Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Cathet Cardiovasc Diagn ; 36(3): 269-71, 1995 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-8542640

RESUMEN

A patient was treated by PTA for a tight excentric stenosis in the external iliac artery. Following angioplasty, appropriate placement of a Palmaz stent over the lesion was impossible because of arterial curves and irregular aspect of the residual stenosis. To overcome this problem, the stent was grasped and pulled over the lesion using a snare loop device by contralateral approach.


Asunto(s)
Angioplastia de Balón , Arteriopatías Oclusivas/terapia , Arteria Ilíaca , Stents , Anciano , Arteriopatías Oclusivas/diagnóstico por imagen , Terapia Combinada , Humanos , Arteria Ilíaca/diagnóstico por imagen , Masculino , Radiografía Intervencional
2.
Radiology ; 149(2): 405-10, 1983 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-6353479

RESUMEN

A 14-inch image intensifier designed for digital radiography has made feasible adjunctive evaluation of the renal parenchyma and collecting structures following intravenous digital subtraction angiography (DSA). Initial experiments with rabbits showed digital nephrography to be superior to film-based nephrotomography in terms of renal conspicuity and imaging flexibility. Preliminary experience with 30 patients undergoing DSA reaffirms the suitability of this method for the evaluation of renal anatomy and function. Only about half the amount of contrast material needed for conventional excretory urography is required.


Asunto(s)
Angiografía/métodos , Riñón/diagnóstico por imagen , Urografía/métodos , Animales , Femenino , Humanos , Conejos , Intensificación de Imagen Radiográfica , Circulación Renal , Técnica de Sustracción
3.
Radiology ; 184(3): 833-9, 1992 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-1509075

RESUMEN

Twenty-one patients who underwent percutaneous transluminal angioplasty (PTA) followed by attempted insertion of a self-expandable vascular endoprosthesis for femoropopliteal lesions were prospectively followed up for an average of 17.6 months with angiographic, Doppler ultrasound, and clinical examinations. Stents were placed bilaterally in one patient. Of the 22 lesions, 18 were total occlusions and four, stenoses. Stent placement was successful in 21 of 22 lesions. Nine occlusions occurred: four in the first 30 days and five 1-5 months after PTA. Three patients developed intrastent intimal hyperplasia that necessitated an additional percutaneous procedure. At 12 months, the patency rate without other interventions (the primary patency rate) was 49%. In patients who underwent secondary intervention (fibrinolysis, atherectomy, or PTA), the secondary patency rate was 67%, which fell to 56% after 18 months. At the end of the study, the overall rate of reocclusion was 43%. It is concluded that use of the self-expandable vascular endoprosthesis in the femoropopliteal region likely does not decrease the reocclusion rate after PTA alone. Its use is indicated for treatment of acute closures after femoropopliteal PTA.


Asunto(s)
Arteriopatías Oclusivas/cirugía , Arteria Femoral/cirugía , Arteria Poplítea/cirugía , Stents , Anciano , Arteriopatías Oclusivas/diagnóstico por imagen , Constricción Patológica/diagnóstico por imagen , Constricción Patológica/cirugía , Femenino , Arteria Femoral/diagnóstico por imagen , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Arteria Poplítea/diagnóstico por imagen , Radiografía
4.
J Vasc Interv Radiol ; 7(3): 335-42, 1996.
Artículo en Inglés | MEDLINE | ID: mdl-8761808

RESUMEN

PURPOSE: To report midterm follow-up after implantation of covered stents for hemodialysis access. PATIENTS AND METHODS: Over a 2-year period, a Cragg Endopro stent was placed in 14 patients (mean age, 66.6 years +/- 15) to treat angioplasty-induced ruptures (n = 3), pseudoaneurysm (n = 1), postangioplasty residual stenosis (n = 2), and early restenosis (n = 8, four of them in a Wallstent). RESULTS: Initial placement was successful in all cases. A clinical inflammatory reaction was observed in all three cases of placement in the forearm. When the covered stent was placed in a stenotic vessel, restenosis always occurred within 6 months. Primary and secondary patencies were 28.5% +/- 13.9 and 67.8% +/- 14.5, respectively, at 6 months. Covered stents were of undoubtable benefit in one case of rupture after Wallstent failure and in one case of restenosis in a Wallstent. CONCLUSION: Covered Cragg stents are effective in controlling angioplasty- induced rupture and sometimes for maintaining patency after restenosis in a Wallstent. They do not prevent restenosis and are responsible for an inflammatory reaction of unknown origin and long-term effect.


Asunto(s)
Derivación Arteriovenosa Quirúrgica/instrumentación , Fallo Renal Crónico/terapia , Diálisis Renal , Stents , Anciano , Anciano de 80 o más Años , Angiografía , Falla de Equipo , Femenino , Oclusión de Injerto Vascular/prevención & control , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Reoperación , Propiedades de Superficie
5.
J Vasc Interv Radiol ; 9(4): 639-44, 1998.
Artículo en Inglés | MEDLINE | ID: mdl-9684836

RESUMEN

PURPOSE: To evaluate the efficacy of stent deployment in the treatment of recurrent stenosis of transplant renal arteries (TRAs). PATIENTS AND METHODS: This retrospective study includes six consecutive patients who underwent a mean of 3.66 previous treatments of TRA stenosis per patient before stent implantation (20 angioplasties and two surgical procedures). The endoprostheses were a Wallstent in four patients and a Palmaz stent in two patients. Clinical, laboratory, and duplex scanning follow-up was performed every 6 months after stent placement in all patients. RESULTS: The procedure was a technical success in all patients. At 6 months, mean systolic blood pressure decreased from 179 to 152 mm Hg (P = .018) and mean diastolic blood pressure decreased from 102 to 90 mm Hg (P = .09). Mean serum creatinine level dropped from 269 to 182 mmol/L (P = .03) and the number of antihypertensive drugs per patient decreased from 2.5 to 1.6. At a mean follow-up of 34 months (range, 7-60 months), all TRAs were patent, with a stenosis less than 50% without clinical consequences in one patient. No secondary procedure was necessary. CONCLUSION: Stent placement seems to be an effective treatment of TRA recurrent stenosis. Midterm follow-up shows satisfactory clinical results and TRA patency rates. This technique might be considered as a valuable therapeutic option for the treatment of TRA recurrent stenosis.


Asunto(s)
Trasplante de Riñón , Complicaciones Posoperatorias/terapia , Obstrucción de la Arteria Renal/terapia , Stents , Adulto , Angiografía , Angioplastia de Balón/instrumentación , Diseño de Equipo , Femenino , Estudios de Seguimiento , Humanos , Hipertensión Renovascular/diagnóstico por imagen , Hipertensión Renovascular/terapia , Pruebas de Función Renal , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/diagnóstico por imagen , Recurrencia , Obstrucción de la Arteria Renal/diagnóstico por imagen , Estudios Retrospectivos , Resultado del Tratamiento
6.
J Vasc Interv Radiol ; 9(3): 437-42, 1998.
Artículo en Inglés | MEDLINE | ID: mdl-9618102

RESUMEN

PURPOSE: To report the authors' experience in treatment of ruptures complicating percutaneous transluminal angioplasty (PTA) of hemodialysis access with implantation of a Wallstent. MATERIALS AND METHODS: Between January 1, 1990, and October 1, 1995, the authors performed 2,414 PTAs of angioaccesses. A severe rupture occurred in 40 (1.7%) of these procedures and was treated by means of stent placement. Wallstents were implanted in 37 of these ruptures. The angioaccesses comprised 22 grafts and 15 fistulas. The indications for stent placement were four isolated pseudoaneurysms and 33 cases of bleeding: 15 major leaks, five moderate leaks that persisted despite prolonged inflation at low pressure, seven leaks associated with greater than 50% residual stenosis, four leaks associated with pseudoaneurysm, and two leaks associated with both greater than 50% residual stenosis and pseudoaneurysm. Seventeen ruptures were located on a vein, 19 on the venous anastomosis of a graft, and one on a graft itself. RESULTS: Stent placement stopped the bleeding immediately in 28 cases and after prolonged inflation within the stent in four cases. Residual bleeding required implantation of a covered Cragg stent within the Wallstent in one case. A pseudoaneurysm was still visible at the end of the intervention in 11 cases. Two complications occurred; one hematoma was drained surgically and one access occluded on day 2. Follow-up angiography showed a small pseudoaneurysm in only one patient with impaired platelet function. The primary and secondary patency of the angioaccesses were 48% and 86% at 1 year, respectively. CONCLUSION: Wallstent implantation is very effective for both immediate and long-term treatment of rupture of angioaccess during PTA.


Asunto(s)
Angioplastia de Balón , Oclusión de Injerto Vascular/terapia , Diálisis Renal , Stents , Angioplastia de Balón/efectos adversos , Derivación Arteriovenosa Quirúrgica , Femenino , Estudios de Seguimiento , Oclusión de Injerto Vascular/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Radiografía , Rotura , Factores de Tiempo , Resultado del Tratamiento , Grado de Desobstrucción Vascular/fisiología
7.
Cathet Cardiovasc Diagn ; 28(4): 339-41, 1993 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-8462085

RESUMEN

A case of traumatic arteriovenous fistula and false aneurysm of the internal mammary artery was encountered following sternal wire insertion during cardiac surgery. The diagnosis was suspected by echo-doppler and confirmed by arteriography allowing percutaneous embolization using cyanoacrylate in the same setting.


Asunto(s)
Aneurisma Falso/terapia , Fístula Arteriovenosa/terapia , Hilos Ortopédicos , Embolización Terapéutica , Arterias Mamarias/lesiones , Complicaciones Posoperatorias/terapia , Aneurisma Falso/etiología , Fístula Arteriovenosa/etiología , Enbucrilato , Femenino , Humanos , Anastomosis Interna Mamario-Coronaria , Persona de Mediana Edad , Esternón/cirugía
8.
Radiology ; 198(2): 481-6, 1996 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-8596853

RESUMEN

PURPOSE: To assess the safety and efficacy of secondary procedures in iliac artery stents. MATERIALS AND METHODS: Thirty-four patients (36 limbs) underwent one or more interventional procedures in iliac artery stents to treat restenosis (n = 30) or occlusion (n = 6). All patients were followed up by means of clinical and angiographic examination. Primary and secondary patency were assessed with angiography, duplex ultrasound, or both. Primary patency was determined after one interventional procedure, and secondary patency was determined at the end of the study (mean +/- standard deviation, 20.1 months +/- 17.5; range, 1-58 months). RESULTS: Immediate angiographic success was achieved in all cases. Four complications were observed. The primary and secondary cumulative patency rates were 77.5% +/- 7.6 and 94% +/- 4.1 at 6 months, 73% +/- 8.4 and 89.3% +/- 6 at 12 months, and 51.4% +/- 10.9 and 78.8% +/- 8.8 at 2 years. At the end of the study, 80% of the arteries were still nominally patent. CONCLUSION: Restenosis and chronic occlusion in iliac artery stents can be treated with percutaneous interventional procedures; however, stenosis can still recur.


Asunto(s)
Angioplastia de Balón , Arteriopatías Oclusivas/terapia , Aterectomía , Oclusión de Injerto Vascular/terapia , Arteria Ilíaca , Stents , Arteriopatías Oclusivas/diagnóstico por imagen , Estudios de Evaluación como Asunto , Estudios de Factibilidad , Femenino , Estudios de Seguimiento , Oclusión de Injerto Vascular/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Radiografía , Recurrencia , Factores de Tiempo , Resultado del Tratamiento , Grado de Desobstrucción Vascular
9.
Radiology ; 194(3): 739-44, 1995 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-7862972

RESUMEN

PURPOSE: To evaluate Strecker stent implantation in iliac arteries. MATERIALS AND METHODS: Sixty-four iliac arteries with Strecker stents were prospectively studied. Stents were placed for dissection (n = 31), total occlusion (n = 28), unsatisfactory results (n = 3) or restenosis (n = 1) after percutaneous transluminal angioplasty, and a calcified atherosclerotic lesion that bulged into the lumen (n = 1). RESULTS: Stent placement was successful in 63 arteries (98%). The overall complication rate was 12% (n = 8). During follow-up, three patients died. The stent was compromised in 18 cases because of hyperplasia (n = 10) or occlusion (n = 8). The primary patency rate was 84% at 1 year and 69% at 2 years; the secondary patency rate was 90% at 1 year and 81% at 2 years. Initial dissection (P = .046), a length of 60 mm or less for the stent region (P = .007), and total covering of the abnormal segment with the stent (P = .03) were significant predictive factors for good, long-term results. CONCLUSION: Use of the Strecker endoprosthesis appears useful but not ideal. Determination of predictive factors for long-term success may help identify indications for its use.


Asunto(s)
Disección Aórtica/terapia , Arteriopatías Oclusivas/terapia , Aneurisma Ilíaco/terapia , Arteria Ilíaca , Stents , Disección Aórtica/epidemiología , Angiografía de Substracción Digital , Arteriopatías Oclusivas/epidemiología , Diseño de Equipo , Femenino , Estudios de Seguimiento , Humanos , Aneurisma Ilíaco/epidemiología , Tablas de Vida , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Factores de Tiempo , Resultado del Tratamiento , Ultrasonografía Doppler Dúplex , Grado de Desobstrucción Vascular
10.
AJR Am J Roentgenol ; 166(5): 1173-9, 1996 May.
Artículo en Inglés | MEDLINE | ID: mdl-8615265

RESUMEN

OBJECTIVE: The purpose of our study was to report long-term (more than 2 years of follow-up) angiographic patency after self-expandable stent implantation in the iliac artery and to identify patient- or procedure-related prognostic factors of angiographic patency. SUBJECTS AND METHODS: Ninety-five consecutive patients (101 arteries) underwent Wallstent implantation to treat claudication (n=95 limbs), rest pain (n=2), and nonhealing ulcer (n=3). Another patient was asymptomatic but was treated for acute occlusion of the iliac artery after coronary angioplasty. After implantation of self-expandable stents, we followed up by examining clinical and angiographic records at 6 months, 1 year, and annually thereafter. The Kaplan-Meier survival curve was used to determine primary and secondary patency rates. Primary patency was that achieved after the initial procedure only. Secondary patency was defined as that achieved after one or more successful additional percutaneous procedures within the stent or beyond the stent. Multivariate analysis using the Cox proportional hazard model was performed to identify predictive factors of angiographic failure, defined as restenosis of 50% or greater or occlusion. RESULTS: Four-year patency rates of 61% (primary) and 86% (secondary) were found (mean follow-up, 29 months). The following five factors were associated with long-term angiographic failure: occlusion of the superficial femoral artery (relative hazard = 5.21), absence of hypertension (relative hazard = 4.85), a stent diameter of less than 8 mm (relative hazard = 4.45), two or more stents implanted (relative hazard = 3.56), and current tobacco consumption (relative hazard = 2.46). CONCLUSION: Improved patency rates may be obtained by selecting patients for Wallstent implantation in the iliac artery based on five factors shown to be prognostically important.


Asunto(s)
Arteriopatías Oclusivas/terapia , Arteria Ilíaca , Stents , Adulto , Angioplastia de Balón , Arteriopatías Oclusivas/diagnóstico por imagen , Femenino , Estudios de Seguimiento , Humanos , Arteria Ilíaca/diagnóstico por imagen , Tablas de Vida , Masculino , Persona de Mediana Edad , Pronóstico , Modelos de Riesgos Proporcionales , Radiografía , Stents/estadística & datos numéricos , Factores de Tiempo , Resultado del Tratamiento , Grado de Desobstrucción Vascular
11.
Radiology ; 180(3): 771-8, 1991 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-1831274

RESUMEN

The authors conducted a prospective study of 49 consecutive patients with 53 lesions in 52 iliac arteries. All were treated between October 1987 and April 1990 with percutaneous transluminal angioplasty (PTA) and insertion of either a self-expandable or balloon-expandable stent. Lesions included total occlusion (28%), dissection (42%), post-PTA restenosis (21%), and unsatisfactory PTA (9%). Complications included one aortic protrusion, one acute thrombosis of the stent (resolved with urokinase), and three distal embolizations (5.7%) (resolved with urokinase and aspiration). During 15 months of follow-up, two patients died (one after occlusion). Three other occlusions occurred; one of these was resolved with local thrombolysis. Hyperplasia occurred in seven cases (13.5%), and stenosis occurred at the end of the stent because of incomplete covering of the lesion in three (5.8%); a complementary procedure was performed in six of these cases. Primary patency was 85.3% at 12 months and 80.9% at 18 months; secondary patency rate was 96.1% at 12 and at 18 months. At the end of the study, excluding data for the two patients who died, 27 limbs (54%) were asymptomatic and improvement was achieved in 19 (38%); the clinical success rate was 92%. No amputations were required.


Asunto(s)
Arteria Ilíaca/diagnóstico por imagen , Stents , Adulto , Anciano , Angioplastia de Balón , Arteriopatías Oclusivas/diagnóstico por imagen , Arteriopatías Oclusivas/terapia , Femenino , Estudios de Seguimiento , Humanos , Hiperplasia/diagnóstico por imagen , Hiperplasia/etiología , Arteria Ilíaca/patología , Tablas de Vida , Masculino , Persona de Mediana Edad , Radiografía , Recurrencia , Trombosis/etiología , Grado de Desobstrucción Vascular
12.
J Vasc Interv Radiol ; 5(6): 849-58, 1994.
Artículo en Inglés | MEDLINE | ID: mdl-7873864

RESUMEN

PURPOSE: The authors report their experience with implantation of self-expandable stents into renal arteries. PATIENTS AND METHODS: Twenty-five Wallstent endoprostheses were deployed into 18 renal arteries in 18 patients. Atheroma was the cause of the initial renal artery lesion in 15 patients (four ostial, 10 postostial, and one long occlusion). In these 15 patients, indications for stent placement were 12 immediate failures of percutaneous transluminal renal angioplasty (PTRA), two immediate PTRA complications (dissections), and one recurrent stenosis. The other renal artery lesions were three dissections (two spontaneous and one after catheterization). RESULTS: The procedure was technically successful in all patients, with residual stenosis less than 20%. However, five stents were slightly misplaced and a second stent was implanted to fully cover the lesion. Three complications occurred: one acute thrombosis 15 days after stent implantation that was successfully treated with local fibrinolysis, one asymptomatic occlusion due to early thrombosis or to delayed restenosis, and one segmental renal infarction related to extensive dissection after PTRA and not to stent placement. Following stent implantation, systolic blood pressure (P = .006) and diastolic blood pressure (P = .002) measured at 6 months decreased significantly. Angiographic follow-up was obtained in 16 patients (with intravenous technique in nine and intraarterial digital subtraction angiography in seven) at a mean of 11 months after stent placement, and ultrasonographic follow-up was obtained in the two others after 8 and 25 months, respectively. A normal patent renal artery was demonstrated in 16 patients (89%); there was one restenosis with a 75% reduction in diameter of the renal artery and the asymptomatic occlusion above mentioned. CONCLUSION: Self-expandable stent implantation is a promising technique in PTRA failures. Wallstent placement is technically feasible. Immediate results were satisfactory and the midterm restenosis rate was low in this series of patients.


Asunto(s)
Arteria Renal , Stents , Adulto , Anciano , Angioplastia de Balón , Femenino , Humanos , Masculino , Persona de Mediana Edad , Radiografía Intervencional , Arteria Renal/diagnóstico por imagen , Obstrucción de la Arteria Renal/diagnóstico por imagen , Obstrucción de la Arteria Renal/terapia
13.
J Vasc Interv Radiol ; 9(1 Pt 1): 65-73, 1998.
Artículo en Inglés | MEDLINE | ID: mdl-9468397

RESUMEN

PURPOSE: To report the immediate results and the clinical and angiographic outcome of percutaneous angioplasty in patients with ostial renal artery stenosis. MATERIAL AND METHODS: Retrospective review of 52 percutaneous transluminal renal angioplasty (PTRA) procedures for strictly defined ostial atherosclerotic renal artery stenosis in 50 consecutive patients, selected among 670 PTRAs performed between 1983 and 1993. RESULTS: Immediate angiographic success was achieved in 30 arteries (58%) and improvement was achieved in 15 arteries (29%). The procedure was a failure in seven lesions (13%). PTRA was followed by a stent implantation in three lesions (6%). Two patients (4%) died within the first month after PTRA and a major complication occurred in seven other patients (13%). At a mean follow-up of 20.6 months, both systolic and diastolic blood pressure decreased significantly (P = .0006 and P = .0057 respectively). Renal function did not change significantly (P = .73). One patient was lost during follow-up. At angiographic control (mean, 11 months), restenosis occurred in 27% of the cases. There was no recurrence of pulmonary edema at a mean follow-up of 32 months in 50% of the 12 patients who experienced one episode or more before PTRA. CONCLUSIONS: True ostial renal artery stenosis is rare and often reflects severe and multifocal atheromatous disease. In these patients, PTRA might be considered an acceptable and relatively safe treatment that improves blood pressure and stabilizes renal function.


Asunto(s)
Angiografía , Angioplastia Coronaria con Balón , Obstrucción de la Arteria Renal/terapia , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/métodos , Angioplastia Coronaria con Balón/mortalidad , Femenino , Estudios de Seguimiento , Humanos , Masculino , Complicaciones Posoperatorias/diagnóstico por imagen , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/cirugía , Recurrencia , Obstrucción de la Arteria Renal/diagnóstico por imagen , Estudios Retrospectivos , Stents , Tasa de Supervivencia , Resultado del Tratamiento
14.
Cardiovasc Intervent Radiol ; 16(4): 203-8, 1993.
Artículo en Inglés | MEDLINE | ID: mdl-8402780

RESUMEN

From March 1990 to May 1991, arterial stents were placed in seven patients because of a tight stenosis (five patients) or a total chronic occlusion (two patients) located in the infrarenal aorta. In one case, the aortic occlusion extended to both common iliac arteries. After balloon dilatation, aortic stents were successfully positioned in all cases. Bilateral common iliac recanalization and stent placement were performed in one case. No complications occurred in any of the patients. No complications occurred in any of the patients. Follow-up data were derived from clinical assessments and angiographic results. After a 15.1-month mean follow-up period (range 12-24 months), the seven aortic stents remained patent. Three iliac artery procedures were performed in two of the patients as well. Claudication recurred in three of the seven patients which was related to a common iliac occlusion (one case) or distal progression of atherosclerosis (two cases). Aortic stents seem to be suitable for treating failed angioplasty of aortic lesions but the procedure remains technically difficult when there is associated severe atherosclerosis of the proximal common iliac arteries. Nevertheless, considering the morbidity rate (0%) and the patency rate in this series, this technique could become an alternative to surgical treatment for infrarenal aortic occlusive lesions.


Asunto(s)
Enfermedades de la Aorta/terapia , Arteriopatías Oclusivas/terapia , Stents , Angioplastia de Balón , Aorta Abdominal/diagnóstico por imagen , Enfermedades de la Aorta/diagnóstico por imagen , Enfermedades de la Aorta/epidemiología , Aortografía , Arteriopatías Oclusivas/diagnóstico por imagen , Arteriopatías Oclusivas/epidemiología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Factores de Riesgo , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA