Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Circulation ; 146(5): 383-397, 2022 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-35722876

RESUMEN

BACKGROUND: Cerebral microbleeds (CMBs) have been observed in healthy elderly people undergoing systematic brain magnetic resonance imaging. The potential role of acute triggers on the appearance of CMBs remains unknown. We aimed to describe the incidence of new CMBs after transcatheter aortic valve replacement (TAVR) and to identify clinical and procedural factors associated with new CMBs including hemostatic measures and anticoagulation management. METHODS: We evaluated a prospective cohort of patients with symptomatic aortic stenosis referred for TAVR for CMBs (METHYSTROKE [Identification of Epigenetic Risk Factors for Ischemic Complication During the TAVR Procedure in the Elderly]). Standardized neurologic assessment, brain magnetic resonance imaging, and analysis of hemostatic measures including von Willebrand factor were performed before and after TAVR. Numbers and location of microbleeds on preprocedural magnetic resonance imaging and of new microbleeds on postprocedural magnetic resonance imaging were reported by 2 independent neuroradiologists blinded to clinical data. Measures associated with new microbleeds and postprocedural outcome including neurologic functional outcome at 6 months were also examined. RESULTS: A total of 84 patients (47% men, 80.9±5.7 years of age) were included. On preprocedural magnetic resonance imaging, 22 patients (26% [95% CI, 17%-37%]) had at least 1 microbleed. After TAVR, new microbleeds were observed in 19 (23% [95% CI, 14%-33%]) patients. The occurrence of new microbleeds was independent of the presence of microbleeds at baseline and of diffusion-weighted imaging hypersignals. In univariable analysis, a previous history of bleeding (P=0.01), a higher total dose of heparin (P=0.02), a prolonged procedure (P=0.03), absence of protamine reversion (P=0.04), higher final activated partial thromboplastin time (P=0.05), lower final von Willebrand factor high-molecular-weight:multimer ratio (P=0.007), and lower final closure time with adenosine-diphosphate (P=0.02) were associated with the occurrence of new postprocedural microbleeds. In multivariable analysis, a prolonged procedure (odds ratio, 1.22 [95% CI, 1.03-1.73] for every 5 minutes of fluoroscopy time; P=0.02) and postprocedural acquired von Willebrand factor defect (odds ratio, 1.42 [95% CI, 1.08-1.89] for every lower 0.1 unit of high-molecular-weight:multimer ratio; P=0.004) were independently associated with the occurrence of new postprocedural microbleeds. New CMBs were not associated with changes in neurologic functional outcome or quality of life at 6 months. CONCLUSIONS: One out of 4 patients undergoing TAVR has CMBs before the procedure and 1 out of 4 patients develops new CMBs. Procedural or antithrombotic management and persistence of acquired von Willebrand factor defect were associated with the occurrence of new CMBs. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT02972008.


Asunto(s)
Hemorragia Cerebral , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Hemorragia Cerebral/diagnóstico por imagen , Hemorragia Cerebral/epidemiología , Hemorragia Cerebral/etiología , Femenino , Fluoroscopía , Hemostáticos , Humanos , Imagen por Resonancia Magnética , Masculino , Estudios Prospectivos , Calidad de Vida , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Factor de von Willebrand
2.
Cardiol Young ; 33(12): 2685-2689, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37877253

RESUMEN

The aetiology of cyanosis could be unclear in children, even for specialised paediatricians. Two cases were reported: first, a 6-year-old child with features of left isomerism and Fallot was fortuitously diagnosed with anomalous hepatic venous drainage before complete repair. Second, a newborn with an antenatal diagnosis of ductus venosus agenesis had an isolated intermittent right-to-left atrial shunt when upright, with favourable outcome, in contrast to the association with significant heart malformations including inferior caval vein interruption. Multimodality imaging and 3D printing helped to rule out extracardiac causes of persistent cyanosis and plan surgical repair.


Asunto(s)
Síndrome de Heterotaxia , Venas Pulmonares , Malformaciones Vasculares , Niño , Recién Nacido , Humanos , Femenino , Embarazo , Síndrome de Platipnea Ortodesoxia , Cianosis/diagnóstico , Cianosis/etiología , Síndrome de Heterotaxia/complicaciones , Disnea/complicaciones , Venas Pulmonares/anomalías , Malformaciones Vasculares/complicaciones
3.
Circulation ; 143(10): 1043-1061, 2021 03 09.
Artículo en Inglés | MEDLINE | ID: mdl-33683945

RESUMEN

After 15 years of successive randomized, controlled trials, indications for transcatheter aortic valve replacement (TAVR) are rapidly expanding. In the coming years, this procedure could become the first line treatment for patients with a symptomatic severe aortic stenosis and a tricuspid aortic valve anatomy. However, randomized, controlled trials have excluded bicuspid aortic valve (BAV), which is the most frequent congenital heart disease occurring in 1% to 2% of the total population and representing at least 25% of patients 80 years of age or older referred for aortic valve replacement. The use of a less invasive transcatheter therapy in this elderly population became rapidly attractive, and approximately 10% of patients currently undergoing TAVR have a BAV. The U.S. Food and Drug Administration and the "European Conformity" have approved TAVR for low-risk patients regardless of the aortic valve anatomy whereas international guidelines recommend surgical replacement in BAV populations. Given this progressive expansion of TAVR toward younger and lower-risk patients, heart teams are encountering BAV patients more frequently, while the ability of this therapy to treat such a challenging anatomy remains uncertain. This review will address the singularity of BAV anatomy and associated technical challenges for the TAVR procedure. We will examine and summarize available clinical evidence and highlight critical knowledge gaps regarding TAVR utilization in BAV patients. We will provide a comprehensive overview of the role of computed tomography scans in the diagnosis, and classification of BAV and TAVR procedure planning. Overall, we will offer an integrated framework for understanding the current role of TAVR in the treatment of bicuspid aortic stenosis and for guiding physicians in clinical decision-making.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino
4.
J Vasc Surg ; 75(3): 1021-1029.e2, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34923068

RESUMEN

OBJECTIVE: We evaluated whether a combination of intraoperative contrast-enhanced cone beam computed tomography (ceCBCT) and postoperative contrast-enhanced ultrasound (CEUS) after infrarenal endovascular abdominal aortic aneurysm repair (EVAR) could reduce late stent graft-related complications and, consequently, reintervention. METHODS: All consecutive patients who had received infrarenal bifurcated stent grafts in our hybrid room (IGS 730; GE Healthcare, Île-de-France, France) during two discrete periods were included in the present study. From November 2012 to September 2013, two-dimensional completion angiography was performed after each EVAR, followed by computed tomography angiography (CTA) before discharge (group 1). From October 2013 to January 2015, intraoperative ceCBCT was performed, followed by CEUS within the first postoperative days (group 2). Comparative analyses of the outcomes were performed. The primary endpoint was late stent graft-related complications, a composite factor incorporating aneurysm-related death, type I or III endoleaks, kink or occlusion of the iliac limb, and aortic sac enlargement after the first 30 postoperative days. The secondary endpoint was all stent graft-related reinterventions. All-cause and aneurysm-related deaths were also recorded. RESULTS: Overall, 100 consecutive patients (50 each in groups 1 and 2) were enrolled, with a median follow-up of 60 months (interquartile range, 41-69 months). At 60 months after the index procedure, the freedom from late stent graft-related complications in each group was 61.6% (95% confidence interval [CI], 47.0%-80.6%) for group 1 and 81.7% (95% CI, 70.1%-95.2%) for group 2 (P = .033). The use of intraoperative ceCBCT was independently associated with a reduced rate of late stent graft-related complications on multivariate analysis (hazard ratio, 0.39; 95% CI, 0.16-0.95; P = .038) but did not appear to significantly protect against stent graft-related reinterventions (hazard ratio, 0.53; 95% CI, 0.20-1.39; P = .198) or all-cause death (P = .47). CONCLUSIONS: To the best of our knowledge, the present study is the first to report the influence of routine ceCBCT on late outcomes after EVAR. The use of ceCBCT shows the potential for reducing late stent graft-related complications associated.


Asunto(s)
Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/cirugía , Aortografía , Implantación de Prótesis Vascular , Tomografía Computarizada de Haz Cónico , Procedimientos Endovasculares , Cuidados Intraoperatorios , Anciano , Anciano de 80 o más Años , Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/mortalidad , Prótesis Vascular , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/mortalidad , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/mortalidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/prevención & control , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Stents , Factores de Tiempo , Resultado del Tratamiento , Ultrasonografía
5.
J Card Surg ; 37(9): 2564-2570, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35726653

RESUMEN

BACKGROUND AND AIM OF THE STUDY: To evaluate whether the simplified valve-sparing technique (SVST) implies clinical outcomes comparable or not with those of established David technique in the surgery of aortic root. METHODS: We collected the records of patients who had undergone aortic root surgery with the SVST or standard David technique (SDT) at our institution between January 2009 and December 2018. The primary endpoints were the incidence of all-cause death, reoperation for any reason, and postoperative complications. The secondary endpoint was the midterm incidence of reoperation for aortic valve regurgitation. RESULTS: A total of 169 patients who underwent aortic root surgery were analyzed. SDT and SVST were performed in 48 (28.4%) and in 121 (71.6%) patients, respectively. Thirty-day mortality occurred in 0% and 0.8% of patients in the SDT and SVST groups, respectively. The rate of postoperative new permanent pacemaker implantation was 6.3% (three patients) and 0.8% (one patient) in SDT and SVST cohort, respectively (p = .07). The incidence of postoperative thromboembolic stroke was 6.3% and 2.5% in SDT and SVST groups, respectively (p = .23). The median follow-up time was 29 (23-47) months. During the FU period, no differences were found between two cohorts in terms of all-cause mortality (p = .99), the incidence of reoperation (p = .19), and incidence of aortic valve regurgitation requiring reoperation (p = .58). CONCLUSIONS: The SVST appears to be safe and feasible showing early clinical results comparable to the SDT. Nevertheless, further studies with larger series and long-term follow-ups are required to demonstrate its safety and efficacy.


Asunto(s)
Aneurisma de la Aorta , Insuficiencia de la Válvula Aórtica , Implantación de Prótesis Vascular , Aneurisma de la Aorta/cirugía , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/cirugía , Implantación de Prótesis Vascular/métodos , Estudios de Factibilidad , Humanos , Reoperación , Estudios Retrospectivos , Resultado del Tratamiento
6.
BMC Pulm Med ; 21(1): 401, 2021 Dec 06.
Artículo en Inglés | MEDLINE | ID: mdl-34872556

RESUMEN

INTRODUCTION: Association between sleep nocturnal breathing disorders and acute aortic syndrome (AAS) has been described but mid-term data are scarce. OBJECTIVES: We assessed the prognostic value of sleep apnea parameters and their relationship with aortic morphology after the onset of a type B AAS. METHODS: Between January 2010 and January 2018, sleep apnea screening in post type B AAS was prospectively performed. The association of sleep apnea parameters with aortic morphology and aortic expansion during follow-up was studied. RESULTS: Over the 8-year-study period, 103 patients were included, with a mean age of 57.8 ± 12.1 years old. Median follow-up was 25.0 months (11.0-51.0). Thirty-two patients (31%) required aortic stenting during the acute phase. In patients treated by aortic stenting, the descending thoracic aortic diameter was positively associated with a higher percentage of nocturnal time of saturation ≤ 90% after adjustment (p = 0.016). During follow-up, the nocturnal time of saturation ≤ 90% in patients treated by medical therapy was the only parameter associated with significant aortic expansion rate (r = 0.26, p = 0.04). Thirty-eight patients started and sustained nocturnal ventilation during follow-up. The association between aortic expansion rate and nocturnal time of saturation ≤ 90% did not persist during follow-up after adjustment on nocturnal ventilation initiation (r = 0.25, p = 0.056). CONCLUSIONS: Nocturnal hypoxemia parameters are positively associated with the max onset aortic diameter and significant aortic growth after type B AAS. Nocturnal ventilation seems to mitigate aortic expansion during follow-up.


Asunto(s)
Disección Aórtica/complicaciones , Disección Aórtica/patología , Hipoxia/complicaciones , Síndromes de la Apnea del Sueño/complicaciones , Adulto , Anciano , Disección Aórtica/cirugía , Femenino , Francia , Humanos , Hipoxia/terapia , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Prospectivos , Respiración Artificial/métodos , Síndromes de la Apnea del Sueño/terapia , Stents
7.
Eur Radiol ; 30(1): 609-619, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31372784

RESUMEN

OBJECTIVES: This study was conducted in order to evaluate the accuracy of a compressed sensing (CS) real-time single-breath-hold cine sequence for the assessment of left and right ventricular functional parameters in daily practice. METHODS: Cardiac magnetic resonance (CMR) cine images were acquired from 100 consecutive patients using both the reference segmented multi-breath-hold steady-state free precession (SSFP) acquisition and a prototype single-breath-hold real-time CS sequence, providing the same slice number, position, and thickness. For both sequences, the left (LV) and right ventricular (RV) ejection fractions (EF) and end-diastolic volumes (EDV) were assessed as well as LV mass (LVM). The visualization of wall-motion disorders (WMD) and signal void related to mitral or tricuspid regurgitation was also analyzed. RESULTS: The CS sequence mean scan time was 23 ± 6 versus 510 ± 109 s for the multi-breath-hold SSFP sequence (p < 0.001). There was an excellent correlation between the two sequences regarding mean LVEF (r = 0.995), LVEDV (r = 0.997), LVM (r = 0.981), RVEF (r = 0.979), and RVEDV (r = 0.983). Moreover, inter- and intraobserver agreements were very strong with intraclass correlations of 0.96 and 0.99, respectively. On CS images, mitral or tricuspid regurgitation visualization was good (AUC = 0.85 and 0.81, respectively; ROC curve analysis) and wall-motion disorder visualization was excellent (AUC ≥ 0.97). CONCLUSION: CS real-time single-breath-hold cine imaging reduces CMR scan duration by almost 20 times in daily practice while providing reliable measurements of both left and right ventricles. There was no clinically relevant information loss regarding valve regurgitation and wall-motion disorder depiction. KEY POINTS: • Compressed sensing single-breath-hold real-time cine imaging is a reliable sequence in daily practice. • Fast CS real-time imaging reduces CMR scan time and improves patient workflow. • There is no clinically relevant information loss with CS regarding heart valve regurgitation or wall-motion disorders.


Asunto(s)
Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Cinemagnética/métodos , Disfunción Ventricular/diagnóstico por imagen , Disfunción Ventricular/fisiopatología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Contencion de la Respiración , Femenino , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/patología , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Tamaño de los Órganos , Estudios Prospectivos , Curva ROC , Reproducibilidad de los Resultados , Volumen Sistólico , Disfunción Ventricular/patología , Adulto Joven
8.
Eur Radiol ; 29(6): 3027-3035, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30402702

RESUMEN

OBJECTIVE: To evaluate whether the epicardial adipose tissue (EAT) phenotype is associated with the electrophysiological properties of adjacent atrial myocardium in patients with atrial fibrillation (AF). METHODS: Between January and May 2017, 30 consecutive patients referred for a first AF catheter ablation were prospectively included. For each patient, a pre-procedural computed tomography scan was performed to assess total and left atrial (LA) EAT amount and radiodensity. A detailed point-by-point voltage mapping using an electroanatomic mapping system was realized to assess the presence of LA low-voltage zone (LVZ). RESULTS: Ten patients (33.3%) presented at least one LVZ. Older age (65 ± 7 vs. 58 ± 10 years, p = 0.05) was the only clinical parameter associated with LVZ. Despite no greater LA-EAT thickness by CT scan (3.0 [2.6-3.5] mm vs. 2.8 [2.2-3.1] mm, p = 0.354), patients with LA-LVZ presented significantly lower LA-EAT radiodensity than patients with no LA-LVZ (- 101.8 ± 12.5 HU vs. - 90.4 ± 6.3 HU, p = 0.004). No difference between total-EAT volume (131 ± 61 cm3 vs.107 ± 58 cm3, p = 0.361) and total-EAT radiodensity (- 106.8 ± 4.3 HU vs. - 102.4 ± 6.9 HU, p = 0.119) was found. CONCLUSION: Low LA-EAT radiodensity is associated with the presence of LVZ in patients with medical history of AF. KEY POINTS: • Cardiovascular risk factors are associated with low adipose tissue computed tomography attenuation. • Epicardial adipose tissue (EAT) has emerged as an important factor in the pathogenesis of metabolic-related cardiac diseases such as atrial fibrillation. • We showed that low left atrial EAT attenuation is associated with the presence of low-voltage zone, a surrogate for atrial fibrosis, within the adjacent myocardium.


Asunto(s)
Tejido Adiposo/patología , Fibrilación Atrial/diagnóstico , Mapeo del Potencial de Superficie Corporal/métodos , Atrios Cardíacos/diagnóstico por imagen , Pericardio/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Anciano , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Femenino , Estudios de Seguimiento , Atrios Cardíacos/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Factores de Riesgo
9.
MAGMA ; 31(1): 19-31, 2018 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-28550650

RESUMEN

OBJECTIVES: Our objectives were to evaluate a single-breath-hold approach for Cartesian 3-D CINE imaging of the left ventricle with a nearly isotropic resolution of [Formula: see text] and a breath-hold duration of [Formula: see text]19 s against a standard stack of 2-D CINE slices acquired in multiple breath-holds. Validation is performed with data sets from ten healthy volunteers. MATERIALS AND METHODS: A Cartesian sampling pattern based on the spiral phyllotaxis and a compressed sensing reconstruction method are proposed to allow 3-D CINE imaging with high acceleration factors. The fully integrated reconstruction uses multiple graphics processing units to speed up the reconstruction. The 2-D CINE and 3-D CINE are compared based on ventricular function parameters, contrast-to-noise ratio and edge sharpness measurements. RESULTS: Visual comparisons of corresponding short-axis slices of 2-D and 3-D CINE show an excellent match, while 3-D CINE also allows reformatting to other orientations. Ventricular function parameters do not significantly differ from values based on 2-D CINE imaging. Reconstruction times are below 4 min. CONCLUSION: We demonstrate single-breath-hold 3-D CINE imaging in volunteers and three example patient cases, which features fast reconstruction and allows reformatting to arbitrary orientations.


Asunto(s)
Técnicas de Imagen Cardíaca/métodos , Ventrículos Cardíacos/diagnóstico por imagen , Imagen por Resonancia Cinemagnética/métodos , Adulto , Anciano , Algoritmos , Contencion de la Respiración , Técnicas de Imagen Cardíaca/estadística & datos numéricos , Compresión de Datos , Femenino , Voluntarios Sanos , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Cinemagnética/estadística & datos numéricos , Masculino , Persona de Mediana Edad , Relación Señal-Ruido , Función Ventricular Izquierda , Adulto Joven
10.
Radiology ; 279(1): 297-305, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26583761

RESUMEN

PURPOSE: To evaluate the effect of iterative reconstruction on the depiction of systemic sclerosis-related interstitial lung disease (ILD) when the radiation dose is reduced by 60%. MATERIALS AND METHODS: This study was based on retrospective interpretation of prospectively acquired data over a 12-month period and approved by the institutional review board. The requirement to obtain informed consent was waived. Fifty-five chest computed tomographic (CT) examinations were performed in 38 women and 17 men (mean age, 55.8 years; range, 23-82 years) by using a dual-source CT unit with (a) both tubes set at similar energy (120 kVp) and (b) the total reference milliampere seconds (ie, 110 mAs) split up in a way that 40% was applied to tube A and 60% to tube B. Two series of images were generated simultaneously from the same dataset: (a) standard-dose images (generated from both tubes) reconstructed with filtered back projection (group 1, the reference standard) and (b) reduced-dose images (generated from tube A; 60% dose reduction) reconstructed with sinogram-affirmed iterative reconstruction (SAFIRE) (group 2). In both groups, the analyzed parameters comprised the image noise and the visualization and conspicuity of CT features of ILD. Two readers independently analyzed images from both groups. Results were compared by using the Wilcoxon test for paired samples; the 95% confidence interval was calculated when appropriate. RESULTS: The mean level of objective noise in group 2 was significantly lower than that in group 1 (22.02 HU vs 26.23 HU, respectively; P < .0001). The CT features of ILD in group 1 were always depicted in group 2, with subjective conspicuity scores (a) improved in group 2 for ground-glass opacity, reticulation, and bronchiectasis and/or bronchiolectasis and (b) identical in both groups for honeycombing. The interobserver agreement for their depiction was excellent in both groups (κ, 0.84-0.98). CONCLUSION: Despite a 60% dose reduction, images reconstructed with SAFIRE allowed similar detection of systematic sclerosis-related ILD compared with the reference standard.


Asunto(s)
Enfermedades Pulmonares Intersticiales/diagnóstico por imagen , Enfermedades Pulmonares Intersticiales/etiología , Esclerodermia Sistémica/complicaciones , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Estudios Retrospectivos
11.
Eur Radiol ; 25(4): 1182-9, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25636413

RESUMEN

PURPOSE: To evaluate the impact of iterative reconstruction on the detectability of clots. METHODS AND MATERIALS: Fifty-three patients were enrolled in a study comparing reduced-dose and full-dose images, available from the same dual-source data set. From each acquisition, three series of images were generated: (1) full-dose images (from both tubes), reconstructed with filtered back projection (FBP) (group 1; standard of reference), (2) reduced-dose images (from tube A only; 60 % dose reduction) reconstructed with FBP (group 2) and iterative reconstruction (SAFIRE) (group 3). RESULTS: In group 1 (mean DLP: 264.6 mGy.cm), (1) PE was diagnosed in 8 patients (15 %) with 82 clots in the central (n = 5), segmental (n = 39) and subsegmental (n = 38) arteries and (2) mean level of noise was 30.56 ± 5.07. In group 2 (mean DLP: 105.8 mGy.cm), a significant increase in noise (44.56 ± 6.24; p < 0.0001) (1) hampered detection of PE in one patient and (2) altered detection of peripheral clots (12 false-negative and 2 false-positive results). In group 3, image noise was not significantly different from that in group 1 (p = 0.1525; effect size: 0.2683), with a similar detection of PE compared to group 1 (p = 1). CONCLUSION: Reconstruction of reduced-dose images (60 % dose reduction) with SAFIRE provided image quality and diagnostic value comparable to those of full-dose FBP images. KEY POINTS: • Iterative reconstruction does not alter the detection of endoluminal clots. • Iterative reconstruction allows dose reduction in the context of acute PE. • Iterative reconstruction allows radiologists to approach the prospects of submilliSievert CT.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Embolia Pulmonar/diagnóstico por imagen , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Algoritmos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Arteria Pulmonar/diagnóstico por imagen , Reproducibilidad de los Resultados
12.
Semin Respir Crit Care Med ; 35(1): 64-73, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24481760

RESUMEN

Computed tomography (CT) is the core imaging modality for the evaluation of thoracic disorders. With the recently developed dual-energy CT (DECT) technique, the clinical utility of CT in the management of pulmonary diseases can be expanded. The most actively investigated principle of dual energy is material decomposition based on attenuation differences at different energy levels. This technique provides two key insights into lung physiology, that is, regional perfusion and ventilation. This functional information is obtained in addition to morphologic information because high-resolution thoracic anatomy is entirely preserved on dual-energy thoracic CT. The second major possibility offered by DECT is virtual monochromatic imaging that represents a new option for standard chest CT in daily routine. In this review, imaging principles and clinical applications of dual-energy thoracic CT are described. Knowledge of the applications of DECT may lead to wider use of this technique in the field of respiratory disorders.


Asunto(s)
Enfermedades Pulmonares/diagnóstico por imagen , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Tomografía Computarizada por Rayos X/métodos , Humanos , Pulmón/diagnóstico por imagen , Pulmón/fisiología , Enfermedades Torácicas/diagnóstico por imagen
13.
JACC Case Rep ; 29(10): 102319, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38633863

RESUMEN

Interventricular septum pellet retention after air-gunshot injury in a persistently asymptomatic patient is a rare, clinically significant occurrence. Management involved monitoring, echocardiography, and computed tomography scans. After risk-benefit analysis, we favored a nonsurgical management without prophylactic antibiotics or colchicine. No post-traumatic pericarditis was observed. Patient remained asymptomatic and in excellent condition at 1-month follow-up.

14.
J Cardiol Cases ; 29(3): 116-119, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38481646

RESUMEN

We report the case of a redo Ross surgery complicated by an ostial left circumflex occlusion requiring emergent percutaneous coronary intervention. The latter was complicated by coronary perforation treated by two covered stents with V-stenting technique. After immediate success, the clinical course was marked by acute stent thrombosis requiring emergent coronary bypass. Learning objectives: Ostial left circumflex perforation is a rare and potentially fatal complication that is challenging to manage. V stenting technique with two covered stents could be used as a life-saving procedure, but is associated with a high thrombotic risk.

15.
Radiology ; 267(1): 256-66, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23319663

RESUMEN

PURPOSE: To determine the energy levels that provide optimal imaging of thoracic circulation at dual-energy computed tomographic (CT) angiography with reduced iodine load in comparison with a standard technique. MATERIALS AND METHODS: The institutional review board approved the study with waiver of patient consent. Eighty patients underwent a dual-source, dual-energy CT examination after administration of low-concentration contrast material (170 mg of iodine per milliliter), and eight series of images were reconstructed, including the original polychromatic images at 80 and 140 kV and six series of virtual monochromatic spectral images at 50, 60, 70, 80, 90, and 100 keV. For each vascular compartment, the energy level that provided optimal evaluation on virtual monochromatic spectral images was determined, and these series were compared with the polychromatic dual-energy images and with standard chest CT images that were used as controls. Comparisons between groups were performed by using the paired Student t test for continuous variables and the McNemar test for categorical variables. Comparisons between dual-energy and standard CT images were performed by using the unpaired Student t test for continuous variables and the χ(2) test for categorical variables. RESULTS: For the aorta, pulmonary arteries, and veins, the reconstruction at 60 keV provided adequate attenuation without marked beam-hardening artifacts in 90% of patients, with the highest contrast-to-noise and signal-to-noise ratios, the lowest level of subjective noise, and no significant differences with images at 80 kV (mean energy, 54 keV). For the superior vena cava and brachiocephalic veins, the reconstructions at 100 keV enabled artifact-free analysis of the perivascular anatomic zone without a significant difference with images at 140 kV (mean energy, 92 keV). Compared with standard CT images acquired after administration of a 35% iodinated contrast agent, there was a statistically significant reduction in the frequency of artifacts around systemic veins at 100 keV (P < .001) and similar overall image quality for central vessels at 60 keV (P > .05). CONCLUSION: An optimal analysis of thoracic circulation can be achieved on virtual monochromatic spectral images at 60 keV and 100 keV and on the original polychromatic images at 80 kV and 140 kV. SUPPLEMENTAL MATERIAL: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.12120195/-/DC1.


Asunto(s)
Angiografía/métodos , Radiografía Torácica/métodos , Neoplasias Torácicas/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Distribución de Chi-Cuadrado , Medios de Contraste/administración & dosificación , Femenino , Estudios de Seguimiento , Humanos , Procesamiento de Imagen Asistido por Computador , Yohexol/administración & dosificación , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Neoplasias Torácicas/patología
16.
Radiology ; 267(2): 609-18, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23297336

RESUMEN

PURPOSE: To evaluate image quality of low-voltage chest computed tomographic (CT) angiography with raw data-based iterative reconstruction (sonogram-affirmed iterative reconstruction) in comparison with image quality of standard-dose standard-voltage filtered back projection (FBP) CT. MATERIALS AND METHODS: This prospective study was approved by the institutional review board, and the informed consent requirement was waived. Eighty consecutive patients who were referred for follow-up chest CT angiography underwent reduced-dose CT (hereafter, T2 examination) under technical conditions similar to those of the initial examination (hereafter, T1 examination), except the voltage selection was reduced by 20 kV with adaptation of the tube current to ensure a 50% reduction in CT dose index, and regular FBP was replaced by iterative reconstruction with sonogram-affirmed iterative reconstruction. The two techniques were compared by using paired tests (Student t test, Wilcoxon test, or McNemar test, according to the nature of variables). RESULTS: When compared with standard-dose T1 studies, reduced-dose T2 images showed: (a) significantly less objective noise at the level of the trachea on mediastinal and lung parenchymal images (P < .001) and no significant difference in objective noise at the level of the aorta on mediastinal images (P = .507); (b) significantly higher signal-to-noise and contrast-to-noise (P < .001) ratios; (c) similar visual perception of noise on mediastinal (P = .132) and lung (P = .366) images, mainly rated as moderate; and (d) similar overall subjective image quality (P = .405). CONCLUSION: Raw data-based iterative reconstruction yielded equivalent subjective and improved objective image quality of low-voltage half-dose CT angiograms compared with standard-dose FBP CT images for an average dose-length product of less than 80 mGy · cm in this population. SUPPLEMENTAL MATERIAL: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.12120414/-/DC1.


Asunto(s)
Angiografía/métodos , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Radiografía Torácica/métodos , Tomografía Computarizada por Rayos X/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Relación Señal-Ruido , Estadísticas no Paramétricas
17.
Diagn Interv Imaging ; 2023 Jun 14.
Artículo en Inglés | MEDLINE | ID: mdl-37328394

RESUMEN

PURPOSE: The purpose of this study was to compare a new free-breathing compressed sensing cine (FB-CS) cardiac magnetic resonance imaging (CMR) to the standard reference multi-breath-hold segmented cine (BH-SEG) CMR in an unselected population. MATERIALS AND METHODS: From January to April 2021, 52 consecutive adult patients who underwent both conventional BH-SEG CMR and new FB-CS CMR with fully automated respiratory motion correction were retrospectively enrolled. There were 29 men and 23 women with a mean age of 57.7 ± 18.9 (standard deviation [SD]) years (age range: 19.0-90.0 years) and a mean cardiac rate of 74.6 ± 17.9 (SD) bpm. For each patient, short-axis stacks were acquired with similar parameters providing a spatial resolution of 1.8 × 1.8 × 8.0 mm3 and 25 cardiac frames. Acquisition and reconstruction times, image quality (Likert scale from 1 to 4), left and right ventricular volumes and ejection fractions, left ventricular mass, and global circumferential strain were assessed for each sequence. RESULTS: FB-CS CMR acquisition time was significantly shorter (123.8 ± 28.4 [SD] s vs. 267.2 ± 39.3 [SD] s for BH-SEG CMR; P < 0.0001) at the penalty of a longer reconstruction time (271.4 ± 68.7 [SD] s vs. 9.9 ± 2.1 [SD] s for BH-SEG CMR; P < 0.0001). In patients without arrhythmia or dyspnea, FB-CS CMR provided subjective image quality that was not different from that of BH-SEG CMR (P = 0.13). FB-CS CMR improved image quality in patients with arrhythmia (n = 18; P = 0.002) or dyspnea (n = 7; P = 0.02), and the edge sharpness was improved at end-systole and end-diastole (P = 0.0001). No differences were observed between the two techniques in ventricular volumes and ejection fractions, left ventricular mass or global circumferential strain in patients in sinus rhythm or with cardiac arrhythmia. CONCLUSION: This new FB-CS CMR addresses respiratory motion and arrhythmia-related artifacts without compromising the reliability of ventricular functional assessment.

18.
Radiology ; 263(1): 253-9, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22332068

RESUMEN

PURPOSE: To evaluate the tolerance and level of enhancement achievable after inhalation of stable krypton. MATERIALS AND METHODS: This study was approved by the institutional review board and the local ethics committee. Written informed consent was obtained from all subjects. The study was planned as a Fleming two-stage design, enabling one to assess the effectiveness of a newer treatment or technique on a small number of patients. At the end of each stage, the results are computed, and the trial can be stopped if the effectiveness is less than a minimum success rate or greater than an expected success rate. After informed consent was obtained, a total of 32 patients (ie, two successive series of 16 patients each) with severe emphysema underwent a dual-source, dual-energy chest computed tomographic (CT) examination after inhalation of a mixture of stable krypton (80%) and oxygen (20%), with reconstruction of diagnostic and ventilation images. For each patient, two regions of interest were selected on a diagnostic image, one in a region of severe emphysema (presumed to be poorly ventilated or not ventilated) and a second one in a region devoid of structural abnormalities (presumed to be normally ventilated), with measurements of attenuation values on the corresponding ventilation image. RESULTS: All examinations were successfully performed, without adverse effects. Differences in attenuation between normal lung and emphysematous areas were found in 28 patients (88%; 95% confidence interval: 71%, 96.5%). The maximal level of attenuation within normal lung was 18.5 HU. Krypton attenuation difference between normal and emphysematous lung was significant, with a median value of 51.8% (P < .001). CONCLUSION: The level of enhancement after inhalation of krypton and its excellent clinical tolerance makes this gas eligible for ventilation CT examinations.


Asunto(s)
Criptón , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Interpretación de Imagen Radiográfica Asistida por Computador , Pruebas de Función Respiratoria , Estadísticas no Paramétricas
20.
Ann Cardiol Angeiol (Paris) ; 71(6): 413-416, 2022 Dec.
Artículo en Francés | MEDLINE | ID: mdl-36404521

RESUMEN

Both computed tomography (CT) angiography and vascular ultrasound have a major role before and during a transfemoral approach to TAVR. CT angiography will determine whether the patient is eligible for a femoral approach. Peri-procedural arterial ultrasound will be helpful to improve safety and optimize results during the femoral approach. Being able to interpret both of these imaging modalities is of paramount importance for any interventional cardiologist who practices structural interventions.


Asunto(s)
Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Arteria Femoral/diagnóstico por imagen , Extremidad Inferior , Angiografía por Tomografía Computarizada , Tomografía Computarizada por Rayos X/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA