Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Opt Express ; 19(21): 20316-21, 2011 Oct 10.
Artículo en Inglés | MEDLINE | ID: mdl-21997042

RESUMEN

Pulse-picking from a 100-mW cw mode-locked seeder, a hybrid master-oscillator power-amplifier (MOPA) system, based on Nd:YVO4 and Nd:YAG amplifier modules, has been developed, delivering single-pulses of 8.6 ps at 455-MHz repetition-rate, bunched into ~1-µs trains of 50 mJ ("macro-pulses"). The output beam is linearly polarized and nearly diffraction limited up to the maximum macro-pulse repetition-rate of 50 Hz. The single-pulse peak power and the macro-pulse duration and energy are quite suitable for high-energy nonlinear optical applications such as low-threshold synchronously-pumped parametric converters in the mid infrared. The impact on the overall efficiency of saturation distortion of the macro-pulse envelope as well as of amplified spontaneous emission (ASE) is considered. The managing of the envelope distortion compensation and of the ASE suppression by means of fast saturable absorbers is reported.

2.
Opt Lett ; 36(16): 3236-8, 2011 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-21847219

RESUMEN

We report a compact, efficient, high-energy, and high-repetition-rate mid-IR picosecond optical parametric oscillator (OPO) based on the new nonlinear material CdSiP(2) (CSP). The OPO is synchronously pumped by a master oscillator power amplifier system at 1064.1 nm, providing 1 µs long macropulses constituting 8.6 ps micropulses at 450 MHz, and it can be tuned over 486 nm across 6091-6577 nm, covering the technologically important wavelength range for surgical applications. Using a compact (∼30 cm) cavity and improved, high-quality nonlinear crystal, idler macropulse energy as high as 1.5 mJ has been obtained at 6275 nm at a photon conversion efficiency of 29.5%, with >1.2 mJ over more than 68% of the tuning range, for an input macropulse energy of 30 mJ. Both the signal and idler beams are recorded to have good beam quality with a Gaussian spatial profile, and the extracted signal pulses are measured to have durations of 10.6 ps. Further, from the experimentally measured transmission data at 1064 nm, we have estimated the two-photon absorption coefficient of CSP to be ß=2.4 cm/GW, with a corresponding energy bandgap, E(g)=2.08 eV.


Asunto(s)
Compuestos de Cadmio/química , Fenómenos Ópticos , Compuestos de Fósforo/química , Compuestos de Silicona/química , Rayos Infrarrojos
3.
Behav Neurol ; 17(2): 89-95, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-16873919

RESUMEN

Frontal variant-Frontotemporal dementia (fvFTD) and Alzheimer's disease (AD) patients matched for severity of dementia at the Clinical Dementia Rating (CDR) received neuropsychological testing in order to explore if the dysexecutive disorder might characterise fvFTD at early stage, when AD is dominated by the episodic memory defect. We also determined if the behavioural syndrome was more severe in fvFTD than AD, and if specific patterns of behavioural symptoms could differentiate the two types of dementia, using the Neuropsychiatry Inventory (NPI). AD patients performed worse than fvFTD not only in memory but also in executive tasks. Apathy and eating disorders proved to be more severe or frequent in fvFTD even if the two groups did not differ in the total NPI score. CDR score significantly correlated with the NPI score in fvFTD and with the MMSE in AD. Our data confirm that the memory disorders may differentiate the two types of dementia; however, the dysexecutive syndrome is as severe, and even more severe in AD. The severity of the behavioural syndrome is comparable in the two groups but the nature of the behavioural disorders may vary to some extent. We conclude that AD dementia at early stage is a behavioural-cognitive syndrome, while in fvFTD the behavioural disorders appear when the cognitive deficit is still relatively mild.


Asunto(s)
Enfermedad de Alzheimer/epidemiología , Enfermedad de Alzheimer/fisiopatología , Trastornos del Conocimiento/epidemiología , Lóbulo Frontal/fisiopatología , Trastornos Mentales/epidemiología , Lóbulo Temporal/fisiopatología , Anciano , Enfermedad de Alzheimer/diagnóstico , Trastornos del Conocimiento/diagnóstico , Femenino , Lóbulo Frontal/diagnóstico por imagen , Lóbulo Frontal/patología , Humanos , Imagen por Resonancia Magnética , Masculino , Trastornos Mentales/diagnóstico , Pruebas Neuropsicológicas , Índice de Severidad de la Enfermedad , Lóbulo Temporal/diagnóstico por imagen , Lóbulo Temporal/patología , Tomografía Computarizada por Rayos X
4.
Bone Marrow Transplant ; 22 Suppl 5: S41-5, 1998 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-9989889

RESUMEN

Peripheral blood stem cells (PBSCs) collected following stimulation with cytokines are commonly used for autologous haematopoietic transplants. Currently, PBSCs are being used for syngeneic or allogeneic transplants from matched or haploidentical donors. However, many issues are still unanswered regarding the early or late side-effects cytokines have on recipients and on healthy donors. The aims of this paper were to evaluate the experience acquired worldwide in this field, to define the acceptability of stem cell donation by G-CSF-stimulated apheresis from unrelated donors after the failure of a first donation, and to assess side-effects of G-CSF on unrelated donors. The use of PBSCs has increased tremendously over the last few years and in the near future PBSCs will probably become the most relevant source of stem cells. Studies conducted so far have definitely concluded that G-CSF is safe and well tolerated. Results observed in transplants utilizing marrow stem cells compared with results obtained in transplants utilizing PBSCs have shown that patients undergoing this latter procedure recover earlier, require a lower number of transfusions and spend fewer days in hospital with a consequent decrease in costs. We concluded that a second transplant by G-CSF-stimulated apheresis from an unrelated donor is definitely acceptable and we designed a prospective study to better define all controversial aspects. Donors will be given 10 microg/kg/day of G-CSF subcutaneously for 5 days. One or two PBSC collection procedures will be performed: the first on day 5 and the second, if necessary, on day 6. Donors will be surveyed and blood counts monitored in a standardized manner during the process.


Asunto(s)
Donantes de Sangre , Factor Estimulante de Colonias de Granulocitos/uso terapéutico , Células Madre Hematopoyéticas/citología , Leucaféresis/métodos , Humanos , Leucaféresis/normas , Guías de Práctica Clínica como Asunto , Trasplante Homólogo
5.
Tumori ; 79(6): 418-21, 1993 Dec 31.
Artículo en Inglés | MEDLINE | ID: mdl-8171743

RESUMEN

AIMS: This study was designed in an attempt to improve the sensitivity of cytologic examination of fineneedle aspiration biopsies. METHODS AND RESULTS: A prospective study was carried out on 79 patients with breast lesions less than 1 cm in diameter and clinically impalpable who were referred to the Radiodiagnostics Section of the Ca' Granda Hospital of Milan in 1990 and 1991 for mammographic and ultrasound verification. The examination was carried out using a high frequency (10 MHz) ultrasound probe to which an aspiration needle had been soldered. This made it possible to quickly and accurately reach the target nodule and thus gave a high sensitivity of the examination (93%). However, attachment of the needle to the probe prevented sampling from other points of the nodule and was responsible for the slight increase in number of inadequate samplesfi which in turn worsened the specificity of the test (86%). To check the gold standard of the examination, all the patients with positive or doubtful aspirations underwent surgical biopsy, whereas strict radiologic controls were performed in the negative cases. CONCLUSIONS: Ultrasound-guided fineneedle aspiration may have advantages over needle aspiration performed with the stereotactic radiologic technique. The needle can be monitored even if the patient moves; even deep, peripheral nodules as well as those near a prosthesis can be reached; repeated samples can be taken, and costs are limited.


Asunto(s)
Biopsia con Aguja/métodos , Enfermedades de la Mama/diagnóstico por imagen , Enfermedades de la Mama/patología , Neoplasias de la Mama/diagnóstico por imagen , Femenino , Humanos , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Sensibilidad y Especificidad , Ultrasonografía
6.
Chir Organi Mov ; 82(1): 53-9, 1997.
Artículo en Inglés, Italiano | MEDLINE | ID: mdl-9269114

RESUMEN

The study analyzes the results obtained when Bankart-Delitala surgery was used to treat recurrent anterior dislocation of the shoulder. A group of 30 patients were submitted to clinical and functional follow-up based on the Rowe system; 15 of the patients also underwent isokinetic testing. The data obtained were interpreted based on the Rowe system, but also analytically and statistically. The authors conclude that Bankart-Delitala surgery constitutes an effective surgical option in the treatment of recurrent anterior dislocation of the shoulder.


Asunto(s)
Luxación del Hombro/cirugía , Estudios de Evaluación como Asunto , Femenino , Estudios de Seguimiento , Humanos , Masculino , Complicaciones Posoperatorias , Recurrencia , Factores de Tiempo
7.
Rev Sci Instrum ; 82(11): 115107, 2011 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-22129013

RESUMEN

We describe recent improvements in the development of the high power laser system used in the motion induced radiation (MIR) experiment to amplify electromagnetic fields inside a microwave cavity. The improvements made on the oscillator stabilization, the pulse train shaping device, and the spatial beam uniformity are reported.

11.
Appl Opt ; 18(23): 3975-7, 1979 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-20216737

RESUMEN

A mode-locked Nd:YAG oscillator is described that operates at 1.052 microm. It is shown that a birefringent filter efficiently discriminates and selects each one of the fundamental Nd:YAG transitions.

12.
Opt Lett ; 17(6): 414-6, 1992 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-19784345

RESUMEN

Time-resolved M(2) numerical computation and experimental measurements of nanosecond pulses from a Q-switched variable-reflectivity-mirror Nd:YAG laser are presented for the first time to our knowledge. The beam quality parameter is seen to vary approximately from 1 at the beginning to 2 at the end of a high-energy pulse, with a value of 1.35 at the peak of the pulse, which also corresponds to the M(2) obtained from the time-averaged detection of the pulse profile.

13.
Opt Lett ; 18(9): 717-9, 1993 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-19802250

RESUMEN

We present a novel interpretation of Kerr lens mode locking based on the Z-scan operating principle and derive a few practical criteria for application to mode-locked solid-state laser systems.

14.
Boll Soc Ital Biol Sper ; 65(10): 923-9, 1989 Oct.
Artículo en Italiano | MEDLINE | ID: mdl-2624709

RESUMEN

We reported the main rheological and coagulative features in seven patients affected with monoclonal gammapathy: four of them presented IgA class paraprotein, two IgM class paraprotein and one IgG class paraprotein. All presented increased plasma and serum viscosity. The four patients affected with IgA monoclonal paraproteinaemia underwent one plasma volume plasmapheresis. This procedure has been demonstrated to be useful and effective in reducing both plasma and serum viscosity.


Asunto(s)
Coagulación Sanguínea/fisiología , Viscosidad Sanguínea , Inmunoglobulina A , Inmunoglobulina G , Inmunoglobulina M , Paraproteinemias/sangre , Plasmacitoma/sangre , Adulto , Humanos , Persona de Mediana Edad
15.
Opt Lett ; 22(18): 1415-7, 1997 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-18188255

RESUMEN

A quasi-cw diode-pumped Nd:YAG laser, mode locked by a nonlinear mirror and stabilized by an acousto-optic modulator, has been developed that generates 31-ps, 23-microJ pulses. Employing this source with a periodically poled lithium niobate crystal in a traveling-wave geometry, we obtained extracavity frequency conversion with pump depletion of as much as 62% in the near infrared (1.46- 1.56 microm) with a pulse spectral width of 1.5nm and a beam quality M(2)=1.7.

16.
Opt Lett ; 22(21): 1645-7, 1997 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-18188324

RESUMEN

A diode-pumped Nd(3+):YVO(4) laser passively mode locked by a nonlinear mirror based on second-harmonic generation has been developed. Pumping with a fiber-coupled 10-W diode array, we generated nearly diffraction limited, linearly polarized 11-ps pulses at 1064nm, with average power of 2.7 W at a 150-MHz repetition rate. Pulses as short as 7.9 ps were measured with reduced output power (1.35 W) by optimal focusing in the nonlinear crystal.

17.
Opt Lett ; 17(24): 1764-6, 1992 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-19798309

RESUMEN

A novel method for measuring the beam quality of short, powerful laser pulses is presented. The method is based on the Z-scan technique used to investigate the nonlinear susceptibilities of optical materials. It is shown that both two-photon absorption and nonlinear refraction of a nonlinear sample can be used to obtain information about the spatial quality of the pulses.

18.
Appl Opt ; 36(3): 597-601, 1997 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-18250713

RESUMEN

We report on the experimental results of a diode-pumped, intracavity-doubled cw Nd:YAG laser, pumped by a 10-W fiber-coupled semiconductor laser at 808 nm and emitting as much as 600 mW in a stable single longitudinal mode and TEM(00) spatial mode. We discuss the main issues of the resonator design and the optimization of the intracavity second harmonic conversion by interpreting our results using simple models. Improvements for the current project are also discussed.

19.
Opt Lett ; 10(8): 396-8, 1985 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-19724460

RESUMEN

We have measured the nonlinear refractive index, n(2), of CS(2) at 10.6 microm by observing the onset of whole-beam selffocusing. We find that n(2) is (2.2 +/- 0.7) x 10(-10) esu, which is over an order of magnitude larger than n(2) in the visible.

20.
Boll Soc Ital Biol Sper ; 66(4): 335-42, 1990 Apr.
Artículo en Italiano | MEDLINE | ID: mdl-2390223

RESUMEN

It has been speculated that changes in intrinsic blood flow properties may contribute to the evolution of vascular complications in diabetes mellitus. To verify this hypothesis we measured hematocrit, fibrinogen, plasma and blood viscosity in 30 diabetic patients and in 25 healthy volunteers. Diabetics showed blood and plasma viscosity and fibrinogenemia higher than healthy subjects, although only plasma viscosity and fibrinogenemia were statistically significant (p less than 0.001). Moreover the diabetic patients with the highest HbAlc values had a significant increase in plasma viscosity compared with the patients with lower HbAlc values (p less than 0.001), despite a similar fibrinogenemia. This study confirms the presence of hemorheological changes in diabetes mellitus and shows a correlation between plasma viscosity and metabolic control.


Asunto(s)
Viscosidad Sanguínea , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 2/sangre , Angiopatías Diabéticas/sangre , Retinopatía Diabética/sangre , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA