Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Eur Radiol ; 32(12): 8597-8607, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35612663

RESUMEN

OBJECTIVES: 4D flow MRI enables quantitative assessment of helical flow. We sought to generate normal values and elucidate changes of helical flow (duration, volume, length, velocities and rotational direction) and flow jet (displacement, flow angle) as well as wall shear stress (WSS). METHODS: We assessed the temporal helical existence (THEX), maximum helical volume (HVmax), accumulated helical volume (HVacc), accumulated helical volume length (HVLacc), maximum forward velocity (maxVfor), maximum circumferential velocity (maxVcirc), rotational direction (RD) and maximum wall shear stress (WSS) as reported elsewhere using the software tool Bloodline in 86 healthy volunteers (46 females, mean age 41 ± 13 years). RESULTS: WSS decreased by 42.1% and maxVfor by 55.7% across age. There was no link between age and gender regarding the other parameters. CONCLUSION: This study provides age-dependent normal values regarding WSS and maxVfor and age- and gender-independent normal values regarding THEX, HVmax, HVacc, HVLacc, RD and maxVcirc. KEY POINTS: • 4D flow provides numerous new parameters; therefore, normal values are mandatory. • Wall shear stress decreases over age. • Maximum helical forward velocity decreases over age.


Asunto(s)
Aorta , Hemodinámica , Femenino , Humanos , Adulto , Persona de Mediana Edad , Velocidad del Flujo Sanguíneo , Valores de Referencia , Voluntarios Sanos , Estrés Mecánico
2.
Rofo ; 196(3): 273-282, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37944940

RESUMEN

PURPOSE: To utilize 4 D flow MRI to acquire normal values of "conventional 2 D flow MRI parameters" in healthy volunteers in order to replace multiple single 2 D flow measurements with a single 4 D flow acquisition. MATERIALS AND METHODS: A kt-GRAPPA accelerated 4 D flow sequence was used. Flow volumes were assessed by forward (FFV), backward (BFV), and net flow volumes (NFV) [ml/heartbeat] and flow velocities by axial (VAX) and absolute velocity (VABS) [m/s] in 116 volunteers (58 females, 43 ±â€Š13 years). The aortic regurgitant fraction (RF) was calculated. RESULTS: The sex-neutral mean FFV, BFV, NFV, and RF in the ascending aorta were 93.5 ±â€Š14.8, 3.6 ±â€Š2.8, 89.9 ±â€Š0.6 ml/heartbeat, and 3.9 ±â€Š2.9 %, respectively. Significantly higher values were seen in males regarding FFV, BFV, NFV and RF, but there was no sex dependency regarding VAX and VABS. The mean maximum VAX was lower (1.01 ±â€Š0.31 m/s) than VABS (1.23 ±â€Š0.35 m/s). We were able to determine normal ranges for all intended parameters. CONCLUSION: This study provides quantitative 4 D flow-derived thoracic aortic normal values of 2 D flow parameters in healthy volunteers. FFV, BFV, NFV, and VAX did not differ significantly from single 2 D flow acquisitions and could therefore replace time-consuming multiple single 2 D flow acquisitions. VABS should not be used interchangeably. KEY POINTS: · 4 D flow MRI can be used to replace 2 D flow MRI measurements.. · The parameter absolute velocities can be assessed by 4 D flow MRI.. · There are sex-dependent differences regarding forward, backward, net aortic blood flow and the aortic valve regurgitant fraction..


Asunto(s)
Aorta , Imagen por Resonancia Magnética , Masculino , Femenino , Humanos , Valores de Referencia , Voluntarios Sanos , Velocidad del Flujo Sanguíneo/fisiología , Aorta/diagnóstico por imagen , Imagenología Tridimensional , Reproducibilidad de los Resultados , Aorta Torácica/diagnóstico por imagen
3.
Quant Imaging Med Surg ; 13(12): 7973-7986, 2023 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-38106267

RESUMEN

Background: The rotational direction (RD) of helical blood flow can be classified as either a clockwise (RD+) or counter-clockwise (RD-) flow. We hypothesized that this simple classification might not be sufficient for analysis in vivo and a simultaneous existence of RD+/- may occur. We utilized volumetric velocity-sensitive cardiovascular magnetic resonance imaging (4D flow MRI) to analyze rotational blood flow in the thoracic aorta. Methods: Forty volunteers (22 females; mean age, 41±16 years) and seventeen patients with bicuspid aortic valves (BAVs) (9 females; mean age, 42±14 years) were prospectively included. The RDs and the calculation of the rotating blood volumes (RBVs) in the thoracic aorta were performed using a pathline-projection strategy. Results: We could confirm a mainly clockwise RD in the ascending, descending aorta and in the aortic arch. Furthermore, we found a simultaneous existence of RD+/RD-. The RD+/--volume in the ascending aorta was significantly higher in BAV patients, the mean RD+/RD- percentage was approximately 80%/20% vs. 60%/40% in volunteers (P<0.01). The maximum RBV always occurred during systole. There was significantly more clockwise than counter-clockwise rotational flow in the ascending aorta (P<0.01) and the aortic arch (P<0.01), but no significant differences in the descending aorta (P=0.48). Conclusions: A simultaneous occurrence of RD+/RD- indicates that a simple categorization in either of both is insufficient to describe blood flow in vivo. Rotational flow in the ascending aorta and in the aortic arch differs significantly from flow in the descending aorta. BAV patients show significantly more clockwise rotating volume in the ascending aorta compared to healthy volunteers.

4.
Psychother Psychosom Med Psychol ; 62(8): 310-8, 2012 Aug.
Artículo en Alemán | MEDLINE | ID: mdl-22869531

RESUMEN

Homosexual parents as well as gay and lesbian individuals wanting children are increasingly a topic of public discourse. To estimate the importance of parenting for this group, 1 289 non-heterosexual individuals were examined by means of an anonymous online survey. Their answers were compared to 1 022 heterosexual participants of a representative control group. The respondents were questioned concerning their motives for desiring children, the external factors influencing this desire and their ideal number of children. 80% of the non-heterosexual respondents and 49% of the control group indicated that they have no children. In both groups emotional motives were reported to have far greater influence on their parenting desire than social recognition or personal and financial constraints. 85% of the non-heterosexual respondents and 60% of the control group have fewer children than they would like to have. Both groups considered work and their financial situation as the most important external factors influencing the realization of their desire to have children.


Asunto(s)
Identidad de Género , Padres/psicología , Conducta Sexual/psicología , Adolescente , Adulto , Anciano , Familia , Femenino , Heterosexualidad , Homosexualidad , Humanos , Masculino , Persona de Mediana Edad , Responsabilidad Parental , Factores Socioeconómicos , Adulto Joven
5.
Sci Rep ; 10(1): 2949, 2020 02 19.
Artículo en Inglés | MEDLINE | ID: mdl-32076060

RESUMEN

4D flow MRI enables quantitative assessment of helical flow. Current methods are susceptible to noise. To evaluate helical flow patterns in healthy volunteers and patients with bicuspid aortic valves (BAV) at 1.5 T and 3 T using pressure-based helix-extraction in 4D flow MRI. Two intraindividual 4D flow MRI examinations were performed at 1.5 T and 3 T in ten healthy volunteers (5 females, 32 ± 3 years) and 2 patients with BAV using different acceleration techniques (kt-GRAPPA and centra). Several new quantitative parameters for the evaluation of volumes [ml], lengths [mm] as well as temporal parameters [ms] of helical flow were introduced and analyzed using the software tool Bloodline. We found good correlations between measurements in volunteers at 1.5 T and 3 T regarding helical flow volumes (R = 0.98) and temporal existence (R = 0.99) of helices in the ascending aorta. Furthermore, we found significantly larger (11.7 vs. 77.6 ml) and longer lasting (317 vs. 769 ms) helices in patients with BAV than in volunteers. The assessed parameters do not depend on the magnetic field strength used for the acquisition. The technique of pressure-based extraction of 4D flow MRI pattern is suitable for differentiation of normal and pathological flow.


Asunto(s)
Aorta/diagnóstico por imagen , Imagen por Resonancia Magnética , Flujo Sanguíneo Regional/fisiología , Adulto , Automatización , Femenino , Humanos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA