Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Artif Organs ; 2024 Sep 20.
Artículo en Inglés | MEDLINE | ID: mdl-39301839

RESUMEN

BACKGROUND: Cold atmospheric plasma (CAP) therapy has been recognized as effective treatment option for reducing bacterial load in chronic wounds, such as adult ventricular assist device (VAD) driveline exit-site infections. Currently, there have been no reports on the safety and efficacy of CAP therapy for pediatric cannula infections and inflammations in paracorporeal pulsatile VADs. METHODS: The mechanical strength of Berlin Heart EXCOR cannulas were tested both before and after CAP treatment (SteriPlas, Adtec Healthcare Limited, UK) to prove material safety. A ring tensile test of 20 untreated and 20 CAP-treated (5 min) EXCOR cannulas (Ø12mm), assessed the force at the breaking point of the cannulas (Fmax), at 25% (F25%) and 50% (F50%) of the maximum displacement. Additionally, the scanning electron microscope (SEM) micrographs for both groups examined any surface changes. Finally, the case of a 13-year-old male EXCOR patient with cannula infections, treated with CAP over 100 days, is presented. RESULTS: The in vitro measurements revealed no statistically significant differences in mechanical strength between the control and CAP group for F25% (8.18 ± 0.36 N, vs. 8.02 ± 0.43 N, p = 0.21), F50% (16.87 ± 1.07 N vs. 16.38 ± 1.32 N, p = 0.21), and FMAX (44.55 ± 3.24 N vs. 42.83 ± 4.32 N, p = 0.16). No surface structure alterations were identified in the SEM micrographs. The patient's cannula exit-sites showed a visible improvement in DESTINE wound staging, reduction in bacterial load and inflammatory parameters after CAP treatment without any side effects. CONCLUSION: Overall, CAP therapy proved to be a safe and effective for treating EXCOR cannula exit-site wound healing disorders in one pediatric patient, but further studies should investigate this therapy in more detail.

2.
Artif Organs ; 2024 Aug 06.
Artículo en Inglés | MEDLINE | ID: mdl-39105573

RESUMEN

BACKGROUND: Left ventricular assist device (LVAD) malposition has been linked to hemocompatibility-related adverse events (HRAEs). This study aimed to identify preoperative anatomical landmarks and postoperative pump position, associated with HRAEs during LVAD support. METHODS: Pre- and postoperative chest X-ray measures (≤14 days pre-implantation, first postoperative standing, 6, 12, 18, and 24 months post-implantation) were analyzed for their association with HRAEs over 24 months in 33 HeartMate 3 (HM3) patients (15.2% female, age 66 (9.5) years). RESULTS: HM3 patients with any HRAE showed significantly lower preoperative distances between left ventricle and thoracic outline (dLVT) (25.3 ± 10.2 mm vs. 40.3 ± 15.5 mm, p = 0.004). A ROC-derived cutoff dLVT ≤ 29.2 mm provided 85.7% sensitivity and 72.2% specificity predicting any HRAE during HM3 support (76.2% (>29.2 mm) vs. 16.7% (≤29.2 mm) freedom from HRAE, p < 0.001) and significant differences in cardiothoracic ratio (0.58 ± 0.04 vs. 0.62 ± 0.04, p = 0.045). Postoperative X-rays indicated lower pump depths in patients with ischemic strokes (9.1 ± 16.2 mm vs. 38.0 ± 18.5 mm, p = 0.007), reduced freedom from any neurological event (pump depth ≤ 28.7 mm: 45.5% vs. 94.1%, p = 0.004), and a significant correlation between pump depth and inflow cannula angle (r = 0.66, p < 0.001). Longitudinal changes were observed in heart-pump width (F(4,60) = 5.61, p < 0.001). CONCLUSION: Preoperative X-ray markers are associated with postoperative HRAE occurrence. Applying this knowledge in clinical practice may enhance risk stratification, guide therapy optimization, and improve HM3 recipient management.

3.
Artif Organs ; 2024 Aug 06.
Artículo en Inglés | MEDLINE | ID: mdl-39105561

RESUMEN

BACKGROUND: Temporal trends of routinely obtained parameters may provide valuable information for predicting BSIs, but this association has not yet been established in LVAD patients. METHODS: This retrospective analysis included data from 347 consecutive recipients of three rotary LVAD types. Study endpoints included the incidence of BSI, the association of temporal trends of routinely obtained blood biomarkers with the development of BSIs, the incidence of BSIs, and survival on LVAD support. RESULTS: During follow-up, 47.8% (n = 166) of the patients developed BSI. In multivariate analyses, the development of BSI was a significant predictor of mortality (HR 5.78, 95% CI 4.08-8.19, p < 0.0001). In univariate analyses, after adjusting for potential confounders, albumin (SHR 0.94, 95% CI 0.91-0.97, p < 0.00010), creatinine (SHR 1.49, 95% CI 1.03-2.15, p = 0.033), and C-reactive protein (SHR 1.19, 95% CI 1.08-1.32, p = 0.0007) significantly predicted the development of BSIs during LVAD support. Notably, the strength of the association of parameter changes with the prediction of BSIs demonstrated a time-dependent correlation in the cases of albumin (p = 0.045) and creatinine (p = 0.003). CONCLUSION: Bloodstream infections are highly prevalent among LVAD recipients and are independent predictors of mortality. Temporal biomarker trends significantly predict the development of BSIs. These findings suggest opportunities for interventions aiming to reduce the incidence of BSIs.

4.
Artif Organs ; 46(6): 1149-1157, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34978722

RESUMEN

BACKGROUND: A relation between the left ventricular assist device inflow cannula (IC) malposition and pump thrombus has been reported. This study aimed to investigate if the pump position, derived from chest X-rays in HeartMate 3 (HM3) patients, correlates with neurological dysfunction (ND), ischemic stroke (IS), hemorrhagic stroke (HS) and survival. METHODS: This analysis was performed on routinely acquired X-rays of 42 patients implanted with a HM3 between 2014 and 2017. Device position was quantified in patients with and without ND from frontal and lateral X-rays characterizing the IC and pump in relation to spine, diaphragm or horizontal line. The primary end-point was freedom from stroke and survival one-year after HM3 implantation stratified by pump position. RESULTS: The analysis of X-rays, 33.5 (41.0) days postoperative, revealed a significant smaller IC angle of HM3 patients with ND versus no ND (0.1° ± 14.0° vs. 12.9° ± 10.1°, p = 0.005). Additionally, the IC angle in the frontal view, IS: 4.1 (20.9)° versus no IS: 13.8 (7.5)°, p = 0.004 was significantly smaller for HM3 patients with IS. Using receiver operating characteristics derived cut-off, IC angle <10° provided 75% sensitivity and 100% specificity (C-statistic = 0.85) for predicting IS. Stratified by IC angle, freedom from IS at 12 months was 100% (>10°) and 60% (<10°) respectively (p = 0.002). No significant differences were found in any end-point between patients with and without HS. One-year survival was significantly higher in patients with IC angle >10° versus <10° (100% vs. 71.8%, p = 0.012). CONCLUSIONS: IC malposition derived from standard chest X-rays serves as a risk factor for ND, IS and worse survival in HM3 patients.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Accidente Cerebrovascular , Trombosis , Cánula/efectos adversos , Insuficiencia Cardíaca/cirugía , Corazón Auxiliar/efectos adversos , Humanos , Estudios Retrospectivos , Factores de Riesgo , Accidente Cerebrovascular/complicaciones , Trombosis/etiología
5.
J Cell Mol Med ; 25(20): 9697-9709, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34562312

RESUMEN

Telocytes (TCs), a novel interstitial cell entity promoting tissue regeneration, have been described in various tissues. Their role in inter-cellular signalling and tissue remodelling has been reported in almost all human tissues. This study hypothesizes that TC also contributes to tissue remodelling and regeneration of the human thoracic aorta (HTA). The understanding of tissue homeostasis and regenerative potential of the HTA is of high clinical interest as it plays a crucial role in pathogenesis from aortic dilatation to lethal dissection. Therefore, we obtained twenty-five aortic specimens of heart donors during transplantation. The presence of TCs was detected in different layers of aortic tissue and characterized by immunofluorescence and transmission electron microscopy. Further, we cultivated and isolated TCs in highly differentiated form identified by positive staining for CD34 and c-kit. Aortic-derived TC was characterized by the expression of PDGFR-α, PDGFR-ß, CD29/integrin ß-1 and αSMA and the stem cell markers Nanog and KLF-4. Moreover, TC exosomes were isolated and characterized for soluble angiogenic factors by Western blot. CD34+ /c-kit+ TCs shed exosomes containing the soluble factors VEGF-A, KLF-4 and PDGF-A. In summary, TC occurs in the aortic wall. Correspondingly, exosomes, derived from aortic TCs, contain vasculogenesis-relevant proteins. Understanding the regulation of TC-mediated aortic remodelling may be a crucial step towards designing strategies to promote aortic repair and prevent adverse remodelling.


Asunto(s)
Aorta/citología , Exosomas/metabolismo , Expresión Génica , Telocitos/citología , Telocitos/metabolismo , Factor A de Crecimiento Endotelial Vascular/genética , Biomarcadores , Micropartículas Derivadas de Células/metabolismo , Micropartículas Derivadas de Células/ultraestructura , Exosomas/ultraestructura , Fibroblastos/metabolismo , Técnica del Anticuerpo Fluorescente , Humanos , Inmunohistoquímica , Inmunofenotipificación , Factor 4 Similar a Kruppel/genética , Factor 4 Similar a Kruppel/metabolismo , Miocitos del Músculo Liso/metabolismo , Telocitos/ultraestructura , Factor A de Crecimiento Endotelial Vascular/metabolismo
6.
Artif Organs ; 45(5): 464-472, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33052592

RESUMEN

Driveline infections (DLI) are common adverse events in left ventricular assist devices (LVADs), leading to severe complications and readmissions. The study aims to characterize risk factors for DLI readmission 2 years postimplant. This single-center study included 183 LVAD patients (43 HeartMate II [HMII], 29 HeartMate 3 [HM3], 111 HVAD) following hospital discharge between 2013 and 2017. Demographics, clinical parameters, and outcomes were retrospectively analyzed and 12.6% of patients were readmitted for DLI, 14.8% experienced DLI but were treated in the outpatient setting, and 72.7% had no DLI. Mean C-reactive protein (CRP), leukocytes and fibrinogen were higher in patients with DLI readmission (P < .02) than in outpatient DLI and patients without DLI, as early as 60 days before readmission. Freedom from DLI readmission was comparable for HMII and HVAD (98% vs. 87%; HR, 4.52; 95% CI, 0.58-35.02; P = .15) but significantly lower for HM3 (72%; HR, 10.82; 95% CI, 1.26-92.68; P = .03). DLI (HR, 1.001; 95% CI, 0.999-1.002; P = .16) or device type had no effect on mortality. DLI readmission remains a serious problem following LVAD implantation, where CRP, leukocytes, and fibrinogen might serve as risk factors already 60 days before. HM3 patients had a higher risk for DLI readmissions compared to HVAD or HMII, possibly because of device-specific driveline differences.


Asunto(s)
Insuficiencia Cardíaca/cirugía , Corazón Auxiliar/efectos adversos , Infecciones Relacionadas con Prótesis/epidemiología , Adulto , Anciano , Biomarcadores/sangre , Proteína C-Reactiva/análisis , Femenino , Fibrinógeno/análisis , Estudios de Seguimiento , Humanos , Recuento de Leucocitos , Masculino , Persona de Mediana Edad , Readmisión del Paciente/estadística & datos numéricos , Infecciones Relacionadas con Prótesis/sangre , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/terapia , Estudios Retrospectivos , Medición de Riesgo/métodos , Medición de Riesgo/estadística & datos numéricos , Factores de Riesgo
7.
J Card Surg ; 36(4): 1344-1351, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33547707

RESUMEN

BACKGROUND: The aim of this study was to evaluate the impact of the surgical approach on the postoperative outcome in patients who underwent left ventricular assist device (LVAD) implantation after having received veno-arterial extracorporeal life support (va-ECLS) using data from a European registry (ECLS-VAD). Five hundred and thirty-one patients were included. METHODS: A propensity score-adjusted outcome analysis was performed, resulting in 324 patients in the full sternotomy (FS) group and 39 in the less invasive surgery (LIS) group. RESULTS: The surgery lasted in median 236 min in the FS group versus 263 min in the LIS group (p = 0.289). The median chest tube output during the first 24 h was similar in both groups. Patients who underwent implantation with an FS required more blood products during the first 24 postoperative hours (median 16 vs. 12, p = 0.033). The incidence of revision due to bleeding was also higher (35.5 vs. 15.4%, p = 0.016). A temporary postoperative right ventricular assist device was necessary in 45.1 (FS) versus 23.1% (LIS) of patients, respectively (p = 0.067). No stroke occurred in the LIS group during the first 30 days after surgery (7.4% in the FS group). The incidence of stroke and of renal, hepatic, and respiratory failure during the follow-up was similar in both groups. The 30-day and one-year survival were similar in both groups. CONCLUSION: LIS for implantation of a durable LVAD in patients on va-ECLS implanted for cardiogenic shock is associated with less revision due to bleeding, less administration of blood products and absence of perioperative stroke, with no impact on survival.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Insuficiencia Cardíaca , Corazón Auxiliar , Insuficiencia Cardíaca/cirugía , Humanos , Implantación de Prótesis , Estudios Retrospectivos , Resultado del Tratamiento
8.
Medicina (Kaunas) ; 58(1)2021 Dec 28.
Artículo en Inglés | MEDLINE | ID: mdl-35056351

RESUMEN

Background and objectives: Extracorporeal life support (ECLS) is a widely accepted and effective strategy for use in patients presenting with refractory cardiogenic shock. Implantation in awake and non-intubated patients allows for optimized evaluation of further therapy options while avoiding potential side effects associated with the need for sedation and intubation. The aim of the study was the assessment of safety and feasibility of awake ECLS implementation and of outcomes in patients treated with this concept. Materials and Methods: We retrospectively reviewed the concept of awake ECLS implantation in 16 consecutive patients (mean age 58 ± 8 years; male: 88%; ischemic cardiomyopathy: 50%) from 02/2017 to 01/2021. Study endpoints were survival to weaning or bridging to durable support or organ replacement and development of end-organ function and hemodynamic parameters on ECLS. Results: Fourteen patients (88%) were able to be successfully transitioned to definite therapy options. ECLS support stabilized end-organ function, led to a decrease in mean lactate levels (5.3 ± 3.7 mmol/L at baseline to 1.9 ± 1.3 mmol/L 12 h after ECLS start; p = 0.01) and improved hemodynamics (median central venous pressure 20 ± 5 mmHg vs. 10 ± 2 mmHg, p = 0.001) over a median duration of two days (1-8 days IQR). Two patients (13%) died on ECLS support due to multi-organ dysfunction syndrome. Survival to discharge of initially successfully bridged or weaned patients was 64%. Conclusions: Awake ECLS implantation is feasible and safe with the key advantage of omitting or delaying general anesthesia and intubation, with their associated risks in cardiogenic-shock patients, facilitating further decision making.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Choque Cardiogénico , Anciano , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Choque Cardiogénico/terapia , Resultado del Tratamiento , Vigilia
9.
Artif Organs ; 44(7): E251-E262, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31945201

RESUMEN

Suction of the left ventricle can lead to potentially life-threatening events in left ventricular assist device (LVAD) patients. With the resolution of currently available clinical LVAD monitoring healthcare professionals are unable to evaluate patients' suction occurrences in detail. This study investigates occurrences and durations of suction events and their associations with tachycardia in stable outpatients. Continuous high-resolution LVAD data from HVAD patients were analyzed in the early outpatient period for 15 days. A validated suction detection from LVAD signals was used. Suction events were evaluated as suction rates, bursts of consecutive suction beats, and clusters of suction beats. The occurrence of tachycardia was analyzed before, during, and after suction clusters. Furthermore, blood work, implant strategy, LVAD speed setting, inflow cannula position, left ventricular diameters, and adverse events were evaluated in these patients. LVAD data of 10 patients was analyzed starting at 78 ± 22 postoperative days. Individuals' highest suction rates per hour resulted in a median of 11% (range 3%-61%). Bursts categorized as consecutive suction beats with n = 2, n = 3-5, n = 6-15, and n > 15 beats were homogenously distributed with 10.3 ± 0.8% among all suction beats. Larger suction bursts were followed by shorter suction-free periods. Tachycardia during suction occurred in 12% of all suction clusters. Significant differences in clinical parameters between individuals with high and low suction rates were only observed in left ventricular end-diastolic and end-systolic diameters (P < .02). Continuous high-resolution LVAD monitoring sheds light on outpatient suction occurrences. Interindividual and intraindividual characteristics of longitudinal suction rates were observed. Longer suction clusters have higher probabilities of tachycardia within the cluster and more severe types of suction waveforms. This work shows the necessity of improved LVAD monitoring and the implementation of an LVAD speed control to reduce suction rates and their concomitant burden on the cardiovascular system.


Asunto(s)
Insuficiencia Cardíaca/cirugía , Ventrículos Cardíacos/fisiopatología , Corazón Auxiliar/efectos adversos , Monitorización Hemodinámica , Complicaciones Posoperatorias/diagnóstico , Anciano , Ecocardiografía Doppler en Color , Ecocardiografía Doppler de Pulso , Femenino , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Modelos Cardiovasculares , Complicaciones Posoperatorias/fisiopatología , Complicaciones Posoperatorias/prevención & control , Succión , Función Ventricular Izquierda/fisiología
10.
Artif Organs ; 42(7): 695-699, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30117586

RESUMEN

Literature on driving capacities of ventricular assist device patients is rare and driving restrictions differ from center to center. Currently, no guidelines exist on whether and when left ventricular assist device (LVAD) patients are allowed to begin driving cars after device implantation. In this study, we assess the driving abilities of patients after LVAD implantation. Three hundred and ninety LVAD patients have been surveyed in a worldwide, multicenter study. The single survey followed a multi-method design, including online, phone, and face-to-face interviews. Out of 390 patients, 72% are still driving and 28% did not continue driving after LVAD implantation. Reasons for discontinuation were capability (24%), insecurity (17%), and disapproval by family members (9%) or doctors (5%). Ninety percent of the patients describe their ability to drive as perfect or adequate. Sixty-nine percent state that they are not restricted in their general driving capacity. Forty-nine percent report not to be restricted in agility to drive by the device equipment. The majority of patients have not been involved in car accidents or major complications (94%). Eight accidents were reported (3%). Out of those, all were minor collisions. No patient reported the occurrence of a fatal accident or casualties. LVAD alarms did occur in six incidents (2%) with the majority being low battery alarms. The results of this study suggest that driving with a left ventricular assist device is safe for stable patients and driving can be resumed 3 months after LVAD implantation after careful patient assessment.


Asunto(s)
Conducción de Automóvil , Corazón Auxiliar , Implantación de Prótesis , Accidentes de Tránsito , Adulto , Anciano , Ventrículos Cardíacos/cirugía , Corazón Auxiliar/efectos adversos , Humanos , Persona de Mediana Edad , Implantación de Prótesis/efectos adversos , Calidad de Vida , Resultado del Tratamiento , Adulto Joven
11.
Artif Organs ; 42(10): 961-969, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-29799135

RESUMEN

Ventricular assist devices (VADs) are an established therapeutic option for patients with chronic heart failure. Continuous monitoring of VAD parameters and their adherence to guidelines are crucial to detect problems in an early stage to optimize outcomes. A telephone intervention algorithm for VAD outpatients was developed, clinically implemented and evaluated. During the phone calls, a structured inquiry of pump parameters, alarms, blood pressure, INR, body weight and temperature, exit-site status and heart failure symptoms was performed and electronically categorized by an algorithm into 5 levels of severity. VAD outpatient outcomes without (n = 71) and with bi-weekly telephone interviews in their usual care (n = 25) were conducted using proportional hazard Cox regression, with risk adjustment based on a propensity score model computed from demographics and risk factors. From February 2015 through October 2017, 25 patients (n = 3 HeartMate II, n = 4 HeartMate 3 and n = 18 HeartWare HVAD) underwent 637 telephone interventions. In 57.5% of the calls no problems were identified, 3.9% were recalled on the next day because of alarms. In 26.5% (n = 169), the VAD Coordinator had to refer to the physician due to elevated blood pressure (n = 125, >85 mm Hg), INR < 2.0 or > 4.0 (n = 24) or edema (n = 10), 11.9% of the calls led to a follow-up because of equipment or exit-site problems. Propensity-adjusted 2-year survival (89% vs. 57%, P = 0.027) was significantly higher for the telephone intervention group. Continuous, standardized communication with VAD outpatients is important for early detection of upcoming problems and leads to significantly improved survival.


Asunto(s)
Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Anciano , Algoritmos , Femenino , Insuficiencia Cardíaca/cirugía , Humanos , Masculino , Persona de Mediana Edad , Pacientes Ambulatorios , Puntaje de Propensión , Modelos de Riesgos Proporcionales , Estudios Retrospectivos , Encuestas y Cuestionarios , Teléfono , Resultado del Tratamiento
12.
J Clin Med ; 13(5)2024 Feb 20.
Artículo en Inglés | MEDLINE | ID: mdl-38592041

RESUMEN

Background: Fulminant myocarditis (FM) constitutes a severe and life-threatening form of acute cardiac injury associated with cardiogenic shock. The condition is characterised by rapidly progressing myocardial inflammation, leading to significant impairment of cardiac function. Due to the acute and severe nature of the disease, affected patients require urgent medical attention to mitigate adverse outcomes. Besides symptom-oriented treatment in specialised intensive care units (ICUs), the necessity for temporary mechanical cardiac support (MCS) may arise. Numerous patients depend on these treatment methods as a bridge to recovery or heart transplantation, while, in certain situations, permanent MCS systems can also be utilised as a long-term treatment option. Methods: This review consolidates the existing evidence concerning the currently available MCS options. Notably, data on venoarterial extracorporeal membrane oxygenation (VA-ECMO), microaxial flow pump, and ventricular assist device (VAD) implantation are highlighted within the landscape of FM. Results: Indications for the use of MCS, strategies for ventricular unloading, and suggested weaning approaches are assessed and systematically reviewed. Conclusions: Besides general recommendations, emphasis is put on the differences in underlying pathomechanisms in FM. Focusing on specific aetiologies, such as lymphocytic-, giant cell-, eosinophilic-, and COVID-19-associated myocarditis, this review delineates the indications and efficacy of MCS strategies in this context.

13.
J Heart Lung Transplant ; 43(2): 251-260, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37769887

RESUMEN

PURPOSE: The HeartMate 3 (HM3) left ventricular assist device (LVAD) has demonstrated excellent clinical outcomes; however, pump speed optimization is challenging with the available HM3 monitoring. Therefore, this study reports on clinical HM3 parameters collected with a noninvasive HM3 monitoring system (HM3 Snoopy) during echocardiographic speed ramp tests and Valsalva maneuvers. METHODS: In this prospective, single-center study, the HM3 data communication between the controller and pump was recorded with a novel data acquisition system. Twelve pump parameters sampled every second (1 Hz) and clinical assessments (echocardiography, electrocardiogram (ECG), and blood pressure measurement) during speed ramp tests were analyzed using Pearson's correlation (r, median [IQR]). The cause for the occurrence of pulsatility index (PI)-events during ramp speed tests and valsalva maneuvers was investigated. RESULTS: In 24 patients (age: 58.9 ± 8.8 years, body mass index: 28.1 ± 5.1 kg/m2, female: 20.8%), 35 speed ramp tests were performed with speed changes in the range of ±1000 rpm from a baseline speed of 5443 ± 244 rpm. Eight HM3 pump parameters from estimated flow, motor current, and LVAD speed together with blood pressure showed positive collinearities (r = 0.9 [0.1]). Negative collinearities were observed for pump flow pulsatility, pulsatility index, rotor noise, and left ventricular diameters (r = -0.8 [0.1]), whereas rotor displacement and heartrate showed absence of collinearities (r = -0.1 [0.08]). CONCLUSIONS: In this study, the HM3 Snoopy was successfully used to acquire more parameters from the HM3 at a higher sampling rate. Analysis of HM3 per-second data provide additional clinical diagnostic information on heart-pump interactions and cause of PI-events.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Humanos , Femenino , Persona de Mediana Edad , Anciano , Estudios Prospectivos , Maniobra de Valsalva , Ecocardiografía , Corazón Auxiliar/efectos adversos
14.
Eur J Cardiothorac Surg ; 63(4)2023 04 03.
Artículo en Inglés | MEDLINE | ID: mdl-36825836

RESUMEN

OBJECTIVES: Haemorrhagic and thrombotic complications are known obstacles in extracorporeal life support (ECLS), and patients requiring post-cardiotomy (PC)-ECLS are particularly prone. The objective of this study was to characterize the incidence, type and clinical relevance of bleeding and thrombotic events in patients on PC-ECLS. METHODS: A total of 504 patients receiving PC-ECLS between 2000 and 2021 at a single centre were included in a retrospective analysis. Incidence and type of haemorrhagic and thrombotic complications in patients on PC-ECLS were assessed. Overall survival was compared, and perioperative risk factors for bleeding and thrombotic events were assessed by binary logistic regression. RESULTS: Of the 504 patients requiring PC-ECLS, 196 patients (38.9%) had 235 bleeding events [surgical site: n = 135 (26.8%); cannulation site: n = 68(13.4%); requiring surgical revision: n = 39 (7.7%); cannulation site change: n = 17 (3.4%); fatal cannulation site bleeding: n = 4(0.8%); intracranial haemorrhage: n = 11 (2.1%); gastrointestinal haemorrhage: n = 8 (1.6%); pulmonary haemorrhage: n = 8 (1.6%); and intra-abdominal/retroperitoneal haemorrhage: n = 5 (1%)]. Overall mortality was higher in patients with major bleeding complications than in patients without bleeding complications (P < 0.0001).A total of 74 patients (14.7%) had 84 thrombotic events [ischaemic stroke, n = 39 (7.7%); cannula/circuit thrombosis, n = 26 (5.2%); peripheral embolism, n = 11 (2.2%); device exchange for haemolysis, n = 8 (1.6%)]. Another 246 patients (48.8%) had at least 1 haemocompatibility-related adverse event. Preoperative dual antiplatelet therapy [adjusted odds ratio (OR): 1.83, 95% confidence interval (CI): 1.063-3.137] and ECLS duration (adjusted OR: 1.14, 95% CI: 1.086-1.197) were identified as independent risk factors for haemorrhage. Prior stroke/transient ischaemic attack (adjusted OR: 1.91, 95% CI: 1.08-3.83) and ECLS duration (adjusted OR: 1.09, 95% CI: 1.04-1.15) were identified as risk factors for thrombotic events. CONCLUSIONS: Bleeding complications in patients on ECLS are common and significantly impair survival. Nearly half of the patients were affected by any haemocompatibility-related event.


Asunto(s)
Isquemia Encefálica , Oxigenación por Membrana Extracorpórea , Accidente Cerebrovascular , Trombosis , Humanos , Oxigenación por Membrana Extracorpórea/efectos adversos , Estudios Retrospectivos , Isquemia Encefálica/etiología , Accidente Cerebrovascular/etiología , Hemorragia/epidemiología , Hemorragia/etiología , Trombosis/epidemiología , Trombosis/etiología
15.
ASAIO J ; 69(6): 595-601, 2023 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-36821448

RESUMEN

VISUAL ABSTRACT: of key results. INR, international normalized ratio; TTR, time in therapeutic range; PTR, percentage of tests in range; HRAE, hemocompatibility-related adverse event; FFUV, first follow-up visit; GIB, gastrointestinal bleeding; HR, hazard ratio.http://links.lww.com/ASAIO/A961.


Asunto(s)
Corazón Auxiliar , Warfarina , Humanos , Anticoagulantes/efectos adversos , Coagulación Sanguínea , Relación Normalizada Internacional/métodos , Fenprocumón/efectos adversos , Warfarina/efectos adversos
16.
J Cardiovasc Surg (Torino) ; 64(1): 121-129, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36763071

RESUMEN

BACKGROUND: Total artificial heart (TAH) implantation is a rarely performed procedure. Contrarily, left ventricular assist device (VAD) implantation is rather common in many centers. As transplantation is quantitatively limited cardiac replacement with artificial hearts is a viable alternative in the treatment of severe biventricular heart failure. An alternative to TAH is the implantation of two VADs in a TAH configuration. We hereby present the first multi-center study on 3-months outcomes of patients treated by cardiectomy and placement of two HeartMate 3s in a TAH configuration. METHODS: We retrospectively investigated a cohort of 15 patients that underwent HM3-TAH-implantation at three international institutions. Follow-up was 3 months after implantation. Baseline, intra- and postoperative parameters as well as survival data and adverse events were collected. RESULTS: A total of 1089 days on HM3-TAH were observed. Thirty-day survival after HM3-TAH implantation was 53% (8/15) and three month survival was 40% (6/15). The longest duration on device was 274 days. Causes of death were multi-organ failure, sepsis, and neurological adverse events. No technical complications were documented. Two patients remained on the device. Four patients (26%) were successfully bridged to transplantation. CONCLUSIONS: The implantation of two HeartMate 3s in a TAH configuration is a last resort and off-label concept in cases of extreme biventricular heart failure. In a diligently selected patient cohort, HM3-TAH implantation is a feasible method to increase the chance of survival in a severely ill patient cohort and successfully bridge patients to heart transplantation that would otherwise have died.


Asunto(s)
Insuficiencia Cardíaca , Trasplante de Corazón , Corazón Artificial , Corazón Auxiliar , Humanos , Corazón Auxiliar/efectos adversos , Estudios Retrospectivos , Corazón Artificial/efectos adversos , Insuficiencia Cardíaca/cirugía
17.
J Heart Lung Transplant ; 42(4): 466-477, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36682893

RESUMEN

BACKGROUND: Despite design improvements in left ventricular assist devices (LVADs) over the past decade, limitations of external, wearable VAD components affect patient quality of life and safety. The aim of this study was to describe both user experience and human factor issues of 2 contemporary LVADs. METHODS: This single-center, cross-sectional study included LVAD outpatients who were at least 3 months after implantation. Before developing the 16-item survey, a systematic literature review and 2-round Delphi method involving 9 VAD clinicians were used to select items in 6 domains: power supply, emergency situations, wearability, mobility, and freedom to travel, user modifications, lifestyle, and home adaptations. RESULTS: Fifty-eight patients (61.6 ± 11.6 years, 13.8% female, HeartMate 3 (HM3)/HVAD: n = 39/19) completed the one-time survey after median of 853 days on device: 10.3% reported problems changing power supply, 12.7% unintentional driveline disconnection (HM3: 5.6% vs HVAD: 26.3%, p = 0.041). Against the recommendation 74.1% sleep with battery-support (HM3: 88.9% vs HVAD: 44.4%, p = 0.001). About 65.3% criticized the carry bag weight/size (HM3: 71.4% vs HVAD: 50.0%, p = 0.035), thus 24.1% wear an own carrying-system, 42.1% modified their wearables, 38.9% their clothing, and 65.3% their home to cope with life on LVAD support. Mobility is reduced due to limited wearability: 18.9% went abroad (only 3.7% by plane) and 40.0% use less public transport than before implantation (the older the less: r = -0.37, p = 0.013). CONCLUSIONS: HVAD and HM3 wearables still show a variety of human factors issues and potential for improved user experience. User-centered design and incorporation of patient feedback may increase user satisfaction, and patient safety.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Dispositivos Electrónicos Vestibles , Femenino , Humanos , Masculino , Estudios Transversales , Insuficiencia Cardíaca/cirugía , Calidad de Vida , Estudios Retrospectivos , Persona de Mediana Edad , Anciano , Factores de Riesgo
18.
ESC Heart Fail ; 10(3): 1656-1665, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36798028

RESUMEN

AIMS: Since the withdrawal of HeartWare (HVAD) from the global market, there is an ongoing discussion if and which patients require prophylactically exchange for a HeartMate 3 (HM3). Therefore, it is important to study outcome differences between HVAD and HM3 patients. Because centres differ in patient selection and standard of care, we performed a propensity score (PS)-based study including centres that implanted both devices and aimed to identify which HVAD patients are at highest risk. METHODS AND RESULTS: We performed an international multi-centre study (n = 1021) including centres that implanted HVAD and HM3. PS-matching was performed using clinical variables and the implanting centre. Survival and complications were compared. As a sensitivity analysis, PS-adjusted Cox regression was performed. Landmark analysis with conditional survival >2 years was conducted to evaluate long-term survival differences. To identify which HVAD patients may benefit from a HM3 upgrade, Cox regression using pre-operative variables and their interaction with device type was performed. Survival was significantly better for HM3 patients (P < 0.01) in 458 matched patients, with a median follow-up of 23 months. Within the matched cohort, HM3 patients had a median age of 58 years, and 83% were male, 80% of the HVAD patients were male, with a median age of 59 years. PS-adjusted Cox regression confirmed a significantly better survival for HM3 patients when compared with HVAD, with a HR of 1.46 (95% confidence interval 1.14-1.85, P < 0.01). Pump thrombosis (P < 0.01) and ischaemic stroke (P < 0.01) occurred less in HM3 patients. No difference was found for haemorrhagic stroke, right heart failure, driveline infection, and major bleeding. Landmark-analysis confirmed a significant difference in conditional survival >2 years after implantation (P = 0.03). None of the pre-operative variable interactions in the Cox regression were significant. CONCLUSIONS: HM3 patients have a significantly better survival and a lower incidence of ischaemic strokes and pump thrombosis than HVAD patients. This survival difference persisted after 2 years of implantation. Additional research using post-operative variables is warranted to identify which HVAD patients need an upgrade to HM3 or expedited transplantation.


Asunto(s)
Isquemia Encefálica , Insuficiencia Cardíaca , Corazón Auxiliar , Accidente Cerebrovascular , Trombosis , Humanos , Masculino , Persona de Mediana Edad , Femenino , Isquemia Encefálica/complicaciones , Accidente Cerebrovascular/epidemiología , Corazón Auxiliar/efectos adversos , Insuficiencia Cardíaca/cirugía , Insuficiencia Cardíaca/etiología , Trombosis/epidemiología , Trombosis/etiología
19.
Artículo en Inglés | MEDLINE | ID: mdl-37689237

RESUMEN

OBJECTIVES: The Durable Mechanical Circulatory Support System After Extracorporeal Life Support registry is a multicenter registry of patients who were bridged from extracorporeal life support to a durable mechanical circulatory support system. Although numerous studies have highlighted the favorable outcomes after implantation of the HeartMate 3 (Abbott), the objective of our study is to examine the outcomes of patients who received HeartMate 3 support after extracorporeal life support. METHODS: Data of patients undergoing HeartMate 3 implantation from January 2016 to April 2022 at 14 centers were collected and evaluated. Inclusion criteria were patients with extracorporeal life support before HeartMate 3 implantation. The outcome was reported and compared with patients receiving other types of pumps. RESULTS: A total of 337 patients were bridged to durable mechanical circulatory support system after extracorporeal life support in the study period. Of those patients, 140 were supported with the HeartMate 3. The other types of pumps included 170 HeartWare HVADs (Medtronic) (86%), 14 HeartMate II devices (7%), and 13 (7%) other pumps (7%). Major postoperative complications included right heart failure requiring temporary right ventricular assist device in 60 patients (47%). Significantly lower postoperative stroke (16% vs 28%, P = .01) and pump thrombosis (3% vs 8%, P = .02) rates were observed in the patients receiving the HeartMate 3. The 30-day, 1-year, and 3-year survivals in patients receiving the HeartMate 3 were 87%, 73%, and 65%, respectively. CONCLUSIONS: In this critically ill patient population, the survivals of patients who were transitioned to the HeartMate 3 are deemed acceptable and superior to those observed when extracorporeal life support was bridged to other types of durable mechanical circulatory support systems.

20.
ASAIO J ; 69(2): 145-150, 2023 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-35438667

RESUMEN

Stroke is one of the leading complications following durable mechanical circulatory support (MCS) implantation. The aim of this multicenter study was to investigate stroke complications in patients requiring durable MCS following extracorporeal life support (ECLS). Data of 11 high volume MCS centers were collected and evaluated to identify patients who underwent durable MCS implantation after ECLS support between January 2010 and August 2018. The primary outcome was stroke following durable MCS implantation. Univariate and multivariate logistic regression analyses were performed to determine predictors of stroke. Overall, 531 patients met the inclusion criteria. Only patients who were supported with continuous flow pumps were included in this study accounting for 495 patients (median age 54 years old [interquartile range 47-60]). A total of 136 patients (27%) developed postoperative stroke on device during the follow-up (48% ischemic and 52% hemorrhagic) after a median durable MCS support of 320 [32-1,000] days, accounting for 0.17 events per patient-year. Of 133 patients with known date of stroke, a total of 47 (10%) developed stroke during the first 30 days (64% ischemic and 36% hemorrhagic), and 86 patients developed stroke after 30 days (38% ischemic and 62% hemorrhagic) of durable MCS support (late stroke). Survival rate was significantly lower in patients with hemorrhagic stroke ( p = 0.00091). Stroke appears to be a common complication in patients transitioned to durable MCS support after ECLS. Hemorrhagic stroke is a more common type of late stroke and is associated with inferior outcomes.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Insuficiencia Cardíaca , Corazón Auxiliar , Accidente Cerebrovascular Hemorrágico , Humanos , Persona de Mediana Edad , Oxigenación por Membrana Extracorpórea/efectos adversos , Accidente Cerebrovascular Hemorrágico/etiología , Corazón Auxiliar/efectos adversos , Estudios Retrospectivos , Tasa de Supervivencia , Resultado del Tratamiento , Insuficiencia Cardíaca/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA