Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 72
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Cardiovasc Electrophysiol ; 35(3): 557-568, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37870146

RESUMEN

RETRO-mapping was developed to automate activation mapping of atrial fibrillation (AF). We used the algorithm to study the effect of pulmonary vein isolation (PVI) on the frequency of focal, planar, and colliding wavefronts in persistent AF. An AFocusII catheter was placed on the left atrial endocardium to record 3 s of AF at six sites pre and post-PVI in patients undergoing wide circumferential PVI for persistent AF. RETRO-mapping analyzed each segment in 2 ms time windows for evidence of focal, planar, and colliding waveforms and the automated categorizations manually validated. Ten patients were recruited. A total of 360 s of data in 120 segments of 3 s from 60 left atrial locations were analyzed. RETRO-map was highly effective at identifying focal waves and collisions during AF. PVI significantly reduced collision frequency but not focal and planar activation frequency. However, there was a significant reduction in the dispersion of activation directions. Larger studies may help determine factors associated with successful clinical outcome.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Venas Pulmonares/cirugía , Ablación por Catéter/efectos adversos , Atrios Cardíacos , Algoritmos , Resultado del Tratamiento , Recurrencia
2.
J Cardiovasc Electrophysiol ; 34(12): 2552-2562, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37962263

RESUMEN

BACKGROUND: Patients with atrial fibrillation (AF) and likelihood of bleeding can undergo left atrial appendage occlusion (LAAO) as an alternative method of stroke prophylaxis. Short-term anti-thrombotic drugs are used postprocedure to offset the risk of device-related thrombus, evidence for this practice is limited. OBJECTIVES: To investigate optimal postimplant antithrombotic strategy in high bleeding-risk patients. METHODS: Patients with AF and high-risk for both stroke and bleeding undergoing LAAO were advised their perioperative drug therapy by a multidisciplinary physician panel. Those deemed to be at higher risk of bleeding from anti-thrombotic drugs were assigned to minimal treatment with no antithrombotics or Aspirin-alone. The remaining patients received standard care (STG) with a 12 week course of dual-antiplatelets or anticoagulation postimplant. We compared mortality, device-related thrombus, ischemic stroke, and bleeding events during the 90 days postimplant and long-term. Event-free survival was assessed using Kaplan-Meier survival analysis, with logrank testing for statistical significance. RESULTS: Seventy-five patients underwent LAAO of whom 63 patients (84%) had a prior serious bleeding event. The 42 patients on minimal treatment were older (74.3 ± 7.7 vs. 71.2 ± 7.2) with higher HASBLED score (3.6 ± 0.9 vs. 3.3 ± 1.2) than the 33 patients having standard care. There were no device-related thrombi or strokes in either group at 90 days postprocedure; STG had more bleeding events (5/33 vs. 0/42, p = 0.01) with associated deaths (3/33 vs. 0/42, p = 0.05). During long-term follow-up (median 2.2 years), all patients transitioned onto no antithrombotic drugs (43 patients [61%]) or a single-antiplatelet (29 patients [39%]). There was no evidence of early minimal treatment adversely affecting long-term outcomes. CONCLUSIONS: Short-term anti-thrombotic drugs may not be needed after LAAO implant in patients with high bleeding risk and could be harmful. Larger, prospective studies would be warranted to test these findings.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular , Trombosis , Humanos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/tratamiento farmacológico , Apéndice Atrial/cirugía , Estudios Prospectivos , Susceptibilidad a Enfermedades/complicaciones , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Hemorragia/inducido químicamente , Resultado del Tratamiento , Anticoagulantes/efectos adversos
3.
Europace ; 25(3): 1060-1067, 2023 03 30.
Artículo en Inglés | MEDLINE | ID: mdl-36734205

RESUMEN

AIMS: Left bundle branch area pacing (LBBAP) is a promising method for delivering cardiac resynchronization therapy (CRT), but its relative physiological effectiveness compared with His bundle pacing (HBP) is unknown. We conducted a within-patient comparison of HBP, LBBAP, and biventricular pacing (BVP). METHODS AND RESULTS: Patients referred for CRT were recruited. We assessed electrical response using non-invasive mapping, and acute haemodynamic response using a high-precision haemodynamic protocol. Nineteen patients were recruited: 14 male, mean LVEF of 30%. Twelve had time for BVP measurements. All three modalities reduced total ventricular activation time (TVAT), (ΔTVATHBP -43 ± 14 ms and ΔTVATLBBAP -35 ± 20 ms vs. ΔTVATBVP -19 ± 30 ms, P = 0.03 and P = 0.1, respectively). HBP produced a significantly greater reduction in TVAT compared with LBBAP in all 19 patients (-46 ± 15 ms, -36 ± 17 ms, P = 0.03). His bundle pacing and LBBAP reduced left ventricular activation time (LVAT) more than BVP (ΔLVATHBP -43 ± 16 ms, P < 0.01 vs. BVP, ΔLVATLBBAP -45 ± 17 ms, P < 0.01 vs. BVP, ΔLVATBVP -13 ± 36 ms), with no difference between HBP and LBBAP (P = 0.65). Acute systolic blood pressure was increased by all three modalities. In the 12 with BVP, greater improvement was seen with HBP and LBBAP (6.4 ± 3.8 mmHg BVP, 8.1 ± 3.8 mmHg HBP, P = 0.02 vs. BVP and 8.4 ± 8.2 mmHg for LBBAP, P = 0.3 vs. BVP), with no difference between HBP and LBBAP (P = 0.8). CONCLUSION: HBP delivered better ventricular resynchronization than LBBAP because right ventricular activation was slower during LBBAP. But LBBAP was not inferior to HBP with respect to LV electrical resynchronization and acute haemodynamic response.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Humanos , Masculino , Fascículo Atrioventricular , Terapia de Resincronización Cardíaca/efectos adversos , Terapia de Resincronización Cardíaca/métodos , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/terapia , Electrocardiografía/métodos , Resultado del Tratamiento , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Hemodinámica , Estimulación Cardíaca Artificial/métodos
4.
Europace ; 25(10)2023 10 05.
Artículo en Inglés | MEDLINE | ID: mdl-37815462

RESUMEN

AIMS: Left bundle branch pacing (LBBP) can deliver physiological left ventricular activation, but typically at the cost of delayed right ventricular (RV) activation. Right ventricular activation can be advanced through anodal capture, but there is uncertainty regarding the mechanism by which this is achieved, and it is not known whether this produces haemodynamic benefit. METHODS AND RESULTS: We recruited patients with LBBP leads in whom anodal capture eliminated the terminal R-wave in lead V1. Ventricular activation pattern, timing, and high-precision acute haemodynamic response were studied during LBBP with and without anodal capture. We recruited 21 patients with a mean age of 67 years, of whom 14 were males. We measured electrocardiogram timings and haemodynamics in all patients, and in 16, we also performed non-invasive mapping. Ventricular epicardial propagation maps demonstrated that RV septal myocardial capture, rather than right bundle capture, was the mechanism for earlier RV activation. With anodal capture, QRS duration and total ventricular activation times were shorter (116 ± 12 vs. 129 ± 14 ms, P < 0.01 and 83 ± 18 vs. 90 ± 15 ms, P = 0.01). This required higher outputs (3.6 ± 1.9 vs. 0.6 ± 0.2 V, P < 0.01) but without additional haemodynamic benefit (mean difference -0.2 ± 3.8 mmHg compared with pacing without anodal capture, P = 0.2). CONCLUSION: Left bundle branch pacing with anodal capture advances RV activation by stimulating the RV septal myocardium. However, this requires higher outputs and does not improve acute haemodynamics. Aiming for anodal capture may therefore not be necessary.


Asunto(s)
Fascículo Atrioventricular , Estimulación Cardíaca Artificial , Masculino , Humanos , Anciano , Femenino , Estimulación Cardíaca Artificial/métodos , Sistema de Conducción Cardíaco , Hemodinámica , Ventrículos Cardíacos , Electrocardiografía/métodos
5.
Pacing Clin Electrophysiol ; 46(9): 1077-1084, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37594233

RESUMEN

BACKGROUND: The use of left bundle branch area pacing (LBBAP) for bradycardia pacing and cardiac resynchronization is increasing, but implants are not always successful. We prospectively studied consecutive patients to determine whether septal scar contributes to implant failure. METHODS: Patients scheduled for bradycardia pacing or cardiac resynchronization therapy were prospectively enrolled. Recruited patients underwent preprocedural scar assessment by cardiac MRI with late gadolinium enhancement imaging. LBBAP was attempted using a lumenless lead (Medtronic 3830) via a transeptal approach. RESULTS: Thirty-five patients were recruited: 29 male, mean age 68 years, 10 ischemic, and 16 non-ischemic cardiomyopathy. Pacing indication was bradycardia in 26% and cardiac resynchronization in 74%. The lead was successfully deployed to the left ventricular septum in 30/35 (86%) and unsuccessful in the remaining 5/35 (14%). Septal late gadolinium enhancement was significantly less extensive in patients where left septal lead deployment was successful, compared those where it was unsuccessful (median 8%, IQR 2%-18% vs. median 54%, IQR 53%-57%, p < .001). CONCLUSIONS: The presence of septal scar appears to make it more challenging to deploy a lead to the left ventricular septum via the transeptal route. Additional implant tools or alternative approaches may be required in patients with extensive septal scar.


Asunto(s)
Tabique Interventricular , Humanos , Masculino , Anciano , Tabique Interventricular/diagnóstico por imagen , Bradicardia , Cicatriz , Medios de Contraste , Gadolinio
6.
J Cardiovasc Electrophysiol ; 32(2): 428-438, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33345379

RESUMEN

BACKGROUND: His bundle pacing (HBP) is an alternative to biventricular pacing (BVP) for delivering cardiac resynchronization therapy (CRT) in patients with heart failure and left bundle branch block (LBBB). It is not known whether ventricular activation times and patterns achieved by HBP are equivalent to intact conduction systems and not all patients with LBBB are resynchronized by HBP. OBJECTIVE: To compare activation times and patterns of His-CRT with BVP-CRT, LBBB and intact conduction systems. METHODS: In patients with LBBB, noninvasive epicardial mapping (ECG imaging) was performed during BVP and temporary HBP. Intrinsic activation was mapped in all subjects. Left ventricular activation times (LVAT) were measured and epicardial propagation mapping (EPM) was performed, to visualize epicardial wavefronts. Normal activation pattern and a normal LVAT range were determined from normal subjects. RESULTS: Forty-five patients were included, 24 with LBBB and LV impairment, and 21 with normal 12-lead ECG and LV function. In 87.5% of patients with LBBB, His-CRT successfully shortened LVAT by ≥10 ms. In 33.3%, His-CRT resulted in complete ventricular resynchronization, with activation times and patterns indistinguishable from normal subjects. EPM identified propagation discontinuity artifacts in 83% of patients with LBBB. This was the best predictor of whether successful resynchronization was achieved by HBP (logarithmic odds ratio, 2.19; 95% confidence interval, 0.07-4.31; p = .04). CONCLUSION: Noninvasive electrocardiographic mapping appears to identify patients whose LBBB can be resynchronized by HBP. In contrast to BVP, His-CRT may deliver the maximum potential ventricular resynchronization, returning activation times, and patterns to those seen in normal hearts.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Fascículo Atrioventricular , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/terapia , Electrocardiografía , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Humanos , Resultado del Tratamiento , Función Ventricular Izquierda
7.
Europace ; 23(2): 305-312, 2021 02 05.
Artículo en Inglés | MEDLINE | ID: mdl-33083839

RESUMEN

AIMS: Rate adaptation of the action potential ensures spatial heterogeneities in conduction across the myocardium are minimized at different heart rates providing a protective mechanism against ventricular fibrillation (VF) and sudden cardiac death (SCD), which can be quantified by the ventricular conduction stability (V-CoS) test previously described. We tested the hypothesis that patients with a history of aborted SCD due to an underlying channelopathy or cardiomyopathy have a reduced capacity to maintain uniform activation following exercise. METHODS AND RESULTS: Sixty individuals, with (n = 28) and without (n = 32) previous aborted-SCD event underwent electro-cardiographic imaging recordings following exercise treadmill test. These included 25 Brugada syndrome, 13 hypertrophic cardiomyopathy, 12 idiopathic VF, and 10 healthy controls. Data were inputted into the V-CoS programme to calculate a V-CoS score that indicate the percentage of ventricle that showed no significant change in ventricular activation, with a lower score indicating the development of greater conduction heterogeneity. The SCD group, compared to those without, had a lower median (interquartile range) V-CoS score at peak exertion [92.8% (89.8-96.3%) vs. 97.3% (94.9-99.1%); P < 0.01] and 2 min into recovery [95.2% (91.1-97.2%) vs. 98.9% (96.9-99.5%); P < 0.01]. No significant difference was observable later into recovery at 5 or 10 min. Using the lowest median V-CoS scores obtained during the entire recovery period post-exertion, SCD survivors had a significantly lower score than those without for each of the different underlying aetiologies. CONCLUSION: Data from this pilot study demonstrate the potential use of this technique in risk stratification for the inherited cardiac conditions.


Asunto(s)
Muerte Súbita Cardíaca , Fibrilación Ventricular , Muerte Súbita Cardíaca/etiología , Corazón , Humanos , Proyectos Piloto , Factores de Riesgo , Sobrevivientes , Fibrilación Ventricular/diagnóstico
8.
J Cardiovasc Electrophysiol ; 31(11): 2964-2974, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32976636

RESUMEN

AIMS: A prolonged PR interval may adversely affect ventricular filling and, therefore, cardiac function. AV delay can be corrected using right ventricular pacing (RVP), but this induces ventricular dyssynchrony, itself harmful. Therefore, in intermittent heart block, pacing avoidance algorithms are often implemented. We tested His-bundle pacing (HBP) as an alternative. METHODS: Outpatients with a long PR interval (>200 ms) and intermittent need for ventricular pacing were recruited. We measured within-patient differences in high-precision hemodynamics between AV-optimized RVP and HBP, as well as a pacing avoidance algorithm (Managed Ventricular Pacing [MVP]). RESULTS: We recruited 18 patients. Mean left ventricular ejection fraction was 44.3 ± 9%. Mean intrinsic PR interval was 266 ± 42 ms and QRS duration was 123 ± 29 ms. RVP lengthened QRS duration (+54 ms, 95% CI 42-67 ms, p < .0001) while HBP delivered a shorter QRS duration than RVP (-56 ms, 95% CI -67 to -46 ms, p < .0001). HBP did not increase QRS duration (-2 ms, 95% CI -8 to 13 ms, p = .6). HBP improved acute systolic blood pressure by mean of 5.0 mmHg (95% CI 2.8-7.1 mmHg, p < .0001) compared to RVP and by 3.5 mmHg (95% CI 1.9-5.0 mmHg, p = .0002) compared to the pacing avoidance algorithm. There was no significant difference in hemodynamics between RVP and ventricular pacing avoidance (p = .055). CONCLUSIONS: HBP provides better acute cardiac function than pacing avoidance algorithms and RVP, in patients with prolonged PR intervals. HBP allows normalization of prolonged AV delays (unlike pacing avoidance) and does not cause ventricular dyssynchrony (unlike RVP). Clinical trials may be justified to assess whether these acute improvements translate into longer term clinical benefits in patients with bradycardia indications for pacing.


Asunto(s)
Fascículo Atrioventricular , Estimulación Cardíaca Artificial , Algoritmos , Hemodinámica , Humanos , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda
9.
J Cardiovasc Electrophysiol ; 30(9): 1464-1474, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31211473

RESUMEN

BACKGROUND: Conventional mapping techniques during atrial fibrillation (AF) are difficult to apply because of cycle length irregularity. Mapping studies are usually restricted to short durations of AF in limited regions because of the laborious manual annotation of local activation time (LAT). The purpose of this study was to test an automated algorithm to map activation during AF, with comparable accuracy to manual annotation. METHODS: Left atrial (LA) mapping was performed using a 20-pole double loop catheter (AFocusII) in 30-second data segments from 16 patients. The new algorithm (RETRO-Mapping) was designed to detect wavefront propagation between electrodes, and display activating wavefronts on a two-dimensional representation of the catheter. Activation patterns were validated against their bipolar electrograms and with isochronal maps. The mapping protocol was approved by the research ethics committee (13/LO1169 and 14/LO1367). RESULTS: During AF, uniform wavefront activation direction (mean ± SD, degrees) from manually constructed isochronal maps was comparable to RETRO-Propagation Map (RETRO-PM) and RETRO-Automated Direction (RETRO-AD): 1 ± 6.9 for RETRO-PM; and 2 ± 6.6 for RETRO-AD. There was no significant difference in activation direction assigned to 1373 uniform wavefronts during AF when comparing RETRO-PM with RETRO-AD (Bland-Altman mean difference: -0.1 degrees; limits of agreement: -8.0 to 8.3; 95% CI -0.4 to 0.2; (r = 0.01) R2 = < 0.005; P = .77). CONCLUSION: We have developed and validated a new technique to map activation during AF. This technique shows comparable accuracy to that of conventional isochronal mapping with careful manual adjustment of LAT.


Asunto(s)
Algoritmos , Fibrilación Atrial/diagnóstico , Función del Atrio Izquierdo , Catéteres Cardíacos , Técnicas Electrofisiológicas Cardíacas/instrumentación , Atrios Cardíacos/fisiopatología , Procesamiento de Señales Asistido por Computador , Potenciales de Acción , Adulto , Anciano , Fibrilación Atrial/fisiopatología , Automatización , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Factores de Tiempo
10.
Europace ; 21(9): 1422-1431, 2019 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-30820561

RESUMEN

AIMS: Abnormal rate adaptation of the action potential is proarrhythmic but is difficult to measure with current electro-anatomical mapping techniques. We developed a method to rapidly quantify spatial discordance in whole heart activation in response to rate cycle length changes. We test the hypothesis that patients with underlying channelopathies or history of aborted sudden cardiac death (SCD) have a reduced capacity to maintain uniform activation following exercise. METHODS AND RESULTS: Electrocardiographical imaging (ECGI) reconstructs >1200 electrograms (EGMs) over the ventricles from a single beat, providing epicardial whole heart activation maps. Thirty-one individuals [11 SCD survivors; 10 Brugada syndrome (BrS) without SCD; and 10 controls] with structurally normal hearts underwent ECGI vest recordings following exercise treadmill. For each patient, we calculated the relative change in EGM local activation times (LATs) between a baseline and post-exertion phase using custom written software. A ventricular conduction stability (V-CoS) score calculated to indicate the percentage of ventricle that showed no significant change in relative LAT (<10 ms). A lower score reflected greater conduction heterogeneity. Mean variability (standard deviation) of V-CoS score over 10 consecutive beats was small (0.9 ± 0.5%), with good inter-operator reproducibility of V-CoS scores. Sudden cardiac death survivors, compared to BrS and controls, had the lowest V-CoS scores post-exertion (P = 0.011) but were no different at baseline (P = 0.50). CONCLUSION: We present a method to rapidly quantify changes in global activation which provides a measure of conduction heterogeneity and proof of concept by demonstrating SCD survivors have a reduced capacity to maintain uniform activation following exercise.


Asunto(s)
Mapeo del Potencial de Superficie Corporal/métodos , Síndrome de Brugada/fisiopatología , Muerte Súbita Cardíaca , Sistema de Conducción Cardíaco/fisiopatología , Ventrículos Cardíacos/fisiopatología , Corazón/fisiopatología , Estrés Fisiológico/fisiología , Fibrilación Ventricular/fisiopatología , Potenciales de Acción/fisiología , Adulto , Síndrome de Brugada/diagnóstico por imagen , Estudios de Casos y Controles , Electrocardiografía/métodos , Prueba de Esfuerzo , Femenino , Corazón/diagnóstico por imagen , Sistema de Conducción Cardíaco/diagnóstico por imagen , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Procesamiento de Imagen Asistido por Computador , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Procesamiento de Señales Asistido por Computador , Sobrevivientes , Pruebas de Mesa Inclinada , Tomografía Computarizada por Rayos X , Fibrilación Ventricular/diagnóstico por imagen , Dispositivos Electrónicos Vestibles
11.
Pacing Clin Electrophysiol ; 42(2): 257-264, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30569504

RESUMEN

INTRODUCTION: A spontaneous type I electrocardiogram (ECG) pattern and/or unheralded syncope are conventionally used as risk markers for primary prevention of sudden cardiac arrest/death (SCA/SCD) in Brugada syndrome (BrS). In this study, we determine the prevalence of conventional and newer markers of risk in those with and without previous aborted SCA events. METHODS: All patients with BrS were identified at our institute. History of symptoms was obtained from medical tests or from interviews. Other markers of risk were also obtained, such as presence of (1) spontaneous type I pattern, (2) fractionated QRS (fQRS), (3) early repolarization (ER) pattern, (4) late potentials on signal-averaged ECG (SAECG), and (5) response to programmed electrical stimulation. RESULTS: In 133 patients with Bars, 10 (7%) patients (mean age = 39 ± 11 years; nine males) were identified with a previous ventricular fibrillation/ventricular tachycardia episode (n = 8) or requiring cardio-pulmonary resuscitation (n = 2). None of these patients had a prior history of syncope before their SCA event. Only two (20%) patients reported a history of palpitations or dizziness. None had apneic breathing and three (30%) patients had a family history of SCA. From their ECGs, a spontaneous pattern was only found in one (10%) of these patients. Further, 10% of patients had fQRS, 17% had late potentials on SAECG, 20% had deep S waves in lead I, and 10% had an ER pattern in the peripheral leads. No significant differences were observed in the non-SCA group. CONCLUSION: The majority of BrS patients with previous aborted SCA events did not have a spontaneous type I and/or prior history of syncope. Conventional and newer markers of risk appear to only have limited ability to predict SCA.


Asunto(s)
Síndrome de Brugada/complicaciones , Síndrome de Brugada/fisiopatología , Muerte Súbita Cardíaca/etiología , Electrocardiografía , Síncope/etiología , Síncope/fisiopatología , Adulto , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/prevención & control , Femenino , Humanos , Masculino , Persona de Mediana Edad , Prevalencia , Medición de Riesgo , Factores de Riesgo , Sobrevivientes , Síncope/epidemiología
12.
J Cardiovasc Electrophysiol ; 29(3): 404-411, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29341322

RESUMEN

BACKGROUND: Postablation reentrant ATs depend upon conducting isthmuses bordered by scar. Bipolar voltage maps highlight scar as sites of low voltage, but the voltage amplitude of an electrogram depends upon the myocardial activation sequence. Furthermore, a voltage threshold that defines atrial scar is unknown. We used Ripple Mapping (RM) to test whether these isthmuses were anatomically fixed between different activation vectors and atrial rates. METHODS: We studied post-AF ablation ATs where >1 rhythm was mapped. Multipolar catheters were used with CARTO Confidense for high-density mapping. RM visualized the pattern of activation, and the voltage threshold below which no activation was seen. Isthmuses were characterized at this threshold between maps for each patient. RESULTS: Ten patients were studied (Map 1 was AT1; Map 2: sinus 1/10, LA paced 2/10, AT2 with reverse CS activation 3/10; AT2 CL difference 50 ± 30 ms). Point density was similar between maps (Map 1: 2,589 ± 1,330; Map 2: 2,214 ± 1,384; P  =  0.31). RM activation threshold was 0.16 ± 0.08 mV. Thirty-one isthmuses were identified in Map 1 (median 3 per map; width 27 ± 15 mm; 7 anterior; 6 roof; 8 mitral; 9 septal; 1 posterior). Importantly, 7 of 31 (23%) isthmuses were unexpectedly identified within regions without prior ablation. AT1 was treated following ablation of 11/31 (35%) isthmuses. Of the remaining 20 isthmuses, 14 of 16 isthmuses (88%) were consistent between the two maps (four were inadequately mapped). Wavefront collision caused variation in low voltage distribution in 2 of 16 (12%). CONCLUSIONS: The distribution of isthmuses and nonconducting tissue within the ablated left atrium, as defined by RM, appear concordant between rhythms. This could guide a substrate ablative approach.


Asunto(s)
Potenciales de Acción , Fibrilación Atrial/cirugía , Función del Atrio Izquierdo , Ablación por Catéter/efectos adversos , Técnicas Electrofisiológicas Cardíacas , Atrios Cardíacos/cirugía , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/cirugía , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Catéteres Cardíacos , Estimulación Cardíaca Artificial , Técnicas Electrofisiológicas Cardíacas/instrumentación , Femenino , Atrios Cardíacos/fisiopatología , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Taquicardia Supraventricular/etiología , Taquicardia Supraventricular/fisiopatología , Resultado del Tratamiento
13.
Europace ; 20(suppl_3): iii3-iii15, 2018 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-30476057

RESUMEN

AIMS: Atrial fibrillation (AF) wavefront dynamics are complex and difficult to interpret, contributing to uncertainty about the mechanisms that maintain AF. We aimed to investigate the interplay between rotors, wavelets, and focal sources during fibrillation. METHODS AND RESULTS: Arrhythmia wavefront dynamics were analysed for four optically mapped canine cholinergic AF preparations. A bilayer computer model was tuned to experimental preparations, and varied to have (i) fibrosis in both layers or the epicardium only, (ii) different spatial acetylcholine distributions, (iii) different intrinsic action potential duration between layers, and (iv) varied interlayer connectivity. Phase singularities (PSs) were identified and tracked over time to identify rotational drivers. New focal wavefronts were identified using phase contours. Phase singularity density and new wavefront locations were calculated during AF. There was a single dominant mechanism for sustaining AF in each of the preparations, either a rotational driver or repetitive new focal wavefronts. High-density PS sites existed preferentially around the pulmonary vein junctions. Three of the four preparations exhibited stable preferential sites of new wavefronts. Computational simulations predict that only a small number of connections are functionally important in sustaining AF, with new wavefront locations determined by the interplay between fibrosis distribution, acetylcholine concentration, and heterogeneity in repolarization within layers. CONCLUSION: We were able to identify preferential sites of new wavefront initiation and rotational activity, in order to determine the mechanisms sustaining AF. Electrical measurements should be interpreted differently according to whether they are endocardial or epicardial recordings.


Asunto(s)
Potenciales de Acción , Fibrilación Atrial/fisiopatología , Función del Atrio Izquierdo , Fibras Colinérgicas , Atrios Cardíacos/inervación , Frecuencia Cardíaca , Animales , Fibrilación Atrial/diagnóstico , Remodelación Atrial , Simulación por Computador , Modelos Animales de Enfermedad , Perros , Fibrosis , Atrios Cardíacos/patología , Modelos Cardiovasculares , Factores de Tiempo , Imagen de Colorante Sensible al Voltaje
14.
J Cardiovasc Electrophysiol ; 28(12): 1445-1453, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28833757

RESUMEN

INTRODUCTION: We hypothesized that very high-density mapping of typical atrial flutter (AFL) would facilitate a more complete understanding of its circuit. Such very high-density mapping was performed with the RhythmiaTM (Boston Scientific) mapping system using its 64 electrode basket catheter. METHODS AND RESULTS: Data were acquired from 13 patients in AFL. Functional anatomy of the right atrium (RA) was readily identified during mapping including the Crista Terminalis and Eustachian ridge. The leading edge of the activation wavefront was identified without interruption and its conduction velocity (CV) was calculated. CV was not different at the cavotricuspid isthmus (CTI) compared to the remainder of the RA (1.02 vs. 1.03 m/s, P = 0.93). The sawtooth pattern of the surface electrocardiogram (EKG) flutter waves was compared to the position of the dominant wavefront. The downslope of the surface EKG flutter waves represented on average 73% ± 9% of the total flutter cycle length. During the downslope, the activation wavefront traveled significantly further than during the upslope (182 ± 21 milliseconds vs. 68 ± 29 milliseconds, P < 0.0001) with no change in CV between the two phases (0.88 vs. 0.91 m/s, P = 0.79). CONCLUSION: CV at the CTI is not slower than other RA regions during typical AFL. The gradual downslope of the sawtooth EKG  is not due to slow conduction at the CTI suggesting that success of ablation at this site relates to anatomical properties rather than the presence of a "slow isthmus."


Asunto(s)
Aleteo Atrial/fisiopatología , Electrocardiografía/métodos , Sistema de Conducción Cardíaco/fisiopatología , Frecuencia Cardíaca/fisiología , Válvula Tricúspide/fisiopatología , Anciano , Anciano de 80 o más Años , Aleteo Atrial/diagnóstico por imagen , Aleteo Atrial/cirugía , Ablación por Catéter/métodos , Femenino , Sistema de Conducción Cardíaco/diagnóstico por imagen , Sistema de Conducción Cardíaco/cirugía , Humanos , Imagenología Tridimensional/métodos , Masculino , Persona de Mediana Edad , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía
15.
Pacing Clin Electrophysiol ; 38(2): 267-74, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25414088

RESUMEN

BACKGROUND: Quadripolar left ventricular pacing leads permit a variety of pacing configurations from different sites within a coronary vein. There may be advantages to selecting a specific pacing vector. This study examines whether the range of cardiac outputs obtained at cardiac resynchronization therapy (CRT) implantation is greater between different poles within a vein, or greater between two different veins. METHODS AND RESULTS: The cardiac index (CI, L/min/m(2) ) was measured during CRT implantation using a noninvasive cardiac output monitor (NICOM™, Cheetah Medical Inc., Newton Center, MA, USA) and a quadripolar left ventricle (LV) lead, in 22 patients with sinus rhythm. CI was recorded during right atrial-biventricular pacing at 70/min with fixed atrioventricular and ventriculo-ventricular delay, from each LV electrode in one vein, and then from an alternate vein. Phrenic nerve stimulation (PNS) occurred in nine of 15 posterior and three of 21 anterior veins (P = 0.005). At least one electrode in each vein had no PNS. The mean (standard deviation [SD]) difference between best and worst CI within any one vein was 13.1% (±9%). The mean (SD) difference between the best CI in one vein compared to the other was 9.8% (±8%; P = 0.043). In 16 of 22 patients, the range of CI was greater between poles within one vein, rather than between two veins (best of one vein compared to best from the other). In four of 22 patients, the range was greater between veins (P = 0.0003). CONCLUSION: A greater range of CI is found within a single vein than between two different veins. This finding has implications both for the approach to implant technique and postimplant programming and optimization.


Asunto(s)
Gasto Cardíaco , Terapia de Resincronización Cardíaca/métodos , Vasos Coronarios/fisiopatología , Sistema de Conducción Cardíaco/fisiopatología , Insuficiencia Cardíaca/prevención & control , Insuficiencia Cardíaca/fisiopatología , Anciano , Dispositivos de Terapia de Resincronización Cardíaca , Electrodos Implantados , Femenino , Insuficiencia Cardíaca/diagnóstico , Humanos , Masculino , Resultado del Tratamiento
16.
J Stroke Cerebrovasc Dis ; 24(11): e311-3, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26409717

RESUMEN

OBJECTIVE: The aim of the present study was to demonstrate the practical implications of the association between stroke and cardiac arrhythmia. METHODS: We present here a case of cerebellar hemorrhage presenting with nonsustained ventricular tachycardia (NSVT) in a 61-year-old man with no previously known medical problems. RESULTS: The patient was given oral metoprolol, with a significant reduction in the episodes of NSVT. On further examination, there was an ataxic gait and slurred speech, which was reported to be new by the patient and his accompanying partner. A computed tomography scan of the head performed within 3 hours of symptom onset demonstrated an acute cerebellar parenchymal hemorrhage with local mass effect and extension into the fourth ventricle. CONCLUSION: This case acts as a reminder of the association between stroke and cardiac arrhythmia. It is plausible that episodes of NSVT occurred before presentation and were exacerbated by the increased sympathetic activity following the onset of hemorrhage. As such, it is crucial to interpret electrocardiogram investigations in the context of the clinical presentation. Prompt diagnosis is vital to optimizing care.


Asunto(s)
Hemorragia Cerebral/complicaciones , Taquicardia Ventricular/complicaciones , Hemorragia Cerebral/diagnóstico , Electrocardiografía , Humanos , Masculino , Persona de Mediana Edad , Taquicardia Ventricular/diagnóstico , Tomografía Computarizada por Rayos X
17.
Pacing Clin Electrophysiol ; 37(12): 1619-23, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25195808

RESUMEN

BACKGROUND: Patients postpacemaker implant can undergo a full assessment by pacing system programmer (PSP) or a magnet check. The former takes longer, but provides more detailed information; a magnet-mode assessment is faster, but provides only capture data in an asynchronous pacing mode. A magnet-mode assessment alone may be sufficient in most cases, and current clinical practice varies considerably. METHODS: A retrospective single-center assessment of all pacemaker implants receiving PSP and magnet checks between September 2009 and April 2010. Patient records were reviewed. The results of PSP and magnet checks and any subsequent device-related management were noted. RESULTS: A total of 168 patients underwent pacemaker implantation, magnet-mode assessment, and then PSP interrogation during this period. Magnet-mode assessment revealed a problem in only one patient-failure of atrial capture, leading to subsequent atrial lead repositioning. None of the remaining 167 patients have a serious problem at PSP interrogation; six had minor issues at PSP check, none of which required repeat surgical intervention. CONCLUSIONS: The magnet-mode test only provides information on lead capture in an asynchronous pacing mode, which is the most essential data postoperatively. Our study has suggested that a magnet-mode assessment without PSP interrogation may be sufficient in the immediate postimplant assessment of these patients. Routine postimplant PSP interrogation is time consuming, labor intensive, and adds only minimal additional benefit to the safe management of these patients above and beyond a magnet check, coupled with informed assessment of the associated electrocardiogram/rhythm strip, clinical examination, and chest x-ray.


Asunto(s)
Imanes , Marcapaso Artificial , Complicaciones Posoperatorias/diagnóstico , Implantación de Prótesis , Anciano , Diseño de Equipo , Femenino , Humanos , Masculino , Cuidados Posoperatorios , Estudios Retrospectivos
18.
Pacing Clin Electrophysiol ; 37(7): 828-33, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24697669

RESUMEN

BACKGROUND: Radiation exposure is a major concern in cardiac device implantation, especially cardiac resynchronization therapy (CRT) procedures. The RadPad™ (Worldwide Innovations & Technologies, Inc., Kansas City, MO, USA), a radiation-attenuating adhesive drape, has been shown to be beneficial in several clinical settings involving fluoroscopy, but less is known about the actual benefits in CRT procedures. METHODS: Consecutive CRT implants performed with and without a RadPad™ drape over a 10-month period were analyzed. Two thermoluminescent dosimeters (TLDs) were attached to each implanting physician at several locations (adjacent to eyes, center abdomen [outside lead apron], left and right index fingers, and dorsum of the right foot). Results were corrected for background using control TLDs, and normalized to dose-area product (DAP). RESULTS: Thirty-six patients (31 male), 16 with and 20 without the RadPad™, were included in the study. No technical problems were caused by the presence of the radiation-absorbing drape. Time required to position the drape never exceeded 30 seconds, no acute skin reactions were noted, and no radiation-absorbing drape became displaced. Despite a trend toward longer fluoroscopy times and higher DAPs in the radiation-absorbing drape group, radiation exposure was significantly reduced: 65% in the case of the hands and body (P < 0.001), and 40% the eyes (P < 0.01). CONCLUSION: The use of a radiation-absorbing drape results in a significant reduction in radiation dose to the implanting physician during CRT procedures. Not only is the dose to the hands reduced, but also the eye and body doses are significantly reduced. The routine use of radiation-absorbing drapes should be considered for all CRT implant procedures in the light of these findings.


Asunto(s)
Bismuto/uso terapéutico , Dispositivos de Terapia de Resincronización Cardíaca , Terapia de Resincronización Cardíaca , Protección Radiológica/instrumentación , Anciano , Diseño de Equipo , Femenino , Humanos , Masculino , Dosis de Radiación
19.
Eur Heart J Digit Health ; 5(1): 50-59, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38264702

RESUMEN

Aims: Implantable cardioverter defibrillator (ICD) therapies have been associated with increased mortality and should be minimized when safe to do so. We hypothesized that machine learning-derived ventricular tachycardia (VT) cycle length (CL) variability metrics could be used to discriminate between sustained and spontaneously terminating VT. Methods and results: In this single-centre retrospective study, we analysed data from 69 VT episodes stored on ICDs from 27 patients (36 spontaneously terminating VT, 33 sustained VT). Several VT CL parameters including heart rate variability metrics were calculated. Additionally, a first order auto-regression model was fitted using the first 10 CLs. Using features derived from the first 10 CLs, a random forest classifier was used to predict VT termination. Sustained VT episodes had more stable CLs. Using data from the first 10 CLs only, there was greater CL variability in the spontaneously terminating episodes (mean of standard deviation of first 10 CLs: 20.1 ± 8.9 vs. 11.5 ± 7.8 ms, P < 0.0001). The auto-regression coefficient was significantly greater in spontaneously terminating episodes (mean auto-regression coefficient 0.39 ± 0.32 vs. 0.14 ± 0.39, P < 0.005). A random forest classifier with six features yielded an accuracy of 0.77 (95% confidence interval 0.67 to 0.87) for prediction of VT termination. Conclusion: Ventricular tachycardia CL variability and instability are associated with spontaneously terminating VT and can be used to predict spontaneous VT termination. Given the harmful effects of unnecessary ICD shocks, this machine learning model could be incorporated into ICD algorithms to defer therapies for episodes of VT that are likely to self-terminate.

20.
Artículo en Inglés | MEDLINE | ID: mdl-38649588

RESUMEN

BACKGROUND: Ventricular tachycardia (VT) reduces cardiac output through high heart rates, loss of atrioventricular synchrony, and loss of ventricular synchrony. We studied the contribution of each mechanism and explored the potential therapeutic utility of His bundle pacing to improve cardiac output during VT. METHODS: Study 1 aimed to improve the understanding of mechanisms of harm during VT (using pacing simulated VT). In 23 patients with left ventricular impairment, we recorded continuous ECG and beat-by-beat blood pressure measurements. We assessed the hemodynamic impact of heart rate and restoration of atrial and biventricular synchrony. Study 2 investigated novel pacing interventions during clinical VT by evaluating the hemodynamic effects of His bundle pacing at 5 bpm above the VT rate in 10 patients. RESULTS: In Study 1, at progressively higher rates of simulated VT, systolic blood pressure declined: at rates of 125, 160, and 190 bpm, -22.2%, -42.0%, and -58.7%, respectively (ANOVA p < 0.0001). Restoring atrial synchrony alone had only a modest beneficial effect on systolic blood pressure (+ 3.6% at 160 bpm, p = 0.2117), restoring biventricular synchrony alone had a greater effect (+ 9.1% at 160 bpm, p = 0.242), and simultaneously restoring both significantly increased systolic blood pressure (+ 31.6% at 160 bpm, p = 0.0003). In Study 2, the mean rate of clinical VT was 143 ± 21 bpm. His bundle pacing increased systolic blood pressure by + 14.2% (p = 0.0023). In 6 of 10 patients, VT terminated with His bundle pacing. CONCLUSIONS: Restoring atrial and biventricular synchrony improved hemodynamic function in simulated and clinical VT. Conduction system pacing could improve VT tolerability and treatment.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA