1.
Water Sci Technol ; 79(6): 1206-1213, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-31070600

RESUMEN

Combined sewer overflows (CSOs) pollute receiving waters and have a negative impact on ecosystem services. In urban areas rehabilitation of the sewer system to avoid CSOs is associated with high investment costs. Furthermore, not all CSOs can be closed due to the need for hydraulic reliability of the system. Local treatment of CSO with high rate filtration offers an alternative to rehabilitation of the sewer system that is flexible with respect to design and has lower investment cost than separating sewage and storm water runoff. Results from DESSIN, a 4-year EU demonstration project, are presented. The results showed on average 50% removal of particulate matter during CSO events, with higher removal (80%) in the initial first flush period. Other constituents, for example heavy metals, were removed through their association with particles. Potential impacts on ecosystem services in the catchment and the sustainability of the solution were assessed.


Asunto(s)
Eliminación de Residuos Líquidos/métodos , Aguas Residuales/estadística & datos numéricos , Metales Pesados/análisis , Reproducibilidad de los Resultados , Aguas del Alcantarillado , Contaminantes del Agua/análisis
2.
Water Sci Technol ; 71(5): 740-6, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25768221

RESUMEN

Fouling during coagulation-ceramic microfiltration of natural organic matter was investigated. Two process configurations (inline coagulation (IC) and tank coagulation (TC)) and two process conditions (types of coagulants-aluminum-based PAX and iron-based PIX-and G-values) were studied. The rate of irreversible fouling corresponding to the increase of initial transmembrane pressure after backwash of IC-PAX was lowest followed by TC-PAX and TC-PIX, while the performance of IC-PIX was found worst. The 1D and 2D fractal analysis revealed that flocs from IC were morphologically different from those of TC, leading to different filtration characteristics. The 3D fractal analysis revealed two groups of morphologically similar flocs: one led to successful filtration experiments, whereas the other led to unsuccessful ones. Cake porosity was found dependent on the floc morphology. Thus, such an approach was found complementary with fouling analysis by means of a membrane fouling model and minimization of fouling phenomenon was achieved by combining the two approaches.


Asunto(s)
Filtración/instrumentación , Filtración/métodos , Modelos Teóricos , Aluminio , Falla de Equipo , Fractales , Imagenología Tridimensional , Hierro , Membranas Artificiales , Porosidad , Presión , Purificación del Agua/métodos