1.
Ear Hear ; 2024 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-38915137

RESUMEN

OBJECTIVES: A wide variety of intraoperative tests are available in cochlear implantation. However, no consensus exists on which tests constitute the minimum necessary battery. We assembled an international panel of clinical experts to develop, refine, and vote upon a set of core consensus statements. DESIGN: A literature review was used to identify intraoperative tests currently used in the field and draft a set of provisional statements. For statement evaluation and refinement, we used a modified Delphi consensus panel structure. Multiple interactive rounds of voting, evaluation, and feedback were conducted to achieve convergence. RESULTS: Twenty-nine provisional statements were included in the original draft. In the first voting round, consensus was reached on 15 statements. Of the 14 statements that did not reach consensus, 12 were revised based on feedback provided by the expert practitioners, and 2 were eliminated. In the second voting round, 10 of the 12 revised statements reached a consensus. The two statements which did not achieve consensus were further revised and subjected to a third voting round. However, both statements failed to achieve consensus in the third round. In addition, during the final revision, one more statement was decided to be deleted due to overlap with another modified statement. CONCLUSIONS: A final core set of 24 consensus statements was generated, covering wide areas of intraoperative testing during CI surgery. These statements may provide utility as evidence-based guidelines to improve quality and achieve uniformity of surgical practice.

2.
PLoS Comput Biol ; 18(5): e1010134, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35622861

RESUMEN

There is a growing interest in biomedical engineering in developing procedures that provide accurate simulations of the neural response to electrical stimulus produced by implants. Moreover, recent research focuses on models that take into account individual patient characteristics. We present a phenomenological computational model that is customized with the patient's data provided by the electrically evoked compound action potential (ECAP) for simulating the neural response to electrical stimulus produced by the electrodes of cochlear implants (CIs). The model links the input currents of the electrodes to the simulated ECAP. Potentials and currents are calculated by solving the quasi-static approximation of the Maxwell equations with the finite element method (FEM). In ECAPs recording, an active electrode generates a current that elicits action potentials in the surrounding auditory nerve fibers (ANFs). The sum of these action potentials is registered by other nearby electrode. Our computational model emulates this phenomenon introducing a set of line current sources replacing the ANFs by a set of virtual neurons (VNs). To fit the ECAP amplitudes we assign a suitable weight to each VN related with the probability of an ANF to be excited. This probability is expressed by a cumulative beta distribution parameterized by two shape parameters that are calculated by means of a differential evolution algorithm (DE). Being the weights function of the current density, any change in the design of the CI affecting the current density produces changes in the weights and, therefore, in the simulated ECAP, which confers to our model a predictive capacity. The results of the validation with ECAP data from two patients are presented, achieving a satisfactory fit of the experimental data with those provided by the proposed computational model.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Potenciales de Acción/fisiología , Implantación Coclear/métodos , Nervio Coclear/fisiología , Simulación por Computador , Estimulación Eléctrica , Potenciales Evocados/fisiología , Potenciales Evocados Auditivos/fisiología , Humanos
3.
Audiol Neurootol ; 27(5): 347-355, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35306487

RESUMEN

INTRODUCTION: Transimpedance measurements from cochlear implant electrodes have the potential to identify anomalous electrode array placement, such as tip fold-over (TFO) or fold-back, basal electrode kinking, or buckling. Analysing transimpedance may thus replace intraoperative or post-operative radiological imaging to detect any potential misplacements. A transimpedance algorithm was previously developed to detect deviations from a normal electrode position with the aim of intraoperatively detecting TFO. The algorithm had been calibrated on 35 forced, tip folded electrode arrays in six temporal bones to determine the threshold criterion required to achieve a sensitivity of 100%. Our primary objective here was to estimate the specificity of this TFO algorithm in patients, in a prospective study, for a series of electrode arrays shown to be normally inserted by post-operative imaging. METHODS: Intracochlear voltages were intraoperatively recorded for 157 ears, using Cochlear's Custom Sound™ EP 5 electrophysiological software (Cochlear Ltd., Sydney, NSW, Australia), for both Nucleus® CI512 and CI532 electrode arrays. The algorithm analysed the recorded 22 × 22 transimpedance matrix (TIM) and results were displayed as a heatmap intraoperatively, only visible to the technician in the operating theatre. After all clinical data were collected, the algorithm was evaluated on the bench. The algorithm measures the transimpedance gradients and corresponding phase angles (θ) throughout the TIM and calculates the gradient phase range. If this was greater than the predetermined threshold, the algorithm classified the electrode array insertion as having a TFO. RESULTS: Five ears had no intraoperative TIM and four anomalous matrices were identified from heatmaps and removed from the specificity analysis. Using the 148 remaining data sets (n = 103 CI532 and n = 45 CI512), the algorithm had an average specificity of 98.6% (95.80%-99.75%). CONCLUSION: The algorithm was found to be an effective screening tool for the identification of TFOs. Its specificity was within acceptable levels and resulted in a positive predictive value of 76%, with an estimated incidence of fold-over of 4% in perimodiolar arrays. This would mean 3 out of 4 cases flagged as a fold-over would be correctly identified by the algorithm, with the other being a false positive. The measurements were applied easily in theatre allowing it to be used as a routine clinical tool for confirming correct electrode placement.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Algoritmos , Cóclea/diagnóstico por imagen , Cóclea/cirugía , Implantación Coclear/métodos , Electrodos Implantados , Humanos , Estudios Prospectivos
4.
Audiol Neurootol ; 25(1-2): 35-41, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31927546

RESUMEN

BACKGROUND: The peripheral vestibular end organ is considered to consist of semi-circular canals (SCC) for detection of angular accelerations and the otoliths for detection of linear accelerations. However, otoliths being phylogenetically the oldest part of the vestibular sensory organs are involved in detection of all motions. SUMMARY: This study elaborates on this property of the otolith organ, as this concept can be of importance for the currently designed vestibular implant devices. Key Message: The analysis of the evolution of the inner ear and examination of clinical examples shows the robustness of the otolith system and inhibition capacity of the SCC. The otolith system must be considered superior to the SCC system as illustrated by evolution, clinical evidence, and physical principles.


Asunto(s)
Membrana Otolítica/fisiología , Reflejo Vestibuloocular/fisiología , Vestíbulo del Laberinto/fisiología , Humanos , Sáculo y Utrículo/fisiología , Canales Semicirculares/fisiología
5.
Audiol Neurootol ; 25(1-2): 79-90, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31801137

RESUMEN

INTRODUCTION: Bilateral vestibulopathy is an important cause of imbalance that is misdiagnosed. The clinical management of patients with bilateral vestibular loss remains difficult as there is no clear evidence for an effective treatment. In this paper, we try to analyze the effect of chronic electrical stimulation and adaptation to electrical stimulation of the vestibular system in humans when stimulating the otolith organ with a constant pulse train to mitigate imbalance due to bilateral vestibular dysfunction (BVD). METHODS: We included 2 patients in our study with BVD according to Criteria Consensus of the Classification Committee of the Bárány Society. Both cases were implanted by using a full-band straight electrode to stimulate the otoliths organs and simultaneously for the cochlear stimulation we use a perimodiolar electrode. RESULTS: In both cases Vestibular and clinical test (video head impulse test, videonistagmography cervical vestibular evoked myogenic potentials, cVEMP and oVEMP), subjective visual vertical test, computerized dynamic posturography, dynamic gait index, Time UP and Go test and dizziness handicap index) were performed. Posture and gait metrics reveal important improvement if compare with preoperartive situation. Oscillopsia, unsteadiness, independence and quality of life improved to almost normal situation. DISCUSSION/CONCLUSION: Prosthetic implantation of the otolith organ in humans is technically feasible. Electrical stimulation might have potential effects on balance and this is stable after 1 year follow-up. This research provides new possibilities for the development of vestibular implants to improve gravito-inertial acceleration sensation, in this case by the otoliths stimulation.


Asunto(s)
Vestibulopatía Bilateral/terapia , Terapia por Estimulación Eléctrica , Pérdida Auditiva Sensorineural/terapia , Membrana Otolítica/fisiopatología , Adulto , Vestibulopatía Bilateral/fisiopatología , Marcha/fisiología , Prueba de Impulso Cefálico , Pérdida Auditiva Sensorineural/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Equilibrio Postural/fisiología , Calidad de Vida , Estudios de Tiempo y Movimiento , Potenciales Vestibulares Miogénicos Evocados/fisiología , Vestíbulo del Laberinto/fisiopatología
6.
Clin Otolaryngol ; 44(2): 138-143, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30354002

RESUMEN

OBJECTIVE: To determine the audiological and clinical results of cochlear implantation in children below the age of 12 years old with congenital and acquired single-sided deafness. DESIGN: Observational, descriptive, transversal study. MAIN OUTCOME MEASURES: Speech reception thresholds, Cortical responses, Auditory Lateralization Test and SSQ questionnaire. PARTICIPANTS: Children < 12 implanted for congenital or acquired SSD. RESULTS: All the children with congenital SSD showed positive cortical responses. Positive results were obtained in the Auditory Lateralization Test for the following modalities: 0º, 45º and 90º. With respect to the Speech Test, the children with acquired SSD showed the following results: 92% and 100% in recognition and 48% and 68% (Azimuth modalities), Signal CI side 52% and 68% and Signal normal hearing side 44% - 60% (p < 0.05). In both group the processor was used for 6-12 hours. With respect to the SSQ questionnaire results, the parents were more satisfied within the post-operative period than within the pre-operative period (P<0.001). CONCLUSIONS: Cochlear implant provides children with congenital SSD with significant audiological and subjective benefits. Children with congenital SSD and implanted after a longer period may not have an important benefit (binaural) although other bilateral effects can be achieved. Children with post-lingual unilateral deafness and after a short period of hearing deprivation probably integrated the normal acoustic hearing with the cochlear implant electrical signal and showed binaural benefits.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Pérdida Auditiva Unilateral/etiología , Pérdida Auditiva Unilateral/terapia , Pérdida Auditiva/congénito , Pérdida Auditiva/terapia , Niño , Preescolar , Femenino , Humanos , Masculino , Localización de Sonidos , Percepción del Habla , Resultado del Tratamiento
7.
Audiol Neurootol ; 23(1): 8-19, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29929187

RESUMEN

OBJECTIVE: To show that patients with unilateral hearing loss (UHL), with one ear fulfilling cochlear implant (CI) indication criteria, and an additional severe tinnitus handicap can be treated effectively with a CI. METHOD: A prospective multi-centre study was conducted in five Spanish centres. Sixteen adult patients with UHL and a mean Tinnitus Handicap Inventory (THI) score of at least 58 were implanted. The study design included repeated within-subject measures of quality of life (Health Utility Index Mark 3 [HUI3]), tinnitus (THI, Visual Analogue Scale [VAS] on tinnitus loudness), hearing (Speech, Spatial, and Qualities of Hearing Scale- [SSQ]), and hyperacusis (Test de Hipersensibilidad al Sonido [THS]) up to 12 months after the initial CI fitting. RESULTS: Group data showed significant subjective benefit from CI treatment: the preoperative HUI3 total utility score of 0.45 went up to 0.57 at 6 months and 0.63 at 12 months; the preoperative THI total score of 75 decreased to 40 at 6 months and 35 at 12 months. The preoperative tinnitus loudness VAS score of 8.2 decreased to 2.4 at 6 months and 2.2 at 12 months with the implant "On" and to 6.7 at 6 months and 6.5 at 12 months with the implant "Off." The preoperative THS total score of 26 decreased to 17 at 12 months. The preoperative SSQ total score of 4.2 increased to 5.1 at 6 months and 6.3 at 12 months. No unanticipated adverse events were reported during the study period. At 12 months after CI activation all subjects (except 1 subject who used the device 6 days a week) wore their devices all day and every day. The primary reason for CI use was split evenly between tinnitus suppression (n = 6) and both hearing and tinnitus (n = 6). CONCLUSION: A CI should be considered as a treatment option in patients with UHL and a concomitant severe tinnitus handicap. However, appropriate counselling of candidates on the anticipated risks, benefits, and limitations that are inherent to cochlear implantation is imperative.


Asunto(s)
Implantes Cocleares , Pérdida Auditiva Unilateral/rehabilitación , Calidad de Vida , Acúfeno/rehabilitación , Adulto , Anciano , Implantación Coclear/métodos , Femenino , Pérdida Auditiva Unilateral/complicaciones , Pruebas Auditivas , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Acúfeno/etiología , Resultado del Tratamiento
8.
Eur Arch Otorhinolaryngol ; 275(6): 1385-1394, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29610960

RESUMEN

OBJECTIVE: The aim of the present study is to evaluate the effect of electrode discrimination based on electrode to modiolus distance in different cochlear implant models, using image information to estimate the outcomes after an implantation on electrode discrimination METHODS: A descriptive prospective randomized study performed during 16 months. A psychoacoustic platform was used to evaluate patients' electrode discrimination capabilities of patients. For the acquisition of the images, a cone beam computed tomography was used to assess postcochlear implantation of electrodes' position. We considered two other new measurements: the intracochlear position index, which indicates how far is the electrode from the modiolar wall, and the homogeneity factor (HF), which provides us with information about the distance between the electrodes and the modiolus RESULTS: 21 postlingually deaf adults showing different CI models [CI522 (n = 7), CI512 (n = 7), and CI532 (n = 7)] that corresponded to the lateral and perimodiolar array electrodes. The average success rate of the CI522 group was 47%, of the CI512 group was 48%, and of the CI532 group was 77%. There is statistically significant difference between groups CI532-CI522 (p = 0.0033) and CI532-CI512 (p = 0.0027) CONCLUSION: The Nucleus CI532 offers a better perimodiolar placement. HF and IPI measurements provide information about the electrodes location inside the cochlea, being related to electrode discrimination.


Asunto(s)
Implantación Coclear/métodos , Implantes Cocleares , Sordera/diagnóstico por imagen , Sordera/terapia , Adolescente , Adulto , Anciano , Percepción Auditiva , Cóclea/diagnóstico por imagen , Cóclea/cirugía , Tomografía Computarizada de Haz Cónico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Psicoacústica , Adulto Joven
9.
Audiol Neurootol ; 22(6): 317-325, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29486475

RESUMEN

As the indications for cochlear implant have expanded to include younger patients and individuals with greater degrees of residual hearing, increasing emphasis has been placed on atraumatic surgery and the preservation of the cochlear structure. Here, a descriptive prospective randomized study was performed. It was shown that residual hearing preservation is possible 12 months postoperatively with an atraumatic perimodiolar flexible electrode array CI532® (Cochlear Ltd, Sydney, Australia). Residual hearing preservation, considered as < 15 dB, was obtained in 70% of the cases. Better clinical outcomes and performance could be obtained compared with the previous perimodiolar CI512®, but further research and a longer follow-up are necessary to verify the impact of outcomes.

10.
Audiol Neurootol ; 21 Suppl 1: 36-42, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27806363

RESUMEN

Cochlear implantation has a significant impact on patients' social life, performance of activities, and self-esteem. The objective of this retrospective study was to assess the health-related quality of life of cochlear implant users aged under and over 60 years by a self-report using the Glasgow Health Status Inventory and the Abbreviated Profile of Hearing Aid Benefit. It was observed that quality of life values increased very rapidly straight after implantation regardless of age. Bilateral cochlear implant users showed better results in environments with background noise and in a reverberant room than unilateral cochlear implant users. Quality of life improved independently of hearing performance benefits for patients over 60 years at implantation.


Asunto(s)
Implantación Coclear/métodos , Estado de Salud , Calidad de Vida , Percepción del Habla , Adolescente , Adulto , Factores de Edad , Anciano , Anciano de 80 o más Años , Implantes Cocleares , Femenino , Humanos , Masculino , Persona de Mediana Edad , Ruido , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven
11.
Audiol Neurootol ; 20 Suppl 1: 60-6, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25997672

RESUMEN

Tinnitus is an incapacitating condition commonly affecting cochlear implant (CI) candidates. The aim of this clinical study is to assess the long-term effects of CI treatment in patients with severe-to-profound, sensorineural, unilateral hearing loss (UHL) and incapacitating tinnitus. We performed a prospective Cochlear™ company-sponsored multicentre study in five Spanish centres. Sixteen patients with UHL and incapacitating tinnitus, which was indicated by a Tinnitus Handicap Inventory (THI) score >58%, received a Nucleus® CI in their deaf ear. The study design includes repeated within-subject measures on hearing, tinnitus, hyperacusis and quality of life up to 12 months after initial CI fitting. In addition to hearing loss and tinnitus, all patients suffered from hyperacusis. Most patients had a sudden hearing loss and received a CI within 2 years after their hearing loss. Preliminary 6-month, post-CI activation data of 13 subjects showed that the majority of patients perceived a subjective benefit from CI treatment, which was assessed using the THI, a Visual Analogue Scale of tinnitus loudness/annoyance and the Speech, Spatial and Qualities of Hearing Scale. Preliminary 12-month data of 7 subjects showed that most patients also perceived a degree of relief from their hyperacusis. One patient showed no improvements in any of the applied scales, which could be explained by partial insertion of the electrode due to obstruction of the cochlea by otosclerosis. In conclusion, CI can successfully be used in the treatment of UHL patients with accompanying severe tinnitus and hyperacusis. Implantation resulted in hearing benefits and a durable relief from tinnitus and hyperacusis in the majority of patients. These findings support the hypothesis that pathophysiological mechanisms after peripheral sensorineural hearing loss are at least partly reversible when hearing is restored with a CI.


Asunto(s)
Implantación Coclear , Pérdida Auditiva Sensorineural/rehabilitación , Pérdida Auditiva Unilateral/rehabilitación , Hiperacusia/rehabilitación , Acúfeno/rehabilitación , Adulto , Anciano , Implantes Cocleares , Femenino , Pérdida Auditiva Sensorineural/complicaciones , Pérdida Auditiva Súbita/complicaciones , Pérdida Auditiva Súbita/rehabilitación , Pérdida Auditiva Unilateral/complicaciones , Humanos , Hiperacusia/complicaciones , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Calidad de Vida , Índice de Severidad de la Enfermedad , Acúfeno/complicaciones , Resultado del Tratamiento
12.
Laryngoscope ; 134(5): 2349-2355, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38010817

RESUMEN

OBJECTIVES: Possible beneficial "crosstalk" during cochlear implant stimulation on otolith end organs has been hypothesized. The aim of this case-control study is to analyze the effect of electrical cochlear stimulation on the vestibule (otolith end-organ), when using a cochleo-vestibular implant, comparing vestibular stimulation (VI) and cochlear stimulation (CI). METHODS: Four patients with bilateral vestibulopathy were included. A double electrode array research implant was implanted in all cases. Dynamic Gait Index (DGI), VOR gain measured by using vestibular head impulse test (vHIT), acoustic cervical myogenic responses (cVEMP) recordings, and electrical cVEMP were used in all cases. Trans-impedance Matrix (TIM) analysis was used to evaluate the current flow from the cochlea to the vestibule. RESULTS: While patients did not have any clinical vestibular improvement with the CI stimulation alone, gait metrics of the patients revealed improvement when the vestibular electrode was stimulated. The average improvement in the DGI was 38% when the vestibular implant was activated, returning to the normal range in all cases. Our findings suggest that any current flow from the cochlear space to the otolith organs was insufficient for effective cross-stimulation. The functional results correlated with the data obtained in TIM analysis, confirming that there is no current flow from the cochlea to the vestibule. CONCLUSION: The only way to produce effective electrical otolith end-organ stimulation, demonstrated with this research implant, is by direct electrical stimulation of the otolith end organs. No effective cross-stimulation was found from cochlear electrode stimulation. LEVEL OF EVIDENCE: 4 Laryngoscope, 134:2349-2355, 2024.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Potenciales Vestibulares Miogénicos Evocados , Vestíbulo del Laberinto , Humanos , Estudios de Casos y Controles , Potenciales Vestibulares Miogénicos Evocados/fisiología , Cóclea , Estimulación Eléctrica
13.
J Clin Med ; 13(13)2024 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-38999362

RESUMEN

Maintaining balance comes naturally to healthy people. In subjects with vestibulopathy, even when compensated, and especially if it is bilateral, maintaining balance requires cognitive effort. Pupillometry is an established method of quantifying cognitive effort. Background/Objectives: We hypothesized that pupillometry would be able to capture the increased effort required to maintain posture in subjects with bilateral vestibulopathy in increasingly difficult conditions. Additionally, we hypothesized that the cognitive workload during balance tasks, indexed by pupil size, would decrease with the activation of the BionicVEST cochleo-vestibular implants. Methods: Subjects with a cochleo-vestibular implant as of March 2023 were recruited, excluding those with ophthalmological issues that precluded pupillometry. Pupillometry was performed using a validated modified videonystagmography system. Computed dynamic posturography and a Modified Clinical Test of Sensory Integration on Balance were performed while the pupil was recorded. Tests were first performed after 24 h of deactivating the vestibular component of the implant. Thereafter, it was reactivated, and after 1 h of rest, the tests were repeated. The pupil recording was processed using custom software and the mean relative pupil diameter (MRPD) was calculated. Results: There was an average of 10.7% to 24.2% reduction in MRPD when the vestibular implant was active, with a greater effect seen in tasks of moderate difficulty, and lesser effect when the task was easy or of great difficulty. Conclusions: Despite technical challenges, pupillometry appears to be a promising method of quantifying the cognitive effort required for maintaining posture in subjects with bilateral vestibulopathy before and after vestibular implantation.

14.
Int J Audiol ; 52(12): 838-48, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23992489

RESUMEN

OBJECTIVES: To investigate the preservation of residual hearing in subjects who received the Nucleus Hybrid L24 cochlear implant. To investigate the performance benefits up to one year post-implantation in terms of speech recognition, sound quality, and quality of life. DESIGN: Prospective, with sequential enrolment and within-subject comparisons. Post-operative performance using a Freedom Hybrid sound processor was compared with that of pre-operative hearing aids. STUDY SAMPLE: Sixty-six adult hearing-impaired subjects with bilateral severe-to-profound high frequency hearing loss. RESULTS: Group median increase in air-conduction thresholds in the implanted ear for test frequencies 125-1000 Hz was < 15 dB across the population; both immediately and one year post-operatively. Eighty-eight percent of subjects used the Hybrid processor at one year post-op. Sixty-five percent of subjects had significant gain in speech recognition in quiet, and 73% in noise (≥ 20 percentage points/2 dB SNR). Mean SSQ subscale scores were significantly improved (+ 1.2, + 1.3, + 1.8 points, p < 0.001), as was mean HUI3 score (+ 0.117, p < 0.01). Combining residual hearing with CI gave 22-26 %age points mean benefit in speech recognition scores over CI alone (p < 0.01). CONCLUSIONS: Useful residual hearing was conserved in 88% of subjects. Speech perception was significantly improved over preoperative hearing aids, as was sound quality and quality of life.


Asunto(s)
Implantación Coclear/instrumentación , Implantes Cocleares , Corrección de Deficiencia Auditiva/instrumentación , Pérdida Auditiva Sensorineural/rehabilitación , Personas con Deficiencia Auditiva/rehabilitación , Adulto , Anciano , Anciano de 80 o más Años , Audiometría de Tonos Puros , Audiometría del Habla , Umbral Auditivo , Europa (Continente) , Femenino , Audición , Pérdida Auditiva Sensorineural/diagnóstico , Pérdida Auditiva Sensorineural/fisiopatología , Pérdida Auditiva Sensorineural/psicología , Humanos , Masculino , Persona de Mediana Edad , Ruido/efectos adversos , Enmascaramiento Perceptual , Personas con Deficiencia Auditiva/psicología , Estudios Prospectivos , Diseño de Prótesis , Calidad de Vida , Reconocimiento en Psicología , Índice de Severidad de la Enfermedad , Inteligibilidad del Habla , Percepción del Habla , Factores de Tiempo , Adulto Joven
15.
J Clin Med ; 12(16)2023 Aug 14.
Artículo en Inglés | MEDLINE | ID: mdl-37629323

RESUMEN

Vestibular medicine "embraces a wide approach to the potential causes of vestibular symptoms, acknowledging that vertigo, dizziness, and unsteadiness are non-specific symptoms that may arise from a broad spectrum of disorders, spanning from the inner ear to the brainstem, cerebellum and supratentorial cerebral networks, to many disorders beyond these structures" [...].

16.
Front Public Health ; 11: 1272437, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38162620

RESUMEN

Introduction: Clinical guidelines for cochlear implants (CI) exist in several countries, however, they lack consistency and often do not encompass the full user journey. This study aims to explore the barriers and facilitators for implementing global Living Guidelines for cochlear implantation in adults with severe, profound or moderate sloping to profound sensorineural hearing loss (SPSNHL) as well as identify guideline implementation (GI) tools that may support uptake. Methods: A convenience sample of Task Force members were recruited for semi-structured interviews. Interview transcripts were thematically analysed to group country-specific barriers, facilitators and GI tools into three levels: health care provider (HCP), consumer and structural. Once identified, barriers and facilitators were classified into four themes related to awareness, economic, guideline or other. Results: Interviews were conducted with 38 Task Force members, representing 20 countries. Lack of CI and hearing loss awareness was a major barrier at the HCP (85% of countries), consumer (80%) and structural (20%) levels. Economic and guideline barriers followed at the HCP (35%; 25%), consumer (45%; 0%) and structural (55%; 30%) levels, respectively. Facilitators focused on raising awareness of hearing loss and CIs as well as guideline related initiates at the HCP (80%; 70%), consumer (70%; 10%) and structural (25%; 70%) levels. GI tools including education, economic evaluations, quick reference resources and social media can help improve awareness and uptake. Conclusion: Awareness is the primary barrier to implementing Living Guidelines globally for adults with SPSNHL. Endorsement from key professional bodies and using the best available evidence can enhance uptake.


Asunto(s)
Implantación Coclear , Pérdida Auditiva , Adulto , Humanos , Adhesión a Directriz , Análisis Costo-Beneficio , Personal de Salud
17.
Med Oral Patol Oral Cir Bucal ; 17(6): e948-55, 2012 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-22926469

RESUMEN

UNLABELLED: Osteonecrosis of the jaws is a clinical entity described and linked to treatment with bisphosphonates in 2003. Its real incidence is unknown and it could increase due to the large number of patients treated with these drugs, and its cumulative effect on the bone. State of the art knowledge regarding its etiopathogeny, clinical course and suitable treatments is limited. OBJECTIVES: To study the clinical characteristics of 44 patients with bisphosphonate-related osteonecrosis of the jaws and the state of their bone mineral metabolism: bone remodeling state, prevalence of fractures, bone mineral density study, and assessment of the different treatment strategies. DESIGN OF THE STUDY: Observational. Information was gathered prospectively through interviews, clinical examinations, additional tests and review of medical records. RESULTS: We studied 16 men and 28 women with a mean age of 64.7 years. Breast cancer was the most frequent underlying disease. Zoledronate was used in 82% of the cases and in the non-oncology group of patients; alendronate was the most frequently used bisphosphonate. The mean duration of the zoledronate and alendronate treatments was 25 months and 88 months respectively. The lower jaw was the most frequent location, and previous exodontias-among the triggering factors known-were the most closely linked to its onset. We found considerable osteoblastic activity in patients suffering from neoplasia, with artifacts present in their bone densitometry and a high percentage of vertebral fractures. CONCLUSIONS: According to our results, osteonecrosis of the jaws affects elderly patients. We found a direct relationship between the duration of exposure and the accumulated dose. Other relevant factors are: Poor oral and dental health, corticoids, diabetes and teeth extractions. In essence, it is a clinical diagnosis. Prevention is the best strategy to handle this clinical entity.


Asunto(s)
Osteonecrosis de los Maxilares Asociada a Difosfonatos/metabolismo , Huesos/metabolismo , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
18.
Acta Otorhinolaryngol Ital ; 42(2): 176-181, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35612510

RESUMEN

Objectives: To investigate the long-term effects of cochlear implants as a treatment for patients with severe to profound neurosensory loss associated with severe tinnitus. Methods: Prospective study in 17 adult patients with severe to profound sensorineural hearing loss associated with severe tinnitus, indicated with a Tinnitus Handicap Inventory (THI) score ≥ 58%, and hyperacusis. Measures were made on hearing, tinnitus, hyperacusis and quality of life up to 5 years after activation of the sound processor of the cochlear implant. It was evaluated by using the disyllabic test, THI, visual analogue scale and Glasgow Benefit Inventory questionnaire. Results: 60 months after cochlear implantation, improvements in loudness and discomfort of tinnitus, speech discrimination and hyperacusis were observed. Subjects perceive an important subjective benefit upon receiving the cochlear implant. Conclusions: Cochlear implants can be used as treatment for patients with severe to profound sensorineural hearing loss associated with severe tinnitus and hyperacusis with long-term benefits on quality of life and lasting relief of tinnitus.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Pérdida Auditiva Sensorineural , Acúfeno , Adulto , Estimulación Eléctrica , Estudios de Seguimiento , Pérdida Auditiva Sensorineural/cirugía , Pérdida Auditiva Sensorineural/terapia , Humanos , Hiperacusia/complicaciones , Hiperacusia/terapia , Estudios Prospectivos , Calidad de Vida , Acúfeno/complicaciones , Acúfeno/terapia , Resultado del Tratamiento
19.
J Int Adv Otol ; 18(6): 465-470, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36349666

RESUMEN

BACKGROUND: The aim of this study was to assess the effect on speech perception and lack of hearing devices gain with surgical masks worn in hearing aid users. METHODS: This prospective cohort study enrolled consecutive patients between November 2020 and February 2021 in a tertiary care medical center from Spain. Fifty-five subjects have been included, 10 as control group, with normal hearing, and 45 patients with sensory-neural hearing loss and hearing aid users, ranging in age between 31 and 83 years old, and were recruited randomized in 4 months. Appropriate test was done previously to check adequate functioning from devices and suitable adaptation. Control group had no hearing impairment neither otologic disease. RESULTS: Disyllabic test in quiet get worse with face mask with a significant difference and stronger impact in noisy background. Age made no difference. Adding lipreading speech perception improved by 95.1 % for younger subjects (<50 years of age) and 91.2% for older subjects (>50 years of age). In the control sample, there was no differences in any condition. CONCLUSION: Despite advantages of wearing mask in preventing coronavirus disease 2019 spread, we must consider that they have also drawbacks for some groups like hearing aid users. In this research, we have not observed high frequencies perception decrease with surgical masks worn, but there was reduction in speech perception, most notably in hearing aids wearers in noisy environment.


Asunto(s)
COVID-19 , Audífonos , Percepción del Habla , Humanos , Preescolar , Niño , Anciano de 80 o más Años , Máscaras , COVID-19/epidemiología , Estudios Prospectivos , Audición
20.
J Clin Med ; 11(19)2022 Sep 27.
Artículo en Inglés | MEDLINE | ID: mdl-36233574

RESUMEN

(1) Background. Patients with bilateral vestibular disease (BVD) experience oscillopsia with a detriment to visual acuity (VA). This VA is driven mainly by the VOR that has two components: rotational and translational. VA can be tested by using dynamic visual acuity (DVA) on a treadmill because both systems are activated. The aim of this study is to compare VA before and after chronic electrical stimulation of the otolith organ. (2) Materials and Method. Five patients suffering from bilateral vestibular dysfunction (BVD), previously implanted with a new vestibular implant prototype, were included in this study with the aim to check VA with and without vestibular implant use (W and W/O) in static, 2 km/h and 4 km/h walking situations. DVAtreadmill was measured on a treadmill with a dynamic illegible E (DIE) test in static and dynamic conditions (while walking on the treadmill at 2 and 4 km/h). The DVA score was registered in a logarithm of the minimum angle of resolution (LogMAR) for each speed. In addition, every patient completed the oscillopsia severity questionnaire (OSQ) and video head impulse test (vHIT) before and after activation of the vestibular implant. (3) Results. The analysis shows a significant difference in OSQ scores and DVA with an improvement in dynamic conditions. Organized corrective saccades during the use of a vestibular implant with no changes in gain were also detected in the video head impulse tests (vHIT). (4) Conclusion. The vestibular implant with otolithic stimulation offers changes in the response of DVA, which makes this paper one of the first to address the possible restoration of it. It is not possible to rule out other contributing factors (presence of covert saccades, somatosensory system, …). More work seems necessary to understand the neurophysiological basis of these findings, but this implant is added as a therapeutic alternative for the improvement of oscillopsia.

SELECCIÓN DE REFERENCIAS