Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Clin Chem Lab Med ; 61(2): 332-338, 2023 01 27.
Artículo en Inglés | MEDLINE | ID: mdl-36323338

RESUMEN

OBJECTIVES: Anti-nucleocapsid (NC) antibodies are produced in response to SARS-CoV-2 infection. Therefore, they are well suited for the detection of a previous infection. Especially in the case of seroprevalence studies or during the evaluation of a novel in-vitro diagnostic test, samples have been stored at <-70 °C (short- and long-term) or 2-10 °C (short-term) before analysis. This study aimed to assess the impact of different storage conditions relevant to routine biobanking on anti-NC antibodies. METHODS: The preanalytical impact of short-term storage (84 [58-98] days) on <-70 °C and for 14 days at 2-10 °C was evaluated using samples from 111 donors of the MedUni Vienna Biobank. Long-term effects (443 [409-468] days) were assessed using 208 samples from Biobank Graz and 49 samples from Biobank Vienna. Anti-Nucleocapsid antibodies were measured employing electrochemiluminescence assays (Roche Anti-SARS-CoV-2). RESULTS: After short-term storage, the observed changes did not exceed the extent that could be explained by analytical variability. In contrast, results after long-term storage were approximately 20% higher and seemed to increase with storage duration. This effect was independent of the biobank from which the samples were obtained. Accordingly, the sensitivity increased from 92.6 to 95.3% (p=0.008). However, comparisons with data from Anti-Spike protein assays, where these deviations were not apparent, suggest that this deviation could also be explained by the analytical variability of the qualitative Anti-NC assay. CONCLUSIONS: Results from anti-NC antibodies are stable during short-term storage at <-70 °C and 2-10 °C. After long-term storage, a slight increase in sensitivity could not be ruled out.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , Glicoproteína de la Espiga del Coronavirus , COVID-19/diagnóstico , Estudios Seroepidemiológicos , Bancos de Muestras Biológicas , Anticuerpos Antivirales , Sensibilidad y Especificidad
2.
Clin Chem Lab Med ; 60(5): 701-706, 2022 04 26.
Artículo en Inglés | MEDLINE | ID: mdl-35085430

RESUMEN

OBJECTIVES: Peripheral blood mononuclear cells (PBMCs) are a versatile material for clinical routine as well as for research projects. However, their isolation via density gradient centrifugation is still time-consuming. When samples are taken beyond usual laboratory handling times, it may sometimes be necessary to pause the isolation process. Our aim was to evaluate the impact of delays up to 48 h after the density gradient centrifugation on PBMC yield, purity and viability. METHODS: PBMCs were isolated from samples of 20 donors, either with BD Vacutainer CPT tubes (CPT) or with the standard Ficoll method. Isolation was paused after initial density gradient centrifugation for 0, 24, or 48 h. PBMC yield (% output/input), purity (% PBMCs/total cells) and viability (% Annexin V-/propidium iodide-) were compared. RESULTS: The yield did not change significantly over time when CPT were used (55%/52%/47%), but did after isolation with the standard method (62%/40%[p<0.0001]/53%[p<0.01]). Purity was marginally affected if CPT were used (95%/93%[p=n.s./92%[p<0.05] vs. 97% for all time points with standard method). Whereas viable PBMCs decreased steadily for CPT isolates (62%/51%[p<0.001]/36%[p<0.0001]), after standard Ficoll gradient isolation, cell apoptosis was more pronounced already after 24 h delay, and viability did not further decrease after 48 h (64%/44%[p<0.0001]/40%[p<0.0001]). CONCLUSIONS: In conclusion, our findings suggest that while post-centrifugation delays ≥24 h might have only a minor effect on cell yield and purity, their impact on cell viability is substantial, even when CPT are used.


Asunto(s)
Leucocitos Mononucleares , Leucocitos , Separación Celular/métodos , Supervivencia Celular , Ficoll , Humanos
3.
Clin Chem Lab Med ; 55(7): 974-983, 2017 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-27988499

RESUMEN

BACKGROUND: Irreproducibility of scientific results constitutes an undesirably onerous economic burden and is in many cases caused by low-quality materials. Therefore, researchers are increasingly devoting their attention to the bioresources they use. In turn, those bioresources are required to validate their preanalytical processes in order to ensure best possible quality. The present study thus aimed to evaluate the impact of repeated temperature fluctuations, as they occur in most research biobanks due to repetitive opening and closing of freezer doors, on the stability of 26 biochemical analytes. METHODS: Serum of 43 individuals was randomly assigned to a fluctuation (n=21) and a control group (n=22). Serum of the fluctuation group underwent controlled temperature fluctuations (30 fluctuations <-75°C - <-65°C - <-75°C under real-life freezer conditions within 21 days). Control sera were stored at constant conditions. After 10, 20, and 30 fluctuations, results derived from the fluctuation group were compared to baseline and to the control group by means of general linear models. RESULTS: Sixteen biomarkers showed statistically significant changes over time, whereas only seven of those presented with diagnostically/clinically relevant changes at certain time points (aspartate aminotransferase, amylase, calcium, uric acid, creatinine, inorganic phosphate and total protein). However, there was no difference between the fluctuation and the control group. CONCLUSIONS: Some serum analytes are influenced by storage, even at temperatures as low as <-70°C. In contrast, we found no evidence that complex temperature fluctuations produced by storage of and access to biospecimens in biobank freezers generate any additional variability.


Asunto(s)
Recolección de Muestras de Sangre/métodos , Temperatura , Biomarcadores/sangre , Análisis Químico de la Sangre , Recolección de Muestras de Sangre/instrumentación , Congelación , Humanos , Factores de Tiempo
4.
J Clin Virol ; 158: 105345, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36462465

RESUMEN

OBJECTIVES: To investigate the comparability of WHO standard referenced commercial SARS-CoV-2 antibody tests over three doses of BNT162b2 vaccine and up to 14 months. METHODS: 114 subjects (without previous SARS-CoV-2 infection or immunosuppressive medication) vaccinated with three doses of BNT162b2 were included in this study. Antibody levels were quantified 3 weeks after the first dose, 5-6 weeks and 7 months after the second dose, and 4-5 weeks and 4 months after the third dose using the Roche Elecsys SARS-CoV-2 S, the Abbott SARS-CoV-2 IgG II Quant, the DiaSorin LIAISON SARS-CoV-2 TrimericS IgG, the GenScript cPASS sVNT and the TECO sVNT assays. RESULTS: For each time point analyzed, systematic differences are evident between the results in BAU/mL of the three antibody binding assays. The assay ratios change in a time-dependent manner even beyond administering the third dose (Roche measuring 9 and 3 times higher than Abbott and DiaSorin, respectively). However, changes decrease in magnitude with increasing time intervals from the first dose. IgG-based assays show better agreement across them than with Roche (overall correlations: Abbott x DiaSorin: ρ = 0.94 vs. Abbott x Roche: ρ=0.89, p < 0.0001; DiaSorin x Roche: ρ = 0.87, p < 0.0001), but results are not interchangeable. The sVNTs suggest an underestimation of antibody levels by Roche and slight overestimation by both IgG assays after the first vaccine dose. CONCLUSIONS: Standardization of SARS-CoV-2 antibody binding assays still needs to be improved to allow reliable use of variable assay systems for longitudinal analyses.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , Vacuna BNT162 , Anticuerpos Antivirales , Inmunoglobulina G
5.
Microbiol Spectr ; 10(1): e0140221, 2022 02 23.
Artículo en Inglés | MEDLINE | ID: mdl-35196824

RESUMEN

Various commercial anti-Spike SARS-CoV-2 antibody tests are used for studies and in clinical settings after vaccination. An international standard for SARS-CoV-2 antibodies has been established to achieve comparability of such tests, allowing conversions to BAU/mL. This study aimed to investigate the comparability of antibody tests regarding the timing of blood collection after vaccination. For this prospective observational study, antibody levels of 50 participants with homologous AZD1222 vaccination were evaluated at 3 and 11 weeks after the first dose and 3 weeks after the second dose using two commercial anti-Spike binding antibody assays (Roche and Abbott) and a surrogate neutralization assay. The correlation between Roche and Abbott changed significantly depending on the time point studied. Although Abbott provided values three times higher than Roche 3 weeks after the first dose, the values for Roche were twice as high as for Abbott 11 weeks after the first dose and 5 to 6 times higher at 3 weeks after the second dose. The comparability of quantitative anti-Spike SARS-CoV-2 antibody tests was highly dependent on the timing of blood collection after vaccination. Therefore, standardization of the timing of blood collection might be necessary for the comparability of different quantitative SARS-COV-2 antibody assays. IMPORTANCE This work showed that the comparability of apparently standardized SARS-CoV-2 antibody assays (Roche, Abbott; both given in BAU/mL) after vaccination depends on the time of blood withdrawal. Initially (3 weeks after the first dose AZD1222), there were 3 times higher values in the Abbott assay, but this relationship inversed before boosting (11 weeks after the first dose) with Roche 2 times greater than Abbott. After the booster, Roche quantified ca. 5 times higher levels than Abbott. This must be considered by clinicians when interpreting SARS-CoV-2 antibody levels.


Asunto(s)
Anticuerpos Antivirales/sangre , Vacunas contra la COVID-19/inmunología , COVID-19/diagnóstico , SARS-CoV-2/inmunología , Glicoproteína de la Espiga del Coronavirus/inmunología , Vacunación/tendencias , Adulto , COVID-19/inmunología , COVID-19/prevención & control , Vacunas contra la COVID-19/administración & dosificación , Humanos , Persona de Mediana Edad , Estudios Prospectivos , Factores de Tiempo , Vacunación/normas
6.
Int J Infect Dis ; 110: 309-313, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34332084

RESUMEN

OBJECTIVE: To determine whether severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) antibody levels after the first dose of vaccine can predict the final antibody response, and whether this is dependent on the vaccine type. METHODS: Sixty-nine recipients of BNT162b2 (Pfizer/BioNTech) and 55 recipients of AZD1222 (AstraZeneca), without previous infection or immunosuppressive medication, were included in this study. Antibody levels were quantified 3 weeks after the first dose [directly before boostering in the case of AZD1222 (11 weeks after the first dose)] and 3 weeks after the second dose using the Roche Elecsys SARS-CoV-2 S total antibody assay. RESULTS: Median pre-booster {BNT162b2: 80.6 [interquartile range (IQR) 25.5-167.0] binding antibody units (BAU)/mL; AZD1222: 56.4 (IQR 36.4-104.8) BAU/mL; not significant} and post-booster [BNT162b2: 2092.0 (IQR 1216.3-4431.8) BAU/mL; AZD1222: 957.0 (IQR 684.5-1684.8) BAU/mL; P<0.0001] levels correlated well in the recipients of BNT162b2 (ρ=0.53) but not in the recipients of AZD1222. Moreover, antibody levels after the first dose of BNT162b2 correlated inversely with age (ρ=-0.33, P=0.013), whereas a positive correlation with age was observed after the second dose in recipients of AZD1222 (ρ=0.26, P=0.030). CONCLUSIONS: The results of this study suggest that antibody levels quantified by the Roche Elecsys SARS-CoV-2 S assay before the booster shot could infer post-booster responses to BNT162b2, but not to AZ1222. In addition, this study found a vaccine-dependent effect on antibody responses, where age seems to play an ambivalent role.


Asunto(s)
COVID-19 , SARS-CoV-2 , Anticuerpos Antivirales , Vacuna BNT162 , Vacunas contra la COVID-19 , ChAdOx1 nCoV-19 , Humanos , Vacunación
7.
Psychophysiology ; 58(5): e13799, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33655551

RESUMEN

In an aging society, late-life depression has become an increasing problem. There is evidence that physical activity ameliorates depressive symptoms and increases the quality of life (QoL). However, the underlying mechanisms are still poorly understood. Myokines are molecules secreted in response to muscle contraction. Some of them can cross the blood-brain barrier, making them promising candidates for mediating the beneficial effects of physical activity on mood. The present study aims to compare circulating myokine levels to depression/QoL in older athletes and controls. 55 athletes, 57 controls >59 years were enrolled. The assessment included ergometry, magnetic resonance imaging, blood withdrawal, and neuropsychological testing. Serum interleukin-6 (IL-6), irisin, brain-derived neurotrophic factor (BDNF), kynurenine, and cathepsin B were analyzed and compared to surrogates of depression and quality of life. Athletes presented with higher levels of Cathepsin B. Among controls, all myokines but irisin were associated with age. Also, among controls, kynurenine and IL-6 correlated inversely with specific dimensions of quality of life questionnaires, and IL-6 further with depressive symptoms and decreased physical performance. No such associations could be found among athletes. Irisin levels were inversely associated with mild depression and low-grade white matter-lesions in the brain and predicted impaired QoL. The circulating levels of several myokines/muscle activity-related factors appear to be associated with depressive symptoms and impaired QoL among older adults. However, in athletes, some of these connections seem ameliorated, suggesting additional stressors (as f.e. age) or a different pathomechanism among athletes.


Asunto(s)
Atletas , Factor Neurotrófico Derivado del Encéfalo/metabolismo , Catepsina B/metabolismo , Depresión/metabolismo , Fibronectinas/metabolismo , Interleucina-6/metabolismo , Quinurenina/metabolismo , Calidad de Vida , Factores de Edad , Anciano , Estudios de Casos y Controles , Femenino , Humanos , Masculino , Carrera de Maratón , Persona de Mediana Edad , Rendimiento Físico Funcional , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA