Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Transfusion ; 63 Suppl 3: S146-S158, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-37070399

RESUMEN

BACKGROUND: Platelet concentrates (PLT) can be manufactured using a combination of apheresis collection devices and suspension media (plasma or platelet additive solution (PAS)). It is unclear how platelet quality and hemostatic function differ across the current in-use manufacturing methods in the United States. The objective of this study was therefore to compare baseline function of PLT collected using different apheresis collection platforms and storage media. STUDY DESIGN AND METHODS: PLT were collected at two sites with identical protocols (N = 5 per site, N = 10 total per group) on the MCS® + 9000 (Haemonetics; "MCS"), the Trima Accel® 7 (Terumo; "Trima"), and the Amicus Cell Separator (Fresenius Kabi, "Amicus"). MCS PLT were collected into plasma while Trima and Amicus PLT were collected into plasma or PAS (Trima into Isoplate and Amicus into InterSol; yielding groups "TP", "TI" and "AP", "AI", respectively). PLT units were sampled 1 h after collection and assayed to compare cellular counts, biochemistry, and hemostatic function. RESULTS: Differences in biochemistry were most evident between plasma and PAS groups, as anticipated. MCS and TP had the highest clot strength as assessed by viscoelastometry. AI had the lowest thrombin generation capacity. Both TP and TI had the highest responses on platelet aggregometry. AI had the greatest number of microparticles. DISCUSSION: Platelet quality and function differ among collection platforms at baseline. MCS and Trima platelets overall appear to trend toward higher hemostatic function. Future investigations will assess how these differences change throughout storage, and if these in vitro measures are clinically relevant.


Asunto(s)
Plaquetas , Hemostáticos , Humanos , Plaquetoferesis/métodos , Separación Celular , Recuento de Células
2.
Anesthesiology ; 139(1): 77-90, 2023 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-37027803

RESUMEN

BACKGROUND: The use of low-titer group O whole blood is increasing. To reduce wastage, unused units can be converted to packed red blood cells. Supernatant is currently discarded post-conversion; however, it could be a valuable transfusable product. The aim of this study was to evaluate supernatant prepared from late-storage low-titer group O whole blood being converted to red blood cells, hypothesizing it will have higher hemostatic activity compared to fresh never-frozen liquid plasma. METHODS: Low-titer group O whole blood supernatant (n = 12) prepared on storage day 15 was tested on days 15, 21, and 26 and liquid plasma (n = 12) on 3, 15, 21, and 26. Same-day assays included cell counts, rotational thromboelastometry, and thrombin generation. Centrifuged plasma from units was banked for microparticle characterization, conventional coagulation, clot structure, hemoglobin, and additional thrombin generation assays. RESULTS: Low-titer group O whole blood supernatant contained more residual platelets and microparticles compared to liquid plasma. At day 15, low-titer group O whole blood supernatant elicited a faster intrinsic clotting time compared to liquid plasma (257 ± 41 vs. 299 ± 36 s, P = 0.044), and increased clot firmness (49 ± 9 vs. 28 ± 5 mm, P < 0.0001). Low-titer group O whole blood supernatant showed more significant thrombin generation compared to liquid plasma (day 15 endogenous thrombin potential 1,071 ± 315 vs. 285 ± 221 nM·min, P < 0.0001). Flow cytometry demonstrated low-titer group O whole blood supernatant contained significantly more phosphatidylserine and CD41+ microparticles. However, thrombin generation in isolated plasma suggested residual platelets in low-titer group O whole blood supernatant were a greater contributor than microparticles. Additionally, low-titer group O whole blood supernatant and liquid plasma showed no difference in clot structure, despite higher CD61+ microparticle presence. CONCLUSIONS: Plasma supernatant produced from late-storage low-titer group O whole blood shows comparable, if not enhanced, in vitro hemostatic efficacy to liquid plasma.


Asunto(s)
Hemostáticos , Trombina , Trombina/análisis , Hemostasis , Coagulación Sanguínea , Plaquetas , Tromboelastografía
3.
J Thromb Haemost ; 22(4): 1154-1166, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38072374

RESUMEN

BACKGROUND: Platelet (PLT) product transfusion is a life-saving therapy for actively bleeding patients. There is an urgent need to maintain PLT function and extend shelf life to improve outcomes in these patients. Cold-stored PLT (CS-PLT) maintain hemostatic potential better than room temperature-stored PLT (RT-PLT). However, whether function in long-term CS-PLT is maintained under physiological flow regimes and/or determined by cold-induced metabolic changes is unknown. OBJECTIVES: This study aimed to (i) compare the function of RT-PLT and CS-PLT under physiological flow conditions, (ii) determine whether CS-PLT maintain function after 3 weeks of storage, and (iii) identify metabolic pathways associated with the CS-PLT lesion. METHODS: We performed phenotypic and functional assessments of RT- and CS-PLT (22 °C and 4 °C storage, respectively; N = 10 unique donors) at storage days 0, 5, and/or 21 via metabolomics, flow cytometry, aggregation, thrombin generation, viscoelastic testing, and a microfluidic assay to measure primary hemostatic function. RESULTS: Day 21 4 °C PLT formed an occlusive thrombus under arterial shear at a similar rate to day 5 22 °C PLT. Day 21 4 °C PLTs had enhanced thrombin generation capacity compared with day 0 PLT and maintained functionality comparable to day RT-PLT across all assays performed. Key metrics from microfluidic assessment, flow cytometry, thrombin generation, and aggregation were associated with 4 °C storage, and metabolites involved in taurine and purine metabolism significantly correlated with these metrics. Taurine supplementation of PLT during storage improved hemostatic function under flow. CONCLUSION: CS-PLT stored for 3 weeks maintain hemostatic activity, and storage-induced phenotype and function are associated with taurine and purine metabolism.


Asunto(s)
Hemostáticos , Humanos , Trombina/metabolismo , Conservación de la Sangre , Plaquetas/metabolismo , Purinas/metabolismo
4.
PLoS One ; 19(7): e0304231, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38985805

RESUMEN

Trauma is the leading cause of death in individuals up to 45 years of age. Alterations in platelet function are a critical component of trauma-induced coagulopathy (TIC), yet these changes and the potential resulting dysfunction is incompletely understood. The lack of clinical assays available to explore platelet function in this patient population has hindered detailed understanding of the role of platelets in TIC. The objective of this study was to assess trauma patient ex vivo flow-dependent platelet hemostatic capacity in a microfluidic model. We hypothesized that trauma patients would have flow-regime dependent alterations in platelet function. Blood was collected from trauma patients with level I activations (N = 34) within 60 min of hospital arrival, as well as healthy volunteer controls (N = 10). Samples were perfused through a microfluidic model of injury at venous and arterial shear rates, and a subset of experiments were performed after incubation with fluorescent anti-CD41 to quantify platelets. Complete blood counts were performed as well as plasma-based assays to quantify coagulation times, fibrinogen, and von Willebrand factor (VWF). Exploratory correlation analyses were employed to identify relationships with microfluidic hemostatic parameters. Trauma patients had increased microfluidic bleeding times compared to healthy controls. While trauma patient samples were able to deposit a substantial amount of clot in the model injury site, the platelet contribution to microfluidic hemostasis was attenuated. Trauma patients had largely normal hematology and plasma-based coagulation times, yet had elevated D-Dimer and VWF. Venous microfluidic bleeding time negatively correlated with VWF, D-Dimer, and mean platelet volume (MPV), while arterial microfluidic bleeding time positively correlated with oxygenation. Arterial clot growth rate negatively correlated with red cell count, and positively with mean corpuscular volume (MCV). We observed changes in clot composition in trauma patient samples reflected by significantly diminished platelet contribution, which resulted in reduced hemostatic function in a microfluidic model of vessel injury. We observed a reduction in platelet clot contribution under both venous and arterial flow ex vivo in trauma patient samples. While our population was heterogenous and had relatively mild injury severity, microfluidic hemostatic parameters correlated with different patient-specific data depending on the flow setting, indicating potentially differential mechanistic pathways contributing to platelet hemostatic capacity in the context of TIC. These data were generated with the goal of identifying key features of platelet dysfunction in bleeding trauma patients under conditions of flow and to determine if these features correlate with clinically available metrics, thus providing preliminary surrogate markers of physiological platelet dysfunction to be further studied across larger cohorts. Future studies will continue to explore those relationships and further define mechanisms of TIC and their relationship with patient outcomes.


Asunto(s)
Plaquetas , Hemostasis , Microfluídica , Heridas y Lesiones , Humanos , Plaquetas/metabolismo , Masculino , Femenino , Adulto , Heridas y Lesiones/sangre , Heridas y Lesiones/complicaciones , Microfluídica/métodos , Persona de Mediana Edad , Trastornos de la Coagulación Sanguínea/etiología , Trastornos de la Coagulación Sanguínea/sangre , Factor de von Willebrand/metabolismo , Fibrinógeno/metabolismo , Estudios de Casos y Controles , Tiempo de Sangría
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA