Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Card Surg ; 36(9): 3040-3051, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34118080

RESUMEN

BACKGROUND: The coronavirus disease 2019 (COVID-19) pandemic has had an unprecedented impact on health care and cardiac surgery. We report cardiac surgeons' concerns, perceptions, and responses during the COVID-19 pandemic. METHODS: A detailed survey was sent to recruit participating adult cardiac surgery centers in North America. Data regarding cardiac surgeons' perceptions and changes in practice were analyzed. RESULTS: Our study comprises 67 institutions with diverse geographic distribution across North America. Nurses were most likely to be redeployed (88%), followed by advanced care practitioners (69%), trainees (28%), and surgeons (25%). Examining surgeon concerns in regard to COVID-19, they were most worried with exposing their family to COVID-19 (81%), followed by contracting COVID-19 (68%), running out of personal protective equipment (PPE) (28%), and hospital resources (28%). In terms of PPE conservation strategies among users of N95 respirators, nearly half were recycling via decontamination with ultraviolet light (49%), followed by sterilization with heat (13%) and at home or with other modalities (13%). Reuse of N95 respirators for 1 day (22%), 1 week (21%) or 1 month (6%) was reported. There were differences in adoption of methods to conserve N95 respirators based on institutional pandemic phase and COVID-19 burden, with higher COVID-19 burden institutions more likely to resort to PPE conservation strategies. CONCLUSIONS: The present study demonstrates the impact of COVID-19 on North American cardiac surgeons. Our study should stimulate further discussions to identify optimal solutions to improve workforce preparedness for subsequent surges, as well as facilitate the navigation of future healthcare crises.


Asunto(s)
COVID-19 , Cirujanos , Adulto , Descontaminación , Humanos , Pandemias , Percepción , SARS-CoV-2
2.
Catheter Cardiovasc Interv ; 93(1): 149-155, 2019 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-30218488

RESUMEN

OBJECTIVES: To evaluate the association between measurements performed during Medtronic CoreValve (MCV) deployment and paravalvular leak (PVL). BACKGROUND: The MCV can be recaptured and repositioned, allowing the TAVR operator to implant at a more favorable position. The association between angiographic measurements of MCV position while the valve is recapturable and PVL post deployment has not been investigated. METHODS: 493 patients undergoing TAVR with MCV (January 2011-July 2017) were included. PVL was defined as intraprocedural aortic regurgitation that was judged clinically to require balloon postdilation. Depth of the valve at the left coronary cusp (LCC) and noncoronary cusp (NCC) were measured when the valve was 80% deployed. An optimal cutoff value for the ratio LCC/NCC for PVL was identified in 40 patients. Using this cutoff value, the association between LCC/NCC and PVL was then validated in 453 patients. RESULTS: The median LCC/NCC was 1.51 (interquartile range 1.06-1.89).The optimal cutoff value for LCC/NCC was 1.48 (93% sensitivity, 77% specificity, AUC0.85). In the validation group 112 (24.7%) patients had PVL. For LCC/NCC ≥ 1.48, the incidence of PVL was lower compared to LCC/NCC < 1.48 (9.58% vs. 41.78%, P < 0.0001). LCC/NCC of 1.48 had a sensitivity of 79.5% and specificity of 63.6% for PVL (AUC0.72). In a multivariate model, LCC/NCC < 1.48 independently predicted PVL (OR = 6.67, 95% CI 3.96-11.23, P < 0.0001). CONCLUSION: Positioning the MCV such that the LCC/NCC is ≥1.48 may result in less PVL.


Asunto(s)
Insuficiencia de la Válvula Aórtica/prevención & control , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Aortografía , Femenino , Humanos , Masculino , Diseño de Prótesis , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
3.
J Card Surg ; 34(9): 849-853, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31348840

RESUMEN

BACKGROUND: Postoperative bleeding complications are associated with less favorable outcomes in cardiac surgery and contribute to excessive overall healthcare costs. HEMOBLAST (Biom'up, Lyon, France) (HB) is a novel ready-to-use hemostatic powder that consists of porcine collagen, bovine chondroitin sulfate, and human pooled plasma thrombin that may help reduce surgical bleeding. AIMS: The aim of this study was to describe the techniques of application for this new combination powder-based hemostat, HB, and demonstrate its use employing photographs of application methods during cardiac procedures. MATERIALS AND METHODS: The initial 24 procedures in which HB was used at our institution included: left ventricular assist device (LVAD) insertions, lung transplants, heart transplants, aortic valve replacements, coronary artery bypass grafting, and mitral valve repair. RESULTS: Hemostasis was achieved in all cases and there were no instances of mediastinitis, sternal infections, allergic reactions, or 30-day mortality. DISCUSSION: This report describes the best methods of application of HB including use for treatment of mediastinal bleeding in a re-operative procedure in a patient on antiplatelet agents and sternal bleeding during an LVAD insertion. Proper application can facilitate excellent hemostasis using this powder. CONCLUSION: HB is a novel powder-based multiple component hemostatic agent that promotes focal or large area hemostasis. We have presented the techniques of use that are important to the successful application of HB to facilitate hemostasis.


Asunto(s)
Puente de Arteria Coronaria/efectos adversos , Enfermedad de la Arteria Coronaria/cirugía , Hemostasis Quirúrgica/instrumentación , Hemostáticos/farmacología , Hemorragia Posoperatoria/cirugía , Anciano , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad
4.
J Card Surg ; 30(8): 648-50, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26044510

RESUMEN

BACKGROUND: Although extracellular xenograft repair has produced encouraging results when applied to cardiac, valvular, and specific aortic defects, its employment as a tube graft to replace the ascending aorta has not been reported. We describe a patient who underwent resection and replacement of an infected ascending aortic graft with an extracellular matrix conduit. The patient did well, but 14 months later developed a pseudoaneurysm from the staple line used to construct the extracellular matrix conduit. METHODS: The patient underwent a repeat sternotomy and removal of the graft. Because of the increased risk of graft failure, a homograft was felt to be more appropriate in this setting. Ultimately, we were unable to implant the homograft because it was too small for the aortic root; therefore we decided to construct a tubular graft from Cormatrix extracellular matrix (CorMatrix, Roswell, GA, USA). Fourteen months later, he presented with shortness of breath. Computed tomography scan revealed a 3.5 cm pseudoaneurysm of the ascending aorta. It appeared as if there was a disruption of the staple line in the extra cellular matrix graft. The plan was to replace it with a Dacron graft. RESULTS: The Cormatrix graft material was removed and sent for culture and histological analysis. A 28-mm Gel weave graft (Terumo Cardiovascular Systems, Ann Arbor, MI, USA) was implanted. The patient tolerated the procedure well with good hemodynamics. CONCLUSIONS: Our experience suggests that the superior strength, handling characteristics, and resistance to infection make extra cellular matrix scaffold a possible alternative conduit to cryopreserved homografts. Applicability as an aortic conduit merits further investigation to better understand behavior of extra cellular matrix in this situation.


Asunto(s)
Aorta/cirugía , Aneurisma de la Aorta/cirugía , Implantación de Prótesis Vascular/métodos , Matriz Extracelular/trasplante , Andamios del Tejido , Aneurisma Falso , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Reoperación , Esternotomía , Factores de Tiempo , Resultado del Tratamiento
6.
Methodist Debakey Cardiovasc J ; 18(1): 45-47, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35891698

RESUMEN

We describe a 39-year-old man referred for surgical aortic valve replacement for severe symptomatic aortic stenosis. Intraoperative inspection was unexpectedly consistent with marantic endocarditis. Pathology confirmed nonbacterial thrombotic endocarditis. We present high-resolution intraoperative, diagnostic, and pathology images of nonbacterial thrombotic endocarditis in a patient with antiphospholipid syndrome with atypical presentation.


Asunto(s)
Endocarditis no Infecciosa , Endocarditis , Prótesis Valvulares Cardíacas , Adulto , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Endocarditis/diagnóstico , Endocarditis/diagnóstico por imagen , Endocarditis no Infecciosa/diagnóstico por imagen , Endocarditis no Infecciosa/etiología , Endocarditis no Infecciosa/cirugía , Humanos , Masculino
7.
J Cardiothorac Surg ; 17(1): 173, 2022 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-35804449

RESUMEN

BACKGROUND: Papillary muscle rupture due to infective endocarditis is a rare event and proper management of this condition has not been described in the literature. Our case aims to shed light on treatment strategies for these patients using the current guidelines. CASE PRESENTATION: This case presents a 58-year-old male with acute heart failure secondary to papillary muscle rupture. He underwent an en bloc resection of his mitral valve with a bioprosthetic valve replacement. Specimen pathology later showed necrotic papillary muscle due to infective endocarditis. The patient was further treated with antibiotic therapy. He recovered well post-operatively and continued to do well after discharge. CONCLUSION: In patients who present with papillary muscle rupture secondary to infective endocarditis, clinical symptoms should drive the treatment strategy. Despite the etiology, early mitral valve surgery remains treatment of choice for patients who have papillary muscle rupture leading to acute heart failure. Culture-guided prolonged antibiotic treatment is vital in this category of patients, especially those who have a prosthetic valve implanted.


Asunto(s)
Endocarditis Bacteriana , Endocarditis , Insuficiencia Cardíaca , Rotura Cardíaca , Insuficiencia de la Válvula Mitral , Enfermedad Aguda , Endocarditis/complicaciones , Endocarditis Bacteriana/complicaciones , Endocarditis Bacteriana/patología , Endocarditis Bacteriana/cirugía , Insuficiencia Cardíaca/complicaciones , Rotura Cardíaca/complicaciones , Rotura Cardíaca/cirugía , Humanos , Masculino , Persona de Mediana Edad , Insuficiencia de la Válvula Mitral/diagnóstico , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/cirugía , Músculos Papilares/cirugía
8.
Tex Heart Inst J ; 49(4)2022 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-35994342

RESUMEN

A 60-year-old man was about to undergo minimally invasive aortic valve replacement when transesophageal echocardiography revealed an intracardiac mass on the left atrial free wall. Multimodal images from 5 months earlier had shown no mass. We converted the procedure to open surgery. The excised mass resembled a cardiac myxoma but was determined to be a papillary fibroelastoma. This case illustrates that papillary fibroelastomas can form and grow rapidly, warranting alertness for their unexpected discovery before and during cardiac surgical procedures.


Asunto(s)
Fibroelastoma Papilar Cardíaco , Fibroma , Neoplasias Cardíacas , Mixoma , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Ecocardiografía Transesofágica , Fibroma/diagnóstico , Fibroma/cirugía , Neoplasias Cardíacas/diagnóstico , Neoplasias Cardíacas/cirugía , Humanos , Masculino , Persona de Mediana Edad
9.
JACC Case Rep ; 4(22): 1529-1533, 2022 Nov 16.
Artículo en Inglés | MEDLINE | ID: mdl-36444183

RESUMEN

We describe an 88-year-old woman who experienced annular rupture during transcatheter aortic valve replacement despite preventative measures. She underwent Y incision and rectangular patch for the double purpose of repairing the rupture and enlarging the aortic root. We highlight the heart team's role in confronting this potentially catastrophic complication. (Level of Difficulty: Advanced.).

10.
Methodist Debakey Cardiovasc J ; 17(2): e18-e28, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34377353

RESUMEN

Chronic thromboembolic pulmonary hypertension (CTEPH) is an underdiagnosed and undertreated sequelae of acute pulmonary embolism. In this comprehensive review, we provide an introductory overview of CTEPH, highlight recent advances in its diagnostic imaging, and describe the surgical technique for pulmonary thromboendarterectomy (PTE), the only established curative treatment for CTEPH. We also discuss the emerging role of balloon pulmonary angioplasty, both independently and combined with PTE, for patients with inoperable, residual, or refractory pulmonary hypertension post PTE. Finally, we stress the importance of a specialized multidisciplinary team approach to CTEPH patient care and share our approach to optimizing care for these patients.


Asunto(s)
Hipertensión Pulmonar , Embolia Pulmonar , Enfermedad Crónica , Endarterectomía/efectos adversos , Humanos , Hipertensión Pulmonar/diagnóstico , Hipertensión Pulmonar/etiología , Hipertensión Pulmonar/cirugía , Arteria Pulmonar/diagnóstico por imagen , Arteria Pulmonar/cirugía , Embolia Pulmonar/diagnóstico por imagen , Embolia Pulmonar/cirugía
11.
Methodist Debakey Cardiovasc J ; 17(2): 152-156, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34326935

RESUMEN

We describe a 31-year-old woman with pulmonary homograft rupture and ventricular fibrillation arrest complicating a transcatheter pulmonary valve (TPV) procedure. She underwent extracorporeal membrane oxygenation (ECMO) with immediate surgical repair including bioprosthetic pulmonary valve replacement. She had difficulty weaning off ECMO due to hyperacute failure of the valve and ultimately underwent successful hybrid TPV with complete recovery. This case illustrates the importance of the heart team approach during catheter and surgical interventions in adult congenital heart disease.


Asunto(s)
Cardiopatías Congénitas , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Válvula Pulmonar , Reemplazo de la Válvula Aórtica Transcatéter , Adulto , Aloinjertos , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/cirugía , Resultado del Tratamiento , Fibrilación Ventricular/diagnóstico por imagen , Fibrilación Ventricular/etiología
12.
JACC Case Rep ; 1(1): 64-66, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34316746

RESUMEN

A 77-year-old woman presented for assessment of symptomatic mitral regurgitation. Multimodality cardiac imaging revealed severe mitral regurgitation secondary to mitral valve prolapse. Significant mitral annular calcification with dramatic intramyocardial calcification was also incidentally discovered. She was then given a diagnosis of idiopathic cardiac osseous metaplasia and was managed conservatively. (Level of Difficulty: Advanced.).

13.
Contemp Clin Trials ; 78: 140-145, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30634037

RESUMEN

RATIONALE: Minimally invasive cardiac surgery has emerged as a safe alternative to standard cardiac surgery. Minimally invasive coronary surgery (MICS CABG) was developed to allow adequate exposure and complete revascularization in CABG from a small thoracotomy incision without cardiopulmonary bypass. Multiple studies have reported significant shorter length of hospital stay and earlier postoperative physical recovery for MICS CABG patients when compared to sternotomy CABG patients. However, there have been no convincing clinical trials that demonstrate improvement in post-operative quality of life for patients who undergo MICS CABG. STUDY DESIGN: The Minimally Invasive Coronary Surgery compared to Sternotomy Coronary Artery Bypass Grafting (MIST) trial is a multi-centered, prospective randomized controlled trial that compares the quality of life and recovery in the early post-operative period between patients undergoing MICS CABG versus patients undergoing sternotomy CABG. Patients will be randomized either to the MICS CABG group or the sternotomy CABG group, and the target enrollment is 88 patients per group. The primary outcome is quality of life assessment performed by SF-36 questionnaire at 1 month. CONCLUSION: The MIST trial is the first prospective study that compares the quality of life between MICS CABG and sternotomy CABG patients. The results of this trial may enhance the procedural desirability of MICS CABG by patients and provide an incentive for surgeons and institutions to increase the availability of MICS CABG in suitable patients.


Asunto(s)
Puente de Arteria Coronaria/métodos , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Calidad de Vida , Esternotomía/métodos , Toracotomía/métodos , Adolescente , Adulto , Anciano , Emociones , Femenino , Humanos , Tiempo de Internación , Masculino , Salud Mental , Persona de Mediana Edad , Tempo Operativo , Rendimiento Físico Funcional , Complicaciones Posoperatorias/epidemiología , Estudios Prospectivos , Adulto Joven
15.
Methodist Debakey Cardiovasc J ; 13(3): 132-141, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29743998

RESUMEN

Surgical aortic valve replacement is the gold standard procedure to treat patients with severe, symptomatic aortic valve stenosis or insufficiency. Bioprosthetic valves are used for surgical aortic valve replacement with a much greater prevalence than mechanical valves. However, bioprosthetic valves may fail over time because of structural valve deterioration; this often requires intervention due to severe bioprosthetic valve stenosis or regurgitation or a combination of both. In select patients, transcatheter aortic valve replacement is an alternative to surgical aortic valve replacement. Transcatheter valve-in-valve (ViV) replacement is performed by implanting a transcatheter heart valve within a failing bioprosthetic valve. The transcatheter ViV operation is a less invasive procedure compared with reoperative surgical aortic valve replacement, but it has been associated with specific complications and requires extensive preoperative work-up and planning by the heart team. Data from experimental studies and analyses of results from clinical procedures have led to strategies to improve outcomes of these procedures. The type, size, and implant position of the transcatheter valve can be optimized for individual patients with knowledge of detailed dimensions of the surgical valve and radiographic and echocardiographic measurements of the patient's anatomy. Understanding the complexities of the ViV procedure can lead surgeons to make choices during the original surgical valve implantation that can make a future ViV operation more technically feasible years before it is required.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Falla de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Diseño de Prótesis , Recuperación de la Función , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
18.
J Thorac Cardiovasc Surg ; 154(4): 1235-1240, 2017 10.
Artículo en Inglés | MEDLINE | ID: mdl-28610762

RESUMEN

BACKGROUND: The Trifecta valve (St Jude Medical, Inc, St Paul, Minn) was approved for commercial use by the US Food and Drug Administration in 2011. Several isolated cases have been reported since then, describing early structural valve deterioration. We report a case series of 8 Trifecta valve failures, describing patients' clinical substrate and management, and the pathologic characteristics of the explanted valves. METHODS: Trifecta valve failure occurred in 7 patients (8 valves) receiving 19-mm (n = 2), 21-mm (n = 3), 23-mm (n = 1), and 25-mm (n = 2) valves. The mean duration of valve durability was 32 ± 21 months, and the most common lesion was prosthetic regurgitation. The mean Society of Thoracic Surgeons risk score for perioperative mortality at the time of reintervention was 9.75% ± 8.1%. Heart failure exacerbation was the most common presenting symptom. RESULTS: Five patients underwent surgical aortic valve replacement, 2 patients received valve-in-valve transcatheter aortic valve replacement, and 1 patient died of cardiogenic shock before reintervention. The most common pathologic finding in the explanted valves was a tan-yellow fibrofatty circumferential pannus adherent to the inflow portion of the Trifecta valve. CONCLUSIONS: Our findings provide further insights into the pathologic mechanisms leading to early Trifecta valve failure. In addition to tear of the noncoronary cusp of the Trifecta prosthesis described as the most common mechanism in the literature for its failure, circumferential pannus formation composed of fibrofatty tissue in the inflow portion and leaflet calcification concentrated around the posts in the outflow portion are important mechanisms contributing toward early Trifecta valve failure.


Asunto(s)
Válvula Aórtica/cirugía , Bioprótesis/efectos adversos , Enfermedades de las Válvulas Cardíacas/cirugía , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas/efectos adversos , Falla de Prótesis , Anciano , Análisis de Falla de Equipo , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/métodos , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Mortalidad , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Diseño de Prótesis , Estados Unidos
20.
J Pediatr Ophthalmol Strabismus ; 43(2): 102-3, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-16598977

RESUMEN

Optic disc examination with the indirect ophthalmoscope is frequently used in the assessment of pediatric glaucoma cases. If the usual viewing eye-pieces are removed from the headgear and loupes worn instead, then a greatly magnified view of the disc is seen with little change to technique or ease of examination.


Asunto(s)
Glaucoma/diagnóstico , Oftalmoscopios , Oftalmoscopía/métodos , Disco Óptico/patología , Preescolar , Humanos , Lactante
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA