Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Radiologie (Heidelb) ; 2024 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-38985167

RESUMEN

BACKGROUND: The aim of this work was to optimize a three-dimensional (3D) turbo-spin-echo (TSE) sequence using a small field-of-view (FOV) technique for the study of the cerebellopontine angle and to compare it with a constructive interference steady-state (CISS) sequence. METHODS: A total of 30 consecutive patients underwent magnetic resonance imaging with a 3Tesla (T) scanner, including 3D CISS and the optimized 3D small FOV technique turbo spin echo (3D SFT-TSE) T2-weighted sequences for the study of the cerebellopontine angle. The 3D SFT-TSE sequence was optimized after three different steps, and a quantitative evaluation of the signal-to-noise ratio (SNR) was obtained according to the National Electrical Manufacturers Association (NEMA) method. Three neuroradiologists made a blind comparative qualitative evaluation of the images between the 3D CISS and the 3D SFT-TSE obtained after the third optimization step, based on spatial resolution, contrast resolution, and presence of artifacts and noise. RESULTS: The calculation of SNR using the NEMA method confirmed the superiority of the third optimization step over the others. For both spatial and contrast resolution, the optimized SFT-TSE was considered better (p < 0.001) than the CISS, while image artifacts and noise were considered worse in the CISS sequence (p < 0.001). Intraobserver analysis showed that all neuroradiologists preferred the 3D SFT-TSE sequence in terms of both spatial resolution and contrast resolution and found more noise and artifact disruption in the CISS sequence. CONCLUSIONS: The use of the 2D radiofrequency pulse technique with a 3D SFT-TSE T2 sequence was significantly more efficient than the 3D CISS sequence for the study of the cerebellopontine angle and inner ear structures.

2.
J Clin Med ; 13(10)2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38792350

RESUMEN

Background: A relationship between the geometry and symmetry of Willis' circle and intracranial aneurysms was reported for anterior communicating and posterior communicating (PCom) aneurysms. A similar association with the middle cerebral artery (MCA) aneurysms instead appeared weaker. Methods: We reviewed 432 patients from six Italian centers with unilateral MCA aneurysms, analyzing the relationship between the caliber and symmetry of Willis' circle and the presence of ruptured and unruptured presentation. CT-angiograms were evaluated to assess Willis' circle geometrical characteristics and the MCA aneurysm side, dimension and rupture status. Results: The hypoplasia of the first segment of the anterior cerebral artery (A1) was in approximately one-quarter of patients and PCom hypoplasia was in almost 40%. About 9% had a fetal PCom ipsilaterally to the aneurysm. By comparing the aneurysmal and healthy sides, only the PCom hypoplasia appeared significantly higher in the affected side. Finally, the caliber of the internal carotid artery (ICA) and the first segment of MCA (M1) caliber were significantly greater in patients with unruptured aneurysms, and PCom hypoplasia appeared related to the incidence of an ipsilateral MCA aneurysm and its risk of rupture. Conclusions: Although according to these findings asymmetries of Willis' circle are shown to be a risk factor for MCA aneurysm formation and rupture, the indifferent association with ipsilateral or contralateral hypoplasia remains a datum of difficult hemodynamic interpretation, thereby raising the concern that this association may be more casual than causal.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA