Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
1.
J Synchrotron Radiat ; 31(Pt 4): 896-909, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38843003

RESUMEN

Signal-to-noise ratio and spatial resolution are quantitatively analysed in the context of in-line (propagation based) X-ray phase-contrast imaging. It is known that free-space propagation of a coherent X-ray beam from the imaged object to the detector plane, followed by phase retrieval in accordance with Paganin's method, can increase the signal-to-noise in the resultant images without deteriorating the spatial resolution. This results in violation of the noise-resolution uncertainty principle and demonstrates `unreasonable' effectiveness of the method. On the other hand, when the process of free-space propagation is performed in software, using the detected intensity distribution in the object plane, it cannot reproduce the same effectiveness, due to the amplification of photon shot noise. Here, it is shown that the performance of Paganin's method is determined by just two dimensionless parameters: the Fresnel number and the ratio of the real decrement to the imaginary part of the refractive index of the imaged object. The relevant theoretical analysis is performed first, followed by computer simulations and then by a brief test using experimental images collected at a synchrotron beamline. More extensive experimental tests will be presented in the second part of this paper.

2.
Opt Express ; 32(11): 19294-19307, 2024 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-38859067

RESUMEN

Double-slit interference experiments using monochromatic hard X-rays with the energy of 25 keV are presented. The experiments were performed at a synchrotron source with a distance of 110 m between the interferometer and the detector to produce an interference pattern with a sufficiently broad period that could be adequately sampled by a photon-counting detector with 75 micrometre pixels. In the single-particle version of the experiment, over one million image frames with a single registered photon in each one were collected. The sum of these frames showed a clear presence of the interference pattern with the expected period. Subsequent analysis provided an objective estimation of the minimal number of detected photons required to determine, in accordance with the Rose criterion, the presence of the photon interference. Apart from a general theoretical interest, these investigations were aimed at exploring the possibility of medical X-ray phase-contrast imaging in photon-counting regime at minimal radiation doses.

3.
J Synchrotron Radiat ; 29(Pt 3): 602-614, 2022 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-35510993

RESUMEN

Serial crystallography of membrane proteins often employs high-viscosity injectors (HVIs) to deliver micrometre-sized crystals to the X-ray beam. Typically, the carrier medium is a lipidic cubic phase (LCP) media, which can also be used to nucleate and grow the crystals. However, despite the fact that the LCP is widely used with HVIs, the potential impact of the injection process on the LCP structure has not been reported and hence is not yet well understood. The self-assembled structure of the LCP can be affected by pressure, dehydration and temperature changes, all of which occur during continuous flow injection. These changes to the LCP structure may in turn impact the results of X-ray diffraction measurements from membrane protein crystals. To investigate the influence of HVIs on the structure of the LCP we conducted a study of the phase changes in monoolein/water and monoolein/buffer mixtures during continuous flow injection, at both atmospheric pressure and under vacuum. The reservoir pressure in the HVI was tracked to determine if there is any correlation with the phase behaviour of the LCP. The results indicated that, even though the reservoir pressure underwent (at times) significant variation, this did not appear to correlate with observed phase changes in the sample stream or correspond to shifts in the LCP lattice parameter. During vacuum injection, there was a three-way coexistence of the gyroid cubic phase, diamond cubic phase and lamellar phase. During injection at atmospheric pressure, the coexistence of a cubic phase and lamellar phase in the monoolein/water mixtures was also observed. The degree to which the lamellar phase is formed was found to be strongly dependent on the co-flowing gas conditions used to stabilize the LCP stream. A combination of laboratory-based optical polarization microscopy and simulation studies was used to investigate these observations.


Asunto(s)
Glicéridos , Lípidos , Glicéridos/química , Proteínas de la Membrana/química , Viscosidad , Agua/química , Difracción de Rayos X
4.
J Opt Soc Am A Opt Image Sci Vis ; 39(12): C143-C155, 2022 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-36520754

RESUMEN

A unified method for three-dimensional reconstruction of objects from transmission images collected at multiple illumination directions is described. The method may be applicable to experimental conditions relevant to absorption-based, phase-contrast, or diffraction imaging using x rays, electrons, and other forms of penetrating radiation or matter waves. Both the phase retrieval (also known as contrast transfer function correction) and the effect of Ewald sphere curvature (in the cases with a shallow depth of field and significant in-object diffraction) are incorporated in the proposed algorithm and can be taken into account. Multiple scattering is not treated explicitly but can be mitigated as a result of angular averaging that constitutes an essential feature of the method. The corresponding numerical algorithm is based on three-dimensional gridding which allows for fast computational implementation, including a straightforward parallelization. The algorithm can be used with any scanning geometry involving plane-wave illumination. A software code implementing the proposed algorithm has been developed, tested on simulated and experimental image data, and made publicly available.


Asunto(s)
Algoritmos , Tomografía , Programas Informáticos
5.
J Opt Soc Am A Opt Image Sci Vis ; 39(5): 936-947, 2022 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-36215455

RESUMEN

A method is proposed for high-resolution, three-dimensional reconstruction of internal structures of objects from planar transmission images. The described approach can be used with any form of radiation or matter waves, in principle, provided that the depth of field is smaller than the thickness of the sample. The physical optics basis for the method is elucidated, and the reconstruction algorithm is presented in detail. A simulated example demonstrates an application of the method to three-dimensional electron transmission imaging of a nanoparticle under realistic radiation dose and spatial resolution constraints. It is envisaged that the method can be applicable in high-resolution transmission electron microscopy, soft x-ray microscopy, ultrasound imaging, and other areas.


Asunto(s)
Imagenología Tridimensional , Tomografía , Algoritmos , Imagenología Tridimensional/métodos , Microscopía/métodos
6.
Microsc Microanal ; : 1-17, 2022 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-35485646

RESUMEN

A method for three-dimensional reconstruction of objects from defocused images collected at multiple illumination directions in high-resolution transmission electron microscopy is presented. The method effectively corrects for the Ewald sphere curvature by taking into account the in-particle propagation of the electron beam. Numerical simulations demonstrate that the proposed method is capable of accurately reconstructing biological molecules or nanoparticles from high-resolution defocused images under conditions achievable in single-particle electron cryo-microscopy or electron tomography with realistic radiation doses, non-trivial aberrations, multiple scattering, and other experimentally relevant factors. The physics of the method is based on the well-known Diffraction Tomography formalism, but with the phase-retrieval step modified to include a conjugation of the phase (i.e., multiplication of the phase by a negative constant). At each illumination direction, numerically backpropagating the beam with the conjugated phase produces maximum contrast at the location of individual atoms in the molecule or nanoparticle. The resultant algorithm, Conjugated Holographic Reconstruction, can potentially be incorporated into established software tools for single-particle analysis, such as, for example, RELION or FREALIGN, in place of the conventional contrast transfer function correction procedure, in order to account for the Ewald sphere curvature and improve the spatial resolution of the three-dimensional reconstruction.

7.
Eur Radiol ; 30(5): 2740-2750, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-31974689

RESUMEN

OBJECTIVES: To evaluate and compare the image quality of propagation-based phase-contrast computed tomography (PB-CT) using synchrotron radiation and conventional cone-beam breast computed tomography (CBBCT) based on various radiological image quality criteria. METHODS: Eight excised breast tissue samples of various sizes and containing different lesion types were scanned using PB-CT at a synchrotron facility and using CBBCT at a university-affiliated breast imaging centre. PB-CT scans were performed at two different mean glandular dose (MGD) levels: standard (5.8 mGy) and low (1.5 mGy), for comparison with CBBCT scans at the standard MGD (5.8 mGy). Image quality assessment was carried out using six quality criteria and six independent medical imaging experts in a reading room with mammography workstations. The interobserver agreement between readers was evaluated using intraclass correlation coefficient (ICC), and image quality was compared between the two breast imaging modalities using the area under the visual grading characteristic curve (AUCVGC). RESULTS: Interobserver agreement between the readers showed moderate reliability for five image criteria (ICC: ranging from 0.488 to 0.633) and low reliability for one criterion (image noise) (ICC 0.307). For five image quality criteria (overall quality, perceptible contrast, lesion sharpness, normal tissue interfaces, and calcification visibility), both standard-dose PB-CT images (AUCVGC 0.958 to 1, p ≤ .05) and low dose PB-CT images (AUCVGC 0.785 to 0.834, p ≤ .05) were of significantly higher image quality than standard-dose CBBCT images. CONCLUSIONS: Synchrotron-based PB-CT can achieve a significantly higher radiological image quality at a substantially lower radiation dose compared with conventional CBBCT. KEY POINTS: • PB-CT using synchrotron radiation results in higher image quality than conventional CBBCT for breast imaging. • PB-CT using synchrotron radiation requires a lower radiation dose than conventional CBBCT for breast imaging. • PB-CT can help clinicians diagnose patients with breast cancer.


Asunto(s)
Enfermedades de la Mama/diagnóstico , Mama/diagnóstico por imagen , Tomografía Computarizada de Haz Cónico/métodos , Mamografía/métodos , Sincrotrones , Femenino , Humanos , Dosis de Radiación , Reproducibilidad de los Resultados
8.
J Chem Phys ; 152(16): 164118, 2020 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-32357778

RESUMEN

In this paper, we present and review the most recent computational advances in the BERTHA code. BERTHA can be regarded as the state of the art in fully relativistic four-component Dirac-Kohn-Sham (DKS) software. Thanks to the implementation of various parallelization and memory open-ended distribution schemes in combination with efficient "density fitting" algorithms, it greatly reduces the computational burden of four-component DKS calculations. We also report the newly developed OpenMP version of the code, that, together with the berthmod Python module, provides a significant leap forward in terms of usability and applicability of the BERTHA software. Some applications of the recently developed natural orbitals for chemical valence/charge displacement bonding analysis and the real-time time dependent DKS implementation are also reported.

9.
J Synchrotron Radiat ; 25(Pt 5): 1460-1466, 2018 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-30179186

RESUMEN

The aim of this study was to highlight the advantages that propagation-based phase-contrast computed tomography (PB-CT) with synchrotron radiation can provide in breast cancer diagnostics. For the first time, a fresh and intact mastectomy sample from a 60 year old patient was scanned on the IMBL beamline at the Australian Synchrotron in PB-CT mode and reconstructed. The clinical picture was described and characterized by an experienced breast radiologist, who underlined the advantages of providing diagnosis on a PB-CT volume rather than conventional two-dimensional modalities. Subsequently, the image quality was assessed by 11 breast radiologists and medical imaging experts using a radiological scoring system. The results indicate that, with the radiation dose delivered to the sample being equal, the accuracy of a diagnosis made on PB-CT images is significantly higher than one using conventional techniques.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Sincrotrones , Tomografía Computarizada por Rayos X/métodos , Neoplasias de la Mama/cirugía , Femenino , Humanos , Técnicas In Vitro , Mastectomía , Persona de Mediana Edad , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador , Relación Señal-Ruido
10.
J Opt Soc Am A Opt Image Sci Vis ; 34(12): 2251-2260, 2017 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-29240102

RESUMEN

The effectiveness of reconstructive imaging using the homogeneous transport of intensity equation may be regarded as "unreasonable," because it has been shown to significantly increase signal-to-noise ratio while preserving spatial resolution, compared to equivalent conventional absorption-based imaging techniques at the same photon fluence. We reconcile this surprising behavior by analyzing the propagation of noise in typical in-line holography experiments. This analysis indicates that novel imaging techniques may be designed that produce high signal-to-noise images at low radiation doses without sacrificing spatial resolution.

11.
J Opt Soc Am A Opt Image Sci Vis ; 34(9): 1577-1584, 2017 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-29036160

RESUMEN

A reciprocal relationship between the autocovariance of the light intensity in the source plane and in the far-field detector plane is presented in a form analogous to the classical van Cittert-Zernike theorem, but involving intensity correlation functions. A "classical" version of the reciprocity relationship is considered first, based on the assumption of circular Gaussian statistics of the complex amplitudes in the source plane. The result is consistent with the theory of Hanbury Brown-Twiss interferometry, but it is shown to be also applicable to estimation of the source size or the spatial resolution of the detector from the noise power spectrum of flat-field images. An alternative version of the van Cittert-Zernike theorem for intensity correlations is then derived for a quantized electromagnetic beam in a coherent state, which leads to Poisson statistics for the intrinsic intensity of the beam.

12.
Br J Radiol ; 96(1150): 20221189, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37665247

RESUMEN

OBJECTIVES: Propagation-based phase-contrast computed tomography (PB-CT) is a new imaging technique that exploits refractive and absorption properties of X-rays to enhance soft tissue contrast and improve image quality. This study compares image quality of PB-CT and absorption-based CT (AB-CT) for breast imaging while exploring X-ray energy and radiation dose. METHODS: Thirty-nine mastectomy samples were scanned at energy levels of 28-34keV using a flat panel detector at radiation dose levels of 4mGy and 2mGy. Image quality was assessed using signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), spatial resolution (res) and visibility (vis). Statistical analysis was performed to compare PB-CT images against their corresponding AB-CT images scanned at 32keV and 4mGy. RESULTS: The PB-CT images at 4mGy, across nearly all energy levels, demonstrated superior image quality than AB-CT images at the same dose. At some energy levels, the 2mGy PB-CT images also showed better image quality in terms of CNR/Res and vis compared to the 4mGy AB-CT images. At both investigated doses, SNR and SNR/res were found to have a statistically significant difference across all energy levels. The difference in vis was statistically significant at some energy levels. CONCLUSION: This study demonstrates superior image quality of PB-CT over AB-CT, with X-ray energy playing a crucial role in determining image quality parameters. ADVANCES IN KNOWLEDGE: Our findings reveal that standard dose PB-CT outperforms standard dose AB-CT across all image quality metrics. Additionally, we demonstrate that low dose PB-CT can produce superior images compared to standard dose AB-CT in terms of CNR/Res and vis.


Asunto(s)
Neoplasias de la Mama , Humanos , Femenino , Rayos X , Neoplasias de la Mama/diagnóstico por imagen , Mastectomía , Mama/diagnóstico por imagen , Dosis de Radiación , Relación Señal-Ruido , Interpretación de Imagen Radiográfica Asistida por Computador/métodos
13.
J Struct Biol ; 180(1): 132-42, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22683346

RESUMEN

Electron tomography produces highly magnified 3D image volumes useful for investigating the structure and function of cellular components. Image quality is degraded by multiple scattering events and quantum noise, which depend on the angle at which individual tilt projections are collected. We have adapted a biomedical imaging approach to improve image quality by enhancing individual tilt projections prior to volumetric reconstruction. Specifically, we have developed a family of non-linear anisotropic diffusion (NAD) filters parameterized by the tilt angle. We give a quantitative and qualitative evaluation of our pre-processing approach and the NAD filter. We show an improvement in the reconstructed volumes for tomograms generated from both plastic-embedded and cryo-stabilized samples of malaria parasite-infected erythrocytes.


Asunto(s)
Tomografía con Microscopio Electrónico/métodos , Imagenología Tridimensional/métodos , Algoritmos , Anisotropía , Tomografía con Microscopio Electrónico/normas , Eritrocitos/parasitología , Eritrocitos/ultraestructura , Humanos , Imagenología Tridimensional/normas , Plasmodium berghei/ultraestructura , Plasmodium falciparum/ultraestructura , Mejoramiento de la Calidad , Relación Señal-Ruido , Esporozoítos/ultraestructura
14.
Phys Chem Chem Phys ; 13(27): 12368-94, 2011 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-21670843

RESUMEN

We review recent theoretical and computational advances in the full relativistic four-component Dirac-Kohn-Sham (DKS) approach and its application to the calculation of the electronic structure of chemical systems containing many heavy atoms. We describe our implementation of an all-electron DKS approach based on the use of G-spinor basis sets, Hermite Gaussian functions, state-of-the-art density-fitting techniques and memory distributed parallelism. This approach has enormously extended the applicability of the DKS method, including for example large clusters of heavy atoms, and opens the way for future key developments. We examine the current limitations and future possible applications of the DKS approach, including the implementation of four-current density functionals and real-time propagation schemes. This would make possible to describe molecules in strong fields, accurately accounting for relativistic kinematic effects and spin-orbit coupling.

15.
J Med Imaging (Bellingham) ; 8(5): 052108, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34268442

RESUMEN

Purpose: Breast cancer is the most common cancer in women in developing and developed countries and is responsible for 15% of women's cancer deaths worldwide. Conventional absorption-based breast imaging techniques lack sufficient contrast for comprehensive diagnosis. Propagation-based phase-contrast computed tomography (PB-CT) is a developing technique that exploits a more contrast-sensitive property of x-rays: x-ray refraction. X-ray absorption, refraction, and contrast-to-noise in the corresponding images depend on the x-ray energy used, for the same/fixed radiation dose. The aim of this paper is to explore the relationship between x-ray energy and radiological image quality in PB-CT imaging. Approach: Thirty-nine mastectomy samples were scanned at the imaging and medical beamline at the Australian Synchrotron. Samples were scanned at various x-ray energies of 26, 28, 30, 32, 34, and 60 keV using a Hamamatsu Flat Panel detector at the same object-to-detector distance of 6 m and mean glandular dose of 4 mGy. A total of 132 image sets were produced for analysis. Seven observers rated PB-CT images against absorption-based CT (AB-CT) images of the same samples on a five-point scale. A visual grading characteristics (VGC) study was used to determine the difference in image quality. Results: PB-CT images produced at 28, 30, 32, and 34 keV x-ray energies demonstrated statistically significant higher image quality than reference AB-CT images. The optimum x-ray energy, 30 keV, displayed the largest area under the curve ( AUC VGC ) of 0.754 ( p = 0.009 ). This was followed by 32 keV ( AUC VGC = 0.731 , p ≤ 0.001 ), 34 keV ( AUC VGC = 0.723 , p ≤ 0.001 ), and 28 keV ( AUC VGC = 0.654 , p = 0.015 ). Conclusions: An optimum energy range (around 30 keV) in the PB-CT technique allows for higher image quality at a dose comparable to conventional mammographic techniques. This results in improved radiological image quality compared with conventional techniques, which may ultimately lead to higher diagnostic efficacy and a reduction in breast cancer mortalities.

16.
Acad Radiol ; 28(1): e20-e26, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32035759

RESUMEN

RATIONALE AND OBJECTIVES: Propagation-based phase-contrast CT (PB-CT) is an advanced X-ray imaging technology that exploits both refraction and absorption of the transmitted X-ray beam. This study was aimed at optimizing the experimental conditions of PB-CT for breast cancer imaging and examined its performance relative to conventional absorption-based CT (AB-CT) in terms of image quality and radiation dose. MATERIALS AND METHODS: Surgically excised breast mastectomy specimens (n = 12) were scanned using both PB-CT and AB-CT techniques under varying imaging conditions. To evaluate the radiological image quality, visual grading characteristics (VGC) analysis was used in which 11 breast specialist radiologists compared the overall image quality of PB-CT images with respect to the corresponding AB-CT images. The area under the VGC curve was calculated to measure the differences between PB-CT and AB-CT images. RESULTS: The highest radiological quality was obtained for PB-CT images using a 32 keV energy X-ray beam and by applying the Homogeneous Transport of Intensity Equation phase retrieval with the value of its parameter γ set to one-half of the theoretically optimal value for the given materials. Using these optimized conditions, the image quality of PB-CT images obtained at 4 mGy and 2 mGy mean glandular dose was significantly higher than AB-CT images at 4 mGy (AUCVGC = 0.901, p = 0.001 and AUCVGC = 0.819, p = 0.011, respectively). CONCLUSION: PB-CT achieves a higher radiological image quality compared to AB-CT even at a considerably lower mean glandular dose. Successful translation of the PB-CT technique for breast cancer imaging can potentially result in improved breast cancer diagnosis.


Asunto(s)
Neoplasias de la Mama , Mama/diagnóstico por imagen , Neoplasias de la Mama/diagnóstico por imagen , Humanos , Mastectomía , Dosis de Radiación , Tomografía Computarizada por Rayos X
17.
Biochemistry ; 49(31): 6804-11, 2010 Aug 10.
Artículo en Inglés | MEDLINE | ID: mdl-20593810

RESUMEN

The malaria parasite pigment, hemozoin, is a crystal of ferriprotoporphyrin IX (FP-Fe(III)), a product of hemoglobin digestion. Hemozoin formation is essential for FP-Fe(III) detoxification in the parasite; it is the main target of quinoline antimalarials and can modulate immune and inflammation responses. To gain further insight into the likely mechanisms of crystal formation and hemozoin reactivity, we have reanalyzed the crystal structure data for beta-hematin and solved the crystal structure of Plasmodium falciparum hemozoin. The analysis reveals that the structures are very similar and highlights two previously unexplored modes of FP-Fe(III) self-association involving pi-pi interactions that may initiate crystal formation and help to stabilize the extended structure. Hemozoin can be considered to be a crystal composed of pi-pi dimers stabilized by iron-carboxylate linkages. As a result, it is predicted that two surfaces of the crystal would consist of pi-pi dimers with Fe(III) partly exposed to solvent and capable of undergoing redox reactions. Accordingly, we demonstrate that the crystal possesses both general peroxidase activity and the ability to cause lipid oxidation.


Asunto(s)
Hemoproteínas/química , Plasmodium falciparum/química , Multimerización de Proteína , Animales , Cristalización , Cristalografía por Rayos X , Hemoproteínas/fisiología , Peroxidación de Lípido , Peroxidasas , Pigmentos Biológicos
18.
J Appl Crystallogr ; 53(Pt 6): 1603-1612, 2020 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-33304226

RESUMEN

In recent years, X-ray speckle-tracking techniques have emerged as viable tools for wavefront metrology and sample imaging applications. These methods are based on the measurement of near-field images. Thanks to their simple experimental setup, high angular sensitivity and compatibility with low-coherence sources, these methods have been actively developed for use with synchrotron and laboratory light sources. Not only do speckle-tracking techniques give the potential for high-resolution imaging, but they also provide rapid and robust characterization of aberrations of X-ray optical elements, focal spot profiles, and sample position and transmission properties. In order to realize these capabilities, software implementations are required that are equally rapid and robust. To address this need, a software suite has been developed for the ptychographic X-ray speckle-tracking technique, an X-ray speckle-based method suitable for highly divergent wavefields. The software suite is written in Python 3, with an OpenCL back end for GPU and multi-CPU core processing. It is accessible as a Python module, through the command line or through a graphical user interface, and is available as source code under Version 3 or later of the GNU General Public License.

19.
Acta Crystallogr A Found Adv ; 76(Pt 6): 664-676, 2020 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-33125350

RESUMEN

The deterioration of both the signal-to-noise ratio and the spatial resolution in the electron-density distribution reconstructed from diffraction intensities collected at different orientations of a sample is analysed theoretically with respect to the radiation damage to the sample and the variations in the X-ray intensities illuminating different copies of the sample. The simple analytical expressions and numerical estimates obtained for models of radiation damage and incident X-ray pulses may be helpful in planning X-ray free-electron laser (XFEL) imaging experiments and in analysis of experimental data. This approach to the analysis of partially coherent X-ray imaging configurations can potentially be used for analysis of other forms of imaging where the temporal behaviour of the sample and the incident intensity during exposure may affect the inverse problem of sample reconstruction.

20.
Sci Rep ; 10(1): 7890, 2020 May 12.
Artículo en Inglés | MEDLINE | ID: mdl-32398680

RESUMEN

We show that the width of an arbitrary function and the width of the distribution of its values cannot be made arbitrarily small simultaneously. In the case of ergodic stochastic processes, an ensuing uncertainty relationship is then demonstrated for the product of correlation length and variance. A closely related uncertainty principle is also established for the average degree of fourth-order coherence and the spatial width of modes of bosonic quantum fields. However, it is shown that, in the case of stochastic and quantum observables, certain non-classical states with sub-Poissonian statistics, such as for example photon number squeezed states in quantum optics, can overcome the "classical" noise-resolution uncertainty limit. This uncertainty relationship, which is fundamentally different from the Heisenberg and related uncertainty principles, can define an upper limit for the information capacity of communication and imaging systems. It is expected to be useful in a variety of problems in classical and quantum optics and imaging.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA