Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo de estudio
Idioma
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Guang Pu Xue Yu Guang Pu Fen Xi ; 25(6): 844-7, 2005 Jun.
Artículo en Zh | MEDLINE | ID: mdl-16201354

RESUMEN

Based on the chemiluminescence reaction of KMnO4-HNO3-2,3,5,4'-tetrahydroxystilbene-2-O-beta-D-glucoside sensitized by HCHO, an analytical method for 2,3,5,4'-tetrahydroxystilbene-2-O-beta-D-glucoside by RP-HPLC with chemiluminescence detector was developed. The chromatographic conditions were optimized. AN ODS hypersil column(25 mm x 4.0 mm, 125 x 4.0 mm i.d. 5 microm) was used with acetonitrile--0.3% H3PO4 [25:75, (phi)] as mobile phase, and the flow rate was 0.8 mL x min(-1) at the column temperature of 40 degrees C. The linear range of calibration curve was from 15.75 to 136.5 microg x mL(-1), the detection limit was 11.83 microg x mL(-1) with a concentration of 21 microg x mL(-1) of 2,3,5,4'-tetrahydroxystilbene-2-O-beta-D-glucoside, and the recovery was 102%-108%. The relative standard deviation was 3.45% (Cs = 21.0 microg x mL(-1), n = 3). The method has been applied to the determination of 2,3,5,4'-tetrahydroxystilbene-2-O-beta-D-glucoside in a few Chinese medicines, and the results were satisfactory. The method was simple, rapid and highly selective.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Medicamentos Herbarios Chinos/química , Glucósidos/análisis , Luminiscencia , Estilbenos/análisis , Cápsulas , Cromatografía Líquida de Alta Presión/instrumentación , Formaldehído/química , Glucósidos/química , Cinética , Mediciones Luminiscentes/instrumentación , Mediciones Luminiscentes/métodos , Estructura Molecular , Ácido Nítrico/química , Reproducibilidad de los Resultados , Estilbenos/química , Comprimidos
2.
Guang Pu Xue Yu Guang Pu Fen Xi ; 24(4): 399-401, 2004 Apr.
Artículo en Zh | MEDLINE | ID: mdl-15766140

RESUMEN

A novel chemiluminescence method for the determination of Levofloxacin is based on its enhancement effect on thereaction of luminol with H2O2. The calibration graph is linear over the range of 5.53 x 10(-11)-2.21 x 10(-8) mol x L(-1) and the detection limit is 1.38 x 10(-11) mol x L(-1). The relative standard deviation (RSD) is 2.56% (n = 9). The method has been successfully applied to the determination of Levofloxacin in capsule samples.


Asunto(s)
Levofloxacino , Luminiscencia , Mediciones Luminiscentes/métodos , Luminol/química , Ofloxacino/análisis , Preparaciones Farmacéuticas/análisis , Calibración , Análisis de Inyección de Flujo , Peróxido de Hidrógeno/química , Límite de Detección
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA