1.
Skeletal Radiol ; 50(5): 955-965, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33037447

RESUMEN

OBJECTIVE: To determine whether a simulated low-dose metal artifact reduction (MAR) CT technique is comparable with a clinical dose MAR technique for shoulder arthroplasty evaluation. MATERIALS AND METHODS: Two shoulder arthroplasties in cadavers and 25 shoulder arthroplasties in patients were scanned using a clinical dose (140 kVp, 300 qrmAs); cadavers were also scanned at half dose (140 kVp, 150 qrmAs). Images were reconstructed using a MAR CT algorithm at full dose and a noise-insertion algorithm simulating 50% dose reduction. For the actual and simulated half-dose cadaver scans, differences in SD for regions of interest were assessed, and streak artifact near the arthroplasty was graded by 3 blinded readers. Simulated half-dose scans were compared with full-dose scans in patients by measuring differences in implant position and by comparing readers' grades of periprosthetic osteolysis and muscle atrophy. RESULTS: The mean difference in SD between actual and simulated half-dose methods was 2.42 HU (95% CI [1.4, 3.4]). No differences in streak artifact grades were seen in 13/18 (72.2%) comparisons in cadavers. In patients, differences in implant position measurements were within 1° or 1 mm in 149/150 (99.3%) measurements. The inter-reader agreement rates were nearly identical when readers were using full-dose (77.3% [232/300] for osteolysis and 76.9% [173/225] for muscle atrophy) and simulated half-dose (76.7% [920/1200] for osteolysis and 74.0% [666/900] for muscle atrophy) scans. CONCLUSION: A simulated half-dose MAR CT technique is comparable both quantitatively and qualitatively with a standard-dose technique for shoulder arthroplasty evaluation, demonstrating that this technique could be used to reduce dose in arthroplasty imaging.


Asunto(s)
Artefactos , Tomografía Computarizada por Rayos X , Algoritmos , Artroplastia , Cadáver , Humanos , Metales , Fantasmas de Imagen
2.
AJR Am J Roentgenol ; 215(2): 425-432, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32374668

RESUMEN

OBJECTIVE. The purpose of this study was to compare a combined dual-energy CT (DECT) and single-energy CT (SECT) metal artifact reduction technique with a SECT metal artifact reduction technique for detecting lesions near an arthroplasty in a phantom model. MATERIALS AND METHODS. Two CT phantoms with a cobalt chromium sphere attached to a titanium rod, simulating an arthroplasty, within a background of soft-tissue attenuation containing spherical lesions (range, 10-20 mm) around the head and stem of different attenuations from the background (range of attenuation, 10-70 HU) were scanned with a single CT scanner individually (unilateral) and together (bilateral) with the following three dose-equivalent techniques: the currently used clinical protocol (140 kVp, 300 Reference mAs); 100 kVp; and DECT (100 kVp and 150 kVp with a tin filter). Three radiologists reviewed the datasets to identify lesions. Nonparametric AUC was estimated for each reader with each technique. Multireader ANOVA was performed to compare AUCs. Multiple-variable logistic regression analysis was used to identify factors affecting sensitivity and specificity. RESULTS. Accuracy was lower (p < 0.001) for the DECT 130-keV technique than for the 100-, 70-, and 140-kVp techniques. Sensitivity was higher with unilateral arthroplasties (p = 0.037), with greater contrast differences from background (p < 0.001), and with the SECT 100-kVp technique versus other techniques (p < 0.001). The difference in specificities of modalities was not statistically significant (p = 0.148). CONCLUSION. Combining DECT and SECT techniques does not provide additional benefits for lesion detection as opposed to using SECT alone.


Asunto(s)
Artefactos , Aleaciones de Cromo , Prótesis Articulares , Titanio , Tomografía Computarizada por Rayos X/métodos , Artroplastia , Fantasmas de Imagen , Imagen Radiográfica por Emisión de Doble Fotón
3.
AJR Am J Roentgenol ; 210(3): 593-600, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-29231758

RESUMEN

OBJECTIVE: The objective of this study was to compare reader accuracy detecting lesions near hardware in a CT phantom model at different radiation exposures using an advanced metal artifact reduction (MAR) algorithm and standard filtered back projection (FBP) techniques and to determine if radiation exposure could be decreased using MAR without compromising lesion detectability. MATERIALS AND METHODS: A CT phantom manufactured with spherical lesions of various sizes (10-20 mm) and attenuations (20-50 HU) embedded around cobalt-chromium spheres attached to titanium rods, simulating an arthroplasty, was scanned on a single CT scanner (FLASH, Siemens Healthcare) at 140 kVp and 0.6-mm collimation using clinical-dose (300 Quality Reference mAs [Siemens Healthcare]), low-dose (150 Quality Reference mAs), and high-dose (600 Quality Reference mAs) protocols. Images reconstructed with iterative MAR, advanced modeled iterative reconstruction (ADMIRE), and FBP with identical parameters were anonymized and independently reviewed by three radiologists. Accuracies for detecting lesions, measured as AUC, sensitivity, and specificity, were compared. RESULTS: Accuracy using MAR was significantly higher than that using FBP at all exposures (p values ranged from < 0.001 to 0.021). Sensitivity was also higher for MAR than for FBP at all exposures. Specificity was very high for both reconstruction techniques at all exposures with no significant differences. Accuracy of low-dose MAR was higher than and not inferior to standard-dose and high-dose FBP. MAR was significantly more sensitive than FBP in detecting smaller lesions (p = 0.021) and lesions near high streak artifact (p < 0.001). CONCLUSION: MAR improves reader accuracy to detect lesions near hardware and allows significant reductions in radiation exposure without compromising accuracy compared with FBP in a CT phantom model.


Asunto(s)
Artefactos , Metales , Prótesis e Implantes , Dosis de Radiación , Protección Radiológica/métodos , Tomografía Computarizada por Rayos X/métodos , Algoritmos , Humanos , Variaciones Dependientes del Observador , Fantasmas de Imagen
4.
J Comput Assist Tomogr ; 42(4): 623-629, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29613990

RESUMEN

PURPOSE: The purpose of this study was to compare quantitative and qualitative measures of aortic, cardiac, and respiratory motion artifact between high-pitch dual-source (DS) and single-source (SS) computed tomography pulmonary angiography (CTPA) protocols. METHODS: This institutional review board-approved, Health Insurance Portability and Accountability Act-compliant study retrospectively reviewed 80 non-electrocardiogram-gated CTPA examinations acquired with a second-generation DS system at 100 kVp following 50 mL iodinated contrast injection - 40 consecutive SS and 40 consecutive DS studies. Quantitative measures of aortic, left ventricular, and diaphragmatic motion were recorded as the maximal excursion of a structure's "double image," and 3 independent readers performed qualitative motion assessments. Pulmonary arterial contrast enhancement, image noise, and radiation dose metrics were recorded. Statistical analyses were performed with 1-way analysis of variance and Fisher exact test. RESULTS: Dual source outperformed SS technique in both quantitative and qualitative measures of motion. Mean distances between motion-artifact double images were reduced with DS protocol at each location (all P ≤ 0.004), and DS examinations were more likely to receive an assessment of no motion in all locations (all P < 0.0001). The DS protocol demonstrated increases in contrast enhancement, although increased image noise resulted in lower enhancement to noise ratio. Mean radiation dose was 60% lower using the DS protocol. CONCLUSION: High-pitch DS CTPA significantly reduces artifacts resulting from ascending aortic, cardiac, and diaphragmatic motion.


Asunto(s)
Artefactos , Angiografía por Tomografía Computarizada/métodos , Arteria Pulmonar/diagnóstico por imagen , Embolia Pulmonar/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Movimiento (Física) , Estudios Retrospectivos , Relación Señal-Ruido , Adulto Joven
5.
Radiology ; 280(2): 475-82, 2016 08.
Artículo en Inglés | MEDLINE | ID: mdl-26937709

RESUMEN

Purpose To assess image noise, contrast-to-noise ratio (CNR) and detectability of low-contrast, low-attenuation liver lesions in a semianthropomorphic phantom by using either a discrete circuit (DC) detector and filtered back projection (FBP) or an integrated circuit (IC) detector and iterative reconstruction (IR) with changes in radiation exposure and phantom size. Materials and Methods An anthropomorphic phantom without or with a 5-cm-thick fat-mimicking ring (widths, 30 and 40 cm) containing liver inserts with four spherical lesions was scanned with five exposure settings on each of two computed tomography scanners, one equipped with a DC detector and the other with an IC detector. Images from the DC and IC detector scanners were reconstructed with FBP and IR, respectively. Image noise and lesion CNR were measured. Four radiologists evaluated lesion presence on a five-point diagnostic confidence scale. Data analyses included receiver operating characteristic (ROC) curve analysis and noninferiority analysis. Results The combination of IC and IR significantly reduced image noise (P < .001) (with the greatest reduction in the 40-cm phantom and at lower exposures) and improved lesion CNR (P < .001). There was no significant difference in area under the ROC curve between detector-reconstruction combinations at fixed exposure for either phantom. Reader accuracy with IC-IR was noninferior at 50% (100 mAs [effective]) and 25% (300 mAs [effective]) exposure reduction for the 30- and 40-cm phantoms, respectively (adjusted P < .001 and .04 respectively). IC-IR improved readers' confidence in the presence of a lesion (P = .029) independent of phantom size or exposure level. Conclusion IC-IR improved objective image quality and lesion detection confidence but did not result in superior diagnostic accuracy when compared with DC-FBP. Moderate exposure reductions maintained comparable diagnostic accuracy for both detector-reconstruction combinations. Lesion detection in the 40-cm phantom was inferior at smaller exposure reduction than in the 30-cm phantom. (©) RSNA, 2016 Online supplemental material is available for this article.


Asunto(s)
Artefactos , Hígado/diagnóstico por imagen , Tomografía Computarizada Multidetector/métodos , Fantasmas de Imagen , Exposición a la Radiación/estadística & datos numéricos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Humanos , Tomografía Computarizada Multidetector/estadística & datos numéricos , Dosis de Radiación , Relación Señal-Ruido
6.
Radiology ; 280(2): 436-45, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27077382

RESUMEN

Purpose To compare the diagnostic accuracy and image quality of computed tomographic (CT) enterographic images obtained at half dose and reconstructed with filtered back projection (FBP) and sinogram-affirmed iterative reconstruction (SAFIRE) with those of full-dose CT enterographic images reconstructed with FBP for active inflammatory terminal or neoterminal ileal Crohn disease. Materials and Methods This retrospective study was compliant with HIPAA and approved by the institutional review board. The requirement to obtain informed consent was waived. Ninety subjects (45 with active terminal ileal Crohn disease and 45 without Crohn disease) underwent CT enterography with a dual-source CT unit. The reference standard for confirmation of active Crohn disease was active terminal ileal Crohn disease based on ileocolonoscopy or established Crohn disease and imaging features of active terminal ileal Crohn disease. Data from both tubes were reconstructed with FBP (100% exposure); data from the primary tube (50% exposure) were reconstructed with FBP and SAFIRE strengths 3 and 4, yielding four datasets per CT enterographic examination. The mean volume CT dose index (CTDIvol) and size-specific dose estimate (SSDE) at full dose were 13.1 mGy (median, 7.36 mGy) and 15.9 mGy (median, 13.06 mGy), respectively, and those at half dose were 6.55 mGy (median, 3.68 mGy) and 7.95 mGy (median, 6.5 mGy). Images were subjectively evaluated by eight radiologists for quality and diagnostic confidence for Crohn disease. Areas under the receiver operating characteristic curves (AUCs) were estimated, and the multireader, multicase analysis of variance method was used to compare reconstruction methods on the basis of a noninferiority margin of 0.05. Results The mean AUCs with half-dose scans (FBP, 0.908; SAFIRE 3, 0.935; SAFIRE 4, 0.924) were noninferior to the mean AUC with full-dose FBP scans (0.908; P < .003). The proportion of images with inferior quality was significantly higher with all half-dose reconstructions than with full-dose FBP (mean proportion: 0.117 for half-dose FBP, 0.054 for half-dose SAFIRE 3, 0.054 for half-dose SAFIRE 4, and 0.017 for full-dose FBP; P < .001). Conclusion The diagnostic accuracy of half-dose CT enterography with FBP and SAFIRE is statistically noninferior to that of full-dose CT enterography for active inflammatory terminal ileal Crohn disease, despite an inferior subjective image quality. (©) RSNA, 2016 Online supplemental material is available for this article.


Asunto(s)
Enfermedad de Crohn/diagnóstico por imagen , Ileítis/diagnóstico por imagen , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Enfermedad de Crohn/complicaciones , Femenino , Tracto Gastrointestinal/diagnóstico por imagen , Humanos , Ileítis/complicaciones , Íleon/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados
7.
AJR Am J Roentgenol ; 207(2): 378-85, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27186794

RESUMEN

OBJECTIVE: The purpose of this study was to compare iterative metal artifact reduction (iMAR), a new single-energy metal artifact reduction technique, with filtered back projection (FBP) in terms of attenuation values, qualitative image quality, and streak artifacts near shoulder and hip arthroplasties and observer ability with these techniques to detect pathologic lesions near an arthroplasty in a phantom model. MATERIALS AND METHODS: Preoperative and postoperative CT scans of 40 shoulder and 21 hip arthroplasties were reviewed. All postoperative scans were obtained using the same technique (140 kVp, 300 quality reference mAs, 128 × 0.6 mm detector collimation) on one of three CT scanners and reconstructed with FBP and iMAR. The attenuation differences in bones and soft tissues between preoperative and postoperative scans at the same location were compared; image quality and streak artifact for both reconstructions were qualitatively graded by two blinded readers. Observer ability and confidence to detect lesions near an arthroplasty in a phantom model were graded. RESULTS: For both readers, iMAR had more accurate attenuation values (p < 0.001), qualitatively better image quality (p < 0.001), and less streak artifact (p < 0.001) in all locations near arthroplasties compared with FBP. Both readers detected more lesions (p ≤ 0.04) with higher confidence (p ≤ 0.01) with iMAR than with FBP in the phantom model. CONCLUSION: The iMAR technique provided more accurate attenuation values, better image quality, and less streak artifact near hip and shoulder arthroplasties than FBP; iMAR also increased observer ability and confidence to detect pathologic lesions near arthroplasties in a phantom model.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Artroplastía de Reemplazo de Hombro , Prótesis de Cadera , Prótesis de Hombro , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Artefactos , Femenino , Humanos , Masculino , Metales , Persona de Mediana Edad , Fantasmas de Imagen , Interpretación de Imagen Radiográfica Asistida por Computador , Estudios Retrospectivos
8.
AJR Am J Roentgenol ; 205(3): 592-8, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26295647

RESUMEN

OBJECTIVE: The purposes of this study were to determine the differences in estimated volumetric CT dose index (CTDIvol) obtained from the topogram before abdominal and pelvic MDCT in adult and pediatric patients using a scan type-based algorithm for selecting kilovoltage (CARE kV) and a fixed and a weight-based Quality Reference mAs for selecting tube (gmAs) current-exposure time product, in comparison with standard protocols, and to determine the bias and variability of estimated CTDIvol vis-à-vis actual CTDIvol using the standard protocols. MATERIALS AND METHODS: During a 14-month period, 312 adult and pediatric patients referred for abdominal and pelvic MDCT were included in the study. For all patients, the estimated CTDIvol based on the topogram was recorded: protocol A, CARE kV on and 210 gmAs; protocol B, CARE kV on and 1 gmAs times patient weight (in pounds); and protocol C (standard protocol), CARE kV off, 120 kVp, and 1 gmAs times patient weight (in pounds). For the pediatric patients, estimated CTDIvol for the standard protocol D was calculated with 120 kVp and 150 gmAs. All patients were scanned with the standard protocols, and the actual CTDIvol was recorded. Linear regression models compared the CTDIvol of the three protocols in adults and the fourth for children. The estimated and actual CTDIvol were compared using a t test. RESULTS: Protocol B yielded the lowest estimated CTDIvol (mean, 13.2 mGy for adults and 3.5 mGy for pediatric patients). The estimated CTDIvol overestimated the actual CTDIvol by, on average, 1.07 mGy for adults and 0.3 mGy for children. CONCLUSION: CARE kV appears to reduce estimated CTDIvol vis-à-vis standard protocols only when a weight-based gmAs is used. Prescan estimated CTDIvol calculations appear to generally overestimate actual CTDIvol.


Asunto(s)
Tomografía Computarizada Multidetector/instrumentación , Dosis de Radiación , Adolescente , Adulto , Algoritmos , Niño , Preescolar , Femenino , Humanos , Lactante , Masculino , Radiografía Abdominal
9.
Radiology ; 272(1): 154-63, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24620913

RESUMEN

PURPOSE: To measure the effect of reduced radiation exposure on low-contrast low-attenuation liver lesion detection in an anthropomorphic abdominal phantom by using filtered back projection (FBP) and sinogram-affirmed iterative reconstruction. MATERIALS AND METHODS: Eighteen radiologists blinded to phantom and study design interpreted randomized image data sets that contained 36 spherical simulated liver lesions of three sizes and three attenuation differences (5-mm diameter: 12, 18, and 24 HU less than the 90-HU background attenuation of the simulated liver insert; 10- and 15-mm diameter: 6, 12, and 18 HU less than the 90-HU background attenuation) scanned with four discrete exposure settings and reconstructed by using FBP and sinogram-affirmed iterative reconstruction. Response assessment included region-level lesion presence or absence on a five-point diagnostic confidence scale. Statistical evaluation included multireader multicase receiver operating characteristic curve analysis, with nonparametric methods and noninferiority analysis at a margin of -0.10. RESULTS: Pooled accuracy at 75% exposure for both FBP and sinogram-affirmed iterative reconstruction was noninferior to 100% exposure (P = .002 and P < .001, respectively). Subsequent exposure reductions resulted in a significant decrease in accuracy. When the smallest (5-mm-diameter) lesions were excluded from analysis, sinogram-affirmed iterative reconstruction was superior to FBP at 100% exposure (P = .011), and sinogram-affirmed iterative reconstruction at 25% and 50% exposure reduction was noninferior to FBP at 100% exposure (P ≤ .013). Reader confidence was greater with sinogram-affirmed iterative reconstruction than with FBP for 10- and 15-mm lesions (2.94 vs 2.76 and 3.62 vs 3.52, respectively). CONCLUSION: In this low-contrast low-attenuation liver lesion model, a 25% exposure reduction maintained noninferior diagnostic accuracy. However, detection was inferior with each subsequent exposure reduction, regardless of reconstruction method. Sinogram-affirmed iterative reconstruction and FBP performed equally well at modest exposure reduction (25%-50%). Readers had higher confidence levels with sinogram-affirmed iterative reconstruction for the 10- and 15-mm lesions.


Asunto(s)
Hepatopatías/diagnóstico por imagen , Fantasmas de Imagen , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador , Radiografía Abdominal/métodos , Tomografía Computarizada por Rayos X/métodos , Humanos , Programas Informáticos
10.
Skeletal Radiol ; 43(12): 1729-35, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25172218

RESUMEN

OBJECTIVE: Iterative metal artifact reduction (IMAR) is a sinogram inpainting technique that incorporates high-frequency data from standard weighted filtered back projection (WFBP) reconstructions to reduce metal artifact on computed tomography (CT). This study was designed to compare the image quality of IMAR and WFBP in total shoulder arthroplasties (TSA); determine the optimal amount of WFBP high-frequency data needed for IMAR; and compare image quality of the standard 3D technique with that of a faster 2D technique. MATERIALS AND METHODS: Eight patients with nine TSA underwent CT with standardized parameters: 140 kVp, 300 mAs, 0.6 mm collimation and slice thickness, and B30 kernel. WFBP, three 3D IMAR algorithms with different amounts of WFBP high-frequency data (IMARlo, lowest; IMARmod, moderate; IMARhi, highest), and one 2D IMAR algorithm were reconstructed. Differences in attenuation near hardware and away from hardware were measured and compared using repeated measures ANOVA. Five readers independently graded image quality; scores were compared using Friedman's test. RESULTS: Attenuation differences were smaller with all 3D IMAR techniques than with WFBP (p < 0.0063). With increasing high-frequency data, the attenuation difference increased slightly (differences not statistically significant). All readers ranked IMARmod and IMARhi more favorably than WFBP (p < 0.05), with IMARmod ranked highest for most structures. The attenuation difference was slightly higher with 2D than with 3D IMAR, with no significant reader preference for 3D over 2D. CONCLUSIONS: IMAR significantly decreases metal artifact compared to WFBP both objectively and subjectively in TSA. The incorporation of a moderate amount of WFBP high-frequency data and use of a 2D reconstruction technique optimize image quality and allow for relatively short reconstruction times.


Asunto(s)
Artefactos , Metales , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Articulación del Hombro/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Algoritmos , Análisis de Varianza , Artroplastia , Femenino , Humanos , Imagenología Tridimensional/métodos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
11.
Radiology ; 256(1): 184-90, 2010 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-20574095

RESUMEN

PURPOSE: To evaluate the detectability of urinary stones on virtual nonenhanced images generated at pyelographic-phase dual-energy computed tomography (CT). MATERIALS AND METHODS: This retrospective HIPAA-compliant study was institutional review board approved. All included patients had previously consented to the use of their medical records for research. Sixty-two patients (38 men, 24 women; age range, 35-91 years) had undergone CT urography, which consisted of nonenhanced and pyelographic-phase dual-energy CT performed by using a dual-source scanner. Commercial software was used to create virtual nonenhanced images by suppressing the iodine signal from the pyelographic-phase dual-energy CT scans. Two radiologists, in consensus, evaluated the virtual nonenhanced images for the presence of stones. Sensitivity for detecting stones was calculated on a per-stone basis. Sensitivity, specificity, and accuracy were also calculated on a per-renal unit (defined as the intrarenal collecting system and ureter of one kidney) basis. The true nonenhanced scan was considered the reference standard. A jackknife method was used because any patient may have multiple stones. RESULTS: Of 62 patients with 122 renal units, 21 patients with 25 renal units had a total of 43 stones (maximal transverse diameter range, 1-24 mm; median, 3 mm). The overall sensitivity for detecting stones was 63% (27 of 43 stones) per stone. Sensitivities were 29% (four of 14 stones) for 1-2-mm stones, 64% (nine of 14 stones) for 3-4-mm stones, 83% (five of six stones) for 5-6-mm stones, and 100% (nine of nine stones) for 7-mm or larger (7, 7, 7, 8, 8, 9, 11, 15, and 24 mm) stones. All three ureteral stones (3, 4, and 8 mm) were correctly identified. The sensitivity, specificity, and accuracy for detecting stones on a per-renal unit basis were 65% (17 of 26 renal units), 92% (88 of 96 renal units), and 86% (105 of 122 renal units), respectively. CONCLUSION: Virtual nonenhanced images generated at pyelographic-phase dual-energy CT enabled the detection of urinary stones with moderate accuracy. The detection of small (1-2-mm) stones was limited.


Asunto(s)
Tomografía Computarizada por Rayos X/métodos , Cálculos Urinarios/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Intervalos de Confianza , Medios de Contraste , Femenino , Humanos , Yohexol , Masculino , Persona de Mediana Edad , Interpretación de Imagen Radiográfica Asistida por Computador , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Estudios Retrospectivos , Sensibilidad y Especificidad , Programas Informáticos , Técnica de Sustracción , Urografía
12.
Med Phys ; 37(2): 897-906, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-20229899

RESUMEN

PURPOSE: To determine the constancy of z-axis spatial resolution, CT number, image noise, and the potential for image artifacts for nonconstant velocity spiral CT data reconstructed using a flexibly weighted 3D filtered backprojection (WFBP) reconstruction algorithm. METHODS: A WFBP reconstruction algorithm was used to reconstruct stationary (axial, pitch=0), constant velocity spiral (pitch = 0.35-1.5) and nonconstant velocity spiral CT data acquired using a 128 x 0.6 mm acquisition mode (38.4 mm total detector length, z-flying focal spot technique), and a gantry rotation time of 0.30 s. Nonconstant velocity scans used the system's periodic spiral mode, where the table moved in and out of the gantry in a cyclical manner. For all scan types, the volume CTDI was 10 mGy. Measurements of CT number, image noise, and the slice sensitivity profile were made for all scan types as a function of the nominal slice width, table velocity, and position within the scan field of view. A thorax phantom was scanned using all modes and reconstructed transverse and coronal plane images were compared. RESULTS: Negligible differences in slice thickness, CT number, noise, or artifacts were found between scan modes for data taken at two positions within the scan field of view. For nominal slices of 1.0-3.0 mm, FWHM values of the slice sensitivity profiles were essentially independent of the scan type. For periodic spiral scans, FWHM values measured at the center of the scan range were indistinguishable from those taken 5 mm from one end of the scan range. All CT numbers were within +/- 5 HU, and CT number and noise values were similar for all scan modes assessed. A slight increase in noise and artifact level was observed 5 mm from the start of the scan on the first pass of the periodic spiral. On subsequent passes, noise and artifact level in the transverse and coronal plane images were the same for all scan modes. CONCLUSIONS: Nonconstant velocity periodic spiral scans can achieve z-axis spatial resolution, CT number accuracy, image noise and artifact level equivalent to those for stationary (axial), and constant velocity spiral scans. Thus, periodic spiral scans are expected to allow assessment of four-dimensional CT data for scan lengths greater than the detector width without sacrificing image quality.


Asunto(s)
Algoritmos , Imagenología Tridimensional/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada Espiral/métodos , Humanos , Fantasmas de Imagen , Intensificación de Imagen Radiográfica/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
13.
AJR Am J Roentgenol ; 195(5): 1164-74, 2010 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-20966323

RESUMEN

OBJECTIVE: The objective of this study was to investigate the effect on radiation dose and image quality of the use of additional spectral filtration for dual-energy CT using dual-source CT (DSCT). MATERIALS AND METHODS: A commercial DSCT scanner was modified by adding tin filtration to the high-kV tube, and radiation output and noise were measured in water phantoms. Dose values for equivalent image noise were compared between the dual-energy mode with and without tin filtration and the single-energy mode. To evaluate dual-energy CT material discrimination, the material-specific dual-energy ratio for calcium and that for iodine were determined using images of anthropomorphic phantoms. Data were additionally acquired from imaging a 38-kg pig and an 87-kg pig, and the noise of the linearly mixed images and virtual noncontrast images was compared between dual-energy modes. Finally, abdominal dual-energy CT images of two patients of similar sizes undergoing clinically indicated CT were compared. RESULTS: Adding tin filtration to the high-kV tube improved the dual-energy contrast between iodine and calcium as much as 290%. Data from our animal study showed that tin filtration had no effect on noise in the dual-energy CT mixed images but decreased noise by as much as 30% in the virtual noncontrast images. Virtual noncontrast images of patients acquired using 100 and 140 kV with added tin filtration had improved image quality relative to those generated using 80 and 140 kV without tin filtration. CONCLUSION: Tin filtration of the high-kV tube of a DSCT scanner increases the ability of dual-energy CT to discriminate between calcium and iodine without increasing dose relative to single-energy CT. Furthermore, the use of 100- and 140-kV tube potentials allows improved dual-energy CT imaging of large patients.


Asunto(s)
Estaño , Tomografía Computarizada por Rayos X/métodos , Urografía/métodos , Animales , Calcio , Medios de Contraste , Filtración/métodos , Humanos , Yodo , Fantasmas de Imagen , Dosis de Radiación , Estudios Retrospectivos , Porcinos
14.
AJR Am J Roentgenol ; 195(2): 486-93, 2010 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-20651209

RESUMEN

OBJECTIVE: The purpose of this study was to investigate replacing unenhanced and arterial single-energy CT acquisitions after endovascular aneurysm repair with one dual-energy CT arterial acquisition. SUBJECTS AND METHODS: Thirty patients underwent arterial dual-energy CT (80 and 140 kVp) and venous single-energy CT (120 kVp) after endovascular aneurysm repair, and the radiation doses were compared with those of a standard triple-phase protocol. Both virtual unenhanced and arterial images were generated with dual-energy CT. Images were reviewed clinically for detection of endoleaks and evaluation of stent and calcium appearance. The aortic luminal attenuation on virtual unenhanced CT images was compared with that on previously acquired true unenhanced images. Virtual unenhanced, arterial, and venous images were compared for thrombus attenuation. Single-energy CT and dual-energy CT images were compared for noise. RESULTS: Replacement of two (unenhanced, arterial) of three single-energy CT acquisitions with one dual-energy CT acquisition resulted in 31% radiation dose savings. All images were clinically interpretable. Thoracic (32 +/- 2 vs 35 +/- 4 HU) and abdominal (30 +/- 3 vs 35 +/- 5 HU) aortic attenuation was similar on virtual unenhanced and true unenhanced images. Thrombus attenuation was similar on virtual unenhanced (32 +/- 6 HU), arterial phase (33 +/- 7 HU), and venous phase (34 +/- 6 HU) images. Decreased stent and calcium attenuation was observed at some locations on virtual unenhanced images. Noise in the thoracic (10 +/- 1 HU) and abdominal (12 +/- 2 HU) aorta was lower on virtual unenhanced images than on true unenhanced images (13 +/- 4 HU, 19 +/- 5 HU). Noise was comparable for dual-energy and single-energy CT (thorax, 16 +/- 2 vs 13 +/- 2 HU; abdomen, 21 +/- 3 vs 23 +/- 5 HU). CONCLUSION: Virtual unenhanced and arterial phase images derived from dual-energy CT can replace true unenhanced and arterial phase single-energy CT images in follow-up after endovascular aneurysm repair (except immediately after the procedure), providing comparable diagnostic information with substantial dose savings.


Asunto(s)
Angiografía/métodos , Aneurisma de la Aorta/diagnóstico por imagen , Aneurisma de la Aorta/cirugía , Aortografía/métodos , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Resultado del Tratamiento
15.
J Comput Assist Tomogr ; 34(1): 64-9, 2010 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-20118724

RESUMEN

OBJECTIVE: To compare coronary image quality at temporal resolutions associated with dual-source computed tomography (DSCT; 83 milliseconds) and 64-detector row scanning (165 milliseconds). METHODS: In 30 patients with a heart rate of less than 70 beats per minute, DSCT coronary angiograms were reconstructed at 83- and 165-millisecond temporal resolutions over different cardiac phases. A blinded observer graded coronary quality. RESULTS: The typical DSCT temporal resolution (83 milliseconds) showed a significantly greater quality at end-systole for all coronary vessels and at end-diastole for the right coronary and left anterior descending coronary arteries. For all vessels, the end-diastole produced the highest quality for both temporal resolutions. CONCLUSIONS: Imaging at 83 milliseconds creates superior quality at end-systole for all coronary vessels and at end-diastole for the right coronary and left anterior descending coronary arteries. At low heart rates, end-diastole produces the highest quality at both temporal resolutions.


Asunto(s)
Frecuencia Cardíaca , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Medios de Contraste/administración & dosificación , Electrocardiografía , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Masculino , Persona de Mediana Edad , Intensificación de Imagen Radiográfica/métodos , Estudios Retrospectivos , Ácidos Triyodobenzoicos/administración & dosificación
16.
Skeletal Radiol ; 39(10): 1025-31, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-20419450

RESUMEN

The purpose of this study was to optimize CT arthrography technique and determine if dual energy CT (DECT) can provide any benefit over single energy CT (SECT). Iodinated contrast attenuation at different concentrations was measured using DECT and SECT at different beam energies (140, 120, and 80 kVp). Dose and noise were measured on phantoms at different tube currents. Three bovine femoral condyles with artificially created cartilage defects were scanned with dose-equivalent protocols. Contrast-to-noise ratio (CNR) between cartilage and iodine was measured, and the appearance of cartilage defects was graded by two readers. DECT scans were post-processed for iodine quantification. The beam energy 80 kVp had the highest iodine signal, 50% greater than DECT, 75% greater than 120 kVp, and 100% greater than 140 kVp. Noise was nearly identical for all techniques when dose was matched. The 80 kVp level had the highest CNR, 25% higher than 120 kVp and DECT, and 33% greater than 140 kVp. The 80 kVp technique was also preferred by both readers. DECT iodine quantification was significantly limited by the post-processing application, noise, and beam hardening. In this in-vitro study, the SECT 80 kVp CT arthrography technique was superior to currently performed 120 and 140 kVP SECT techniques and DECT.


Asunto(s)
Artrografía/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Animales , Cadáver , Bovinos , Medios de Contraste , Cuello Femoral/diagnóstico por imagen , Humanos , Técnicas In Vitro , Yohexol/análogos & derivados , Articulación de la Rodilla/diagnóstico por imagen , Variaciones Dependientes del Observador , Fantasmas de Imagen , Intensificación de Imagen Radiográfica/métodos
17.
Radiology ; 253(1): 98-105, 2009 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-19789255

RESUMEN

PURPOSE: To prospectively evaluate the accuracy of computed tomographic (CT) perfusion measurements of renal hemodynamics and function obtained by using images acquired with one-tenth the typical radiation dose and postprocessed with a highly constrained back-projection (HYPR)-local reconstruction (LR) noise-reduction technique. MATERIALS AND METHODS: This study was approved by the institutional Animal Care and Use Committee. Two consecutive CT perfusion acquisitions were performed in 10 anesthetized pigs over 180 seconds by using routine (80 kV, 160 mAs) and one-tenth (80 kV, 16 mAs) dose levels. Images obtained with each acquisition were reconstructed with identical parameters, and the one-tenth dose images were also processed with a HYPR-LR algorithm. Attenuation changes in kidneys were determined as a function of time to form time-attenuation curves (TACs). Extended gamma-variate curve-fitting was performed, and regional perfusion, glomerular filtration rate, and renal blood flow were calculated. Image quality was evaluated (in 10 pigs), and the agreement for renal perfusion and function between the routine dose and the one-tenth dose HYPR-LR images was determined (for 20 kidneys) by using statistical methods. Statistical analysis was performed by using the paired t test, linear regression, and Bland-Altman analysis. RESULTS: TACs obtained with the one-tenth dose were similar to those obtained with the routine dose. Statistical analysis showed that there were no significant differences between the routine dose and the one-tenth dose acquisitions in renal perfusion and hemodynamic values and that there were slight but statistically significant differences in some values with the one-tenth dose HYPR-LR-processed acquisition. The image quality of the one-tenth dose acquisition was improved by using the HYPR-LR algorithm. Linear regression and Bland-Altman plots showed agreement between the images acquired by using the routine dose and those acquired by using the one-tenth dose with HYPR-LR processing. CONCLUSION: A 10-fold dose reduction at renal perfusion CT imaging can be achieved in vivo, without loss of accuracy. The image quality of the one-tenth dose images could be improved to be near that of the routine dose images by using the HYPR-LR noise-reduction algorithm. SUPPLEMENTAL MATERIAL: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.2531081677/-/DC1.


Asunto(s)
Hemodinámica/fisiología , Dosis de Radiación , Circulación Renal/fisiología , Tomografía Computarizada por Rayos X/métodos , Algoritmos , Animales , Medios de Contraste , Femenino , Aumento de la Imagen/métodos , Procesamiento de Imagen Asistido por Computador , Modelos Lineales , Estudios Prospectivos , Interpretación de Imagen Radiográfica Asistida por Computador , Porcinos
18.
Med Phys ; 36(3): 1019-24, 2009 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19378762

RESUMEN

In dual-source dual-energy CT, the images reconstructed from the low- and high-energy scans (typically at 80 and 140 kV, respectively) can be mixed together to provide a single set of nonmaterial-specific images for the purpose of routine diagnostic interpretation. Different from the material-specific information that may be obtained from the dual-energy scan data, the mixed images are created with the purpose of providing the interpreting physician a single set of images that have an appearance similar to that in single-energy images acquired at the same total radiation dose. In this work, the authors used a phantom study to evaluate the image quality of linearly mixed images in comparison to single-energy CT images, assuming the same total radiation dose and taking into account the effect of patient size and the dose partitioning between the low-and high-energy scans. The authors first developed a method to optimize the quality of the linearly mixed images such that the single-energy image quality was compared to the best-case image quality of the dual-energy mixed images. Compared to 80 kV single-energy images for the same radiation dose, the iodine CNR in dual-energy mixed images was worse for smaller phantom sizes. However, similar noise and similar or improved iodine CNR relative to 120 kV images could be achieved for dual-energy mixed images using the same total radiation dose over a wide range of patient sizes (up to 45 cm lateral thorax dimension). Thus, for adult CT practices, which primarily use 120 kV scanning, the use of dual-energy CT for the purpose of material-specific imaging can also produce a set of non-material-specific images for routine diagnostic interpretation that are of similar or improved quality relative to single-energy 120 kV scans.


Asunto(s)
Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Fenómenos Biofísicos , Tamaño Corporal , Humanos , Fantasmas de Imagen , Interpretación de Imagen Radiográfica Asistida por Computador/normas , Tomografía Computarizada por Rayos X/normas , Tomografía Computarizada por Rayos X/estadística & datos numéricos
19.
Med Phys ; 36(5): 1602-9, 2009 May.
Artículo en Inglés | MEDLINE | ID: mdl-19544776

RESUMEN

In principle, dual-energy CT can only accurately decompose a mixture into two materials. To decompose a mixture into three constitute materials using dual-energy CT measurements, a third criteria must be provided to solve for three unknowns with only two spectral measurements. One solution is to assume that the sum of the volumes of three constituent materials is equivalent to the volume of the mixture (i.e., volume conservation), but this is not always true. A more generalized solution is to use the principle of mass conservation, which assumes that the sum of the masses of the three constituent materials is equivalent to the mass of the mixture. In this article, a mass-conservation based, three-material decomposition dual-energy CT algorithm is described and experimental validation of the accuracy of the technique presented. The results demonstrate that the proposed method can accurately measure elemental concentrations under low noise imaging conditions. Clinically, this may be applied to measure the mass fraction of any chemical element in a three-material mixture of solutions without the requirement of volume conservation.


Asunto(s)
Absorciometría de Fotón/métodos , Algoritmos , Intensificación de Imagen Radiográfica/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Humanos , Fantasmas de Imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
20.
Med Phys ; 36(3): 1025-38, 2009 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19378763

RESUMEN

The larger coverage afforded by wider z-axis beams in multidetector CT (MDCT) creates larger cone angles and greater beam divergence, which results in substantial surface dose variation for helical and contiguous axial scans. This study evaluates the variation of absorbed radiation dose in both cylindrical and anthropomorphic phantoms when performing helical or contiguous axial scans. The approach used here was to perform Monte Carlo simulations of a 64 slice MDCT. Simulations were performed with different radiation profiles (simulated beam widths) for a given collimation setting (nominal beam width) and for different pitch values and tube start angles. The magnitude of variation at the surface was evaluated under four different conditions: (a) a homogeneous CTDI phantom with different combinations of pitch and simulated beam widths, (b) a heterogeneous anthropomorphic phantom with one measured beam collimation and various pitch values, (c) a homogeneous CTDI phantom with fixed beam collimation and pitch, but with different tube start angles, and (d) pitch values that should minimize variations of surface dose-evaluated for both homogeneous and heterogeneous phantoms. For the CTDI phantom simulations, peripheral dose patterns showed variation with percent ripple as high as 65% when pitch is 1.5 and simulated beam width is equal to the nominal collimation. For the anterior surface dose on an anthropomorphic phantom, the percent ripple was as high as 40% when the pitch is 1.5 and simulated beam width is equal to the measured beam width. Low pitch values were shown to cause beam overlaps which created new peaks. Different x-ray tube start angles create shifts of the peripheral dose profiles. The start angle simulations showed that for a given table position, the surface dose could vary dramatically with minimum values that were 40% of the peak when all conditions are held constant except for the start angle. The last group of simulations showed that an "ideal" pitch value can be determined which reduces surface dose variations, but this pitch value must take into account the measured beam width. These results reveal the complexity of estimating surface dose and demonstrate a range of dose variability at surface positions for both homogeneous cylindrical and heterogeneous anthropomorphic phantoms. These findings have potential implications for small-sized dosimeter measurements in phantoms, such as with TLDs or small Farmer chambers.


Asunto(s)
Tomografía Computarizada por Rayos X/estadística & datos numéricos , Antropometría , Fenómenos Biofísicos , Humanos , Modelos Teóricos , Método de Montecarlo , Fantasmas de Imagen , Radiometría/instrumentación , Tomografía Computarizada por Rayos X/métodos