
Artículo en Inglés | MEDLINE | ID: mdl-24217720

RESUMEN

Virtual tissues (phantoms) are widely used for performance evaluation of imaging systems. Specific design of the phantom is necessary for the correct assessment of a system's parameters. In an effort to reduce the amount of time and energy spent making application-oriented phantoms, we describe procedures to make epoxy-resin solid phantoms based on Mie scattering theory, with two different scatterers: polystyrene and gold microspheres. The phantoms are specifically designed to be used in two applications: (a) the gold microspheres solid phantoms are used to estimate the point-spread function (PSF) of an optical coherence tomography (OCT) system, and (b) the polystyrene solid phantom are used to evaluate the performance of an OCT-images optical properties extraction (OPE) algorithm. Phantoms with differing combination of materials have been tested to achieve the most suitable combination for producing an accurate PSF for application (a) and a valid evaluation/parameter optimization of the algorithm in application (b). An en face time-domain dynamic focus OCT is used for imaging.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA