Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Bases de datos
Tipo del documento
Asunto de la revista
Intervalo de año de publicación
1.
J Arthroplasty ; 39(9S1): S203-S207, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38897261

RESUMEN

BACKGROUND: Modular metaphyseal engaging (MME) femoral components in total hip arthroplasty (THA) allow optimized femoral length, offset, and anteversion and are useful in patients with unusual proximal femoral anatomy. Fretting, corrosion, and stem fractures above the modular sleeve are complications associated with these implants. The purpose of this study was to identify failure mechanisms of retrieved MME femoral components at our institution, identify all broken stem cases, and evaluate how often an extended trochanteric osteotomy (ETO) was required for removal. METHODS: All consecutively retrieved MME femoral components from September 2002 to May 2023 were reviewed. Patient demographics, procedure information, component specifications, indications for removal, and requirements for further revision surgery were reviewed. Descriptive statistics were calculated for variables of interest. RESULTS: There were 131 retrieved MME components. The mean age at surgery was 59 years (range, 28 to 75), 49% were women, mean body mass index was 29.4 (range, 20.7 to 33.3), and mean American Society of Anesthesiologists score was 2.4 ± 0.5. There were 102 (78%) stems of 1 design (stem A), and 29 (22%) stems of a different design (stem B). Of 131 components, 10 (7.6%) failed secondary to stem fracture proximal to the modular sleeve. Four of 102 (4%) of stem A and 6 of 29 (21% of stem B) fractured. All broken stems required additional intervention for removal during revision THA, using an ETO (N = 9) or cortical window (N = 1) in which an intraoperative proximal femoral fracture occurred. CONCLUSIONS: Broken MME stems present a challenge for orthopaedic surgeons during revision THA. When a stem fracture occurs above the ingrown sleeve, the distal splines may have osseous interdigitation into the clothespin. Thus, when revising a broken MME stem, an ETO should be performed, and the segment should be long enough to allow distal access.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Fémur , Prótesis de Cadera , Osteotomía , Falla de Prótesis , Reoperación , Humanos , Femenino , Masculino , Persona de Mediana Edad , Artroplastia de Reemplazo de Cadera/instrumentación , Artroplastia de Reemplazo de Cadera/métodos , Artroplastia de Reemplazo de Cadera/efectos adversos , Anciano , Osteotomía/métodos , Osteotomía/instrumentación , Osteotomía/efectos adversos , Prótesis de Cadera/efectos adversos , Fémur/cirugía , Adulto , Remoción de Dispositivos , Estudios Retrospectivos , Diseño de Prótesis
2.
Bone Joint J ; 106-B(3 Supple A): 115-120, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38423098

RESUMEN

Aims: Periprosthetic femoral fracture (PPF) is a major complication following total hip arthroplasty (THA). Uncemented femoral components are widely preferred in primary THA, but are associated with higher PPF risk than cemented components. Collared components have reduced PPF rates following uncemented primary THA compared to collarless components, while maintaining similar prosthetic designs. The purpose of this study was to analyze PPF rate between collarless and collared component designs in a consecutive cohort of posterior approach THAs performed by two high-volume surgeons. Methods: This retrospective series included 1,888 uncemented primary THAs using the posterior approach performed by two surgeons (PKS, JMV) from January 2016 to December 2022. Both surgeons switched from collarless to collared components in mid-2020, which was the only change in surgical practice. Data related to component design, PPF rate, and requirement for revision surgery were collected. A total of 1,123 patients (59.5%) received a collarless femoral component and 765 (40.5%) received a collared component. PPFs were identified using medical records and radiological imaging. Fracture rates between collared and collarless components were analyzed. Power analysis confirmed 80% power of the sample to detect a significant difference in PPF rates, and a Fisher's exact test was performed to determine an association between collared and collarless component use on PPF rates. Results: Overall, 17 PPFs occurred (0.9%). There were 16 fractures out of 1,123 collarless femoral components (1.42%) and one fracture out of 765 collared components (0.13%; p = 0.002). The majority of fractures (n = 14; 82.4%) occurred within 90 days of primary THA. There were ten reoperations for PPF with collarless components (0.89%) and one reoperation with a collared component (0.13%; p = 0.034). Conclusion: Collared femoral components were associated with significant decreases in PPF rate and reoperation rate for PPF compared to collarless components in uncemented primary THA. Future studies should investigate whether new-generation collared components reduce PPF rates with longer-term follow-up.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Fracturas del Fémur , Prótesis de Cadera , Fracturas Periprotésicas , Humanos , Artroplastia de Reemplazo de Cadera/efectos adversos , Fracturas Periprotésicas/etiología , Fracturas Periprotésicas/prevención & control , Fracturas Periprotésicas/cirugía , Estudios Retrospectivos , Diseño de Prótesis , Fracturas del Fémur/etiología , Fracturas del Fémur/prevención & control , Fracturas del Fémur/cirugía
3.
Life (Basel) ; 13(6)2023 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-37374148

RESUMEN

In this case report, we present a rare case of a female patient who developed pain and swelling after a total knee arthroplasty. An extensive diagnostic workup including serum and synovial testing to rule out infection was performed in addition to advanced imaging including an MRI of the knee, but it was only after an arthroscopic synovectomy that the diagnosis of secondary synovial chondromatosis was confirmed. The purpose of this case report is to highlight the occurrence of secondary synovial chondromatosis as a rare cause of pain and swelling after total knee arthroplasty, thereby assisting clinicians in providing prompt diagnosis, surgical treatment, and efficient recovery in the setting of secondary synovial chondromatosis after total knee arthroplasty.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA