RESUMEN
BACKGROUND: One third of patients undergoing transcatheter aortic-valve implantation (TAVI) have an indication for oral anticoagulation owing to concomitant diseases. Interruption of oral anticoagulation during TAVI may decrease the risk of bleeding, whereas continuation may decrease the risk of thromboembolism. METHODS: We conducted an international, open-label, randomized, noninferiority trial involving patients who were receiving oral anticoagulants and were planning to undergo TAVI. Patients were randomly assigned in a 1:1 ratio to periprocedural continuation or interruption of oral anticoagulation. The primary outcome was a composite of death from cardiovascular causes, stroke from any cause, myocardial infarction, major vascular complications, or major bleeding within 30 days after TAVI. RESULTS: A total of 858 patients were included in the modified intention-to-treat population: 431 were assigned to continuation and 427 to interruption of oral anticoagulation. A primary-outcome event occurred in 71 patients (16.5%) in the continuation group and in 63 (14.8%) in the interruption group (risk difference, 1.7 percentage points; 95% confidence interval [CI], -3.1 to 6.6; P = 0.18 for noninferiority). Thromboembolic events occurred in 38 patients (8.8%) in the continuation group and in 35 (8.2%) in the interruption group (risk difference, 0.6 percentage points; 95% CI, -3.1 to 4.4). Bleeding occurred in 134 patients (31.1%) in the continuation group and in 91 (21.3%) in the interruption group (risk difference, 9.8 percentage points; 95% CI, 3.9 to 15.6). CONCLUSIONS: In patients undergoing TAVI with a concomitant indication for oral anticoagulation, periprocedural continuation was not noninferior to interruption of oral anticoagulation during TAVI with respect to the incidence of a composite of death from cardiovascular causes, stroke, myocardial infarction, major vascular complications, or major bleeding at 30 days. (Funded by the Netherlands Organization for Health Research and Development and the St. Antonius Research Fund; POPular PAUSE TAVI ClinicalTrials.gov number, NCT04437303.).
RESUMEN
BACKGROUND: Transcatheter aortic valve implantation is an established, guideline-endorsed treatment for severe aortic stenosis. Precise sizing of the balloon-expandable Myval transcatheter heart valve (THV) series with the aortic annulus is facilitated by increasing its diameter in 1·5 mm increments, compared with the usual 3 mm increments in valve size. The LANDMARK trial aimed to show non-inferiority of the Myval THV series compared with the contemporary THVs Sapien Series (Edwards Lifesciences, Irvine, CA, USA) or Evolut Series (Medtronic, Minneapolis, MN, USA). METHODS: In this prospective, multinational, randomised, open-label, non-inferiority trial across 31 hospitals in 16 countries (Germany, France, Sweden, the Netherlands, Italy, Spain, New Zealand, Portugal, Greece, Hungary, Poland, Slovakia, Slovenia, Croatia, Estonia, and Brazil), 768 participants with severe symptomatic native aortic stenosis were randomly assigned (1:1) to the Myval THV or a contemporary THV. Eligibility was primarily decided by the heart team in accordance with 2021 European Society of Cardiology guidelines. As per the criteria of the third Valve Academic Research Consortium, the primary endpoint at 30 days was a composite of all-cause mortality, all stroke, bleeding (types 3 and 4), acute kidney injury (stages 2-4), major vascular complications, moderate or severe prosthetic valve regurgitation, and conduction system disturbances resulting in a permanent pacemaker implantation. Non-inferiority of the study device was tested in the intention-to-treat population using a non-inferiority margin of 10·44% and assuming an event rate of 26·10%. This trial is registered with ClinicalTrials.gov, NCT04275726, and EudraCT, 2020-000137-40, and is closed to new participants. FINDINGS: Between Jan 6, 2021, and Dec 5, 2023, 768 participants with severe symptomatic native aortic stenosis were randomly assigned, 384 to the Myval THV and 384 to a contemporary THV. 369 (48%) participants had their sex recorded as female, and 399 (52%) as male. The mean age of participants was 80·0 years (SD 5·7) for those treated with the Myval THV and 80·4 years (5·4) for those treated with a contemporary THV. Median Society of Thoracic Surgeons scores were the same in both groups (Myval 2·6% [IQR 1·7-4·0] vs contemporary 2·6% [1·7-4·0]). The primary endpoint showed non-inferiority of the Myval (25%) compared with contemporary THV (27%), with a risk difference of -2·3% (one-sided upper 95% CI 3·8, pnon-inferiority<0·0001). No significant difference was seen in individual components of the primary composite endpoint. INTERPRETATION: In individuals with severe symptomatic native aortic stenosis, the Myval THV met its primary endpoint at 30 days. FUNDING: Meril Life Sciences.
Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Complicaciones Posoperatorias/epidemiología , Estudios Prospectivos , Diseño de Prótesis , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del TratamientoRESUMEN
BACKGROUND: Transcatheter aortic valve implantation (TAVI) is an established treatment option for patients with severe aortic valve stenosis, but is still associated with relatively high rates of pacemaker implantation and paravalvular regurgitation. Routine preoperative computed tomography (CT) combined with patient-specific computer modelling can predict the interaction between the TAVI device and the patient's unique anatomy, allowing physicians to assess the risk for paravalvular regurgitation and conduction disorders in advance to the procedure. The aim of this trial is to assess potential improvement in the procedural outcome of TAVI by applying CT-based patient-specific computer simulations in patients with suitable anatomy for TAVI. METHODS: The GUIDE-TAVI trial is an international multicenter randomized controlled trial including patients accepted for TAVI by the Heart Team. Patients enrolled in the study will be randomized into 2 arms of each 227 patients. In patients randomized to the use of FEops HEARTGuide (FHG), patient-specific computer simulation with FHG is performed in addition to routine preoperative CT imaging and results of the FHG are available to the operator(s) prior to the scheduled intervention. In patients randomized to no use of FHG, only routine preoperative CT imaging is performed. The primary objective is to evaluate whether the use of FHG will reduce the incidence of mild to severe PVR, according to the Valve Academic Research Consortium 3. Secondary endpoints include the incidence of new conduction disorders requiring permanent pacemaker implantation, the difference between preoperative and final selected valve size, the difference between target and final implantation depth, change of preoperative decision, failure to implant valve, early safety composite endpoint and quality of life. CONCLUSIONS: The GUIDE-TAVI trial is the first multicenter randomized controlled trial to evaluate the value of 3-dimensional computer simulations in addition to standard preprocedural planning in TAVI procedures.
Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/cirugía , Simulación por Computador , Calidad de Vida , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Tomografía Computarizada por Rayos X/efectos adversos , Resultado del Tratamiento , Prótesis Valvulares Cardíacas/efectos adversosRESUMEN
BACKGROUND: The effect of single as compared with dual antiplatelet treatment on bleeding and thromboembolic events after transcatheter aortic-valve implantation (TAVI) in patients who do not have an indication for long-term anticoagulation has not been well studied. METHODS: In a randomized, controlled trial, we assigned a subgroup of patients who were undergoing TAVI and did not have an indication for long-term anticoagulation, in a 1:1 ratio, to receive aspirin alone or aspirin plus clopidogrel for 3 months. The two primary outcomes were all bleeding (including minor, major, and life-threatening or disabling bleeding) and non-procedure-related bleeding over a period of 12 months. Most bleeding at the TAVI puncture site was counted as non-procedure-related. The two secondary outcomes were a composite of death from cardiovascular causes, non-procedure-related bleeding, stroke, or myocardial infarction (secondary composite 1) and a composite of death from cardiovascular causes, ischemic stroke, or myocardial infarction (secondary composite 2) at 1 year, with both outcomes tested sequentially for noninferiority (noninferiority margin, 7.5 percentage points) and superiority. RESULTS: A total of 331 patients were assigned to receive aspirin alone and 334 were assigned to receive aspirin plus clopidogrel. A bleeding event occurred in 50 patients (15.1%) receiving aspirin alone and in 89 (26.6%) receiving aspirin plus clopidogrel (risk ratio, 0.57; 95% confidence interval [CI], 0.42 to 0.77; P = 0.001). Non-procedure-related bleeding occurred in 50 patients (15.1%) and 83 patients (24.9%), respectively (risk ratio, 0.61; 95% CI, 0.44 to 0.83; P = 0.005). A secondary composite 1 event occurred in 76 patients (23.0%) receiving aspirin alone and in 104 (31.1%) receiving aspirin plus clopidogrel (difference, -8.2 percentage points; 95% CI for noninferiority, -14.9 to -1.5; P<0.001; risk ratio, 0.74; 95% CI for superiority, 0.57 to 0.95; P = 0.04). A secondary composite 2 event occurred in 32 patients (9.7%) and 33 patients (9.9%), respectively (difference, -0.2 percentage points; 95% CI for noninferiority, -4.7 to 4.3; P = 0.004; risk ratio, 0.98; 95% CI for superiority, 0.62 to 1.55; P = 0.93). A total of 44 patients (13.3%) and 32 (9.6%), respectively, received oral anticoagulation during the trial. CONCLUSIONS: Among patients undergoing TAVI who did not have an indication for oral anticoagulation, the incidence of bleeding and the composite of bleeding or thromboembolic events at 1 year were significantly less frequent with aspirin than with aspirin plus clopidogrel administered for 3 months. (Funded by the Netherlands Organization for Health Research and Development; POPular TAVI EU Clinical Trials Register number, 2013-003125-28; ClinicalTrials.gov number, NCT02247128.).
Asunto(s)
Aspirina/uso terapéutico , Clopidogrel/uso terapéutico , Hemorragia/inducido químicamente , Inhibidores de Agregación Plaquetaria/uso terapéutico , Trombosis/prevención & control , Reemplazo de la Válvula Aórtica Transcatéter , Administración Oral , Anciano , Anciano de 80 o más Años , Aspirina/efectos adversos , Enfermedades Cardiovasculares/epidemiología , Enfermedades Cardiovasculares/mortalidad , Clopidogrel/efectos adversos , Quimioterapia Combinada , Femenino , Hemorragia/epidemiología , Humanos , Incidencia , Masculino , Inhibidores de Agregación Plaquetaria/efectos adversos , Periodo Posoperatorio , Trombosis/epidemiologíaRESUMEN
BACKGROUND: The roles of anticoagulation alone or with an antiplatelet agent after transcatheter aortic-valve implantation (TAVI) have not been well studied. METHODS: We performed a randomized trial of clopidogrel in patients undergoing TAVI who were receiving oral anticoagulation for appropriate indications. Patients were assigned before TAVI in a 1:1 ratio not to receive clopidogrel or to receive clopidogrel for 3 months. The two primary outcomes were all bleeding and non-procedure-related bleeding over a period of 12 months. Procedure-related bleeding was defined as Bleeding Academic Research Consortium type 4 severe bleeding, and therefore most bleeding at the puncture site was counted as non-procedure-related. The two secondary outcomes were a composite of death from cardiovascular causes, non-procedure-related bleeding, stroke, or myocardial infarction at 12 months (secondary composite 1) and a composite of death from cardiovascular causes, ischemic stroke, or myocardial infarction (secondary composite 2), both tested for noninferiority (noninferiority margin, 7.5 percentage points) and superiority. RESULTS: Bleeding occurred in 34 of the 157 patients (21.7%) receiving oral anticoagulation alone and in 54 of the 156 (34.6%) receiving oral anticoagulation plus clopidogrel (risk ratio, 0.63; 95% confidence interval [CI], 0.43 to 0.90; P = 0.01); most bleeding events were at the TAVI access site. Non-procedure-related bleeding occurred in 34 patients (21.7%) and in 53 (34.0%), respectively (risk ratio, 0.64; 95% CI, 0.44 to 0.92; P = 0.02). Most bleeding occurred in the first month and was minor. A secondary composite 1 event occurred in 49 patients (31.2%) receiving oral anticoagulation alone and in 71 (45.5%) receiving oral anticoagulation plus clopidogrel (difference, -14.3 percentage points; 95% CI for noninferiority, -25.0 to -3.6; risk ratio, 0.69; 95% CI for superiority, 0.51 to 0.92). A secondary composite 2 event occurred in 21 patients (13.4%) and in 27 (17.3%), respectively (difference, -3.9 percentage points; 95% CI for noninferiority, -11.9 to 4.0; risk ratio, 0.77; 95% CI for superiority, 0.46 to 1.31). CONCLUSIONS: In patients undergoing TAVI who were receiving oral anticoagulation, the incidence of serious bleeding over a period of 1 month or 1 year was lower with oral anticoagulation alone than with oral anticoagulation plus clopidogrel. (Funded by the Netherlands Organization for Health Research and Development; POPular TAVI EU Clinical Trials Register number, 2013-003125-28; ClinicalTrials.gov number, NCT02247128.).
Asunto(s)
Anticoagulantes/uso terapéutico , Clopidogrel/uso terapéutico , Hemorragia/inducido químicamente , Inhibidores de Agregación Plaquetaria/uso terapéutico , Reemplazo de la Válvula Aórtica Transcatéter , Administración Oral , Anciano , Anciano de 80 o más Años , Anticoagulantes/efectos adversos , Enfermedades Cardiovasculares/epidemiología , Enfermedades Cardiovasculares/mortalidad , Clopidogrel/efectos adversos , Quimioterapia Combinada , Hemorragia/epidemiología , Humanos , Incidencia , Estimación de Kaplan-Meier , Masculino , Inhibidores de Agregación Plaquetaria/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversosRESUMEN
BACKGROUND: Approximately 15% of saphenous vein grafts (SVGs) occlude during the first year after coronary artery bypass graft surgery (CABG) despite aspirin use. The POPular CABG trial (The Effect of Ticagrelor on Saphenous Vein Graft Patency in Patients Undergoing Coronary Artery Bypass Grafting Surgery) investigated whether ticagrelor added to standard aspirin improves SVG patency at 1 year after CABG. METHODS: In this investigator-initiated, randomized, double-blind, placebo-controlled, multicenter trial, patients with ≥1 SVGs were randomly assigned (1:1) after CABG to ticagrelor or placebo added to standard aspirin (80 mg or 100 mg). The primary outcome was SVG occlusion at 1 year, assessed with coronary computed tomography angiography, in all patients that had primary outcome imaging available. A generalized estimating equation model was used to perform the primary analysis per SVG. The secondary outcome was 1-year SVG failure, which was a composite of SVG occlusion, SVG revascularization, myocardial infarction in myocardial territory supplied by a SVG, or sudden death. RESULTS: Among 499 randomly assigned patients, the mean age was 67.9±8.3 years, 87.1% were male, the indication for CABG was acute coronary syndrome in 31.3%, and 95.2% of procedures used cardiopulmonary bypass. Primary outcome imaging was available in 220 patients in the ticagrelor group and 223 patients in the placebo group. The SVG occlusion rate in the ticagrelor group was 10.5% (51 of 484 SVGs) versus 9.1% in the placebo group (43 of 470 SVGs), odds ratio, 1.29 [95% CI, 0.73-2.30]; P=0.38. SVG failure occurred in 35 (14.2%) patients in the ticagrelor group versus 29 (11.6%) patients in the placebo group (odds ratio, 1.22 [95% CI, 0.72-2.05]). CONCLUSIONS: In this randomized, placebo-controlled trial, the addition of ticagrelor to standard aspirin did not reduce SVG occlusion at 1 year after CABG. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02352402.
Asunto(s)
Síndrome Coronario Agudo , Aspirina/administración & dosificación , Angiografía Coronaria , Puente de Arteria Coronaria , Oclusión de Injerto Vascular , Vena Safena/fisiopatología , Ticagrelor/administración & dosificación , Grado de Desobstrucción Vascular/efectos de los fármacos , Síndrome Coronario Agudo/diagnóstico por imagen , Síndrome Coronario Agudo/fisiopatología , Síndrome Coronario Agudo/cirugía , Anciano , Aspirina/efectos adversos , Método Doble Ciego , Femenino , Oclusión de Injerto Vascular/etiología , Oclusión de Injerto Vascular/fisiopatología , Oclusión de Injerto Vascular/prevención & control , Humanos , Masculino , Persona de Mediana Edad , Ticagrelor/efectos adversosRESUMEN
BACKGROUND: Measuring and improving outcomes is a central element of value-based health care. However, selecting improvement interventions based on outcome measures is complex and tools to support the selection process are lacking. The goal was to present strategies for the systematic identification and selection of improvement interventions applied to the case of aortic valve disease and to combine various methods of process and outcome assessment into one integrated approach for quality improvement. METHODS: For this case study a concept-driven mixed-method approach was applied for the identification of improvement intervention clusters including: (1) benchmarking outcomes, (2) data exploration, (3) care delivery process analysis, and (4) monitoring of ongoing improvements. The main outcome measures were long-term survival and 30-day mortality. For the selection of an improvement intervention, the causal relations between the potential improvement interventions and outcome measures were quantified followed by a team selection based on consensus from a multidisciplinary team of professionals. RESULTS: The study resulted in a toolbox: the Intervention Selection Toolbox (IST). The toolbox comprises two phases: (a) identifying potential for improvement, and (b) selecting an effective intervention from the four clusters expected to lead to the desired improvement in outcomes. The improvements identified for the case of aortic valve disease with impact on long-term survival in the context of the studied hospital in 2015 include: anticoagulation policy, increased attention to nutritional status of patients and determining frailty of patients before the treatment decision. CONCLUSIONS: Identifying potential for improvement and carefully selecting improvement interventions based on (clinical) outcome data demands a multifaceted approach. Our toolbox integrates both care delivery process analyses and outcome analyses. The toolbox is recommended for use in hospital care for the selection of high-impact improvement interventions.
Asunto(s)
Atención a la Salud/normas , Cardiopatías Congénitas , Enfermedades de las Válvulas Cardíacas , Mejoramiento de la Calidad , Resultado del Tratamiento , Válvula Aórtica/fisiopatología , Benchmarking , Enfermedad de la Válvula Aórtica Bicúspide , Servicios de Salud , Cardiopatías Congénitas/mortalidad , Enfermedades de las Válvulas Cardíacas/mortalidad , Hospitales , Humanos , Evaluación de Resultado en la Atención de SaludRESUMEN
PURPOSE OF REVIEW: The TAVR procedure is a well-established therapy for patients with severe aortic stenosis at intermediate/high risk for surgery and a potential treatment for low-risk patients. It is much less invasive with short hospital stays and presents similar results compared with SAVR. Different "minimalist approach strategies" were proposed in order to obtain this performance. In these settings, transesophageal echocardiography (TEE) became less relevant for the TAVR procedure. The present review provides an update regarding the safety of TAVR without intraprocedural TEE. RECENT FINDINGS: Transthoracic echocardiography and fluoroscopy are the primary imaging tools during TAVR. Several studies proved that TAVR under local anesthesia without TEE is as safe as that performed under TEE guidance. However, not all patients have a proper window for TTE, and particular cases with complex anatomy can benefit from TEE support during the intervention. Intraprocedural TEE no longer plays a crucial role in the TAVR procedure, but in some instances, it remains of great help to detect and avoid complications.
Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Estenosis de la Válvula Aórtica/cirugía , Ecocardiografía , Ecocardiografía Transesofágica , Humanos , Resultado del TratamientoRESUMEN
OBJECTIVE: The aim of this study was to describe the early use of dedicated patient specific computer modeling in patients with bicuspid aortic valve (BAV) undergoing transcatheter aortic valve implantation (TAVI), in predicting procedure feasibility and patient related outcome. BACKGROUND: Dedicated patient specific computer modeling, used for optimizing TAVI procedures, is currently validated for the prediction of contact pressure, valve morphology and paravalvular leakage (PVL). The simulation of TAVI procedures is increasingly used in patients with tricuspid aortic valve stenosis. Currently, BAV disease is considered as a relative contra-indication for TAVI due to its specific anatomical characteristics. METHODS: This single center study consisted of seven patients with BAV undergoing TAVI. A patient specific computer simulation was performed based on multislice computer tomography images. The model advised the best fitting prosthetic valve size or sizes and simulated this valve on different implantation depths with the corresponding presence and severity of PVL and prosthetic valve morphology. The simulation results were compared with the procedural outcomes using transesophageal echocardiography (TEE) and fluoroscopy. RESULTS: The patient specific computer modeling predicted accurately the outcome (PVL and valve morphology) of TAVI in all cases. In one case, the TAVI procedure was unsuccessful and retrospectively not suitable for TAVI, which was correctly predicted by the model. CONCLUSION: The patient specific computer modeling adequately predicts feasibility and outcome of TAVI in patients with BAV disease and may extend the applicability of TAVI. Moreover, it improves decision-making and therefore individual procedural outcomes in this difficult patient population.
Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/anomalías , Enfermedades de las Válvulas Cardíacas/complicaciones , Modelos Cardiovasculares , Modelación Específica para el Paciente , Cirugía Asistida por Computador , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/fisiopatología , Enfermedad de la Válvula Aórtica Bicúspide , Toma de Decisiones Clínicas , Técnicas de Apoyo para la Decisión , Estudios de Factibilidad , Femenino , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/fisiopatología , Prótesis Valvulares Cardíacas , Humanos , Masculino , Tomografía Computarizada Multidetector , Selección de Paciente , Diseño de Prótesis , Estudios Retrospectivos , Cirugía Asistida por Computador/efectos adversos , Cirugía Asistida por Computador/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Resultado del TratamientoRESUMEN
AIMS: Left atrial appendage closure (LAAC) is increasingly used as an alternative to oral anticoagulation (OAC) for stroke prevention in atrial fibrillation (AF) patients. Feasibility and safety of left atrial (LA) catheter ablation (CA) in patients with previously implanted LAAC devices have not been well studied. We report on the feasibility, safety, and efficacy of LA CA in the presence of a previously implanted LAAC device. METHODS AND RESULTS: In this prospective cohort study consecutive patients that underwent LA CA with a previously implanted Watchman device were included. Periprocedural characteristics and long-term clinical follow-up were evaluated. Twenty-three LA CA procedures were performed in 19/162 AF patients with previously implanted Watchman devices [47% male, age 63.9 ± 6.2 years, CHA2DS2-VASc 4.0 (3.0-5.0); HASBLED 3.0 (2.0-4.0); 63% paroxysmal]. Left atrial CA was performed with irrigated radiofrequency (RF; n = 20, 87%) or phased RF (n = 3, 13%) in a mean of 18 months after LAAC implantation (range 4-80 months). Targets of CA consisted of pulmonary vein isolation (n = 19, 83%), superior vena cava isolation (n = 13, 57%), and additional linear lesions (n = 8, 35%). Procedures were carried out under vitamin K antagonist (VKA; n = 6, 26%), non-VKA OAC (NOAC; n = 8, 35%), or single antiplatelet therapy alone (n = 9, 39%). Left atrial CA was successful without any signs of interference from the device. Procedure-related complications were not observed. During a mean follow-up of 28 months, 11 patients (58%) had AF recurrence. CONCLUSION: Left atrial CA after LAAC appears to be feasible, effective, and safe in this single centre cohort. Previously implanted Watchman device should not be a reason to relinquish CA in symptomatic AF patients, even in patients on single antiplatelet therapy alone.
Asunto(s)
Apéndice Atrial/fisiopatología , Fibrilación Atrial/terapia , Cateterismo Cardíaco/instrumentación , Ablación por Catéter , Venas Pulmonares/cirugía , Vena Cava Superior/cirugía , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Cateterismo Cardíaco/efectos adversos , Ablación por Catéter/efectos adversos , Bases de Datos Factuales , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Venas Pulmonares/fisiopatología , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Vena Cava Superior/fisiopatologíaRESUMEN
BACKGROUND: Value-based healthcare (VBHC) is a concept that focuses on outcome measurement to contribute to quality improvement. However, VBHC does not offer a systematic approach for implementing improvement as implementation science does. The aim is to, firstly, investigate the implementation of improvement initiatives in the context of VBHC and secondly, to explore how implementation science could be of added value for VBHC and vice versa. METHODS: A case study with two cases in heart care was conducted; one without the explicit use of a systematic implementation method and the other one with the use of the Implementation of Change Model (ICM). Triangulation of data from document research, semi-structured interviews and a focus group was applied to evaluate the degree of method uptake. Interviews were held with experts involved in the implementation of Case 1 (N = 4) and Case 2 (N = 7). The focus group was held with experts also involved in the interviews (N = 4). A theory-driven qualitative analysis was conducted using the ICM as a framework. RESULTS: In both cases, outcome measures were seen as an important starting point for the implementation and for monitoring change. Several themes were identified as most important: support, personal importance, involvement, leadership, climate and continuous monitoring. Success factors included intrinsic motivation for the change, speed of implementation, complexity and continuous evaluation. CONCLUSION: Application of the ICM facilitates successful implementation of quality- improvement initiatives within VBHC. However, the practical use of the ICM shows an emphasis on processes. We recommend that monitoring of outcomes be added as an essential part of the ICM. In the discussion, we propose an implementation model that integrates ICM within VBHC.
Asunto(s)
Atención a la Salud/normas , Servicios de Salud/normas , Mejoramiento de la Calidad , Procedimientos Quirúrgicos Cardíacos/métodos , Proteínas en la Dieta/administración & dosificación , Difusión de Innovaciones , Humanos , Ciencia de la Implementación , Liderazgo , Estudios Longitudinales , Evaluación de Resultado en la Atención de Salud , Cuidados Preoperatorios/métodos , Investigación CualitativaRESUMEN
PURPOSE OF REVIEW: This review aims to provide an updated overview and a clinical perspective on novel transcatheter tricuspid valve interventions (TTVI), highlighting potential challenges and future directions. RECENT FINDINGS: Severe tricuspid regurgitation (TR) is a predictor of mortality. However, a sizeable number of patients remain untreated until the end-stage when cardiac surgery presents a prohibitive risk. The emergent need in finding a treatment for patients with TR, deemed for surgery options, has encouraged the development of TTVI. These procedures mimic classical surgery techniques and are mainly divided in four categories: annuloplasty and coaptation devices, edge-to-edge techniques and transcatheter tricuspid valve replacement. Early studies showed promising results, but long-term follow-up data are not available. For patients with severe TR and high surgical risk, several percutaneous options are available. However, these therapies are in a growing phase and bigger studies and long term follow-up are needed to prove their efficacy.
Asunto(s)
Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Insuficiencia de la Válvula Tricúspide/cirugía , Válvula Tricúspide/cirugía , Humanos , Resultado del TratamientoRESUMEN
INTRODUCTION: Modern pacemakers are designed to allow patients to undergo magnetic resonance imaging (MRI) under a set of specific conditions. Aim of this study is to provide confirmatory evidence of safety and performance of a new pacing system (ImageReady™, Boston Scientific) in patients undergoing 1.5 and 3T MRI. METHODS AND RESULTS: Two prospective, nonrandomized, single-arm studies were designed to provide confirmatory data of no impact of MRI on device function, lead parameters, and patient conditions in subjects implanted with the system undergoing a clinically non-indicated 1.5T and 3T MRI, respectively. Device measurements were done within 1 hour before and after the scan and at 1 month follow-up. Thirty-two subjects underwent MRI visit (17 subjects with 1.5T MRI and 15 subjects with 3T MRI). There were no unanticipated adverse effects related to the pacemaker. Device measurements taken pre- and post-MRI scan did not show any clinical relevant change that could indicate an effect of the MRI on the device or at the lead-tissue interface (RV threshold change: 0.01 ± 0.13 V, P = 0.60; RA threshold change: 0.01 ± 0.11 V, P = 0.53; R wave change: -0.44 ± 1.73 mV, P = 0.36; R wave change: 0.12 ± 1.67 mV, P = 0.73), with data confirmed at 1-month follow-up visit. CONCLUSION: The study documented safety of the pacing system in the 1.5T and 3T MRI environment by showing no adverse events related to device or MRI scan. Additional data are required to cover the more complex scenarios involving different diagnostic needs, conditions of use, clinical conditions, and new emerging technologies.
Asunto(s)
Bloqueo Cardíaco/diagnóstico por imagen , Bloqueo Cardíaco/terapia , Imagen por Resonancia Cinemagnética/métodos , Marcapaso Artificial , Seguridad del Paciente , Anciano , Anciano de 80 o más Años , Electrocardiografía/métodos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Marcapaso Artificial/efectos adversos , Estudios ProspectivosAsunto(s)
Hipertensión Pulmonar/epidemiología , Sarcoidosis Pulmonar/fisiopatología , Adulto , Femenino , Volumen Espiratorio Forzado , Humanos , Hipertensión Pulmonar/fisiopatología , Masculino , Persona de Mediana Edad , Países Bajos/epidemiología , Prevalencia , Presión Esfenoidal Pulmonar , Resistencia Vascular , Capacidad Vital , Población BlancaRESUMEN
Background/Objectives: Paravalvular leak and permanent pacemaker implantation remain relevant issues after transcatheter aortic valve implantation (TAVI). Novel device development as well as adequate preprocedural device selection can contribute to optimal outcomes. Methods: Computed tomography-based patient-specific computer anatomical analysis and simulation were used in addition to standard preprocedural preparation in three of the first Evolut FX cases in our center. Procedural and follow-up echocardiographic outcomes are presented. Results: Computed tomography-based computer simulation of Evolut FX resulted in implantation of a different size in one of three cases. In three cases of severe aortic valve stenosis, procedural as well as follow-up outcomes were satisfactory and in line with the simulated results of the chosen strategy. Conclusions: Preprocedural patient-specific computer simulation predicts and guides decision-making in TAVI with the Evolut FX platform. The combination of advanced preprocedural technology and novel technologies continues to contribute to the optimization of TAVI outcomes.
RESUMEN
BACKGROUND: Left atrial appendage occlusion (LAAO) provides mechanical cardioembolic protection for atrial fibrillation (AF) patients who cannot use oral anticoagulation therapy (OAT). Patients with a thrombotic event despite OAT are at high risk for recurrence and may also benefit from LAAO. OBJECTIVES: This study sought to investigate the efficacy of LAAO in AF patients with a thrombotic event on OAT compared to: 1) LAAO in AF patients with a contraindication for OAT; and 2) historical data. METHODS: The international LAAO after stroke despite oral anticoagulation (STR-OAC LAAO) collaboration included patients who underwent LAAO because of thrombotic events on OAT. This cohort underwent propensity score matching and was compared to the EWOLUTION (Evaluating Real-Life Clinical Outcomes in Atrial Fibrillation Patients Receiving the WATCHMAN Left Atrial Appendage Closure Technology) registry, which represents patients who underwent LAAO because of OAT contraindications. The primary outcome was ischemic stroke. Event rates were compared between cohorts and with historical data without OAT, yielding relative risk reductions based on risk scores. RESULTS: Analysis of 438 matched pairs revealed no significant difference in the ischemic stroke rate between the STR-OAC LAAO and EWOLUTION cohorts (2.5% vs 1.9%; HR: 1.37; 95% CI: 0.72-2.61). STR-OAC LAAO patients exhibited a higher thromboembolic risk (HR: 1.71; 95% CI: 1.04-2.83) but lower bleeding risk (HR: 0.39; 95% CI: 0.18-0.88) compared to EWOLUTION patients. The mortality rate was slightly higher in EWOLUTION (4.3% vs 6.9%; log-rank P = 0.028). Relative risk reductions for ischemic stroke were 70% and 78% in STR-OAC LAAO and EWOLUTION, respectively, compared to historical data without OAT. CONCLUSIONS: LAAO in patients with a thrombotic event on OAT demonstrated comparable stroke rates to the OAT contraindicated population in EWOLUTION. The thromboembolic event rate was higher and the bleeding rate lower, reflecting the intrinsically different risk profile of both populations. Until randomized trials are available, LAAO may be considered in patients with an ischemic event on OAT.
Asunto(s)
Anticoagulantes , Apéndice Atrial , Fibrilación Atrial , Cateterismo Cardíaco , Contraindicaciones de los Medicamentos , Accidente Cerebrovascular Isquémico , Sistema de Registros , Humanos , Apéndice Atrial/fisiopatología , Apéndice Atrial/diagnóstico por imagen , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/complicaciones , Fibrilación Atrial/mortalidad , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/terapia , Femenino , Masculino , Anticoagulantes/efectos adversos , Anticoagulantes/administración & dosificación , Anciano , Factores de Riesgo , Medición de Riesgo , Anciano de 80 o más Años , Factores de Tiempo , Administración Oral , Accidente Cerebrovascular Isquémico/prevención & control , Accidente Cerebrovascular Isquémico/mortalidad , Accidente Cerebrovascular Isquémico/diagnóstico , Accidente Cerebrovascular Isquémico/etiología , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/mortalidad , Insuficiencia del Tratamiento , Hemorragia/inducido químicamente , Recurrencia , Persona de Mediana Edad , Estudios Retrospectivos , Europa (Continente)RESUMEN
Importance: Patients with atrial fibrillation (AF) who have ischemic stroke despite taking oral anticoagulation therapy (OAT) have a very high risk of recurrence. Left atrial appendage occlusion (LAAO) is a mechanical stroke prevention strategy that may provide additional protection in patients with thromboembolic events under OAT. Objective: To compare percutaneous LAAO with continuing OAT alone regarding stroke prevention in patients with AF who had a thromboembolic event despite taking OAT. Design, Setting, and Participants: This cohort study was a propensity score-matched comparison of the STR-OAC LAAO cohort, an international collaboration of 21 sites combining patients from multiple prospective registries of patients who underwent LAAO between 2010 and 2022. STR-OAC LAAO cohort patients who had follow-up longer than 3 months were propensity score-matched to a previously published control cohort comprising patients from an established international collaboration of investigator-initiated prospective studies. This control cohort included patients with nonvalvular AF, recent ischemic stroke or transient ischemic attack, and follow-up longer than 3 months who were taking OAT before the index event. Analyses were adjusted for imbalances in gender, age, hypertension, diabetes, and CHA2 DS2-VASc score. Exposure: Left atrial appendage occlusion vs continuation of oral anticoagulation therapy alone (control group). Main Outcomes and Measures: The primary outcome was time to first ischemic stroke. Results: Four hundred thirty-three patients from the STR-OAC LAAO cohort (mean [SD] age, 72 [9] years; 171 [39%] females and 262 [61%] males; mean [SD] CHA2 DS2-VASc score, 5.0 [1.6]) were matched to 433 of 1140 patients (38%) from the control group. During 2-year follow-up, 50 patients experienced ischemic stroke: an annualized event rate of 2.8% per patient-year in the STR-OAC LAAO group vs 8.9% per patient-year in the control group. Left atrial appendage occlusion was associated with a lower risk of ischemic stroke (hazard ratio, 0.33; 95% CI, 0.19-0.58; P < .001) compared with the control group. After LAAO, OAT was discontinued in 290 patients (67%), and the remaining 143 patients (33%) continued OAT after LAAO as an adjunctive therapy. Conclusions and Relevance: In patients with nonvalvular AF and a prior thromboembolic event despite taking OAT, LAAO was associated with a lower risk of ischemic stroke compared with continued OAT alone. Randomized clinical trial data are needed to confirm that LAAO may be a promising treatment option for this population with a very high risk of stroke.
RESUMEN
Background: Percutaneous left atrial appendage occlusion (LAAO) is an alternative to anticoagulation in the prevention of stroke in patients with nonvalvular atrial fibrillation, especially in patients with a contraindication for oral anticoagulation therapy (OAT). Objective: The study sought to obtain long-term patient outcomes after successful LAAO in everyday clinical practice. Methods: In this single-center registry spanning over 10 years, data of all consecutive patients that underwent percutaneous LAAO were collected. Observed thromboembolic and major bleeding event rates after successful LAAO during follow-up were compared with expected event rates based on CHA2DS2-VASc (congestive heart failure, hypertension, age ≥75 years, diabetes mellitus, prior stroke or transient ischemic attack or thromboembolism, vascular disease, age 65-74 years, sex category) and HAS-BLED (hypertension, abnormal renal or liver function, stroke, bleeding, labile international normalized ratio, elderly, drugs or alcohol) scores. Furthermore, anticoagulation and antiplatelet use during follow-up was evaluated. Results: Of 230 patients scheduled for LAAO (38% women, 69.5 ± 8.2 years of age, CHA2DS2-VASc score 3.9 ± 1.6, HAS-BLED score 2.9 ± 1.0), 218 patients had a successful implantation (95%) with a follow-up duration of 5.2 ± 3.1 years. The procedure was combined with catheter ablation in 52% of the patients. Fifty thromboembolic complications (24 ischemic stroke, 26 transient ischemic attack) were observed during follow-up in 40 (18%) of 218 patients. Ischemic strokes occurred with a rate of 2.1 per 100 patient-years, accounting for a 66% relative risk reduction compared with the CHA2DS2-VASc predicted event rate. Device-related thrombus was observed in 5 (2%) patients. Sixty-five nonprocedural major bleeding complications occurred in 24 (11%) of 218 patients with a rate of 5.7 per 100-patient years, which is comparable to estimated HAS-BLED-bleeding rates under OAT use. At end of follow-up 71% of all patients were on single antiplatelet or no antiplatelet or anticoagulation treatment, while 29% were on OAT. Conclusion: Thromboembolic event rates during long-term follow-up after successful LAAO remained consistently lower than expected supporting the efficacy of LAAO.
RESUMEN
About one-third of patients undergoing transcatheter aortic valve implantation (TAVI) use oral anticoagulants (OAC), mainly due to atrial fibrillation. General guidelines advise interrupting OAC in patients with a high risk of bleeding undergoing interventions. However, preliminary observational data suggest that the continuation of OAC during TAVI is safe and may reduce the risk of periprocedural thromboembolic events. The Periprocedural Continuation Versus Interruption of Oral Anticoagulant Drugs During Transcatheter Aortic Valve Implantation (POPular PAUSE TAVI) is a multicentre, randomised clinical trial with open-label treatment and blinded endpoint assessment. Patients are randomised 1:1 to periprocedural continuation versus interruption of OAC and are stratified for vitamin K antagonist or direct oral anticoagulant use. The primary endpoint is a composite of cardiovascular mortality, all stroke, myocardial infarction, major vascular complications and type 2-4 bleeding within 30 days after TAVI, according to the Valve Academic Research Consortium-3 criteria. Secondary endpoints include separate individual and composite outcomes, quality of life and cost-effectiveness. Since continuation of OAC is associated with the ancillary benefit that it simplifies periprocedural management, the primary outcome is first analysed for non-inferiority; if non-inferiority is proven, superiority will be tested. Recruitment started in November 2020, and the trial will continue until a total of 858 patients have been included and followed for 90 days. In summary, POPular PAUSE TAVI is the first randomised clinical trial to assess the safety and efficacy of periprocedural continuation versus interruption of OAC in patients undergoing TAVI.
Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Calidad de Vida , Anticoagulantes/uso terapéutico , Hemorragia , Resultado del Tratamiento , Válvula Aórtica/cirugía , Factores de RiesgoRESUMEN
Invasive fractional flow reserve (FFR) adoption remains low mainly due to procedural and operator related factors as well as costs. Alternatively, quantitative flow ratio (QFR) achieves a high accuracy mainly outside the intermediate zone without the need for hyperaemia and wire-use. We aimed to determine the diagnostic performance of QFR and to evaluate a QFR-FFR hybrid strategy in which FFR is measured only in the intermediate zone. This retrospective study included 289 consecutive patients who underwent invasive coronary angiography and FFR. QFR was calculated for all vessels in which FFR was measured. The QFR-FFR hybrid approach was modelled using the intermediate zone of 0.77-0.87 in which FFR-measurements are recommended. The sensitivity, specificity, and accuracy on a per vessel-based analysis were 84.6%, 86.3% and 85.6% for QFR and 88.0%, 92.9% and 90.3% for the QFR-FFR hybrid approach. The diagnostic accuracy of QFR-FFR hybrid strategy with invasive FFR measurement was 93.4% and resulted in a 56.7% reduction in the need for FFR. QFR has a good correlation and agreement with invasive FFR. A hybrid QFR-FFR approach could extend the use of QFR and reduces the proportion of invasive FFR-measurements needed while improving accuracy.