Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Sep Sci ; 40(15): 3086-3093, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28581679

RESUMEN

An extremely sensitive and simple gas chromatography with mass spectrometry method was developed and completely validated for the analysis of five process-related impurities, viz., 4-hydroxy-l-phenylglycine, 4-hydroxyphenylacetonitrile, 4-hydroxyphenylacetic acid, methyl-4-hydroxyphenylacetate, and 2-[4-{(2RS)-2-hydroxy-3-[(1-methylethyl)amino]propoxy}phenyl]acetonitrile, in atenolol. The separation of impurities was accomplished on a BPX-5 column with dimensions of 50 m × 0.25 mm i.d. and 0.25 µm film thickness. The method validation was performed following International Conference on Harmonisation guidelines in which the method was capable to quantitate 4-hydroxy-l-phenylglycine, 4-hydroxyphenylacetonitrile, and 4-hydroxyphenylacetic acid at 0.3 ppm, and methyl-4-hydroxyphenylacetate and 2-[4-{(2RS)-2-hydroxy-3-[(1-methylethyl)amino]propoxy}phenyl]acetonitrile at 0.35 ppm with respect to 10 mg/mL of atenolol. The method was linear over the concentration range of 0.3-10 ppm for 4-hydroxy-l-phenylglycine, 4-hydroxyphenylacetonitrile, and 4-hydroxyphenylacetic acid, and 0.35-10 ppm for methyl-4-hydroxyphenylacetate and 2-[4-{(2RS)-2-hydroxy-3-[(1-methylethyl)amino]propoxy}phenyl]acetonitrile. The correlation coefficient in each case was found ≥0.998. The repeatability and recovery values were acceptable, and found between 89.38% and 105.60% for all five impurities under optimized operating conditions. The method developed here is simple, selective, and sensitive with apparently better resolution than the reported methods. Hence, the method is a straightforward and good quality control tool for the quantitation of selected impurities at trace concentrations in atenolol.


Asunto(s)
Atenolol/análisis , Contaminación de Medicamentos , Cromatografía de Gases y Espectrometría de Masas , Control de Calidad
2.
J Sep Sci ; 38(15): 2580-7, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25989063

RESUMEN

A sensitive ultra high performance liquid chromatography with tandem mass spectrometry method was developed for the simultaneous determination of darunavir, ritonavir and tenofovir in human plasma. Sample preparation involved a simple liquid-liquid extraction using 200 µL of human plasma extracted with methyl tert-butyl ether for three analytes and internal standard. The separation was accomplished on an Acquity UPLC BEH C18 (50 mm x 2.1 mm, 1.7 µm) analytical column using gradient elution of acetonitrile/methanol (80:20, v/v) and 5.0 mM ammonium acetate containing 0.01% formic acid at a flow rate of 0.4 mL/min. The linearity of the method ranged between 20.0 and 12 000 ng/mL for darunavir, 2.0 and 2280 ng/mL for ritonavir, and 14.0 and 1600 ng/mL for tenofovir using 200 µL of plasma. The method was completely validated for its selectivity, sensitivity, linearity, precision and accuracy, recovery, matrix effect, stability, and dilution integrity. The extraction recoveries were consistent and ranged between 79.91 and 90.04% for all three analytes and internal standard. The method exhibited good intra-day and inter-day precision between 1.78 and 6.27%. Finally the method was successfully applied for human pharmacokinetic study in eight healthy male volunteers after the oral administration of 600 mg darunavir along with 100 mg ritonavir and 100 mg tenofovir as boosters.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Darunavir/sangre , Inhibidores de la Proteasa del VIH/sangre , Ritonavir/sangre , Espectrometría de Masas en Tándem/métodos , Tenofovir/sangre , Darunavir/farmacocinética , Inhibidores de la Proteasa del VIH/farmacocinética , Humanos , Ritonavir/farmacocinética , Tenofovir/farmacocinética
3.
J Sep Sci ; 38(5): 764-79, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25556762

RESUMEN

Potential genotoxic impurities in pharmaceuticals at trace levels are of increasing concern to both pharmaceutical industries and regulatory agencies due to their possibility for human carcinogenesis. Molecular functional groups that render starting materials and synthetic intermediates as reactive building blocks for small molecules may also be responsible for their genotoxicity. Determination of these genotoxic impurities at trace levels requires highly sensitive and selective analytical methodologies, which poses tremendous challenges on analytical communities in pharmaceutical research and development. Experimental guidance for the analytical determination of some important classes of genotoxic impurities is still unavailable in the literature. Therefore, the present review explores the structural alerts of commonly encountered potential genotoxic impurities, draft guidance of various regulatory authorities in order to control the level of impurities in drug substances and to assess their toxicity. This review also describes the analytical considerations for the determination of potential genotoxic impurities at trace levels and finally few case studies are also discussed for the determination of some important classes of potential genotoxic impurities. It is the authors' intention to provide a complete strategy that helps analytical scientists for the analysis of such potential genotoxic impurities in pharmaceuticals.


Asunto(s)
Contaminación de Medicamentos , Mutágenos/análisis , Preparaciones Farmacéuticas/análisis , Contaminación de Medicamentos/prevención & control , Industria Farmacéutica , Humanos
4.
Chemosphere ; 249: 126125, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32058133

RESUMEN

The application of chemical dispersants in marine oil spill remediation is comprehensively reported across the globe. But, the augmented toxicity and poor biodegradability of reported chemical dispersants have created necessity for their replacement with the bio-based green dispersants. Therefore, in the present study, we have synthesized five ionic liquids (ILs) namely 1-butyl-3-methylimidazolium lauroylsarcosinate, 1,1'-(1,4-butanediyl)bis(1-H-pyrrolidinium) dodecylbenzenesulfonate, tetrabutylammonium citrate, tetrabutylammonium polyphosphate and tetrabutylammonium ethoxylate oleyl ether glycolate, and formulated a water based ILs dispersant combining the synthesized ILs at specified compositions. The effectiveness of formulated ILs dispersant was found between 70.75% and 94.71% for the dispersion of various crude oils ranging from light to heavy. Further, the acute toxicity tests against zebra fish and grouper fish have revealed the practically non-toxic behaviour of formulated ILs dispersant with LC50 value greater than 100 ppm after 96 h. In addition, the formulated ILs dispersant has provided excellent biodegradability throughout the test period. Overall, the formulated new ILs dispersant is deemed to facilitate environmentally benign oil spill remediation and could effectively substitute the use of hazardous chemical dispersants in immediate future.


Asunto(s)
Restauración y Remediación Ambiental/métodos , Líquidos Iónicos/análisis , Contaminación por Petróleo/análisis , Contaminantes Químicos del Agua/análisis , Animales , Biodegradación Ambiental , Sustancias Peligrosas , Dosificación Letal Mediana , Petróleo , Tensoactivos/química , Pruebas de Toxicidad Aguda , Agua
5.
Chemosphere ; 229: 349-357, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31078892

RESUMEN

Ionic liquids (ILs) based surfactants have been emerged as attractive alternatives to the conventional surfactants owing to their tailor-made and eco-friendly properties. Therefore, present study described the synthesis of nine new fatty amino acids based IL surfactants utilizing lauroyl sarcosinate anion and pyrrolidinium, imidazolium, pyridinium, piperidinium, morpholinium and cholinium cations for the first time. The synthesized surface active lauroyl sarcosinate ionic liquids (SALSILs) were characterized by 1H NMR, 13C NMR and TGA. Next, the surface tension and critical micellar concentrations were determined and compared with the surface properties of ILs based surfactants. Further, the toxicity and biodegradability of the synthesized SALSIILs were evaluated to confirm their safe and efficient process applications. The studies revealed that three out of nine synthesized SALSILs containing pyridinium cation have showed strong activity towards the tested microbial growth. The remaining six SALSILs met the biocompatible measures demonstrating moderate to low activity depends on the tested microbes. The alicyclic SALSILs containing morpholinium and piperidinium cations have demonstrated 100% biodegradation after 28 days of the test period. Overall, it is believed that the synthesized SALSILs could effectively replace the conventional surfactants in a wide variety of applications.


Asunto(s)
Líquidos Iónicos/química , Sarcosina/análogos & derivados , Biodegradación Ambiental , Detergentes/química , Ecosistema , Ecotoxicología , Líquidos Iónicos/síntesis química , Sarcosina/química
6.
J Pharm Anal ; 3(6): 394-401, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29403845

RESUMEN

Combination of asenapine with valproic acid received regulatory approval for acute treatment of schizophrenia and maniac episodes of bipolar disorders. A simple LC-MS/MS method was developed and validated for simultaneous quantification of asenapine and valproic acid in human plasma. Internal standards were added to 300 µL of plasma sample prior to liquid-liquid extraction using methyl tertiary butyl ether (MTBE). Chromatographic separation was achieved on Phenomenex C18 column (50 mm×4.6 mm, 5 µm) in isocratic mode at 40 °C. The mobile phase used was 10 mM ammonium formate-acetonitrile (5:95, v/v) at a constant flow rate of 0.8 mL/min monitored on triple quadrupole mass spectrometer, operating in the multiple reaction monitoring (MRM) mode. The injection volume used for LC-MS/MS analysis was 15 µL and the run time was 2.5 min. These low run time and small injection volume suggest the high efficiency of the proposed method. The method was validated over the concentration range of 0.1-10.02 ng/mL and 10-20,000 ng/mL for asenapine and valproic acid respectively. The method recoveries of asenapine (81.33%), valproic acid (81.70%), gliclazide (78.45%) and benzoic acid (79.73) from spiked plasma samples were consistent and reproducible. The application of this method was demonstrated by a pharmacokinetic study in 8 healthy male volunteers with 5 mg asenapine and 250 mg valproic acid administration.

7.
Artículo en Inglés | MEDLINE | ID: mdl-23896293

RESUMEN

Zerovalent iron nanoparticles (ZVNI) were synthesized using a rapid, single step and completely green synthetic method from the leaf extracts of Eucalyptus globules and were characterized using the techniques Scanning Electron Microscopy (SEM), UV-Vis Spectroscopy, Fourier Transform-Infrared Spectroscopy (FT-IR), X-ray Diffraction (XRD) and Zeta potential measurement. The FT-IR analysis reveals that the polyphenolic compounds present in the leaf extract may be responsible for the reduction and stabilization of the ZVNI. These nanoparticles were utilized for the adsorption of hexavalent chromium (Cr (VI)) and the concentration of Cr (VI) was determined using UV-Vis spectrometer after treating with ZVNI. Response and surface contour plots were drawn with the help of Mini-tab software to explain the adsorption of Cr (VI). The adsorption efficiency of Cr (VI) reaches to the highest value (98.1%) when the reaction time was about 30 min. and the ZVNI dosage was 0.8 g/L. The effective parameters such as adsorbent (ZVNI) dosage, initial Cr (VI) concentration and the kinetics were also examined.


Asunto(s)
Cromo/aislamiento & purificación , Contaminantes Ambientales/aislamiento & purificación , Hierro/química , Nanopartículas/química , Adsorción , Eucalyptus/química , Tecnología Química Verde , Nanopartículas/ultraestructura , Espectrofotometría Ultravioleta
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA