Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Analyst ; 149(6): 1791-1798, 2024 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-38362752

RESUMEN

Forward scattering is an essential tool for investigating the colloidal suspension of polystyrene microspheres (PSMs). Evanescent wave coupled cavity ringdown spectroscopy (EW-CRDS) shows the anomalous extinction behavior in the limit of PSM particles that is much larger than the wavelength. EW-CRDS is a highly sensitive technique that improves weak absorption signals by enhancing the absorption path length, allowing for probing a range of processes at the solid/liquid interface by assessing the extinction properties. Additionally, it possesses the ability to sense a minimum absorbance of 1.2 × 10-6. EW-CRDS provides sufficient accuracy to detect correlation effects for PSMs in water at the interfacial region and their influence on forward scattering or extinction. In this work, we discuss the impact of volume fraction on the extinction of scatterers composed of microparticles in aqueous media. The findings of this study will contribute to a deeper understanding of the scattering dynamics in colloidal suspensions, with potential applications in various fields, including biology and metrology.

2.
Anal Chem ; 95(24): 9357-9365, 2023 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-37282542

RESUMEN

Insight into the aggregation kinetics of gold nanoparticles (GNPs) is critical for developing a colorimetric assay extensively used in chemical and biomolecular sensing. The aggregation of NPs plays a significant role in many natural and industrial processes, demanding comprehensive perceptions of the aggregation kinetics at a solid-liquid interface. However, the direct observation of the melamine-induced aggregation process of GNPs in the time-domain still remains a challenge. There is little to no information on the fundamental mechanisms of such kinetics using evanescent waves. Total internal reflection (TIR) has been applied to generate the evanescent field (EF), exploring aggregation kinetics near the solid-liquid interface. Here, we utilized a precise optical cavity-based method, an evanescent-wave coupled cavity ring-down spectroscopy (EW-CRDS), that can probe the melamine-induced aggregation kinetics of GNPs. The key feature of the present method is that the evanescent field generated by TIR illumination harnesses the power of CRDS to study 2D fractals via the collision and attachment of the GNPs and their melamine-induced aggregates at the interfacial region in real-time. This kinetic study reveals a critical point for diffusion-limited aggregation and provides insights into the design and optimization of colorimetric sensors that exploit the aggregation of GNPs. Furthermore, the EW-CRDS is a unique analytical approach that helps to deepen our understanding in probing the real-time aggregation process, detecting the presence of aggregator as compared to UV-vis and dynamic light scattering (DLS) spectroscopy.

3.
Anal Chem ; 94(18): 6689-6694, 2022 05 10.
Artículo en Inglés | MEDLINE | ID: mdl-35476390

RESUMEN

Surface plasmon resonance (SPR) is an interfacial phenomenon, and the plasmonic sensors are based on the optical excitation of the collective oscillations of free electrons at a metal-dielectric interface. Here, we present the new development of an incoherent broadband (IBB)-SPR probe combining the wavelength interrogation technique with polarization-multiplexing (PM). The performance characteristics of the so-called PMIBB-SPR strategy was validated for the detection of nonenzymatic aqueous urea samples as a representative example for plasmonic sensing with an excellent wavelength and phase sensitivities of 0.1363 nm/mM and 10.34597 mM/deg, respectively. We further explored the missing link between plasmonic polariton resonance (PPR) and polarization modulation via the measurements of the Stokes parameters of the reflected light. This deepens our understanding of the fundamentals of polarization-multiplexed SPR phenomenon at the interface. This study thus paves the way to develop a new-generation analytical technique with the aim of tracking various real-time chemical and biological molecular interactions occurring at the interfaces.


Asunto(s)
Técnicas Biosensibles , Resonancia por Plasmón de Superficie , Técnicas Biosensibles/métodos , Resonancia por Plasmón de Superficie/métodos , Urea
4.
Analyst ; 147(6): 1024-1054, 2022 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-35188498

RESUMEN

Selectivity is one of the most crucial figures of merit in trace gas sensing, and thus a comprehensive assessment is necessary to have a clear picture of sensitivity, selectivity, and their interrelations in terms of quantitative and qualitative views. Recent reviews on gas sensors/techniques are limited to specific sensors, sensors with unconventional materials, various technological exploitation, or specific applications. However, the selectivity is either unexplored in most cases or explained concerning the materials/techniques involved in a demonstration. Therefore, there is a pressing need to identify the possible ways to improve the selectivity of a gas sensor/technique with low or zero cross-sensitivity to other compounds/gases present in the working environment. Analytical techniques involving spectroscopic and mass-spectrometry-based methods are excellent in selectivity but have limited applicability for field deployment compared to the miniatured solid state sensors. Solid state sensors are the mainly studied gas sensors due to their flexibility, portability, and cost-effectiveness, and being technologically favorable but suffer from low selectivity in harsh and humid environments. This review will evaluate the limitations and possible solutions to selectivity issues in a wide variety of gas sensors. Here, we have discussed the gas-sensor technologies and underlying sensing mechanisms in two main groups - spectroscopic and non-spectroscopic. Recent state-of-the-art techniques and fundamental challenges are discussed to improve the selectivity and other gas sensor indicators and future perspectives.


Asunto(s)
Gases
5.
Biometals ; 35(3): 499-517, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35355153

RESUMEN

A family of dioxidovanadium(V) complexes (1-4) of the type [Na(H2O)x]+[VVO2(HL1-4)]- (x = 4, 4.5 and 7) where HL2- represents the dianionic form of 2-hydroxybenzoylhydrazone of 2-hydroxyacetophenone (H2L1, complex 1), 2-hydroxy-5-methylacetophenone (H2L2, complex 2), 2-hydroxy-5-methoxyacetophenone (H2L3, complex 3) and 2-hydroxy-5-chloroacetophenone (H2L4, complex 4), have been synthesized and characterized by analytical and spectral methods. These complexes exhibited the potential abilities to suppress the erythrocytes carbonic anhydrase enzymatic activity in type 1 and type 2 diabetic patients (in vitro), promising antidiabetic activity against T2 diabetic mice (in vivo). They also exhibited significant cytotoxic activity against cervical cancer (SiHa) cells (in vitro) as the IC50 value of complexes 1, 2 and 4 is substantially lower than the value found for cisplatin while that of 3 is comparable and follow the order: 4 < 1 < 2 < 3 and can kill the cells by apoptosis via the generation of reactive oxygen species (ROS). The complexes are soluble both in water and octanol media and also non-toxic at working concentrations. The antidiabetic activity of these four complexes follows the order: 4 > 2 > 1 > 3 while both the carbonic anhydrase and cytotoxic activity follow the order: 4 > 1 > 2 > 3 suggesting that complex 4, containing electron withdrawing Cl atom is the most reactive while 3 with electron donating OCH3 group is the least reactive species. The molecular docking study on hCA-I and hCA-II demonstrates that complexes interact via hydrogen bonding as well as different types of π-stacking.


Asunto(s)
Antineoplásicos , Anhidrasas Carbónicas , Diabetes Mellitus Experimental , Animales , Antineoplásicos/química , Antineoplásicos/farmacología , Inhibidores de Anhidrasa Carbónica/química , Inhibidores de Anhidrasa Carbónica/farmacología , Anhidrasas Carbónicas/metabolismo , Diabetes Mellitus Experimental/tratamiento farmacológico , Humanos , Hidrazonas/química , Hidrazonas/farmacología , Hipoglucemiantes/farmacología , Ratones , Simulación del Acoplamiento Molecular , Relación Estructura-Actividad
6.
Opt Lett ; 46(23): 5826-5829, 2021 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-34851900

RESUMEN

We report the experimental evidence of the Imbert-Fedorov (IF) shift in monolayer MoS2 for a fundamental Gaussian beam. Using Jones vector formalism, we have shown a novel, to the best of our knowledge, pathway to apply the quantum weak measurement technique for easy and accurate determination of the IF shift. We have revealed the dependence of IF shift over a large range of angles of incidence along with the mode of polarization of the incident light. Our experimental findings via the weak value amplification scheme are in good agreement with the theoretical analysis. The present method is a general one and can also be implemented for other materials to observe such tiny transverse shifts.

7.
Anal Chem ; 92(5): 3998-4005, 2020 03 03.
Artículo en Inglés | MEDLINE | ID: mdl-32008320

RESUMEN

We report on the development of a simple, linear optical cavity-based system combining evanescent wave (EW) with high-sensitive cavity ring-down spectroscopy (CRDS) technique using a diode laser at 644 nm and a right-angled prism for evanescent field generation on prism surface. We characterized the setup in detail and achieved an optimum ring-down time of 159.4 ns and a minimum absorption coefficient of αmin = 1.67 × 10-6 cm-1. We utilized this setup to investigate the salt-induced aggregation kinetics of gold (Au) and silver (Ag) nanoparticles (NPs) at the prism interface with high-sensitivity. We evaluated the extinction rates on the surface due to Au and Ag NPs aggregation and examined the variations due to their respective concentrations. To demonstrate the applicability of the developed EW-CRDS prototype setup to different molecular systems, we investigated the urease-bound aggregation kinetics of the Au and Ag NPs which has not been explored earlier by this linear cavity geometry. We finally illustrated the aggregation dynamics through surface imaging, thus demonstrating an alternative analytical approach to monitor interfacial phenomena using EW-CRDS technique.

8.
Anal Chem ; 92(8): 5717-5723, 2020 04 21.
Artículo en Inglés | MEDLINE | ID: mdl-32202406

RESUMEN

Water, the major body fluid in humans, has four main naturally occurring isotopologues, H216O, H217O, H218O, and H2H16O (i.e., HD16O) with different masses. The underlying mechanisms of the isotope-specific water-metabolism in the human gastrointestinal (GI) tract and respiratory system are largely unknown and remained illusive for several decades. Here, a new strategy has been demonstrated that provides direct quantitative experimental evidence of triple-isotopic signatures of water-metabolism in the human body in response to the individual's water intake habit. The distribution of water isotopes has been monitored in drinking water (DW; δD = -36.59 ± 10.64‰ (SD), δ18O = -5.41 ± 1.47‰ (SD), and δ17O = -2.92 ± 0.79‰ (SD)), GI fluid (GF; δD = -35.91 ± 7.30‰ (SD), δ18O = -3.98 ± 1.29‰ (SD), and δ17O = -2.37 ± 0.57‰ (SD)), and human exhaled breath (EB; δD = -119.63 ± 7.27‰ (SD), δ18O = -13.69 ± 1.23‰ (SD), and δ17O = -8.77 ± 0.98‰ (SD)) using a laser-based off-axis integrated cavity output spectroscopy (OA-ICOS) technique. This study explored a new analytical method to disentangle the competing effects of isotopic fractionations of water during respiration in humans. In addition, our findings revealed that deuterium-enriched exhaled semiheavy water, i.e., HD16O is a new marker of the noninvasive assessment of the ulcer-causing H. pylori gastric pathogen. We also clearly showed that the water-metabolism-derived triple-isotopic compositions due to impaired water absorption in the GI tract can be used as unique tracers to track the onset of various GI dysfunctions. These findings are thus bringing a new analytical methodology to better understand the isotope-selective water-metabolism that will have enormous applications for clinical testing purposes.


Asunto(s)
Líquidos Corporales/química , Agua Potable/análisis , Sistema Respiratorio/química , Agua/análisis , Adolescente , Adulto , Anciano , Deuterio , Femenino , Humanos , Masculino , Persona de Mediana Edad , Isótopos de Oxígeno , Análisis Espectral , Adulto Joven
9.
J Phys Chem A ; 124(6): 1104-1111, 2020 Feb 13.
Artículo en Inglés | MEDLINE | ID: mdl-31961682

RESUMEN

The underlying mechanisms of the triple-oxygen (16O, 17O, and 18O) isotopic content of deuterated (D) isotopologues of water in H-D exchange reactions in the gas phase remain elusive. Herein, we have demonstrated a high-resolution gas-phase spectral analysis of doubly (D2O) and singly (HDO) deuterated isotopologues of water in the region around 7.8 µm using quantum cascade laser-based cavity ring-down spectroscopy. Isotopic fractionations among doubly and singly deuterated species of water, D216O, HD16O, HD17O, and HD18O, in the gas phase were carried out by probing the fundamental and hot band transitions in the ν2 (bending) mode of D2O and the fundamental ν2 transitions for the other water isotopes. We subsequently investigated the fractionations of different D-enriched water isotopologues for the H-D exchange reaction using various mixtures of D2O in H2O. We explored the potential role of triple-oxygen isotopic contents through enrichments and depletions of HD16O, HD17O, and HD18O, involved in the H-D reaction. Our first clear, direct, and quantitative experimental evidence reveals a new picture of gas-phase isotopic fractionation chemistry in a mixture of light and heavy water (H2O-D2O).

10.
Anal Chem ; 90(2): 1384-1387, 2018 01 16.
Artículo en Inglés | MEDLINE | ID: mdl-29244947

RESUMEN

The oxygen-18 isotopic (18O) composition in CO2 provides an important insight into the variation of rate in isotopic fractionation reaction regulated by carbonic anydrase (CA) metalloenzyme. This work aims to employ an 18O-isotope ratio-based analytical method for quantitative estimation of CA activity in erythrocytes for clinical testing purposes. Here, a new method has been developed that contains the measurements of 18O/16O isotope ratios during oxygen-18 isotopic exchange between 12C16O16O and H218O of an in vitro biochemical reaction controlled by erythrocytes CA and estimation of enzymatic activity of CA from the isotopic composition of CO2. We studied the enrichments of 18O-isotope of CO2 with increments of CA activities during isotopic fractionation reaction. To check the influence of subject-specific body temperature, pH, H218O, and cellular produced CO2 on this reaction, we performed the in vitro experiments in closed containers with variations of those parameters. Finally, we mimicked the exchange reaction at 5% [CO2], 5‰ [H218O], pH of 7.4, and temperature of 37 °C to create the physiological environment equivalent to that of the human body and monitored the exchange kinetics with variations of CA activities, and subsequently, we derived the quantitative relation between the 18O-isotope of CO2 and CA activity in erythrocytes. This assay may be applicable for rapid and simple quantification of carbonic anhydrase activity which is very important to prevent the carbonic-anhydrase-associated disorders in human.


Asunto(s)
Dióxido de Carbono/metabolismo , Anhidrasas Carbónicas/metabolismo , Pruebas de Enzimas/métodos , Eritrocitos/enzimología , Isótopos de Oxígeno/análisis , Dióxido de Carbono/química , Pruebas de Enzimas/instrumentación , Diseño de Equipo , Humanos , Isótopos de Oxígeno/metabolismo
11.
Analyst ; 143(9): 2109-2114, 2018 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-29645022

RESUMEN

We report on the development of a mid-infrared cavity ring-down spectrometer (CRDS) coupled with a continuous wave (cw) external cavity quantum cascade laser (EC-QCL), operating between 6.0 µm and 6.3 µm, for high-resolution spectroscopic studies of ammonia (NH3) which served as a bench-mark molecule in this spectral region. We characterized the EC-QCL based CRDS system in detail and achieved a noise-equivalent absorption (NEA) coefficient of 2.11 × 10-9 cm-1 Hz-1/2 for a 100 Hz data acquisition rate. We thereafter exploited the system for high-resolution spectroscopic analysis of interference-free 10 transition lines of the ν4 fundamental vibrational band of NH3 centred at ∼6.2 µm. We probed the strongest interference-free absorption line RQ(4,3) of ν4, centred at 1613.370 cm-1 for highly-sensitive trace detection of NH3 and subsequently achieved a minimum detection sensitivity (1σ) of 2.78 × 109 molecules per cm3 which translated into the detection limit of 740 parts-per-trillion by volume (pptv/10-12) at a pressure of 115 Torr for an integration time of ∼167 seconds. To demonstrate the efficacy of the present system in real-life applications, we finally measured the mixing ratios of NH3 present in ambient air and human exhaled breath with high sensitivity and molecular specificity.

12.
Anal Bioanal Chem ; 409(1): 193-200, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27747374

RESUMEN

The 13C-urea breath test (13C-UBT), developed a few decades ago, is widely used as a non-invasive diagnostic method to detect only the presence of the gastric pathogen Helicobacter pylori infection; however, the actual disease state, i.e. whether the person harbouring H. pylori has peptic ulcer disease (PUD) or non-ulcerous dyspepsia (NUD), is still poorly understood. Nevertheless, the present 13C-UBT has numerous limitations, drawbacks and pitfalls owing to the ingestion of 13C-labelled external urea. Here, we show that H. pylori is able to utilize the natural 13C and 18O-urea inherently present in the gastric juice in humans for its urease activity which has never been explored before. In vitro measurements of isotopic fractionations of gastric juice urea provide new insights into the actual state of the infection of PUD or NUD. We also provide evidence of the unusual 13C and 18O-isotopic fractionations of breath CO2 that are distinctively altered in individuals with PUD encompassing both gastric and duodenal ulcers as well as with NUD by the enzymatic activity of H. pylori in the gastric niche without oral administration of any 13C-enriched external urea. This deepens our understanding of the UBT exploiting the natural 13C and 18O-gastric juice urea in the pathogenesis of H. pylori infection, reveals the actual disease state of PUD or NUD and thus offers novel opportunities for a simple, robust, cost-effective and non-toxic global strategy devoid of any 13C-enriched urea for treating these common diseases by a single breath test. Graphical Abstract Urea breath test without any external urea.


Asunto(s)
Dispepsia/diagnóstico , Jugo Gástrico/química , Infecciones por Helicobacter/diagnóstico , Helicobacter pylori/aislamiento & purificación , Úlcera Péptica/diagnóstico , Urea/análisis , Adolescente , Adulto , Anciano , Pruebas Respiratorias , Isótopos de Carbono/análisis , Femenino , Humanos , Masculino , Persona de Mediana Edad , Isótopos de Oxígeno/análisis , Adulto Joven
14.
Anal Chem ; 88(4): 2205-11, 2016 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-26790755

RESUMEN

A residual gas analyzer (RGA) coupled with a high-vacuum chamber has been explored to measure atmospheric CO2 entrapped in aminosilane-modified clay nanotubes. Ambient CO2 uptake efficacy together with stability of these novel adsorbents composed of both primary and/or secondary amine sites has been demonstrated at standard ambient temperature and pressure. The unprecedented sensitivity and accuracy of the RGA-based mass spectrometry technique toward atmospheric CO2 measurement has been substantiated with a laser-based optical cavity-enhanced integrated cavity output spectroscopy. The adsorption kinetics of atmospheric CO2 on amine-functionalized clay nanotubes followed the fractional-order kinetic model compared to that of the pseudo-first-order or pseudo-second-order rate equations. The efficiency along with stability of these novel adsorbents has also been demonstrated by their repetitive use for CO2 capture in the oxidative environment. Our findings thus point to a fundamental study on the atmospheric CO2 adsorption by amine-loaded adsorbents using an easy handling and low-cost benchtop RGA-based mass spectrometer, opening a new strategy for CO2 capture and sequestering study.

15.
Opt Lett ; 41(9): 1949-52, 2016 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-27128046

RESUMEN

A high-resolution cavity ring-down spectroscopic (CRDS) system based on a continuous wave (cw) mode-hop-free (MHF) external-cavity quantum cascade laser (EC-QCL) operating at λ∼5.2 µm has been developed for ultrasensitive detection of nitric oxide (NO). We report the performance of the high-resolution EC-QCL based cw-CRDS instrument by measuring the rotationally resolved Λ-doublet e and f components of the P(7.5) line in the fundamental band of NO at 1850.169 cm-1 and 1850.179 cm-1. A noise-equivalent absorption coefficient of 1.01×10-9 cm-1 Hz-1/2 was achieved based on an empty cavity ring-down time of τ0=5.6 µs and standard deviation of 0.11% with averaging of six ring-down time determinations. The CRDS sensor demonstrates the advantages of measuring parts per billion NO concentrations in N2, as well as in human breath samples with ultrahigh sensitivity and specificity. The CRDS system could also be generalized to measure simultaneously many other trace molecular species within the broad tuning range of cw EC-QCL, as well as for studying the rotationally resolved hyperfine structures.

16.
Anal Bioanal Chem ; 406(22): 5405-12, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24939135

RESUMEN

We report for the first time the excretion kinetics of the percentage dose of (13)C recovered/h ((13)C-PDR %/h) and cumulative PDR, i.e. c-PDR (%) to accomplish the highest diagnostic accuracy of the (13)C-urea breath test ((13)C-UBT) for the detection of Helicobacter pylori infection without any risk of diagnostic errors using an optical cavity-enhanced integrated cavity output spectroscopy (ICOS) method. An optimal diagnostic cut-off point for the presence of H. pylori infection was determined to be c-PDR (%) = 1.47 % at 60 min, using the receiver operating characteristic curve (ROC) analysis to overcome the "grey zone" containing false-positive and false-negative results of the (13)C-UBT. The present (13)C-UBT exhibited 100 % diagnostic sensitivity (true-positive rate) and 100 % specificity (true-negative rate) with an accuracy of 100 % compared with invasive endoscopy and biopsy tests. Our c-PDR (%) methodology also manifested both diagnostic positive and negative predictive values of 100 %, demonstrating excellent diagnostic accuracy. We also observed that the effect of endogenous CO2 production related to basal metabolic rates in individuals was statistically insignificant (p = 0.78) on the diagnostic accuracy. However, the presence of H. pylori infection was indicated by the profound effect of urea hydrolysis rate (UHR). Our findings suggest that the current c-PDR (%) is a valid and sufficiently robust novel approach for an accurate, specific, fast and noninvasive diagnosis of H. pylori infection, which could routinely be used for large-scale screening purposes and diagnostic assessment, i.e. for early detection and follow-up of patients.


Asunto(s)
Pruebas Respiratorias , Dióxido de Carbono/química , Isótopos de Carbono/química , Infecciones por Helicobacter/diagnóstico , Adulto , Anciano , Calibración , Reacciones Falso Positivas , Femenino , Helicobacter pylori , Humanos , Hidrólisis , Cinética , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Curva ROC , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Espectrofotometría , Urea/química , Adulto Joven
17.
J Phys Chem Lett ; 15(16): 4430-4436, 2024 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-38626390

RESUMEN

Elucidating isotope exchange between atmospheric trace molecular species is important for environment monitoring, climate control studies, and a fundamental understanding of atmospheric chemistry. Here, we provide direct experimental evidence of oxygen-isotopic exchange between carbon dioxide (CO2) and nitrogen dioxide (NO2), which are simultaneously emitted into the atmosphere from common sources. A combined near-infrared and UV-vis optical cavity-enhanced experimental investigation along with quantum-chemical calculations followed by a reaction modeling study revealed that CO2 and NO2 can communicate isotopically by near-ultraviolet-driven NO2 photolysis. Our results found evidence for a near-barrierless (1.67 kcal/mol) nitrate-containing complex having a very short lifetime (∼13 ns) which facilitates the transfer of 18O-isotopes from 18O12C16O to N16O16O, leading to isotopic depletion of 18O in 18O12C16O, thus opening a new gas-phase isotope-selective chemical transformation mechanism in the lower atmosphere. This isotope exchange study may serve as a new window into the fundamental understanding of isotopic photochemistry, oxygen isotopic fractionations, and climate modeling.

18.
Eur J Mass Spectrom (Chichester) ; 29(3): 192-199, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37192662

RESUMEN

Conventional endoscopic biopsy tests are not suitable for early detection of the acute onset and progression of peptic ulcer as well as various gastric complications. This also limits its suitability for widespread population-based screening and consequently, many people with complex gastric phenotypes remain undiagnosed. Here, we demonstrate a new non-invasive methodology for accurate diagnosis and classification of various gastric disorders exploiting a pattern-recognition-based cluster analysis of a breathomics dataset generated from a simple residual gas analyzer-mass spectrometry. The clustering approach recognizes unique breathograms and "breathprints" signatures that clearly reflect the specific gastric condition of an individual person. The method can selectively distinguish the breath of peptic ulcer and other gastric dysfunctions like dyspepsia, gastritis, and gastroesophageal reflux disease patients from the exhaled breath of healthy individuals with high diagnostic sensitivity and specificity. Moreover, the clustering method exhibited a reasonable power to selectively classify the early-stage and high-risk gastric conditions with/without ulceration, thus opening a new non-invasive analytical avenue for early detection, follow-up, and fast population-based robust screening strategy of gastric complications in the real-world clinical domain.


Asunto(s)
Dispepsia , Gastritis , Úlcera Péptica , Humanos , Pruebas Respiratorias/métodos , Úlcera Péptica/complicaciones , Úlcera Péptica/diagnóstico , Dispepsia/complicaciones , Dispepsia/diagnóstico , Gastritis/diagnóstico , Gastritis/complicaciones , Sensibilidad y Especificidad
19.
Isotopes Environ Health Stud ; 57(4): 368-385, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34080500

RESUMEN

Water vapor, the most important greenhouse gas in the atmosphere, has four natural stable isotopologues (H216O, H217O, H218O and HD16O), and their isotopic compositions can be used as hydrological tracers. But the underlying processes and pattern-dynamics of the isotopic compositions of atmospheric water vapor and precipitation in response to various meteorological conditions during monsoon season in a tropical hot and humid region is poorly understood. Here, we present results of H and triple-O-isotopes of water in precipitation and atmospheric water vapor during monsoon season exploiting high-resolution integrated cavity output spectroscopy technique. We observed a distinct temporal variation of the isotopic compositions of water at different phases of the monsoon. The diurnal patterns of the isotopic variations were influenced by the local meteorological factors such as temperature, relative humidity and amount of precipitation. We also investigated the monsoonal dynamics of the second-order isotopic parameters, so-called d-excess and 17O-excess along with the influence of local meteorological factors on isotopic variations to improve our understanding of the underlying isotopic fractionation processes. Consequently, our results provide a unique isotopic-fingerprint dataset of rainwater and atmospheric water vapor for a tropical region and thus shed a new light on hydrological and meteorological processes in the atmosphere.


Asunto(s)
Deuterio/análisis , Isótopos de Oxígeno/análisis , Lluvia/química , Vapor/análisis , Atmósfera , Tormentas Ciclónicas , India , Estaciones del Año , Análisis Espectral , Temperatura
20.
Spectrochim Acta A Mol Biomol Spectrosc ; 263: 120193, 2021 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-34314969

RESUMEN

We report a robust technique to fabricate a cost-efficient Raman substrate which is composed of polyvinylpyrrolidone (PVP) coated gold nanoparticles layer on commercial aluminum foil. The layer of metal nanoparticles on the aluminum foil, i.e., the nanoparticle-on-mirror (NPoM) structure was fabricated by spraying nanoparticle colloidal solution directly on the foil. The detection limit (LOD) of NPoM substrate is investigated by performing the SERS for Rhodamine 6G (R6G) with the concentration ranging from mM to nM without any post treatment of the substrate. The findings show that the LOD of 1 nM and maximum intensity enhancement factor of ~ 24 is accomplished. Field enhancement owing to reflection from the metallic mirror is the reason behind the signal enhancement and it would be beneficial for routine clinical applications, trace chemical detection, and disease diagnostics.


Asunto(s)
Nanopartículas del Metal , Espectrometría Raman , Análisis Costo-Beneficio , Oro , Povidona
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA