Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Vasc Surg ; 75(4): 1268-1275.e1, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34655682

RESUMEN

BACKGROUND: Isolated iliac artery aneurysms (IAAs), accounting for 2% to 7% of all abdominal aneurysms, are often treated with the use of iliac branched endografts. Although outside the manufacturer's instructions for use, iliac branched devices can be used solely, without the adjunctive placement of an endovascular aneurysm repair device, for the treatment of an isolated IAA. In the present study, we have described the outcomes of the use of the Gore iliac branched endoprosthesis (IBE; W.L. Gore & Associates, Flagstaff, Ariz), without the support of an infrarenal endovascular aneurysm repair device, for the exclusion of an isolated IAA. The present study was an international multicenter retrospective cohort analysis. METHODS: All the patients who had undergone treatment with a solitary IBE for IAA exclusion from January 11, 2013 to December 31, 2018 were retrospectively reviewed. The primary outcome was technical success. The secondary outcomes included mortality, intraoperative and postoperative complications, and reintervention. RESULTS: A total of 18 European and American centers participated, with a total of 51 patients in whom 54 IAAs were excluded. The technical success rate was 94.1%, with an assisted technical success rate of 96.1%. No 30-day mortality occurred, with 98.1% patency of the internal and external iliac artery found at 24 months of follow-up. At 24 months of follow-up, 81.5% of the patients were free of complications and 90% were free of a secondary intervention. CONCLUSIONS: Treatment with a solitary IBE is a safe and, at midterm, an effective treatment strategy for selected patients with a solitary IAA.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Aneurisma Ilíaco , Aneurisma de la Aorta Abdominal/cirugía , Prótesis Vascular , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Humanos , Aneurisma Ilíaco/diagnóstico por imagen , Aneurisma Ilíaco/etiología , Aneurisma Ilíaco/cirugía , Arteria Ilíaca/diagnóstico por imagen , Arteria Ilíaca/cirugía , Diseño de Prótesis , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento , Grado de Desobstrucción Vascular
2.
Eur J Vasc Endovasc Surg ; 53(2): 290-298, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-28025005

RESUMEN

OBJECTIVE/BACKGROUND: Mechanochemical endovenous ablation (MOCA) has been developed as a tumescentless technique to ablate saphenous veins and to avoid heat induced complications and post-procedural pain. The mechanism of action of MOCA is poorly understood. The present experiments were conducted to determine the effect of MOCA on vein wall injury and sclerosis in an animal model. METHODS: A total of 36 lateral saphenous veins (LSVs) were treated in 18 goats according to the human protocol. Veins from nine goats were evaluated 45 min after the procedure, while in the remaining nine, the treated veins were evaluated 6 weeks later. All treated veins were divided equally over three treatment groups: (i) MOCA, (ii) mechanical ablation without the sclerosant, and (iii) liquid sclerotherapy alone. The histological effects of treatment on the vein wall were systematically evaluated. RESULTS: The average diameter of the LSV was 4.0 ± 0.5 mm. Technical success was achieved in all but one LSV (35/36; 97%), with a median procedure time of 14 min (range 9-22 min). In the acute group, histological examination showed that mechanical ablation (alone or MOCA) induced severe injury to the endothelium in 82% but no damage to other layers of the vein wall. Mechanical ablation led to vasoconstriction. After 6 weeks follow-up, four of six MOCA treated veins were occluded. The occluded segments consisted mainly of fibrotic lesions probably evolved from organised thrombus. No occlusions were observed after sclerotherapy or mechanical treatment alone. No major complications occurred during procedures or follow-up. CONCLUSION: MOCA is associated with an increased occlusion rate compared with its separated components of mechanical ablation or sclerotherapy. The occlusion consists of cellular fibrotic material likely to be evolved from organised thrombus with fibrotic alterations to the surrounding media and adventitia. This study underlines the hypothesis that the additive use of MOCA increases the effectiveness of sclerosants alone by inducing endothelial damage and probably vasoconstriction.


Asunto(s)
Técnicas de Ablación/instrumentación , Procedimientos Endovasculares/instrumentación , Vena Safena/cirugía , Soluciones Esclerosantes/administración & dosificación , Técnicas de Ablación/efectos adversos , Animales , Endotelio Vascular/patología , Procedimientos Endovasculares/efectos adversos , Femenino , Fibrosis , Cabras , Hiperplasia , Modelos Animales , Músculo Liso Vascular/patología , Vena Safena/patología , Vena Safena/fisiopatología , Soluciones Esclerosantes/efectos adversos , Escleroterapia/efectos adversos , Factores de Tiempo , Vasoconstricción
3.
J Anat ; 229(4): 582-90, 2016 10.
Artículo en Inglés | MEDLINE | ID: mdl-27329696

RESUMEN

Over the years, various vascular injection products have been developed to facilitate anatomical dissections. This study aimed to compare the most commonly used vascular injection products in fresh-frozen and formalin-embalmed cadaver specimens. An overview of the properties, advantages and limitations of each substance was given, and a comparison of vascular infusion procedures in both preservation methods was made. A literature search was performed in order to identify the most commonly used vascular injection products. Acrylic paint, latex, gelatin, silicone, Araldite F and Batson's No. 17 were selected for the study. One fresh-frozen and one embalmed cadaver forearm were infused with each injection product according to a uniform protocol. The curing time, skin- and subcutaneous tissue penetration, degree of filling of the arterial tree, extravasations, consistency of the injected vessels during dissection, and the costs of each injection fluid were noted. There was a large variation between the injection fluids in processing- and curing time, colour intensity, flexibility, fragility, elasticity, strength, toxicity and costs. All fluids were suitable for infusion. The penetration of injection fluid into the skin and subcutaneous tissue was significantly better in fresh-frozen specimens (P = 0.002 and P = 0.009, respectively), with significantly smaller branches casted (P = 0.004). Vascular infusion of fresh-frozen cadaver specimens results in a significantly better filled coloured arterial tree, enabling more detail to be achieved and smaller branches casted. The biomechanical properties of fresh-frozen soft tissues are less affected compared with formalin fixation. All the injection fluids studied are suitable for vascular infusion, but their different properties ensure that certain products and procedures are more suitable for specific study purposes.


Asunto(s)
Anatomía/métodos , Vasos Sanguíneos/anatomía & histología , Cadáver , Disección , Embalsamiento , Resinas Epoxi , Antebrazo , Gelatina , Humanos , Látex , Pintura , Plásticos , Siliconas
4.
Eur J Vasc Endovasc Surg ; 52(1): 99-104, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27179387

RESUMEN

OBJECTIVE: The use of self-expanding stent grafts for treatment of popliteal artery aneurysms (PAA) is a matter of debate, although several studies have shown similar results compared with open surgery. In recent years, a new generation stent graft, with heparin-bonding technology, became available. The aim of this study is to present the results of endovascular PAA repair with heparin-bonded stent grafts. METHODS: Data on all patients with PAA treated with a heparin-bonded polytetrafluoroethylene (ePTFE) stent graft between April 2009 and March 2014 were gathered in a database and retrospectively analyzed. Data were collected from four participating hospitals. Standard follow-up consisted of clinical assessment, and duplex ultrasound at 6 weeks, 6 months, 12 months, and annually thereafter. The primary endpoint of the study was primary patency. Secondary endpoints were primary-assisted and secondary patency and limb salvage rate. RESULTS: A total of 72 PAA was treated in 70 patients. Mean age was 71.2 ± 8.5 years and 93% were male (n = 65). The majority of PAA were asymptomatic (78%). Sixteen cases (22%) had a symptomatic PAA, of which seven (44%) presented with acute ischemia. Early postoperative complications occurred in two patients (3%). Median follow-up was 13 months (range 0-63 months). Primary patency rate at 1 year was 83% and after 3 years 69%; primary assisted patency rate was 87% at 1 year and 74% after 3 years. Secondary patency rate was 88% and 76% at 1 and 3 years, respectively. There were no amputations during follow-up. CONCLUSION: Endovascular treatment of PAA with heparin-bonded stent grafts is a safe treatment option with good early and mid-term patency rates comparable with open repair using the great saphenous vein.


Asunto(s)
Prótesis Vascular , Stents Liberadores de Fármacos , Arteria Poplítea/cirugía , Injerto Vascular/métodos , Anciano , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/métodos , Femenino , Heparina/administración & dosificación , Heparina/uso terapéutico , Humanos , Masculino , Resultado del Tratamiento , Injerto Vascular/instrumentación , Grado de Desobstrucción Vascular
5.
Eur J Vasc Endovasc Surg ; 51(1): 56-62, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26437914

RESUMEN

OBJECTIVE: Endovascular aortic sealing (EVAS) with the Nellix endosystem (Endologix, Irvine, CA, USA) is a new concept to treat infrarenal abdominal aortic aneurysms (AAAs). By sealing the aneurysm, potential endoleaks may be avoided. Early results of EVAS are good, but no data have been published regarding peri-procedural changes in aortoiliac anatomy. In this study, 27 consecutive patients who underwent elective EVAS repair of an AAA were reviewed. METHOD: Specific AAA (diameter, length from renal arteries to aortic bifurcation, supra- and infrarenal neck angulation, AAA volume, thrombus volume, and flow lumen volume), and iliac artery characteristics (length, angulation, location of most severe angulation with reference to the origin of the common iliac artery) were determined from pre- and post-procedural reconstructed computed tomography angiograms. RESULTS: No type I or II endoleaks were seen at 30 day follow up. Total AAA volume, suprarenal and infrarenal angulation, as well as aortic neck diameter did not change significantly post-EVAS. AAA flow lumen increased significantly (mean difference -4.4 mL, 95% CI 2.0 to -8.6 mL) and AAA thrombus volume decreased (mean difference 3.2 mL, 95% CI 2.0 to -1.1 mL). AAA length (125.7 mm vs. 123.1 mm), left common iliac artery length (57.6 mm vs. 55.3 mm), and right and left maximum iliac artery angulation (right 37.4° vs. 32.2°; left: 43.9° vs. 38.4°) were reduced significantly and the location of maximum angulation was further from the iliac artery origin post-EVAS, suggesting slight straightening of the aortoiliac anatomy. CONCLUSION: Most aortoiliac anatomic characteristics remained unchanged post-EVAS. Filling of the endobags to a pressure of 180 mmHg may lead to lost thrombus volume in some patients, probably because liquid is squeezed into lumbar or the inferior mesenteric artery. The absolute differences in pre- and post-EVAS aortoiliac lengths were small, so pre-operative sizing is accurate for determining stent length.


Asunto(s)
Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Arteria Ilíaca/cirugía , Stents , Anciano , Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/diagnóstico , Aortografía/métodos , Procedimientos Quirúrgicos Electivos , Femenino , Humanos , Arteria Ilíaca/diagnóstico por imagen , Masculino , Diseño de Prótesis , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
6.
Eur J Vasc Endovasc Surg ; 52(1): 64-74, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27162000

RESUMEN

OBJECTIVE/BACKGROUND: Aorto-bifemoral bypass remains the gold standard for treatment of aortoiliac occlusive disease (AIOD) in patients with advanced (TASC D) lesions, but has significant associated morbidity and mortality. Treatment with a unibody stent-graft positioned at the aortic bifurcation is a potential endovascular option for the treatment of AIOD. The current study examines the safety, efficacy, and early patency rates of the Endologix AFX unibody stent-graft for treatment of AIOD. METHODS: A multicenter retrospective review was conducted of patients treated exclusively for AIOD with the AFX device. Primary, assisted primary, and secondary patency rates were noted. Clinical improvement was assessed using Rutherford classification and ankle brachial index. Mean duration of follow-up was 22.2 ± 11.2 months. Ninety-one patients (56 males [62%]) were studied. RESULTS: Sixty-seven patients (74%) presented with lifestyle-limiting intermittent claudication and the remaining 24 (26%) had critical limb ischemia. Technical success was 100%. Complications included groin infection (n = 4 [4%]), groin hematoma (n = 4 [4%]), common iliac rupture (n = 4 [4%]), iliac dissection (n = 4 [4%]), and thromboembolic event (n = 3 [3%]; one femoral, one internal iliac artery, and one internal iliac with bilateral popliteal/tibial thromboemboli). Thirty-day mortality was 1% (1/91) resulting from a case of extensive pelvic thromboembolism. At 1 year, 73% of patients experienced improvement in Rutherford stage of -3 or greater compared with baseline. Nine patients (10%) required 16 secondary interventions. At all time points, primary patency rates were > 90%, assisted patency rates were > 98%, and secondary patency rates were 100%. CONCLUSION: This is the largest study to examine the use of the Endologix AFX unibody stent-graft for the treatment of AIOD. Use of the AFX stent-graft appears to be a safe and effective endovascular treatment for complex AIOD.


Asunto(s)
Enfermedades de la Aorta/cirugía , Prótesis Vascular , Arteria Ilíaca/cirugía , Stents , Injerto Vascular/métodos , Anciano , Índice Tobillo Braquial , Arteriopatías Oclusivas/cirugía , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/métodos , Extremidades/irrigación sanguínea , Femenino , Humanos , Claudicación Intermitente/etiología , Isquemia/etiología , Masculino , Estudios Retrospectivos , Resultado del Tratamiento , Injerto Vascular/efectos adversos , Injerto Vascular/instrumentación , Grado de Desobstrucción Vascular
7.
Eur J Vasc Endovasc Surg ; 50(5): 638-47, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26343310

RESUMEN

OBJECTIVE: In this study the first results are presented of a new endovascular technique using covered stents to reconstruct the aortic bifurcation in patients with aortoiliac occlusive disease. With the "Covered Endovascular Reconstruction of the Aortic Bifurcation" (CERAB) technique, the anatomy and physiology of the aortic bifurcation is mimicked. MATERIAL AND METHODS: Between 2009 and March 2014, 103 patients (51 male, 52 female) suffering from obstructive lesions at the level of the aortic bifurcation were treated with CERAB in two clinics. The median age was 61 years (range 36-85 years). Lesion morphology was evaluated by CT angiography. Six TASC-II B lesions, nine TASC-II C lesions, and 88 TASC-II D lesions were treated. Follow up was a median 12 months (range 0-49 months) and consisted of clinical examination, ankle brachial indices, and duplex ultrasound examination. RESULTS: Technical success was obtained in 98 procedures (95.1%). In five cases lesions could not be recanalized. Primary patency was 87.3% at 1 year and 82.3% at 2 years, while secondary patency was 95.0% at 1 year and 95.0% at 2 years. Mean ankle brachial indices improved significantly from 0.64 ± 0.21 before to 0.91 ± 014, after the procedure (p < .001). The overall 30 day complication rate was 23.3%, including 22 minor complications and two major complications (1.9%). There was no 30 day mortality. Median hospital stay was 2 days (range 1-16 days). CONCLUSIONS: The CERAB technique appears to be a safe and feasible alternative to open surgical reconstruction of the aortic bifurcation in complex occlusive disease. Comparative studies with the current gold standards are indicated.


Asunto(s)
Aorta Abdominal/cirugía , Arteriopatías Oclusivas/cirugía , Procedimientos Endovasculares/métodos , Arteria Ilíaca/cirugía , Stents , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
8.
Eur J Vasc Endovasc Surg ; 48(5): 545-50, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25218651

RESUMEN

BACKGROUND: Arterial insufficiency is rarely caused by isolated infrarenal aortic occlusive lesions. Endovascular treatment options include plain balloon angioplasty and bare metal stent placement. In this study the feasibility and efficacy of polytetrafluoroethylene (PTFE) covered balloon expandable stents were evaluated. MATERIAL AND METHODS: Consecutive patients from two centers were prospectively collected in a database and retrospectively analyzed. Results were evaluated by clinical examination, ankle-brachial indices (ABI), duplex ultrasound, and plain abdominal radiography. RESULTS: Thirty-six consecutive patients were treated between November 2008 and June 2013. Indication for treatment was Rutherford 3 (n = 29), 4 (n = 3), and 5 (n = 4). Technical success was always achieved and there were no distal embolizations or vessel wall ruptures. The median follow-up was 22 months (range 0-60). All patients improved clinically and the ABI increased significantly from 0.73 ± 0.18 to 1.01 ± 0.14 (p < .01). One patent covered stent was removed surgically because of infection. Primary patency rates were 100% at 1 and 2 years without stent fractures. CONCLUSION: The use of PTFE covered stents for the treatment of isolated infrarenal aortic occlusive disease is safe and very effective. Patency rates are excellent and complications including distal embolization and vessel wall rupture are extremely rare.


Asunto(s)
Aorta Abdominal/cirugía , Arteriopatías Oclusivas/cirugía , Riñón/irrigación sanguínea , Politetrafluoroetileno/uso terapéutico , Stents , Grado de Desobstrucción Vascular/fisiología , Implantación de Prótesis Vascular/métodos , Femenino , Humanos , Masculino , Politetrafluoroetileno/efectos adversos , Estudios Retrospectivos , Resultado del Tratamiento
9.
Cardiovasc Intervent Radiol ; 47(5): 533-542, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38565717

RESUMEN

PURPOSE: In arterial disease, the presence of two or more serial stenotic lesions is common. For mild lesions, it is difficult to predict whether their combined effect is hemodynamically significant. This study assessed the hemodynamic significance of idealized serial stenotic lesions by simulating their hemodynamic interaction in a computational flow model. MATERIALS AND METHODS: Flow was simulated with SimVascular software in 34 serial lesions, using moderate (15 mL/s) and high (30 mL/s) flow rates. Combinations of one concentric and two eccentric lesions, all 50% area reduction, were designed with variations in interstenotic distance and in relative direction of eccentricity. Fluid and fluid-structure simulations were performed to quantify the combined pressure gradient. RESULTS: At a moderate flow rate, the combined pressure gradient of two lesions ranged from 3.8 to 7.7 mmHg, which increased to a range of 12.5-24.3 mmHg for a high flow rate. Eccentricity caused an up to two-fold increase in pressure gradient relative to concentric lesions. At a high flow rate, the combined pressure gradient for serial eccentric lesions often exceeded the sum of the individual lesions. The relative direction of eccentricity altered the pressure gradient by 15-25%. The impact of flow pulsatility and wall deformability was minor. CONCLUSION: This flow simulation study revealed that lesion eccentricity is an adverse factor in the hemodynamic significance of isolated stenotic lesions and in serial stenotic lesions. Two 50% lesions that are individually non-significant can combine more often than thought to hemodynamic significance in hyperemic conditions.


Asunto(s)
Simulación por Computador , Hemodinámica , Humanos , Hemodinámica/fisiología , Modelos Cardiovasculares , Velocidad del Flujo Sanguíneo , Estenosis Coronaria/fisiopatología , Estenosis Coronaria/diagnóstico por imagen
10.
Vasc Endovascular Surg ; : 15385744241286585, 2024 Sep 21.
Artículo en Inglés | MEDLINE | ID: mdl-39305507

RESUMEN

INTRODUCTION: The outcomes of carotid surgery are commonly evaluated using parameters such as mortality and stroke. The importance of these parameters is based on doctors' and scientific perspectives. Presently, patient centered health care aims to value the evaluation from patients' perspective, mostly using Patient-Reported Outcomes (PROs). The true significance of outcomes of carotid surgery that matter most to the patients is largely unknown. The aim of this study is to identify and verify the patients' perspective on carotid surgery for patients with a symptomatic and significant carotid stenosis. METHODS AND OUTCOMES: An exploratory semi-structured focus group discussion will be used, as a quality research method. Three groups consisting of 8 patients (n = 24), who underwent the carotid endarterectomy because of a significant and symptomatic stenosis of the internal carotid artery, will be enrolled. If data saturation is not reached, the sample size will be expanded. An expert medical psychologist will lead the focus group discussions. The interviews will be recorded, transcribed 'verbatim' and analyzed after each session. Items valuable to patients regarding their surgery and recovery will be discussed. This protocol will be published prior to the start of the Focus Group Discussion. DISCUSSION: Patients' perspective on outcomes regarding their carotid surgery will be explored and tried to be identified. The results of the focus group discussions may fuel the ongoing global discussion on improving evidence based and patient reported outcome measures and will help the clinical physician to 'understand' their patients better. Focus group discussions may aid in the purpose of verification of PROs and PROMs.

11.
Eur J Vasc Endovasc Surg ; 45(3): 299-303, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23312507

RESUMEN

OBJECTIVE: This study evaluated the feasibility, safety and 1-year results of mechanochemical endovenous ablation (MOCA™) of small saphenous vein (SSV) insufficiency. DESIGN: Prospective cohort study. MATERIALS AND METHODS: Fifty consecutive patients were treated for primary SSV insufficiency with MOCA™ using the ClariVein(®) device and polidocanol. Initial technical success, complications, patient satisfaction and visual analogue scale (VAS) pain score were assessed. Anatomic and clinical success was assessed at 6 weeks and at 1 year. RESULTS: Initial technical success of MOCA™ was 100%. At the 6-week assessment, all treated veins were occluded. The 1-year follow-up duplex showed anatomic success in 94% (95% confidence interval, 0.87-1). Venous clinical severity score (VCSS) decreased significantly from 3.0 (interquartile range (IQR) 2-5) before treatment to 1.0 (IQR 1-3, P < 0.001) at 6 weeks and to 1.0 (IQR 1-2, P < 0.001) at 1 year. Median procedural VAS score for pain was 2 (IQR 2-4). No major complications were observed, especially no nerve injury. CONCLUSIONS: MOCA™ is a safe, feasible and efficacious technique for treatment of SSV insufficiency. One-year follow-up shows a 94% anatomic success rate and no major complications.


Asunto(s)
Técnicas de Ablación/instrumentación , Vena Safena/cirugía , Ultrasonografía Doppler Dúplex/instrumentación , Insuficiencia Venosa/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Cohortes , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Satisfacción del Paciente , Estudios Prospectivos , Vena Safena/diagnóstico por imagen , Resultado del Tratamiento , Insuficiencia Venosa/diagnóstico por imagen
12.
Vasc Endovascular Surg ; 57(7): 816-819, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37518891

RESUMEN

We describe a patient with a fistula between small bowel and a polyester patch of the common iliac artery. After emergency treatment with an endograft, the patch was replaced by a venous patch. Within 3-week a symptomatic pseudoaneurysm developed. It was decided to embolize the pseudoaneurysm using autologous subcutaneous fat, followed by a femoro-femoral crossover bypass using an allograft. Using this technique, the pseudoaneurysm was successfully excluded. This case shows that subcutaneous fat tissue can be used as an autologous embolic material, also in larger vessel pathology and in cases of ongoing infection, where regular embolization material cannot be used.


Asunto(s)
Aneurisma Falso , Implantación de Prótesis Vascular , Humanos , Arteria Ilíaca/cirugía , Aneurisma Falso/diagnóstico por imagen , Aneurisma Falso/etiología , Aneurisma Falso/terapia , Resultado del Tratamiento , Grasa Subcutánea/diagnóstico por imagen , Grasa Subcutánea/cirugía
13.
Eur J Vasc Endovasc Surg ; 44(4): 359-67, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22831869

RESUMEN

OBJECTIVE: Heparin is used worldwide by vascular surgeons as prophylaxis for arterial thrombo-embolic complications during open and endovascular arterial surgery. Possible harmful effect of heparin use is more perioperative blood loss, resulting in a higher morbidity and mortality. To evaluate the evidence for the use of heparin during aorto-iliac arterial surgery a review was performed. METHODS: A systematic review was performed of literature from MEDLINE, EMBASE and Cochrane databases, last search performed on March 8, 2012. RESULTS: For open surgery for abdominal aortic aneurysm (AAA), only 5 studies were eligible for review and for endovascular aneurysm repair (EVAR) only 1 study. Overall methodological quality of the included studies was poor. One randomised trial could be retrieved. Possible harmful effects of heparin were found of increasing operation time, more blood loss and more transfusion requirements when heparin was used for open AAA surgery in one study. No data were found comparing heparin to no intervention for EVAR. One study compared heparin to a direct thrombin antagonist during EVAR, showing no differences in clinical outcomes. CONCLUSION: Despite limitations this review showed no compelling evidence on the beneficiary effect of the prophylactic perioperative use of heparin during open surgery for (r)AAA. Authors will promote a randomised controlled multi-center trial on this topic for elective open surgical repair of AAA.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/métodos , Procedimientos Endovasculares/métodos , Fibrinolíticos/uso terapéutico , Complicaciones Intraoperatorias/prevención & control , Atención Perioperativa/métodos , Tromboembolia/prevención & control , Humanos
14.
Cardiovasc Eng Technol ; 13(2): 265-278, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34585343

RESUMEN

PURPOSE: The aim of this study was to investigate if non-invasive central pressure estimations are accurate in patients with an abdominal aortic aneurysm, before and after endovascular repair. Secondary evaluation was if measurement-accuracy was dependent on anatomical characteristics. METHODS: Procedural invasive and non-invasive pressure-measurements were performed simultaneously both before and after endovascular repair in 20 patients with an infrarenal abdominal aortic aneurysm. Invasive catheter measurements were performed in the abdominal aorta. A tonometric device was used to perform non-invasive pressure-wave-analysis at the radial artery. A generalized transfer-function was used to generate an ascending aortic waveform for both measurements, allowing for direct comparison. RESULTS: Pre-treatment the mean differences between methods were - 5.5 mmHg (p = .904), - 11.8 (p < .001), and - 7.2 mmHg (p = .124) for central systolic, diastolic, and mean pressure, respectively. The accuracy was dependent of aneurysm sac volume and intraluminal thrombus volume. Post-treatment limits of agreement were smaller for all pressure parameters compared to pre-treatment. The mean differences were 6.5 mmHg (p = .007), - 6.4 (p < .020), and 1.6 mmHg (p = .370) for central systolic, diastolic, and mean pressure, respectively. CONCLUSION: In untreated AAA's the accuracy of non-invasive central pressure estimation was acceptable (mean difference between 5 and 10 mmHg) when compared to invasive pressures, but dependent of AAA characteristics. After EVAR the accuracy of central pressure estimation improved (reduction of 75% of the mean difference between pre and post measurements) TRIAL REGISTRATION NUMBER: NCT03469388; 3-5-2018.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Aorta Abdominal , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Humanos , Resultado del Tratamiento
15.
Cardiovasc Intervent Radiol ; 45(6): 858-866, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35378613

RESUMEN

PURPOSE: The feasibility of using a compressed interwoven Supera stent as a flow diverting device for popliteal aneurysms was recently demonstrated in patients. It is unclear, however, what the optimal flow diverting strategy is, because of the fusiform shape of popliteal aneurysms and their exposure to triphasic flow. To assess this flow diverting strategy for popliteal aneurysms, flow profiles and thrombus formation likelihood were investigated in popliteal aneurysm models. MATERIALS AND METHODS: Six popliteal aneurysm models were created and integrated into a pulsatile flow set-up. These models covered a bent and a straight anatomy in three configurations: control, single-lined and dual-lined Supera stents. Two-dimensional flow velocities were visualized by laser particle image velocimetry. In addition, the efficacy of the stent configurations for promoting aneurysm thrombosis was assessed by simulations of residence time and platelet activation. RESULTS: On average for the two anatomies, the Supera stent led to a twofold reduction of velocities in the aneurysm for single-lined stents, and a fourfold reduction for dual-lined stents. Forward flow was optimally diverted, whereas backward flow was generally deflected into the aneurysm. The dual-lined configuration led to residence times of 15-20 s, compared to 5-15 s for the single stent configurations. Platelet activation potential was not increased by the flow diverting stents. CONCLUSION: A compressed Supera stent was successfully able to divert flow in a popliteal aneurysm phantom. A dual-lined configuration demonstrated superior hemodynamic characteristics compared to its single-lined counterpart.


Asunto(s)
Aneurisma , Arteria Poplítea , Aleaciones , Aneurisma/diagnóstico por imagen , Aneurisma/cirugía , Humanos , Arteria Poplítea/diagnóstico por imagen , Diseño de Prótesis , Stents , Resultado del Tratamiento , Grado de Desobstrucción Vascular
16.
Surg Endosc ; 25(1): 1-9, 2011 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-20552372

RESUMEN

BACKGROUND: Laparoscopic surgery has been incorporated into common surgical practice. The peritoneum is an organ with various biologic functions that may be affected in different ways by laparoscopic and open techniques. Clinically, these alterations may be important in issues such as peritoneal metastasis and adhesion formation. METHODS: A literature search using the Pubmed and Cochrane databases identified articles focusing on the key issues of laparoscopy, peritoneum, inflammation, morphology, immunology, and fibrinolysis. RESULTS: Laparoscopic surgery induces alterations in the peritoneal integrity and causes local acidosis, probably due to peritoneal hypoxia. The local immune system and inflammation are modulated by a pneumoperitoneum. Additionally, the peritoneal plasmin system is inhibited, leading to peritoneal hypofibrinolysis. CONCLUSION: Similar to open surgery, laparoscopic surgery affects both the integrity and biology of the peritoneum. These observations may have implications for various clinical conditions.


Asunto(s)
Laparoscopía/efectos adversos , Cavidad Peritoneal/fisiopatología , Peritoneo/fisiopatología , Neumoperitoneo Artificial/efectos adversos , Acidosis/etiología , Animales , Dióxido de Carbono/administración & dosificación , Dióxido de Carbono/efectos adversos , Moléculas de Adhesión Celular/metabolismo , Hipoxia de la Célula , Citocinas/metabolismo , Epitelio/patología , Fibrinolisina/fisiología , Fibrinólisis , Humanos , Péptidos y Proteínas de Señalización Intercelular/metabolismo , Macrófagos Peritoneales/fisiología , Ratones , Siembra Neoplásica , Cavidad Peritoneal/cirugía , Neoplasias Peritoneales/secundario , Peritoneo/inmunología , Peritoneo/cirugía , Peritonitis/etiología , Peritonitis/fisiopatología , Adherencias Tisulares/etiología , Adherencias Tisulares/fisiopatología , Cicatrización de Heridas/fisiología
17.
Eur J Vasc Endovasc Surg ; 40(1): 27-34, 2010 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-20399124

RESUMEN

BACKGROUND: Subclavian artery aneurysms (SAAs) are rare and may cause life- and limb-threatening complications. Therapeutic options greatly differ as do access alternatives. The aim of the study was to assess its clinical presentation, diagnostics and therapeutic options as reported in the literature. METHOD: A literature search was performed of the Medline, Cochrane and EMBASE databases. All articles, published until September 2009, describing treatment of an SAA were included. RESULTS: A total of 191 reports, of which 126 met the inclusion criteria, were identified and were published from June 1915 until September 2009. Of these, 394 SAAs were described in 381 patients, with a mean age of 52+/-16 years. The median diameter was 40 mm (range: 10-180 mm). The aetiology appeared to change in time towards more exogenous causes. Fifty-one percent of the SAAs presented with a pulsating mass, shoulder pain and/or non-specific chest pain. Embolisation, rupture and thrombosis were present in 16%, 9% and 6% of patients, respectively, and their incidence was related to the anatomical localisation of the SAA. Open surgery and endovascular repair had a complication rate of 26% and 28%, respectively (p=0.49). Cardiopulmonary complications were restricted to open repair. Mortality rates for open and endovascular techniques were similar (5%). The mortality rates for conventional elective and emergency procedures were 3% and 13%, respectively, and for endovascular repair 4% and 8%, respectively. CONCLUSION: The profiles of diagnostic and treatment options of SAAs are changing. Although guidelines considering timing of intervention may not be conducted from available literature, intervention appears to be indicated, especially in distal SAAs, due to the risk of thrombo-embolic complications. Endovascular repair and hybrid procedures appear to be the preferred treatment modalities, due to a lower rate of cardiopulmonary complications.


Asunto(s)
Aneurisma/diagnóstico , Aneurisma/cirugía , Arteria Subclavia/patología , Arteria Subclavia/cirugía , Procedimientos Quirúrgicos Vasculares , Aneurisma/etiología , Aneurisma/mortalidad , Medicina Basada en la Evidencia , Humanos , Selección de Paciente , Guías de Práctica Clínica como Asunto , Valor Predictivo de las Pruebas , Medición de Riesgo , Factores de Riesgo , Resultado del Tratamiento , Procedimientos Quirúrgicos Vasculares/efectos adversos , Procedimientos Quirúrgicos Vasculares/mortalidad
18.
Eur J Vasc Endovasc Surg ; 37(5): 585-91, 2009 May.
Artículo en Inglés | MEDLINE | ID: mdl-19231248

RESUMEN

BACKGROUND: A persistent sciatic artery (PSA) is a rare vascular anomaly with an estimated incidence of 0.03-0.06%. During early embryonic development, the sciatic artery usually disappears when the superficial femoral artery has developed properly. This study aimed to assess the clinical presentation and outcome of a PSA. METHOD: A systematic review of all cases of PSA published between 1964 and 2007 was performed. RESULTS: In this review, 159 PSAs were described in 122 patients. The mean age at which the PSA was discovered was 57 years, and the incidence was equally distributed with regards to gender. The majority of PSAs was unilateral (70%) and of the complete type (79%). Ninety-one patients (80%) presented with symptoms including intermittent claudication, ischaemia, a pulsating mass or neurological symptoms. An aneurysm was found in 48%, a stenosis in 7%, an occlusion of the PSA in 9% and an occlusion of an artery distal to the PSA in 6% of the subjects. The treatment depended on the symptoms and classification of the PSA. In nine cases (8%), an amputation was required eventually. CONCLUSION: The PSA is a rare anomaly with a high incidence of complications including aneurysm formation and ischaemia that may lead to amputation. Strategies for follow-up could not be deduced from the available literature.


Asunto(s)
Malformaciones Arteriovenosas , Pierna/irrigación sanguínea , Procedimientos Quirúrgicos Vasculares/métodos , Angiografía , Malformaciones Arteriovenosas/diagnóstico , Malformaciones Arteriovenosas/epidemiología , Malformaciones Arteriovenosas/cirugía , Diagnóstico Diferencial , Salud Global , Humanos , Incidencia , Pronóstico , Stents , Ultrasonografía Doppler
19.
Emerg Radiol ; 16(5): 387-9, 2009 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-18982368

RESUMEN

A case of right middle lobe torsion occurring after a right upper lobectomy is described. HR-CT angiography was successful in identifying the obstructed right middle lobe bronchus and the avascular nature of the infected and displaced right middle lobe. This detailed information, obtainable from present day multislice HR-CT scanners with the right CT protocols, seems to diminish the need for further confirmation by other methods.


Asunto(s)
Bronquios , Tomografía Computarizada por Rayos X , Anomalía Torsional/diagnóstico por imagen , Anciano , Humanos , Masculino , Anomalía Torsional/diagnóstico
20.
Eur J Vasc Endovasc Surg ; 35(2): 198-204, 2008 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-17964193

RESUMEN

BACKGROUND: During the last decade endovascular therapy has been established as an alternative treatment for a variety of vascular diseases. Neither the classic operating room (OR), nor the conventional angiography suite is optimal for both open surgery and endovascular procedures. Important issues include: quality of the imaging equipment, radiation burden, ease of use of the equipment, need for specially trained personnel, ergonomics, ability to perform both open and percutaneous procedures, sterile environments, as well as quality and efficiency of patient care. METHODS: A literature search identified articles pertinent to the key issues during the decision-making process of creating the optimal endovascular suite. Manual cross-referencing also was performed. RESULTS AND CONCLUSION: The most important feature of working in a dedicated endovascular suite should be the ability to attain best treatment of vascular patients. Whether the interventional radiologist or the vascular surgeon uses the facilities is of less importance. A fixed fluoroscopy unit is preferred, above a portable C-arm. Establishment of an endovascular operating room suite has the benefit of a sterile environment, the possibility of performing hybrid procedures and conversions when necessary. Moreover, angiography immediately before treatment gives contemporary anatomical information, and after treatment provides quality control. As a consequence, better quality and service can be provided to the individual patient.


Asunto(s)
Quirófanos/organización & administración , Evaluación de Procesos y Resultados en Atención de Salud , Radiología Intervencionista/organización & administración , Enfermedades Vasculares/cirugía , Procedimientos Quirúrgicos Vasculares/organización & administración , Eficiencia Organizacional , Diseño de Equipo , Ergonomía , Humanos , Procedimientos Quirúrgicos Mínimamente Invasivos , Quirófanos/normas , Control de Calidad , Radiología Intervencionista/instrumentación , Radiología Intervencionista/normas , Procedimientos Quirúrgicos Vasculares/instrumentación , Procedimientos Quirúrgicos Vasculares/normas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA