Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Microcirculation ; 31(2): e12843, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38174616

RESUMEN

INTRODUCTION: Coronary microvascular dysfunction (CMD) plays a major role in hypertrophic cardiomyopathy (HCM) physiopathology but its assessment in clinical practice remains a challenge. Nowadays, innovations in invasive and noninvasive coronary evaluation using multimodal imaging provide options for the diagnosis of CMD. The objective of the present study was to investigate if new multimodal imaging diagnosis of CMD could detect HCM patients with more impaired cardiac function by left atrioventricular coupling index (LACI). METHODS AND RESULTS: A total of 32 consecutive patients with a confirmed diagnosis of HCM (62 ± 13 years, 62% men) were prospectively screened for CMD using a multimodal imaging method. LACI was assessed by cardiovascular magnetic resonance imaging. Fifteen (47%) patients had CMD by multimodal imaging method. Patients with CMD presented a significantly higher LACI (48.5 ± 25.4 vs. 32.5 ± 10.6, p = .03). A multivariate logistic regression analysis demonstrated that CMD was independently associated with LACI (OR = 1.069, 95% CI 1.00-1.135, p = .03). CONCLUSION: Multimodal imaging diagnosis of CMD is applicable to HCM patients and is associated with more impaired cardiac function.


Asunto(s)
Cardiomiopatía Hipertrófica , Isquemia Miocárdica , Masculino , Humanos , Femenino , Circulación Coronaria , Cardiomiopatía Hipertrófica/diagnóstico por imagen , Imagen por Resonancia Magnética , Imagen Multimodal
2.
Cardiovasc Ultrasound ; 22(1): 5, 2024 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-38745211

RESUMEN

BACKGROUND: Coronary microvascular dysfunction (CMD) refers to structural and functional abnormalities of the coronary microcirculation, which may be diagnosed using invasive coronary physiology. CMD is responsible for impaired diastolic cardiac function. It has recently been suggested that left atrial strain (LASr) represents a highly sensitive tool for detecting cardiac diastolic function abnormalities. Accordingly, the aim of this study was to investigate the relationship between CMD and LASr. METHODS: Consecutively enrolled patients with non-obstructed coronary arteries (NOCA) underwent CMD and LASr evaluation by invasive thermodilution and noninvasive echocardiography, respectively. RESULTS: Forty-two (42) patients were included, out of which 26 presented with CMD. There were no significant differences between CMD-positive and negative patients in terms of clinical and echocardiographic characteristics. LASr was significantly reduced in patients with CMD (24.6% ± 6.1 vs. 30.3 ± 7.8%, p = 0.01). A moderate correlation was observed between coronary flow reserve and LAsr (r = 0.47, p = 0.002). A multivariate logistic regression analysis demonstrated that CMD was independently associated with LASr (OR = 0.88, 95%CI 0.78-0.99.135, p = 0.04). A LASr cut-off of 25.5% enabled an optimal classification of patients with or without CMD. CONCLUSION: Patients with NOCA and CMD had a significantly reduced LASr compared with patients without CMD, suggesting the early impairment of diastolic function in these patients.


Asunto(s)
Circulación Coronaria , Vasos Coronarios , Ecocardiografía , Atrios Cardíacos , Microcirculación , Humanos , Masculino , Femenino , Microcirculación/fisiología , Persona de Mediana Edad , Circulación Coronaria/fisiología , Atrios Cardíacos/fisiopatología , Atrios Cardíacos/diagnóstico por imagen , Ecocardiografía/métodos , Vasos Coronarios/fisiopatología , Vasos Coronarios/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/fisiopatología , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/complicaciones , Anciano , Función del Atrio Izquierdo/fisiología , Termodilución/métodos , Diástole
3.
J Nucl Cardiol ; 30(4): 1656-1667, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-36813934

RESUMEN

OBJECTIVES: To assess the diagnostic performances of CZT myocardial perfusion reserve (MPR) for the detection of territories with simultaneous impaired coronary flow reserve (CFR) and index of microcirculatory resistance (IMR) in patients without obstructive coronary artery disease. METHODS: Patients were prospectively included before being referred for coronary angiography. All patients underwent CZT MPR before invasive coronary angiography (ICA) and coronary physiology assessment. Rest and dipyridamole-induced stress myocardial blood flow (MBF) and MPR were quantified using 99mTc-SestaMIBI and a CZT camera. Fractional flow reserve (FFR), Thermodilution CFR, and IMR were assessed during ICA. RESULTS: Between December 2016 and July 2019, 36 patients were included. 25/36 patients presented no obstructive coronary artery disease. A complete functional assessment was performed in 32 arteries. No territory presented a significant ischemia on CZT myocardial perfusion imaging. A moderate yet significant correlation was observed between regional CZT MPR and CFR (r = 0.4, P = .03). Sensitivity, specificity, positive and negative predictive value, and accuracy of regional CZT MPR versus the composite invasive criterion (impaired CFR and IMR) were 87 [47% to 99%], 92% [73% to 99%], 78% [47% to 93%], 96% [78% to 99%], and 91% [75% to 98%], respectively. All territories with a regional CZT MPR ≤ 1.8 showed a CFR < 2. Regional CZT MPR values were significantly higher in arteries with CFR ≥ 2 and IMR < 25 (negative composite criterion, n = 14) than in those with CFR < 2 and IMR ≥ 25 (2.6 [2.1 to 3.6] versus 1.6 [1.2 to 1.8]), P < .01). CONCLUSION: Regional CZT MPR presented excellent diagnostic performances for the detection of territories with simultaneously impaired CFR and IMR reflecting a very high cardiovascular risk in patients without obstructive coronary artery disease.


Asunto(s)
Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico , Imagen de Perfusión Miocárdica , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Proyectos Piloto , Reserva del Flujo Fraccional Miocárdico/fisiología , Microcirculación/fisiología , Angiografía Coronaria , Perfusión , Imagen de Perfusión Miocárdica/métodos
4.
Eur J Nucl Med Mol Imaging ; 49(3): 809-820, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34417856

RESUMEN

PURPOSE: Coronary microvascular dysfunction (CMVD) plays a major role in the occurrence of cardiovascular events (CVE). We recently suggested the clinical potential of myocardial perfusion entropy (MPE) quantification from SPECT myocardial perfusion images (MPI) for the prognosis of CVE occurrence. We hypothesized that the quantification of MPE from SPECT MPI would allow the assessment of CMVD-related MPE variations in a preclinical model of type 2 diabetes (T2D) including treatment with the anti-diabetic incretin liraglutide (LIR). METHODS: Optimal conditions for the preclinical quantification of MPE using 201Tl SPECT MPI were determined in rats with a T2D-like condition induced by a high-fat diet and streptozotocin injection (feasibility study, n = 43). Using such conditions, echocardiography and post-mortem LV capillary density evaluation were then used in order to assess the effect of LIR and the ability of MPE to assess CMVD (therapeutic study, n = 39). RESULTS: The feasibility study identified dobutamine stress and acute NO synthase and cyclooxygenase inhibition as optimal conditions for the quantification of MPE, with significant increases in MPE being observed in T2D animals (P < 0.01 vs controls). In the therapeutic study, T2D rats were hyperglycemic (5.5 ± 0.5 vs 1.1 ± 0.3 g/L for controls, P < 0.001) and had a significantly lower left ventricular ejection fraction (LVEF) (65 ± 4% vs 74 ± 9%, P < 0.01) and LV capillary density (2400 ± 300 vs 2800 ± 600 mm-3, P < 0.05). LIR partially restored glycemia (3.9 ± 0.6 g/L, P < 0.05 vs controls and T2D), totally prevented LVEF impairment (72 ± 7%, P = NS vs CTL), with no significant effect on capillary density. MPE was significantly increased in T2D rats (7.6 ± 0.5 vs 7.1 ± 0.5, P < 0.05), with no significant improvement in T2D-LIR rats (7.4 ± 0.4, P = NS vs controls and T2D). CONCLUSION: MPE quantification allowed the preclinical noninvasive assessment of CMVD. Both MPE and capillary density quantification suggested that LIR did not improve T2D-induced CMVD. The relevance of MPE for CMVD assessment warrants further clinical investigation.


Asunto(s)
Diabetes Mellitus Tipo 2 , Imagen de Perfusión Miocárdica , Animales , Diabetes Mellitus Tipo 2/complicaciones , Diabetes Mellitus Tipo 2/diagnóstico por imagen , Entropía , Imagen de Perfusión Miocárdica/métodos , Perfusión , Ratas , Roedores , Volumen Sistólico , Tomografía Computarizada de Emisión de Fotón Único/métodos , Función Ventricular Izquierda/fisiología
5.
Catheter Cardiovasc Interv ; 99(2): 397-404, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34057279

RESUMEN

BACKGROUND: Highly thrombotic coronary lesions continue to be a serious and clinically significant problem that is not effectively and completely addressed by current technology. OBJECTIVES: We aimed to investigate whether a micro-net mesh (MNM) technology covering stent could preserve the index of microcirculatory resistance (IMR) after percutaneous coronary intervention (PCI) in patients with high thrombus burden. METHODS AND RESULTS: Fifty-two patients with non-ST elevation myocardial infarction or ST Elevation Myocardial Infarction and high thrombus burden (TIMI thrombus grade ≥ 3) were randomized into two groups, PCI with a MNM covering stent (MNM group, n = 25) and PCI with any commercially available stent (DES group, n = 27). As the primary endpoint, IMR was measured immediately after PCI using a pressure-temperature sensor-tipped coronary wire. The secondary endpoint was left ventricular ejection fraction (LVEF) at 6 months of follow-up. The IMR in the MNM group was significantly lower in comparison to the DES group (33.2 [21.3, 48.9] vs. 57.2 [39.9, 98.0], p = 0.005). No significant differences were observed in baseline LVEF (54.5 ± 10.2% vs. 53.1 ± 6.87%, p = .57), while LVEF was significantly improved at follow-up in the MNM group (61.1 ± 7.1% vs. 53.9 ± 6.35%, p = .0001). CONCLUSION: MNM technology significantly improved coronary microvascular dysfunction after PCI in patient with acute coronary syndrome and appears as a useful technological option for thrombus management.


Asunto(s)
Intervención Coronaria Percutánea , Trombosis , Humanos , Microcirculación , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Stents , Volumen Sistólico , Mallas Quirúrgicas , Tecnología , Resultado del Tratamiento , Función Ventricular Izquierda
6.
J Nucl Cardiol ; 29(3): 1419-1429, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-33502690

RESUMEN

BACKGROUND: Myocardial insulin resistance (IR) could be a predictive factor of cardiovascular events. This study aimed to introduce a new method using 123I-6-deoxy-6-iodo-D-glucose (6DIG), a pure tracer of glucose transport, for the assessment of IR using cardiac dynamic nuclear imaging. METHODS: The protocol evaluated first in rat-models consisted in two 6DIG injections and one of insulin associated with planar imaging and blood sampling. Compartmental modeling was used to analyze 6DIG kinetics in basal and insulin conditions and to obtain an index of IR. As a part of a translational approach, a clinical study was then performed in 5 healthy and 6 diabetic volunteers. RESULTS: In rodent models, the method revealed reproducible when performed twice at 7 days apart in the same animal. Rosiglitazone, an insulin-sensitizing drug, induced a significant increase of myocardial IR index in obese Zucker rats from 0.96 ± 0.18 to 2.26 ± 0.44 (P<.05) after 7 days of an oral treatment, and 6DIG IR indexes correlated with the gold standard IR index obtained through the hyperinsulinemic-euglycemic clamp (r=.68, P<.02). In human, a factorial analysis was applied on images to obtain vascular and myocardial kinetics before compartmental modeling. 1.5-fold to 2.2-fold decreases in mean cardiac IR indexes from healthy to diabetic volunteers were observed without reaching statistical significance. CONCLUSIONS: These preclinical results demonstrate the reproducibility and sensibility of this novel imaging methodology. Although this first in-human study showed that this new method could be rapidly performed, larger studies need to be planned in order to confirm its performance.


Asunto(s)
Diabetes Mellitus Tipo 2 , Diabetes Mellitus , Resistencia a la Insulina , Animales , Glucemia , Técnica de Clampeo de la Glucosa , Humanos , Insulina , Ratas , Ratas Zucker , Reproducibilidad de los Resultados
7.
J Nucl Cardiol ; 29(4): 1647-1656, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-33988809

RESUMEN

AIMS: The objective of this study was to determine the accuracy of right ventricular function (RVF) assessed by Cadmium Zinc Telluride ECG-gated SPECT equilibrium radionuclide angiocardiography (CZT-ERNA). METHODS AND RESULTS: Twenty-one consecutive patients with cardiomyopathy (aged 54 ± 19 years; 62% male) were included. RV ejection fraction (EF) and volumes were analyzed by CZT-ERNA and compared with values obtained by cardiac magnetic resonance imaging (CMR). Mean values were not different between CZT-ERNA and MRI for RVEF (48.1 ± 10.4% vs 50.8 ± 10.0%; P = .23). Significant correlations (P < .0001) were observed between CZT-ERNA and MRI for RVEF, RV end-diastolic volume, and end-systolic volume (r = 0.81, r = 0.93, and r = 0.96, respectively). Bland-Altman analysis showed a mean difference (bias) between CZT-ERNA and MRI for RVEF of -2.69% (95% CI - 5.35 to - 0.42) with good agreement between the 2 techniques (limits of agreement, -14.3 to 8.99). Intraobserver and interobserver reproducibility of RVF measured by CZT-ERNA was high. CONCLUSION: CZT-ERNA provides accurate, reproducible assessment of RVF and appears as a good alternative to cardiac magnetic resonance for the evaluation of the magnitude of RVF in patients with cardiomyopathy.


Asunto(s)
Cardiomiopatías , Imagen de Acumulación Sanguínea de Compuerta , Cadmio , Cardiomiopatías/diagnóstico por imagen , Electrocardiografía , Femenino , Imagen de Acumulación Sanguínea de Compuerta/métodos , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Reproducibilidad de los Resultados , Volumen Sistólico , Tomografía Computarizada de Emisión de Fotón Único/métodos , Zinc
8.
Eur J Nucl Med Mol Imaging ; 48(6): 1813-1821, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33219463

RESUMEN

PURPOSE: Risk stratification of patients with type 2 diabetes mellitus (T2D) remains suboptimal. We hypothesized that myocardial perfusion entropy (MPE) quantified from SPECT myocardial perfusion images may provide incremental prognostic value in T2D patients independently from myocardial ischemia. METHODS: T2D patients with very high and high cardiovascular risk were prospectively included (n = 166, 65 ± 12 years). Stress perfusion defect was quantified by visual evaluation of SPECT MPI. SPECT MPI was also used for the quantification of rest and stress MPE. The primary end point was major adverse cardiac events (MACEs) defined as cardiac death, myocardial infarction (MI), and myocardial revascularization > 3 months after SPECT. RESULTS: Forty-four MACEs were observed during a 4.6-year median follow-up. Significant differences in stress MPE were observed between patients with and without MACEs (4.19 ± 0.46 vs. 3.93 ± 0.40; P ≤ .01). By Kaplan-Meier analysis, the risk of MACEs was significantly higher in patients with higher stress MPE (log-rank P ≤ 01). Stress MPE and stress perfusion defect (SSS ≥ 4) were significantly associated with the risk of MACEs (hazard ratio 2.77 and 2.06, respectively, P < .05 for both) after adjustment for clinical and imaging risk predictors as identified from preliminary univariate analysis. MPE demonstrated incremental prognostic value over clinical risk factors, stress test EKG and SSS as evidenced by nested models showing improved Akaike information criterion (AIC), reclassification (global continuous net reclassification improvement [NRI]: 63), global integrated discrimination improvement (IDI: 6%), and discrimination (change in c-statistic: 0.66 vs 0.74). CONCLUSIONS: Stress MPE provided independent and incremental prognostic information for the prediction of MACEs in diabetic patients. TRIAL REGISTRATION NUMBER: NCT02316054 (12/12/2014).


Asunto(s)
Enfermedad de la Arteria Coronaria , Diabetes Mellitus Tipo 2 , Imagen de Perfusión Miocárdica , Diabetes Mellitus Tipo 2/complicaciones , Diabetes Mellitus Tipo 2/diagnóstico por imagen , Entropía , Prueba de Esfuerzo , Humanos , Perfusión , Pronóstico , Medición de Riesgo , Factores de Riesgo , Tomografía Computarizada de Emisión de Fotón Único
9.
Eur J Nucl Med Mol Imaging ; 46(10): 2042-2050, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31321484

RESUMEN

PURPOSE: To determine whether the assessment of regional wall thickening (WT) in addition to myocardial perfusion from stress supine acquisitions could compensate for the lack of prone acquisition and the corresponding decrease in the diagnostic performance of SPECT myocardial perfusion imaging (MPI) in patients with known or suspected coronary artery disease (CAD). METHODS: The study group comprised 41 patients (123 vessels) with known or suspected CAD prospectively recruited for systematic prone and supine 201Tl stress SPECT MPI. The diagnostic performance of SPECT MPI was determined for various image sets including nongated supine images (supine NG), nongated combined prone and supine images (prone and supine NG) and gated supine images, allowing WT evaluation from NG images in addition to perfusion (supine NG + WT) using invasive coronary angiography and fractional flow reserve as the gold standards. RESULTS: The rate of false positives was significantly higher among the supine NG images (20.8%) than among either the prone and supine NG or the supine NG + WT images (3.3% and 2.7%, respectively, P < 0.05 vs. supine NG). Consequently, specificity was higher for the prone and supine NG images than for the supine NG images (96.1% vs. 76.1%, P < 0.01) and was highest for the supine NG + WT images (96.8%, P not significant vs. prone and supine NG), without significant differences in sensitivity (80.0%, 86.6% and 73.3%, respectively, P not significant for all comparisons). CONCLUSION: The diagnostic performance of supine stress SPECT MPI is improved when WT assessment of ischaemic segments is used as an additional diagnostic criterion to values not significantly different from those with combined prone and supine acquisitions.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Imagen de Perfusión Miocárdica/métodos , Posicionamiento del Paciente/métodos , Tomografía Computarizada de Emisión de Fotón Único/métodos , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Imagen de Perfusión Miocárdica/instrumentación , Imagen de Perfusión Miocárdica/normas , Posicionamiento del Paciente/normas , Valor Predictivo de las Pruebas , Posición Prona , Radiofármacos , Semiconductores , Posición Supina , Radioisótopos de Talio , Tomografía Computarizada de Emisión de Fotón Único/instrumentación , Tomografía Computarizada de Emisión de Fotón Único/normas
10.
J Nucl Cardiol ; 26(4): 1269-1279, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-29380286

RESUMEN

BACKGROUND: The aim of this study was to determine the diagnostic accuracy of stress thallium-201/rest technetium-99m-sestamibi sequential dual-isotope high-speed myocardial perfusion imaging (DI-HS-MPI) against invasively determined fractional flow reserve (FFR). METHODS: Fifty-four consecutive patients prospectively underwent DI-HS-MPI before invasive coronary angiography. Perfusion was scored visually by summed stress score on a patient and coronary territory basis. Significant coronary artery disease (CAD) was defined by the presence of ≥ 90% stenosis/occlusion or fractional flow reserve ≤ 0.80 for coronary stenosis ≥ 50%. RESULTS: FFR was measured in 69 of 162 coronary vessels, with 1.28 ± 0.56 vessels assessed/patient. Sensitivity, specificity, and diagnostic accuracy of MPI for the detection of significant CAD were 92.8%, 69.2%, and 81.4%, on a patient basis, and 83.7%, 90.4%, and 88.8% by coronary territory. CONCLUSIONS: DI-HS-MPI accurately detects functionally significant CAD as defined by using FFR.


Asunto(s)
Estenosis Coronaria/diagnóstico por imagen , Imagen de Perfusión Miocárdica , Radiofármacos , Tecnecio Tc 99m Sestamibi , Radioisótopos de Talio , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Angiografía Coronaria , Estenosis Coronaria/fisiopatología , Prueba de Esfuerzo , Femenino , Reserva del Flujo Fraccional Miocárdico , Humanos , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad , Adulto Joven
11.
J Nucl Cardiol ; 25(3): 1017-1022, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29209950

RESUMEN

Coronary microvascular dysfunction has recently emerged as a major independent prognostic factor and can be invasively assessed by coronary flow reserve (CFR) and the index of microvascular resistance (IMR). The incremental prognostic value of myocardial ischemia from SPECT myocardial perfusion imaging (MPI) over clinical characteristics, cardiac risk factors, and stress test data for the prediction of hard cardiac events (myocardial infarction and cardiac death) has been well demonstrated over the last two decades regardless of the absence or presence of epicardial CAD. Recently developed semi-conductor, cardiac-dedicated cameras allow for decreased acquisition times and systematic procubitus and decubitus acquisitions thereby limiting the occurrence of false positives historically attributable to artefactual motion, attenuation, and digestive artifacts. It is therefore likely that pathophysiological causes rather than acquisition artifacts might underlie SPECT perfusion abnormalities. Here, we report four representative examples of patients presenting with ischemia in the setting of no obstructive CAD and normal fractional flow reserve together with elevated IMR and low CFR. The results indicate that ischemia from SPECT MPI could result from microvascular dysfunction in patients without obstructive CAD and should be considered as a prognostic factor for hard cardiac events.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Isquemia Miocárdica/diagnóstico por imagen , Isquemia Miocárdica/etiología , Imagen de Perfusión Miocárdica , Tomografía Computarizada de Emisión de Fotón Único , Adulto , Enfermedad de la Arteria Coronaria/etiología , Enfermedad de la Arteria Coronaria/fisiopatología , Circulación Coronaria/fisiología , Femenino , Reserva del Flujo Fraccional Miocárdico/fisiología , Humanos , Masculino , Microcirculación/fisiología , Persona de Mediana Edad , Isquemia Miocárdica/fisiopatología
12.
J Nucl Cardiol ; 25(2): 483-491, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-27572925

RESUMEN

BACKGROUND: Sympathetic system abnormalities have been reported in sepsis-related cardiac dysfunction. The present study aimed at evaluating the potential of the norepinephrine radiolabeled analogue [123I]-meta-iodobenzylguanidine (123I-MIBG) for the noninvasive assessment of modifications in cardiac sympathetic activity occurring in lipopolysaccharide (LPS)-induced experimental acute sepsis by single-photon emission computed tomographic imaging (SPECT). METHODS AND RESULTS: Sepsis was induced in male Wistar rats by intraperitoneal injection of 10 mg·kg-1 lipopolysaccharide (n = 16), whereas control animals (n = 7) were injected with vehicle (NaCl 0.9%). Echocardiography in LPS-injected animals (n = 8) demonstrated systolic and diastolic cardiac dysfunction. 123I-MIBG was injected 1 hour after LPS or vehicle administration (n = 8 and 7, respectively), and in vivo SPECT imaging was performed early and late (20 and 180 minutes) after tracer injection prior to animal euthanasia and ex vivo assessment of 123I-MIBG biodistribution. Global and 17-segment SPECT image analysis indicated that early 123I-MIBG activity was not affected by LPS treatment, whereas late cardiac tracer activity was significantly decreased in LPS-treated animals. Consequently, the cardiac washout of 123I-MIBG was significantly higher in LPS-treated (63.3% ± 4.0%) than that in control animals (56.7% ± 5.8%) (P < .05). CONCLUSION: Sepsis-induced modifications in cardiac sympathetic nervous system activity were evidenced by noninvasive in vivo 123I-MIBG SPECT imaging.


Asunto(s)
3-Yodobencilguanidina/farmacocinética , Corazón/diagnóstico por imagen , Choque Séptico/fisiopatología , Sistema Nervioso Simpático/fisiopatología , Tomografía Computarizada de Emisión de Fotón Único , Animales , Lipopolisacáridos/química , Masculino , Norepinefrina/sangre , Pronóstico , Ratas , Ratas Wistar , Receptores Adrenérgicos/metabolismo , Distribución Tisular
15.
Int J Mol Sci ; 16(11): 27730-40, 2015 Nov 19.
Artículo en Inglés | MEDLINE | ID: mdl-26610471

RESUMEN

Maurocalcine (MCa) is the first natural cell penetrating peptide to be discovered in animal venom. In addition to the fact that it represents a potent vector for the cell penetration of structurally diverse therapeutic compounds, MCa also displays several distinguishing features that make it a potential peptide of choice for clinical and biotechnological applications. The aim of the present study was to gain new information about the properties of MCa in vivo in order to delineate the future potential applications of this vector. For this purpose, two analogues of this peptide with (Tyr-MCa) and without (Lin-Tyr-MCa) disulfide bridges were synthesized, radiolabeled with (125)I, and their in vitro stabilities were first evaluated in mouse blood. The results indicated that (125)I-Tyr-MCa was stable in vitro and that the disulfide bridges conferred a competitive advantage for the stability of peptide. Following in vivo injection in mice, (125)I-Tyr-MCa targeted peripheral organs with interesting quantitative differences and the main route of peptide elimination was renal.


Asunto(s)
Péptidos de Penetración Celular/farmacocinética , Venenos de Escorpión/farmacocinética , Animales , Péptidos de Penetración Celular/administración & dosificación , Péptidos de Penetración Celular/síntesis química , Cromatografía Líquida de Alta Presión , Estabilidad de Medicamentos , Marcaje Isotópico , Ratones , Tomografía de Emisión de Positrones , Venenos de Escorpión/administración & dosificación , Venenos de Escorpión/síntesis química , Distribución Tisular , Microtomografía por Rayos X
16.
Circ Res ; 110(7): 927-37, 2012 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-22461363

RESUMEN

RATIONALE: A noninvasive tool allowing the detection of vulnerable atherosclerotic plaques is highly needed. By combining nanomolar affinities and fast blood clearance, nanobodies represent potential radiotracers for cardiovascular molecular imaging. Vascular cell adhesion molecule-1 (VCAM1) constitutes a relevant target for molecular imaging of atherosclerotic lesions. OBJECTIVE: We aimed to generate, radiolabel, and evaluate anti-VCAM1 nanobodies for noninvasive detection of atherosclerotic lesions. METHODS AND RESULTS: Ten anti-VCAM1 nanobodies were generated, radiolabeled with technetium-99m, and screened in vitro on mouse and human recombinant VCAM1 proteins and endothelial cells and in vivo in apolipoprotein E-deficient (ApoE(-/-)) mice. A nontargeting control nanobody was used in all experiments to demonstrate specificity. All nanobodies displayed nanomolar affinities for murine VCAM1. Flow cytometry analyses using human human umbilical vein endothelial cells indicated murine and human VCAM1 cross-reactivity for 6 of 10 nanobodies. The lead compound cAbVCAM1-5 was cross-reactive for human VCAM1 and exhibited high lesion-to-control (4.95±0.85), lesion-to-heart (8.30±1.11), and lesion-to-blood ratios (4.32±0.48) (P<0.05 versus control C57Bl/6J mice). Aortic arch atherosclerotic lesions of ApoE(-/-) mice were successfully identified by single-photon emission computed tomography imaging. (99m)Tc-cAbVCAM1-5 binding specificity was demonstrated by in vivo competition experiments. Autoradiography and immunohistochemistry further confirmed cAbVCAM1-5 uptake in VCAM1-positive lesions. CONCLUSIONS: The (99m)Tc-labeled, anti-VCAM1 nanobody cAbVCAM1-5 allowed noninvasive detection of VCAM1 expression and displayed mouse and human cross-reactivity. Therefore, this study demonstrates the potential of nanobodies as a new class of radiotracers for cardiovascular applications. The nanobody technology might evolve into an important research tool for targeted imaging of atherosclerotic lesions and has the potential for fast clinical translation.


Asunto(s)
Aterosclerosis/diagnóstico , Aterosclerosis/metabolismo , Endotelio Vascular/metabolismo , Imagen Molecular/métodos , Trazadores Radiactivos , Molécula 1 de Adhesión Celular Vascular/metabolismo , Animales , Apolipoproteínas E/deficiencia , Apolipoproteínas E/genética , Aterosclerosis/patología , Biomarcadores/metabolismo , Línea Celular , Modelos Animales de Enfermedad , Endotelio Vascular/patología , Femenino , Humanos , Técnicas In Vitro , Ratones , Ratones Noqueados , Radioinmunodetección/métodos , Radiofármacos , Tecnecio
17.
J Nucl Cardiol ; 21(5): 984-92, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24875578

RESUMEN

BACKGROUND: The great clinical potential of myocardial ß-AR imaging has been shown by recent studies evaluating the ß-AR-specific, non-selective agent [(11)C]-CGP12177 in the setting of idiopathic-dilated cardiomyopathy, and myocardial infarction. However, the short half-life of (11)C hampers the potential of [(11)C]-CGP12177 for routine clinical use. AMI9 is an analog of the ß-adrenoceptor ligand practolol that can readily be labeled using radioactive isotopes of iodine. The present study was aimed at characterizing the in vitro, ex vivo, and in vivo ß-AR binding properties of [(125)I]-AMI9. METHODS AND RESULTS: Newborn rat cardiomyocytes were used for saturation and kinetic binding assays as well as for displacement and competition experiments. Isolated perfused rat hearts were used to evaluate the pharmacological activity of AMI9. The in vivo kinetics of [(125)I]-AMI9 were studied using biodistribution experiments in mice. [1(25)I]-AMI9 displayed high specific affinity for ß-AR with no ß-AR subtype selectivity (K D, 5.6 ± 0.3 nM; B max, 231 ± 7 fmol·(mg protein)(-1)). AMI9 potently inhibited the inotropic effects of isoproterenol. The early in vivo cardiac and lung activities of [(125)I]-AMI9 compared favorably with those of the clinically validated tracer CGP12177. CONCLUSION: Iodine-labeled AMI9 is a promising agent for the molecular imaging of myocardial ß-AR density.


Asunto(s)
Imagen Molecular/métodos , Miocardio/metabolismo , Miocitos Cardíacos/metabolismo , Practolol/análogos & derivados , Practolol/farmacocinética , Receptores Adrenérgicos beta/metabolismo , Antagonistas de Receptores Adrenérgicos beta 1/química , Antagonistas de Receptores Adrenérgicos beta 1/farmacocinética , Animales , Animales Recién Nacidos , Células Cultivadas , Evaluación Preclínica de Medicamentos , Corazón/diagnóstico por imagen , Radioisótopos de Yodo/química , Radioisótopos de Yodo/farmacocinética , Marcaje Isotópico/métodos , Tasa de Depuración Metabólica , Ratones , Miocitos Cardíacos/diagnóstico por imagen , Especificidad de Órganos , Cintigrafía , Radiofármacos/síntesis química , Radiofármacos/farmacocinética , Ratas , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Distribución Tisular
19.
Diagnostics (Basel) ; 13(11)2023 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-37296830

RESUMEN

Advances in computer technology and image processing now allow us to obtain from angiographic images a large variety of information on coronary physiology without the use of a guide-wire as a diagnostic information equivalent to FFR and iFR but also information allowing for the performance of a real virtual percutaneous coronary intervention (PCI) and finally the ability to obtain information to optimize the results of PCI. With specific software, it is now possible to have a real upgrading of invasive coronary angiography. In this review, we present the different advances in this field and discuss the future perspectives offered by this technology.

20.
Am J Cardiol ; 205: 207-213, 2023 10 15.
Artículo en Inglés | MEDLINE | ID: mdl-37611412

RESUMEN

The management of anxiety because of upcoming invasive coronary angiography (ICA) remains suboptimal. Previously published studies investigating the potential of virtual reality (VR) for the reduction of anxiety in ICA procedures used a subjective evaluation method. The purpose of this study was to determine whether the use of a VR program before ICA objectively decreases anxiety as assessed by the SD of normal to normal (SDNN). Lower SDNN is associated with worse anxiety. A total of 156 patients referred for ICA after a positive noninvasive test for coronary disease were included in the present randomized study. The interventional group benefited from the use of a VR mask in the transfer room before ICA, whereas the control group underwent the procedure as usual. In both groups, SDNN was measured before ICA. No statistical difference in SDNN was observed between the VR and control groups (45.5 ± 17.8 vs 50.6 ± 19.5, p = 0.12). The preoperative use of a VR mask for anxiolytic purposes in the setting of ICA did not result in a decrease in anxiety.


Asunto(s)
Cardiología , Enfermedad de la Arteria Coronaria , Realidad Virtual , Humanos , Ansiedad , Trastornos de Ansiedad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA