Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Eur J Nucl Med Mol Imaging ; 51(10): 3040-3054, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38900308

RESUMEN

To meet the growing demand for intraoperative molecular imaging, the development of compatible imaging agents plays a crucial role. Given the unique requirements of surgical applications compared to diagnostics and therapy, maximizing translational potential necessitates distinctive imaging agent designs. For effective surgical guidance, exogenous signatures are essential and are achievable through a diverse range of imaging labels such as (radio)isotopes, fluorescent dyes, or combinations thereof. To achieve optimal in vivo utility a balanced molecular design of the tracer as a whole is required, which ensures a harmonious effect of the imaging label with the affinity and specificity (e.g., pharmacokinetics) of a pharmacophore/targeting moiety. This review outlines common design strategies and the effects of refinements in the molecular imaging agent design on the agent's pharmacological profile. This includes the optimization of affinity, pharmacokinetics (including serum binding and target mediated background), biological clearance route, the achievable signal intensity, and the effect of dosing hereon.


Asunto(s)
Cirugía Asistida por Computador , Humanos , Cirugía Asistida por Computador/métodos , Imagen Molecular/métodos , Animales , Diseño de Fármacos
2.
Eur J Nucl Med Mol Imaging ; 51(10): 3026-3039, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38233609

RESUMEN

PURPOSE: The aim of this review is to give an overview of the current status of molecular image-guided surgery in gynaecological malignancies, from both clinical and technological points of view. METHODS: A narrative approach was taken to describe the relevant literature, focusing on clinical applications of molecular image-guided surgery in gynaecology, preoperative imaging as surgical roadmap, and intraoperative devices. RESULTS: The most common clinical application in gynaecology is sentinel node biopsy (SNB). Other promising approaches are receptor-target modalities and occult lesion localisation. Preoperative SPECT/CT and PET/CT permit a roadmap for adequate surgical planning. Intraoperative detection modalities span from 1D probes to 2D portable cameras and 3D freehand imaging. CONCLUSION: After successful application of radio-guided SNB and SPECT, innovation is leaning towards hybrid modalities, such as hybrid tracer and fusion of imaging approaches including SPECT/CT and PET/CT. Robotic surgery, as well as augmented reality and virtual reality techniques, is leading to application of these innovative technologies to the clinical setting, guiding surgeons towards a precise, personalised, and minimally invasive approach.


Asunto(s)
Neoplasias de los Genitales Femeninos , Imagen Molecular , Cirugía Asistida por Computador , Humanos , Femenino , Neoplasias de los Genitales Femeninos/diagnóstico por imagen , Neoplasias de los Genitales Femeninos/cirugía , Cirugía Asistida por Computador/métodos , Imagen Molecular/métodos
3.
Eur J Nucl Med Mol Imaging ; 51(7): 2085-2097, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38329507

RESUMEN

PURPOSE: The aim of this study was to investigate the biodistribution of (super-)selective trans-arterial radioembolization (TARE) with holmium-166 microspheres (166Ho-MS), when administered as adjuvant therapy after RFA of HCC 2-5 cm. The objective was to establish a treatment volume absorbed dose that results in an absorbed dose of ≥ 120 Gy on the hyperemic zone around the ablation necrosis (i.e., target volume). METHODS: In this multicenter, prospective dose-escalation study in BCLC early stage HCC patients with lesions 2-5 cm, RFA was followed by (super-)selective infusion of 166Ho-MS on day 5-10 after RFA. Dose distribution within the treatment volume was based on SPECT-CT. Cohorts of up to 10 patients were treated with an incremental dose (60 Gy, 90 Gy, 120 Gy) of 166Ho-MS to the treatment volume. The primary endpoint was to obtain a target volume dose of ≥ 120 Gy in 9/10 patients within a cohort. RESULTS: Twelve patients were treated (male 10; median age, 66.5 years (IQR, [64.3-71.7])) with a median tumor diameter of 2.7 cm (IQR, [2.1-4.0]). At a treatment volume absorbed dose of 90 Gy, the primary endpoint was met with a median absorbed target volume dose of 138 Gy (IQR, [127-145]). No local recurrences were found within 1-year follow-up. CONCLUSION: Adjuvant (super-)selective infusion of 166Ho-MS after RFA for the treatment of HCC can be administered safely at a dose of 90 Gy to the treatment volume while reaching a dose of ≥ 120 Gy to the target volume and may be a favorable adjuvant therapy for HCC lesions 2-5 cm. TRIAL REGISTRATION: Clinicaltrials.gov NCT03437382 . (registered: 19-02-2018).


Asunto(s)
Carcinoma Hepatocelular , Embolización Terapéutica , Holmio , Neoplasias Hepáticas , Radioisótopos , Humanos , Carcinoma Hepatocelular/radioterapia , Carcinoma Hepatocelular/terapia , Carcinoma Hepatocelular/diagnóstico por imagen , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/terapia , Masculino , Holmio/uso terapéutico , Femenino , Anciano , Persona de Mediana Edad , Embolización Terapéutica/métodos , Radioisótopos/uso terapéutico , Radioisótopos/administración & dosificación , Ablación por Radiofrecuencia/métodos , Dosificación Radioterapéutica , Estadificación de Neoplasias , Distribución Tisular
4.
HPB (Oxford) ; 26(7): 919-927, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38604828

RESUMEN

INTRODUCTION: This study investigates the incidence of extrahepatic perfusion and incomplete hepatic perfusion at intraoperative methylene blue testing and on postoperative nuclear imaging in patients undergoing hepatic arterial infusion pump (HAIP) chemotherapy. METHODS: The first 150 consecutive patients who underwent pump implantation in the Netherlands were included. All patients underwent surgical pump implantation with the catheter in the gastroduodenal artery. All patients underwent intraoperative methylene blue testing and postoperative nuclear imaging (99mTc-Macroaggregated albumin SPECT/CT) to determine perfusion via the pump. RESULTS: Patients were included between January-2018 and December-2021 across eight centers. During methylene blue testing, 29.3% had extrahepatic perfusion, all successfully managed intraoperatively. On nuclear imaging, no clinically relevant extrahepatic perfusion was detected (0%, 95%CI: 0.0-2.5%). During methylene blue testing, 2.0% had unresolved incomplete hepatic perfusion. On postoperative nuclear imaging, 8.1% had incomplete hepatic perfusion, leading to embolization in only 1.3%. CONCLUSION: Methylene blue testing during pump placement for intra-arterial chemotherapy identified extrahepatic perfusion in 29.3% of patients, but could be resolved intraoperatively in all patients. Postoperative nuclear imaging found no clinically relevant extrahepatic perfusion and led to embolization in only 1.3% of patients. The role of routine nuclear imaging after HAIP implantation should be studied in a larger cohort.


Asunto(s)
Arteria Hepática , Infusiones Intraarteriales , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Antineoplásicos/administración & dosificación , Arteria Hepática/diagnóstico por imagen , Incidencia , Bombas de Infusión Implantables , Circulación Hepática , Neoplasias Hepáticas/cirugía , Azul de Metileno/administración & dosificación , Países Bajos/epidemiología , Estudios Retrospectivos , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único , Agregado de Albúmina Marcado con Tecnecio Tc 99m/administración & dosificación
5.
Artículo en Inglés | MEDLINE | ID: mdl-38030743

RESUMEN

BACKGROUND: The current expansion of image-guided surgery is closely related to the role played by radio-guided surgery in supporting the sentinel node (SN) procedure during more than three decades. The so-called triple approach (lymphoscintigraphy, gamma probe detection and blue dye) was not only essential in the seminal validation of the SN procedure but also a first collective learning effort based on skill transfer and outcome-related evaluation which laid the fundaments to delineate the field of intraoperative molecular imaging (IMI) based on a similar multimodality approach and multidisciplinary practice. METHODS: These elements are also becoming valid in the current incorporation of SPECT/CT and PET/CT to existing and new protocols of IMI procedures and SN mapping concerning other clinical applications. On the other hand, there is a growing tendency to combine novel modern technologies in an allied role with gamma guidance in the operating room following the development of hybrid tracers and multimodal detection approaches. Against this background, learning initiatives are required for professionals working in this area. RESULTS: This objective has led to a group of European practitioners with large experience in SN mapping and IMI applications to give shape to a programme made up out of specific learning modules aimed to be used as a conductive thread in peripherical or centralised training instances concerning the topic. CONCLUSION: The presented work, written as a tutorial review, is placed in an available prior-art context and is primarily aimed at medical and paramedical practitioners as well as at hardware and software developers.

6.
Eur J Nucl Med Mol Imaging ; 50(8): 2282-2291, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36929210

RESUMEN

BACKGROUND: Lymph node (LN) metastasis is a relevant predictor for survival in patients with a.o. penile cancer (PeCa), malignant melanoma. The sentinel node (SN) procedure comprises targeted resection of the first tumour-draining SNs. Here, the hybrid tracer indocyanine green (ICG)-99mTc-nanocolloid has been used for several years to combine optical and nuclear detection. Recently, the resource of the nanocolloid precursor stopped production and the precursor was replaced by a different but chemically comparable colloid, nanoscan. Our aim was to study the performance of ICG-99mTc-nanoscan compared to ICG-99mTc-nanocolloid from a nuclear and surgical perspective. METHODS: Twenty-four patients with either PeCa or head-and-neck (H&N) melanoma and scheduled for a SN procedure were included. The initial group (n = 11) received ICG-99mTc-nanocolloid until no longer available; the second group (n = 13) received ICG-99mTc-nanoscan. Tracer uptake was assessed on lymphoscintigraphy and single-photon emission (SPECT). Intraoperatively, SNs were identified using gamma tracing and fluorescence imaging. Ex vivo (back-table) measurements were conducted to quantify the fluorescence emissions. Chemical analysis was performed to compare the ICG assembly on both precursors. RESULTS: The mean tracer uptake in the SNs was similar for ICG-99mTc-nanocolloid (2.2 ± 4.3%ID) and ICG-99mTc-nanoscan (1.8 ± 2.6%ID; p = 0.68). 3 SNs (interquartile range (IQR) 3-4) were detected on lymphoscintigraphy in PeCa patients receiving ICG-99mTc-nanoscan compared to 2 SNs (IQR 2-3) in PeCa patients receiving ICG-99mTc-nanocolloid (p = 0.045), no differences were observed in H&N patients. Back-table measurements of resected SNs revealed a lower total fluorescence intensity in the ICG-99mTc-nanoscan group (24*109 arbitrary units (A.U) IQR 1.6*109-14*109 in the ICG-99mTc-nanocolloid group versus 4.6*109 A.U. IQR 2.4*109-42*109 in the ICG-99mTc-nanoscan group, p = 0.0054). This was consistent with a larger degree of "stacked" ICG observed in the nanoscan formulation. No tracer-related adverse events were reported. CONCLUSIONS: Based on this retrospective analysis, we can conclude that ICG-99mTc-nanoscan has similar capacity for SN identification as ICG-99mTc-nanocolloid and can safely be implemented in SN procedures.


Asunto(s)
Melanoma , Medicina Nuclear , Neoplasias del Pene , Ganglio Linfático Centinela , Masculino , Humanos , Verde de Indocianina , Biopsia del Ganglio Linfático Centinela/métodos , Estudios Retrospectivos , Ganglio Linfático Centinela/cirugía , Melanoma/diagnóstico por imagen , Melanoma/cirugía , Melanoma/patología , Radiofármacos , Metástasis Linfática , Neoplasias del Pene/patología , Agregado de Albúmina Marcado con Tecnecio Tc 99m
7.
Artículo en Inglés | MEDLINE | ID: mdl-38012448

RESUMEN

PURPOSE: Prostate-specific membrane antigen (PSMA) is increasingly considered as a molecular target to achieve precision surgery for prostate cancer. A Delphi consensus was conducted to explore expert views in this emerging field and to identify knowledge and evidence gaps as well as unmet research needs that may help change practice and improve oncological outcomes for patients. METHODS: One hundred and five statements (scored by a 9-point Likert scale) were distributed through SurveyMonkey®. Following evaluation, a consecutive second round was performed to evaluate consensus (16 statements; 89% response rate). Consensus was defined using the disagreement index, assessed by the research and development project/University of California, Los Angeles appropriateness method. RESULTS: Eighty-six panel participants (72.1% clinician, 8.1% industry, 15.1% scientists, and 4.7% other) participated, most with a urological background (57.0%), followed by nuclear medicine (22.1%). Consensus was obtained on the following: (1) The diagnostic PSMA-ligand PET/CT should ideally be taken < 1 month before surgery, 1-3 months is acceptable; (2) a 16-20-h interval between injection of the tracer and surgery seems to be preferred; (3) PSMA targeting is most valuable for identification of nodal metastases; (4) gamma, fluorescence, and hybrid imaging are the preferred guidance technologies; and (5) randomized controlled clinical trials are required to define oncological value. Regarding surgical margin assessment, the view on the value of PSMA-targeted surgery was neutral or inconclusive. A high rate of "cannot answer" responses indicates further study is necessary to address knowledge gaps (e.g., Cerenkov or beta-emissions). CONCLUSIONS: This Delphi consensus provides guidance for clinicians and researchers that implement or develop PSMA-targeted surgery technologies. Ultimately, however, the consensus should be backed by randomized clinical trial data before it may be implemented within the guidelines.

8.
Q J Nucl Med Mol Imaging ; 65(3): 244-260, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34105338

RESUMEN

INTRODUCTION: Nuclear medicine has a crucial role in interventional strategies where a combination between the increasing use of targeted radiotracers and intraprocedural detection modalities enable novel, but often complex, targeted procedures in both the fields of interventional radiology and surgery. 3D navigation approaches could assist the interventional radiologist or surgeon in such complex procedures. EVIDENCE ACQUISITION: This review aimed to provide a comprehensive overview of the current application of computer-assisted navigation strategies based on nuclear imaging to assist in interventional radiology and image-guided surgery. This work starts with a brief overview of the typical navigation workflow from a technical perspective, which is followed by the different clinical applications organized based on their anatomical organ of interest. EVIDENCE SYNTHESIS: Although many studies have proven the feasibility of PET- and SPECT-based navigation strategies for various clinical applications in both interventional radiology and surgery, the strategies are spread widely in both navigation workflows and clinical indications, evaluated in small patient groups. Hence, no golden standard has yet been established. CONCLUSIONS: Despite that the clinical outcome is yet to be determined in large patient cohorts, navigation seems to be a promising technology to translate nuclear medicine findings, provided by PET- and SPECT-based molecular imaging, to the intervention and operating room. Interventional Nuclear Medicine (iNM) has an exciting future to come using both PET- and SPECT-based navigation.


Asunto(s)
Medicina Nuclear , Cirugía Asistida por Computador , Humanos , Tomografía de Emisión de Positrones , Radiología Intervencionista , Tomografía Computarizada de Emisión de Fotón Único
9.
Q J Nucl Med Mol Imaging ; 65(1): 4-19, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33494584

RESUMEN

Within interventional nuclear medicine (iNM) a prominent role is allocated for the sub-discipline of radioguided surgery. Unique for this discipline is the fact that an increasing number of clinical indications (e.g. lymphatic mapping, local tumor demarcation and/or tumor receptor targeted applications) have been adopted into routine care. The clinical integration is further strengthened by technical innovations in chemistry and engineering that enhance the translational potential of radioguided procedures in iNM. Together, these features not only ensure ongoing expansion of iNM but also warrant a lasting clinical impact for the sub-discipline of radioguided surgery.


Asunto(s)
Neoplasias/diagnóstico por imagen , Cintigrafía/métodos , Radiofármacos/química , Humanos , Neoplasias/cirugía , Medicina Nuclear , Tomografía Computarizada por Tomografía de Emisión de Positrones , Radiofármacos/administración & dosificación , Radiofármacos/metabolismo , Flujo de Trabajo
10.
Gynecol Oncol ; 159(3): 672-680, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-33041071

RESUMEN

OBJECTIVE: The aim of this study was to assess the superiority of ICG-99mTc-nanocolloid for the intraoperative visual detection of sentinel lymph nodes (SLNs) in vulvar squamous cell carcinoma (VSCC) patients compared to standard SLN detection using 99mTc-nanocolloid with blue dye. METHODS: In this multicenter, randomized controlled trial, VSCC patients underwent either the standard SLN procedure or with the hybrid tracer ICG-99mTc-nanocolloid. The primary endpoint was the percentage of fluorescent SLNs compared to blue SLNs. Secondary endpoints were successful SLN procedures, surgical outcomes and postoperative complications. RESULTS: Forty-eight patients were randomized to the standard (n = 24) or fluorescence imaging group (n = 24) using ICG-99mTc-nanocolloid. The percentage of blue SLNs was 65.3% compared to 92.5% fluorescent SLNs (p < 0.001). A successful SLN procedure was obtained in 92.1% of the groins in the standard group and 97.2% of the groins in the fluorescence imaging group (p = 0.33). Groups did not differ in surgical outcome, although more short-term postoperative complications were documented in the standard group (p = 0.041). CONCLUSIONS: Intraoperative visual detection of SLNs in patients with VSCC using ICG-99mTc-nanocolloid was superior compared to 99mTc-nanocolloid and blue dye. The rate of successful SLN procedures between both groups was not significantly different. Fluorescence imaging has potential to be used routinely in the SLN procedure in VSCC patients to facilitate the search by direct visualization. CLINICAL TRIAL REGISTRATION: Netherlands Trial Register (Trial ID NL7443).


Asunto(s)
Carcinoma de Células Escamosas/diagnóstico , Cuidados Intraoperatorios/métodos , Metástasis Linfática/diagnóstico , Ganglio Linfático Centinela/diagnóstico por imagen , Neoplasias de la Vulva/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Carcinoma de Células Escamosas/secundario , Carcinoma de Células Escamosas/cirugía , Colorantes/administración & dosificación , Femenino , Humanos , Escisión del Ganglio Linfático , Metástasis Linfática/terapia , Persona de Mediana Edad , Países Bajos , Tempo Operativo , Imagen Óptica/métodos , Radiofármacos/administración & dosificación , Ganglio Linfático Centinela/patología , Ganglio Linfático Centinela/cirugía , Biopsia del Ganglio Linfático Centinela/métodos , Factores de Tiempo , Neoplasias de la Vulva/patología , Vulvectomía
11.
Int J Gynecol Cancer ; 25(6): 1086-93, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25768079

RESUMEN

OBJECTIVE: Near-infrared (NIR) fluorescence imaging using indocyanine green (ICG) has recently been introduced to improve the sentinel lymph node (SLN) procedure. Several optical tracers have been successfully tested. However, the optimal tracer formulation is still unknown. This study evaluates the performance of ICG-technetium-99m (99mTc)-nanocolloid in relation to 2 most commonly used ICG-based formulas during SLN biopsy in vulvar cancer. METHODS AND MATERIALS: Twelve women who planned to undergo SLN biopsy for stage I vulvar cancer were prospectively included. Sentinel lymph node mapping was performed using the dual-modality radioactive and NIR fluorescence tracer ICG-99mTc-nanocolloid. All patients underwent combined SLN localization using NIR fluorescence and the (current) gold standard using blue dye and radioactive guidance. RESULTS: In all 12 patients, at least 1 SLN was detected during surgery. A total of 21 lymph nodes (median 2; range, 1-3) were resected. Median time between skin incision and first SLN detection was 8 (range, 1-22) minutes. All resected SLNs were both radioactive and fluorescent, although only 13 (62%) of 21 SLNs stained blue. Median brightness of exposed SLNs, expressed as signal-to-background ratio, was 5.4 (range, 1.8-11.8). Lymph node metastases were found in 3 patients. CONCLUSIONS: Near-infrared fluorescence-guided SLN mapping is feasible and outperforms blue dye staining. Premixing ICG with 99mTc-nanocolloid provides real-time intraoperative imaging of the SN and seems to be the optimal tracer combination in terms of intraoperative detection rate of the SN (100%). Moreover, ICG-99mTc-nanocolloid allows the administration of a 5-times lower injected dose of ICG (compared with ICG and ICG absorbed to human serum albumin) and can be injected up to 20 hours before surgery.


Asunto(s)
Biopsia Guiada por Imagen/métodos , Verde de Indocianina/farmacocinética , Biopsia del Ganglio Linfático Centinela , Agregado de Albúmina Marcado con Tecnecio Tc 99m/farmacocinética , Neoplasias de la Vulva/diagnóstico por imagen , Neoplasias de la Vulva/patología , Adulto , Anciano , Anciano de 80 o más Años , Colorantes/farmacocinética , Femenino , Fluorescencia , Estudios de Seguimiento , Humanos , Persona de Mediana Edad , Estadificación de Neoplasias , Pronóstico , Estudios Prospectivos , Cintigrafía , Radiofármacos/farmacocinética , Espectroscopía Infrarroja Corta , Distribución Tisular
12.
J Nucl Med ; 65(10): 1505-1511, 2024 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-38991755

RESUMEN

Following early acceptance by urologists, the use of surgical robotic platforms is rapidly spreading to other surgical fields. This empowerment of surgical perception via robotic advances occurs in parallel to developments in intraoperative molecular imaging. Convergence of these efforts creates a logical incentive to advance the decades-old image-guided robotics paradigm. This yields new radioguided surgery strategies set to optimally exploit the symbiosis between the growing clinical translation of robotics and molecular imaging. These strategies intend to advance surgical precision by increasing dexterity and optimizing surgical decision-making. In this state-of-the-art review, topic-related developments in chemistry (tracer development) and engineering (medical device development) are discussed, and future scientific robotic growth markets for molecular imaging are presented.


Asunto(s)
Imagen Molecular , Procedimientos Quirúrgicos Robotizados , Cirugía Asistida por Computador , Humanos , Procedimientos Quirúrgicos Robotizados/métodos , Imagen Molecular/métodos , Cirugía Asistida por Computador/métodos
13.
Expert Rev Med Devices ; 21(5): 349-358, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38722051

RESUMEN

INTRODUCTION: Surgery and biomedical imaging encompass a big share of the medical-device market. The ever-mounting demand for precision surgery has driven the integration of these two into the field of image-guided surgery. A key-question herein is how imaging modalities can guide the surgical decision-making process. Through performance-based design, chemists, engineers, and doctors need to build a bridge between imaging technologies and surgical challenges. AREAS-COVERED: This perspective article highlights the complementary nature between the technological design of an image-guidance modality and the type of procedure performed. The specific roles of the involved professionals, imaging technologies, and surgical indications are addressed. EXPERT-OPINION: Molecular-image-guided surgery has the potential to advance pre-, intra- and post-operative tissue characterization. To achieve this, surgeons need the access to well-designed indication-specific chemical-agents and detection modalities. Hereby, some technologies stimulate exploration ('go'), while others stimulate caution ('stop'). However, failing to adequately address the indication-specific needs rises the risk of incorrect tool employment and sub-optimal surgical performance. Therefore, besides the availability of new technologies, market growth is highly dependent on the practical nature and impact on real-life clinical care. While urology currently takes the lead in the widespread implementation of image-guidance technologies, the topic is generic and its popularity spreads rapidly within surgical oncology.


Asunto(s)
Cirugía Asistida por Computador , Humanos , Cirugía Asistida por Computador/instrumentación , Cirugía Asistida por Computador/métodos , Diagnóstico por Imagen/métodos , Diagnóstico por Imagen/instrumentación , Medicina de Precisión/métodos , Medicina de Precisión/instrumentación , Equipos y Suministros
14.
Cancers (Basel) ; 16(15)2024 Jul 29.
Artículo en Inglés | MEDLINE | ID: mdl-39123421

RESUMEN

Computer tomography (CT)-guided percutaneous core biopsies are currently the gold standard in diagnostic procedures for patients with bone lesions of unknown kind. CT-guided biopsies can lead to misdiagnosis or repetition of biopsies in case of small or heterogeneous lesions. We hypothesize that molecular image guidance could be used to optimize the biopsy strategy, by supporting the detection of heterogeneous lesions or lesions without radiographic substrate. To evaluate this hypothesis, we investigated if and how the addition of 2-deoxy-2-18F-fluoro-D-glucose-positron emission tomography (18F-FDG-PET)/CT could augment routine CT-guided bone biopsies. To this end, 106 patients who underwent a CT-guided bone biopsy between April 2019 and April 2020, obtained from either a vertebral or peripheral bone, were included. Patients were divided into 2 groups: 36 patients received an 18F-FDG-PET/CT scan prior to their CT-guided bone biopsy (PET group), while 70 patients only had a morphological CT scan (CT group). Histopathology was used to categorize biopsies into five subgroups (inconclusive, benign, malignant or infectious disease, or normal tissue). In the PET group, the number of conclusive biopsies was significantly higher compared to the CT group (N = 33/36 (92%) versus N = 53/70 (76%); p < 0.05). Furthermore, the number of first-try biopsies was lower in the PET group compared to the CT group (1.9 vs. 2.54, p = 0.051). In conclusion, 18F-FDG-PET/CT imaging significantly increased the success rate of first-try CT-guided bone biopsies by showing less inconclusive biopsies and misdiagnosis.

15.
J Nucl Med ; 65(8): 1301-1306, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-39025649

RESUMEN

Liver cancer is a leading cause of cancer deaths worldwide. Surgical resection of superficial hepatic lesions is increasingly guided by the disrupted bile excretion of the fluorescent dye indocyanine green (ICG). To extend this approach to deeper lesions, a dedicated bimodal tracer that facilitates both fluorescence guidance and radioguidance was developed. Methods: A tracer comprising a methylated cyanine-5 (Cy5) fluorescent dye and a mercaptoacetyltriserine chelate (hHEPATO-Cy5) was synthesized and characterized. Cellular uptake and excretion were evaluated in hepatocyte cultures (2-dimensional culture and in vitro lesion model), using a fluorescent bile salt, MitoTracker dye, and methylated Cy5 as a control. After radiolabeling, the pharmacokinetics of 99mTc-hHEPATO-Cy5 were assessed in mice over 24 h (percentage injected dose and percentage injected dose per gram of tissue, SPECT/CT imaging and fluorescence imaging). The ability to provide real-time fluorescence guidance during robot-assisted hepatobiliary surgery was evaluated in a porcine model using ICG as a reference. Results: The unique molecular signature of hHEPATO-Cy5 promotes hepatobiliary excretion. In vitro studies on hepatocytes showed that where methylated Cy5 remained internalized, hHEPATO-Cy5 showed fast clearance (10 min) similar to that of fluorescent bile salt. In vivo use of 99mTc-hHEPATO-Cy5 in mice revealed liver accumulation and rapid biliary clearance. The effectiveness of bile clearance was best exemplified by the 2-orders-of-magnitude reduction in count rate for the gallbladder (P = 0.008) over time. During hepatobiliary surgery in a porcine model, hHEPATO-Cy5 enabled fluorescence-based lesion identification comparable to that of ICG. Conclusion: The bimodal 99mTc-hHEPATO-Cy5 provides an effective means to identify liver lesions. Uniquely, it helps overcome the shortcomings of fluorescence-only approaches by allowing for an extension to in-depth radioguidance.


Asunto(s)
Carbocianinas , Cirugía Asistida por Computador , Animales , Carbocianinas/química , Ratones , Hígado/diagnóstico por imagen , Hígado/metabolismo , Hígado/cirugía , Distribución Tisular , Humanos , Trazadores Radiactivos , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único , Porcinos , Hepatocitos/metabolismo
16.
J Nucl Med ; 65(4): 548-554, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38485277

RESUMEN

Prostate-specific membrane antigen (PSMA) PET is used to select patients with recurrent prostate cancer for metastasis-directed therapy. A surgical approach can be achieved through radioguided surgery (RGS), using a Drop-In γ-probe that traces lesions that accumulate the radioactive signal. With the aim of guiding patient selection for salvage surgery, we studied the correlation between the SUVmax of lesions on preoperative PSMA PET/CT and their intraoperative counts/s measured using the Drop-In γ-probe. Methods: A secondary analysis based on the prospective, single-arm, and single-center feasibility study was conducted (NCT03857113). Patients (n = 29) with biochemical recurrence after previous curative-intent therapy and a maximum of 3 suggestive lesions within the pelvis on preoperative PSMA PET/CT were included. Patients treated with androgen deprivation therapy within 6 mo before surgery were excluded. All patients received an intravenous injection of 99mTc-PSMA-I&S 1 d before surgery. Radioguidance was achieved using a Drop-In γ-probe. Correlation was determined using the Spearman rank correlation coefficient (ρs). Subgroup analysis was based on the median SUVmax Results: In total, 33 lesions were visible on the PSMA PET/CT images, with a median overall SUVmax of 6.2 (interquartile range [IQR], 4.2-9.7). RGS facilitated removal of 31 lesions. The median Drop-In counts/s were 134 (IQR, 81-220) in vivo and 109 (IQR, 72-219) ex vivo. The intensity of the values correlated with SUVmax (ρs = 0.728 and 0.763, respectively; P < 0.001). Subgroup analysis based on median SUVmax in the group with an SUVmax of less than 6 showed no statistically significant correlation with the numeric signal in vivo (ρs = 0.382; P = 0.221) or the signal-to-background-ratio (ρs = 0.245; P = 0.442), whereas the group with an SUVmax of 6 or more showed respective statistically significant positive correlations (ρs = 0.774 [P < 0.001] and ρs = 0.647 [P = 0.007]). Conclusion: Our findings indicate that there is a direct relation between SUVmax on PSMA PET/CT and the readout recorded by the surgical Drop-In probe, thereby indicating that SUVmax can be used to select patients for PSMA RGS. For more definitive subgroup definitions for treatment recommendations, further studies are necessary to validate the present findings.


Asunto(s)
Neoplasias de la Próstata , Masculino , Humanos , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/cirugía , Neoplasias de la Próstata/patología , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Antagonistas de Andrógenos , Estudios Prospectivos , Recurrencia Local de Neoplasia/patología , Radioisótopos de Galio
17.
J Clin Med ; 12(3)2023 Jan 24.
Artículo en Inglés | MEDLINE | ID: mdl-36769566

RESUMEN

The targeted delivery of anti-cancer drugs and isotopes is one of the most pursued goals in anti-cancer therapy. One of the prime examples of such an application is the intra-arterial injection of microspheres containing cytostatic drugs or radioisotopes during hepatic embolization procedures. Therapy based on the application of microspheres revolves around vascular occlusion, complemented with local therapy in the form of trans-arterial chemoembolization (TACE) or radioembolization (TARE). The broadest implementation of these embolization strategies currently lies within the treatment of untreatable hepatocellular cancer (HCC) and metastatic colorectal cancer. This review aims to describe the state-of-the-art TACE and TARE technologies investigated in the clinical setting for HCC and addresses current trials and new developments. In addition, chemical properties and advancements in microsphere carrier systems are evaluated, and possible improvements in embolization therapy based on the modification of and functionalization with therapeutical loads are explored.

18.
Eur J Surg Oncol ; 49(10): 107006, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37572588

RESUMEN

INTRODUCTION: In early-stage vulvar squamous cell carcinoma (VSCC) a sentinel lymph node (SLN) procedure is regarded successful if at least one SLN is removed with minimal residual radioactivity. An inguinofemoral lymphadenectomy is considered if not all SLNs visualized on lymphoscintigraphy can be found, with subsequent increased morbidity. We correlated lymphoscintigraphy findings with surgical outcome and groin recurrence with focus on number of SLNs found. METHODS: This study concerns a retrospective cohort of 171 women treated for early-stage VSCC who underwent a SLN procedure between 2000 and 2020. The risk of groin recurrence was compared after either a successful or complete SLN procedure, i.e. removal of all SLNs that were visualized on lymphoscintigraphy. RESULTS: In 13 (7.6%) groins of 171 patients SLN visualization on lymphoscintigraphy failed. In 230 of the 246 (93.5%) groins in which a SLN was visualized, at least one SLN was found during surgery. In 224 of the 246 (91.1%) groins the SLN procedure was regarded either successful (n = 14) or complete (n = 210). An isolated groin recurrence was documented in 5 out of 192 (2.6%, 95%-CI; 0.34 to 4.9) SLN-negative groins after a median follow-up of 47.0 months. All recurrences were noted in the complete SLN group (5/180 groins). The difference with the successful SLN group (0/12 groins) was not significant. CONCLUSION: Risk of groin recurrence was 2.6% after SLN negative biopsy in early-stage VSCC. The risk appeared not increased if at least one SLN was found with minimal residual radioactivity, in case more SLNs were visualized on lymphoscintigraphy.


Asunto(s)
Carcinoma de Células Escamosas , Linfadenopatía , Ganglio Linfático Centinela , Neoplasias de la Vulva , Humanos , Femenino , Ganglio Linfático Centinela/diagnóstico por imagen , Ganglio Linfático Centinela/cirugía , Ganglio Linfático Centinela/patología , Ingle/cirugía , Ingle/patología , Neoplasias de la Vulva/diagnóstico por imagen , Neoplasias de la Vulva/cirugía , Neoplasias de la Vulva/patología , Estudios Retrospectivos , Linfocintigrafia/métodos , Biopsia del Ganglio Linfático Centinela/métodos , Escisión del Ganglio Linfático/métodos , Ganglios Linfáticos/diagnóstico por imagen , Ganglios Linfáticos/cirugía , Ganglios Linfáticos/patología , Linfadenopatía/patología , Carcinoma de Células Escamosas/diagnóstico por imagen , Carcinoma de Células Escamosas/cirugía , Carcinoma de Células Escamosas/patología , Resultado del Tratamiento
19.
Bone Joint Res ; 12(1): 72-79, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36649933

RESUMEN

AIMS: Arthroplasty surgery of the knee and hip is performed in two to three million patients annually. Periprosthetic joint infections occur in 4% of these patients. Debridement, antibiotics, and implant retention (DAIR) surgery aimed at cleaning the infected prosthesis often fails, subsequently requiring invasive revision of the complete prosthetic reconstruction. Infection-specific imaging may help to guide DAIR. In this study, we evaluated a bacteria-specific hybrid tracer (99mTc-UBI29-41-Cy5) and its ability to visualize the bacterial load on femoral implants using clinical-grade image guidance methods. METHODS: 99mTc-UBI29-41-Cy5 specificity for Stapylococcus aureus was assessed in vitro using fluorescence confocal imaging. Topical administration was used to highlight the location of S. aureus cultured on femoral prostheses using fluorescence imaging and freehand single photon emission CT (fhSPECT) scans. Gamma counting and fhSPECT were used to quantify the bacterial load and monitor cleaning with chlorhexidine. Microbiological culturing helped to relate the imaging findings with the number of (remaining) bacteria. RESULTS: Bacteria could be effectively stained in vitro and on prostheses, irrespective of the presence of biofilm. Infected prostheses revealed bacterial presence on the transition zone between the head and neck, and in the screw hole. Qualitative 2D fluorescence images could be complemented with quantitative 3D fhSPECT scans. Despite thorough chlorhexidine treatments, 28% to 44% of the signal remained present in the locations of the infection that were identified using imaging, which included 500 to 2,000 viable bacteria. CONCLUSION: The hybrid tracer 99mTc-UBI29-41-Cy5 allowed effective bacterial staining. Qualitative real-time fluorescence guidance could be effectively combined with nuclear imaging that enables quantitative monitoring of the effectiveness of cleaning strategies.Cite this article: Bone Joint Res 2023;12(1):72-79.

20.
Mol Imaging Biol ; 25(1): 180-189, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-35711014

RESUMEN

PURPOSE: Surgical fluorescence guidance has gained popularity in various settings, e.g., minimally invasive robot-assisted laparoscopic surgery. In pursuit of novel receptor-targeted tracers, the field of fluorescence-guided surgery is currently moving toward increasingly lower signal intensities. This highlights the importance of understanding the impact of low fluorescence intensities on clinical decision making. This study uses kinematics to investigate the impact of signal-to-background ratios (SBR) on surgical performance. METHODS: Using a custom grid exercise containing hidden fluorescent targets, a da Vinci Xi robot with Firefly fluorescence endoscope and ProGrasp and Maryland forceps instruments, we studied how the participants' (N = 16) actions were influenced by the fluorescent SBR. To monitor the surgeon's actions, the surgical instrument tip was tracked using a custom video-based tracking framework. The digitized instrument tracks were then subjected to multi-parametric kinematic analysis, allowing for the isolation of various metrics (e.g., velocity, jerkiness, tortuosity). These were incorporated in scores for dexterity (Dx), decision making (DM), overall performance (PS) and proficiency. All were related to the SBR values. RESULTS: Multi-parametric analysis showed that task completion time, time spent in fluorescence-imaging mode and total pathlength are metrics that are directly related to the SBR. Below SBR 1.5, these values substantially increased, and handling errors became more frequent. The difference in Dx and DM between the targets that gave SBR < 1.50 and SBR > 1.50, indicates that the latter group generally yields a 2.5-fold higher Dx value and a threefold higher DM value. As these values provide the basis for the PS score, proficiency could only be achieved at SBR > 1.55. CONCLUSION: By tracking the surgical instruments we were able to, for the first time, quantitatively and objectively assess how the instrument positioning is impacted by fluorescent SBR. Our findings suggest that in ideal situations a minimum SBR of 1.5 is required to discriminate fluorescent lesions, a substantially lower value than the SBR 2 often reported in literature.


Asunto(s)
Colorantes , Cirugía Asistida por Computador , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA