Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Circulation ; 140(23): 1895-1903, 2019 12 03.
Artículo en Inglés | MEDLINE | ID: mdl-31553222

RESUMEN

BACKGROUND: The Absorb everolimus-eluting bioresorbable vascular scaffold (BVS) provides early drug delivery and mechanical support similar to those of metallic drug-eluting stents, followed by complete resorption in ≈3 years with recovery of vascular structure and function. The ABSORB III trial demonstrated noninferior rates of target lesion failure (cardiac death, target vessel myocardial infarction, or ischemia-driven target lesion revascularization) at 1 year with BVS compared with cobalt chromium everolimus-eluting stents. Between 1 and 3 years and cumulative to 3 years, adverse event rates (particularly target vessel myocardial infarction and scaffold thrombosis) were increased after BVS. We sought to assess clinical outcomes after BVS through 5 years, including beyond the 3-year time point of complete scaffold resorption. METHODS: Clinical outcomes from ABSORB III were analyzed by randomized device (intention to treat) cumulative to 5 years and between 3 and 5 years. RESULTS: Rates of target lesion failure, target vessel myocardial infarction, and scaffold thrombosis were increased through the 5-year follow-up with BVS compared with everolimus-eluting stents. However, between 3 and 5 years, reductions in the relative hazards of the BVS compared with everolimus-eluting stents were observed, particularly for target lesion failure (hazard ratio, 0.83 [95% CI, 0.55-1.24] versus 1.35 [95% CI, 1.02-1.78]; Pint=0.052) and scaffold thrombosis (hazard ratio, 0.26 [95% CI, 0.02-2.87] versus 3.23 [95% CI, 1.25-8.30]; Pint=0.056) compared with the 0- to 3-year time period. CONCLUSIONS: In the ABSORB III trial, cumulative 5-year adverse event rates were increased after BVS compared with everolimus-eluting stents. However, the period of excess risk for BVS ended at 3 years, coincident with complete scaffold resorption. CLINICAL TRIAL REGISTRATION: URL: https://clinicaltrials.gov. Unique identifier: NCT01751906.


Asunto(s)
Implantes Absorbibles , Estenosis Coronaria/cirugía , Implantes de Medicamentos , Everolimus/administración & dosificación , Intervención Coronaria Percutánea , Aleaciones de Cromo , Ensayos Clínicos Fase III como Asunto/estadística & datos numéricos , Trombosis Coronaria/epidemiología , Stents Liberadores de Fármacos , Estudios de Equivalencia como Asunto , Everolimus/uso terapéutico , Estudios de Seguimiento , Humanos , Estudios Multicéntricos como Asunto/estadística & datos numéricos , Infarto del Miocardio/epidemiología , Complicaciones Posoperatorias/epidemiología , Diseño de Prótesis , Ensayos Clínicos Controlados Aleatorios como Asunto/estadística & datos numéricos , Método Simple Ciego , Andamios del Tejido , Resultado del Tratamiento
2.
Catheter Cardiovasc Interv ; 94(6): 886-892, 2019 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-31454157

RESUMEN

Patients presenting with hemodynamic instability attributable to left ventricular systolic dysfunction and concomitant severe mitral regurgitation (MR) are increasingly recognized and pose complex management challenges. Surgical therapy is typically precluded owing to prohibitive mortality. The role of percutaneous mechanical circulatory support in such cases is well established; however, such interventions may be neither sufficient to achieve optimal stability nor prove definitive. The advent of novel catheter-based mitral repair modalities now offers primary decisive therapeutic intervention. Three cases of cardiogenic shock with severe MR illustrate the salutary hemodynamic and clinical responses to percutaneous mechanical support and valve repair by mitral clip.


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Corazón Auxiliar , Hemodinámica , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Choque Cardiogénico/terapia , Disfunción Ventricular Izquierda/terapia , Función Ventricular Izquierda , Anciano , Anciano de 80 o más Años , Cateterismo Cardíaco/instrumentación , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Humanos , Masculino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/fisiopatología , Recuperación de la Función , Índice de Severidad de la Enfermedad , Choque Cardiogénico/diagnóstico por imagen , Choque Cardiogénico/fisiopatología , Resultado del Tratamiento , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/fisiopatología
3.
N Engl J Med ; 373(20): 1905-15, 2015 Nov 12.
Artículo en Inglés | MEDLINE | ID: mdl-26457558

RESUMEN

BACKGROUND: In patients with coronary artery disease who receive metallic drug-eluting coronary stents, adverse events such as late target-lesion failure may be related in part to the persistent presence of the metallic stent frame in the coronary-vessel wall. Bioresorbable vascular scaffolds have been developed to attempt to improve long-term outcomes. METHODS: In this large, multicenter, randomized trial, 2008 patients with stable or unstable angina were randomly assigned in a 2:1 ratio to receive an everolimus-eluting bioresorbable vascular (Absorb) scaffold (1322 patients) or an everolimus-eluting cobalt-chromium (Xience) stent (686 patients). The primary end point, which was tested for both noninferiority (margin, 4.5 percentage points for the risk difference) and superiority, was target-lesion failure (cardiac death, target-vessel myocardial infarction, or ischemia-driven target-lesion revascularization) at 1 year. RESULTS: Target-lesion failure at 1 year occurred in 7.8% of patients in the Absorb group and in 6.1% of patients in the Xience group (difference, 1.7 percentage points; 95% confidence interval, -0.5 to 3.9; P=0.007 for noninferiority and P=0.16 for superiority). There was no significant difference between the Absorb group and the Xience group in rates of cardiac death (0.6% and 0.1%, respectively; P=0.29), target-vessel myocardial infarction (6.0% and 4.6%, respectively; P=0.18), or ischemia-driven target-lesion revascularization (3.0% and 2.5%, respectively; P=0.50). Device thrombosis within 1 year occurred in 1.5% of patients in the Absorb group and in 0.7% of patients in the Xience group (P=0.13). CONCLUSIONS: In this large-scale, randomized trial, treatment of noncomplex obstructive coronary artery disease with an everolimus-eluting bioresorbable vascular scaffold, as compared with an everolimus-eluting cobalt-chromium stent, was within the prespecified margin for noninferiority with respect to target-lesion failure at 1 year. (Funded by Abbott Vascular; ABSORB III ClinicalTrials.gov number, NCT01751906.).


Asunto(s)
Implantes Absorbibles , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Everolimus/administración & dosificación , Inmunosupresores/administración & dosificación , Anciano , Angina de Pecho/terapia , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/mortalidad , Reestenosis Coronaria , Stents Liberadores de Fármacos/efectos adversos , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Metales , Persona de Mediana Edad , Diseño de Prótesis
4.
JAMA ; 319(1): 27-37, 2018 01 02.
Artículo en Inglés | MEDLINE | ID: mdl-29297076

RESUMEN

Importance: Transcatheter aortic valve replacement (TAVR) is established for selected patients with severe aortic stenosis. However, limitations such as suboptimal deployment, conduction disturbances, and paravalvular leak occur. Objective: To evaluate if a mechanically expanded valve (MEV) is noninferior to an approved self-expanding valve (SEV) in high-risk patients with aortic stenosis undergoing TAVR. Design, Setting, and Participants: The REPRISE III trial was conducted in 912 patients with high or extreme risk and severe, symptomatic aortic stenosis at 55 centers in North America, Europe, and Australia between September 22, 2014, and December 24, 2015, with final follow-up on March 8, 2017. Interventions: Participants were randomized in a 2:1 ratio to receive either an MEV (n = 607) or an SEV (n = 305). Main Outcomes and Measures: The primary safety end point was the 30-day composite of all-cause mortality, stroke, life-threatening or major bleeding, stage 2/3 acute kidney injury, and major vascular complications tested for noninferiority (margin, 10.5%). The primary effectiveness end point was the 1-year composite of all-cause mortality, disabling stroke, and moderate or greater paravalvular leak tested for noninferiority (margin, 9.5%). If noninferiority criteria were met, the secondary end point of 1-year moderate or greater paravalvular leak was tested for superiority in the full analysis data set. Results: Among 912 randomized patients (mean age, 82.8 [SD, 7.3] years; 463 [51%] women; predicted risk of mortality, 6.8%), 874 (96%) were evaluable at 1 year. The primary safety composite end point at 30 days occurred in 20.3% of MEV patients and 17.2% of SEV patients (difference, 3.1%; Farrington-Manning 97.5% CI, -∞ to 8.3%; P = .003 for noninferiority). At 1 year, the primary effectiveness composite end point occurred in 15.4% with the MEV and 25.5% with the SEV (difference, -10.1%; Farrington-Manning 97.5% CI, -∞ to -4.4%; P<.001 for noninferiority). The 1-year rates of moderate or severe paravalvular leak were 0.9% for the MEV and 6.8% for the SEV (difference, -6.1%; 95% CI, -9.6% to -2.6%; P < .001). The superiority analysis for primary effectiveness was statistically significant (difference, -10.2%; 95% CI, -16.3% to -4.0%; P < .001). The MEV had higher rates of new pacemaker implants (35.5% vs 19.6%; P < .001) and valve thrombosis (1.5% vs 0%) but lower rates of repeat procedures (0.2% vs 2.0%), valve-in-valve deployments (0% vs 3.7%), and valve malpositioning (0% vs 2.7%). Conclusions and Relevance: Among high-risk patients with aortic stenosis, use of the MEV compared with the SEV did not result in inferior outcomes for the primary safety end point or the primary effectiveness end point. These findings suggest that the MEV may be a useful addition for TAVR in high-risk patients. Trial Registration: ClinicalTrials.gov Identifier: NCT02202434.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/mortalidad , Bioprótesis , Enfermedades Cardiovasculares/etiología , Enfermedades Cardiovasculares/mortalidad , Femenino , Estudios de Seguimiento , Humanos , Masculino , Complicaciones Posoperatorias/etiología , Diseño de Prótesis , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
6.
Catheter Cardiovasc Interv ; 88(S1): 21-30, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27797464

RESUMEN

The permanent metal prosthesis common to bare metal stents (BMS) as well as both first- and second-generation drug-eluting stents (DES) following treatment of coronary artery disease represents a long-lasting substrate for late adverse coronary events including restenosis, thrombosis, and neoatherosclerosis. Following resorbtion, bioresorbable scaffolds (BRS) may eliminate this nidus and improve late outcomes through restoration of the vessel to more normal vascular structure and function. BRS represents a single platform which incorporates the mechanical features of metallic stents to provide safe and effective revascularization, suppression of restenosis and prevention of constrictive remodeling with long-term restoration of the treated vessel to a more natural state. The landscape of BRS is rapidly evolving with new materials which target various performance goals for the duration of vascular support and polymer resorption time. The Absorb bioresorbable vascular scaffold (Absorb BVS), recently approved by United States Food and Drug Administration, has extensive clinical evidence to date in support of its clinical efficacy and safety. Recently published data from well-executed randomized clinical trials (RCTs) as part of the ABSORB Clinical development program along with other investigator-initiated trials provide insights into the safety and performance of this device in patients with de novo coronary lesions as well in the setting of ST-segment elevation myocardial infarction (STEMI). This review provides a comprehensive, outcomes based understanding of the available evidence from RCTs that offer head-to-head comparisons of Absorb BVS with metallic everolimus-eluting stents (EES). © 2016 Wiley Periodicals, Inc.


Asunto(s)
Implantes Absorbibles , Enfermedad de la Arteria Coronaria/cirugía , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/métodos , Andamios del Tejido , Humanos , Diseño de Prótesis
7.
Catheter Cardiovasc Interv ; 88(6): 899-901, 2016 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-27545489

RESUMEN

Drug eluting stents are considered the "gold standard" for the percutaneous treatment of coronary artery disease. Recent publications have suggested that a reasonable alternative, in well selected cases, may be the ABSORBTM bioresorbable vascular scaffold (BVS) stent. © 2016 Wiley Periodicals, Inc.


Asunto(s)
Implantes Absorbibles , Enfermedad de la Arteria Coronaria/cirugía , Vasos Coronarios/cirugía , Aprobación de Drogas , Stents Liberadores de Fármacos , Andamios del Tejido , Anciano , Anciano de 80 o más Años , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico , Vasos Coronarios/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Estados Unidos , United States Food and Drug Administration
10.
Catheter Cardiovasc Interv ; 86(4): 664-77, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26386235

RESUMEN

The advent of fully bioresorbable stent technology and specifically the ABSORB™, a bioresorbable vascular scaffold (BVS) stent, is heralded as breakthrough technology in the current era of percutaneous coronary interventions. This article reviews the current understanding of this technology along with the clinical evidence from trials and registries of ABSORB BVS that included patients with both simple as well as more complex "real-world" coronary lesions. In addition, considering the current limitations of this device-mostly associated with the mechanical properties of the polymeric scaffold structure-a review of guidelines on successful implantation of the ABSORB BVS is presented. Although expert feedback suggests extensive use of this device in routine clinical practice outside the United States despite a paucity of data on long-term safety in this setting, attention to procedural details and implantation technique is obligatory to achieve optimal clinical outcomes.


Asunto(s)
Implantes Absorbibles , Angioplastia Coronaria con Balón/métodos , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Angioplastia Coronaria con Balón/mortalidad , Angiografía Coronaria/métodos , Puente de Arteria Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/cirugía , Everolimus/farmacología , Medicina Basada en la Evidencia , Femenino , Estudios de Seguimiento , Humanos , Masculino , Diseño de Prótesis , Medición de Riesgo , Índice de Severidad de la Enfermedad , Sirolimus/farmacología , Análisis de Supervivencia , Factores de Tiempo , Andamios del Tejido , Resultado del Tratamiento
11.
J Interv Cardiol ; 28(4): 326-38, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26077351

RESUMEN

For many years, coronary artery bypass graft surgery has been the gold standard for revascularization of patients with left main disease; however, increasing evidence suggests that percutaneous coronary intervention with drug-eluting stents may be an acceptable alternative or even preferred in select cases. This review will present clinical evidence examining the outcomes of drug-eluting stents compared to coronary artery bypass graft surgery for unprotected left main coronary artery disease and discuss the anatomic factors, patient variables, and clinical strategies that may dictate choice of revascularization modality for patients with left main disease. If percutaneous coronary intervention is selected to treat unprotected left main disease, meticulous technique is essential to optimize outcomes, including use of procedural physiology and imaging guidance, optimal stent and adjunct pharmacology use, and expert management of the distal bifurcation. Finally, issues of equipoise and uncertainty are identified, representing areas for future investigation.


Asunto(s)
Enfermedad de la Arteria Coronaria/cirugía , Selección de Paciente , Anticoagulantes/uso terapéutico , Ensayos Clínicos como Asunto , Puente de Arteria Coronaria , Estenosis Coronaria/diagnóstico por imagen , Stents Liberadores de Fármacos , Humanos , Inhibidores de Hidroximetilglutaril-CoA Reductasas/administración & dosificación , Contrapulsador Intraaórtico , Intervención Coronaria Percutánea , Inhibidores de Agregación Plaquetaria/uso terapéutico , Índice de Severidad de la Enfermedad , Ultrasonografía
12.
Cardiovasc Revasc Med ; 64: 70-75, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38538447

RESUMEN

OBJECTIVES: This study evaluated the efficacy of a novel comprehensive shield designed to minimize radiation exposure (RE) to Physicians performing coronary and structural heart procedures. BACKGROUND: The Protego™ radiation shielding system (Image Diagnostics Inc., Fitchburg, Ma) is designed to provide comprehensive protection from RE and has been State certified sufficient to allow operators to perform procedures without orthopedically burdensome lead aprons. METHODS: This single center two-group cohort study assessed the efficacy of this shield in a large number of cardiac procedures (coronary and structural), comparing operator RE compared to standard protection methods (personal lead apparel and "drop down" shield). RESULTS: The Protego™ system reduced operator RE by 99 % compared to Standard Protection. RE was significantly lower at both "Head" level by thyroid median dose 0.0 (0.0, 0,0) vs 5.7 (2.9, 8.2) µSv (p < 0.001), as well as waist dose 0.0 (0.0, 0.0) vs 10.0 (5.0, 16.6) µSv (p < 0.001). "Zero" Total RE was documented by Raysafe™ in 64 % (n = 32) of TAVR cases and 73.2 % (n = 183) of the coronary cases utilizing Protego™. In contrast, standard protection did not achieve "Zero" exposure in a single case. These dramatic differences in RE were achieved despite higher fluoroscopy times in the Protego™ arm (11.9 ± 8.6 vs 14.3 ± 12.5 min, p = 0.015). Per case procedural exposure measured by Dose Area Product was higher in the Protego™ group compared to standard protection (115.4 ± 139.2 vs 74.9 ± 69.3, p < 0.001). CONCLUSION: The Protego™ shield provides total body RE protection for operators performing both coronary and structural heart procedures. This shield allows procedural performance without the need for personal lead aprons and has potential to reduce catheterization laboratory occupational health hazards.


Asunto(s)
Exposición Profesional , Salud Laboral , Dosis de Radiación , Exposición a la Radiación , Protección Radiológica , Radiografía Intervencional , Humanos , Exposición Profesional/prevención & control , Exposición Profesional/efectos adversos , Exposición a la Radiación/prevención & control , Exposición a la Radiación/efectos adversos , Protección Radiológica/instrumentación , Radiografía Intervencional/efectos adversos , Radiografía Intervencional/normas , Factores de Riesgo , Medición de Riesgo , Traumatismos por Radiación/prevención & control , Traumatismos por Radiación/etiología , Diseño de Equipo , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Masculino , Monitoreo de Radiación , Femenino
13.
J Interv Cardiol ; 25(4): 337-43, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22726133

RESUMEN

The Xience Side Branch Access (SBA) stent is an everolimus-eluting stent designed specifically for branching coronary geometry, providing wire access into the side branch (SB) regardless of the planned treatment strategy. The stent is delivered via a low-profile, dual-lumen, and single-tip catheter. A single inflation deploys the stent in the main branch (MB) and opens a portal into the SB. It is through this portal opening, allowing wire access into the SB, that this device differentiates itself from certain other dedicated bifurcation devices currently in various stages of development and testing. The Xience SBA stent was compared with a standard Multi-Link Vision® stent using a provisional T-stenting strategy in an ovine beating heart model. The Xience SBA stent tended to be deployed with less mean contrast usage (21.05 vs. 43.23 mL; P = 0.09), shorter fluoroscopy time (2.55 vs. 4.52 minute; P = 0.12), and lower rates of guidewire entanglement (16% vs. 100%) compared with the workhorse stent. As a result, the total procedure time with the Xience SBA stent was significantly shorter than that with the standard stent (5.46 vs. 8.65 minute; P = 0.01). The Xience SBA stent was also evaluated by four recently trained interventionalists who had no previous experience with the device. Using a perfused synthetic heart model, SB access time was reduced by 54%, average fluoroscopy time was reduced by 46%, and average contrast usage was lowered by 39% with the Xience SBA compared with the standard stent. Initial experience in the ovine model suggests that the Xience SBA stent is also amenable for use in distal left main coronary artery disease, regardless of whether it is deployed in the left ascending coronary artery or left circumflex artery and the portal opened in the opposing vessel. On the basis of these experimental results, the Xience SBA stent is an easy to use and versatile device for the purpose of SB access and potentially for the treatment of bifurcation coronary artery lesions.


Asunto(s)
Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Animales , Angiografía Coronaria , Everolimus , Inmunosupresores/uso terapéutico , Ovinos , Sirolimus/análogos & derivados , Sirolimus/uso terapéutico , Factores de Tiempo , Resultado del Tratamiento
14.
JAMA Netw Open ; 5(10): e2238792, 2022 10 03.
Artículo en Inglés | MEDLINE | ID: mdl-36301543

RESUMEN

Importance: Long-term follow-up after transcatheter aortic valve replacement (TAVR) is of interest given that longitudinal data on mortality and durability of transcatheter heart valves are limited. The REPRISE III (Repositionable Percutaneous Replacement of Stenotic Aortic Valve Through Implantation of Lotus Valve System-Randomized Clinical Evaluation) randomized clinical trial compared the mechanically expanded Lotus valve with the self-expanding CoreValve/EvolutR TAVR platforms. Objective: To describe the final 5-year outcomes of the REPRISE III trial. Design, Setting, and Participants: This prespecified secondary analysis assessed the final 5-year clinical, functional, and echocardiographic outcomes of 912 patients from the REPRISE III trial, which was conducted at 55 centers in North America, Europe, and Australia between September 22, 2014, and December 24, 2015. Patients had high risk for aortic stenosis or severe or symptomatic aortic stenosis. Data were analyzed from September 22, 2014, to May 21, 2021. Intervention: Lotus valve or CoreValve/EvolutR TAVR platforms. Main Outcomes and Measures: Valve Academic Research Consortium-2 end points, hemodynamic measures, functional status, and health status were examined through the 5-year follow-up. Results: A total of 912 patients (mean [SD] age, 82.8 [7.3] years; 463 women [50.8%]) were randomized to either the Lotus valve group (n = 607) or CoreValve/EvolutR group (n = 305), with a baseline Society of Thoracic Surgeons risk score of 6.8%. Clinical follow-up data from the REPRISE III trial were available for 581 patients (95.7%) in the Lotus valve group and 285 patients (93.4%) in the CoreValve/EvolutR group. At 5 years, the cumulative event rate for all-cause mortality was 50.9% in the Lotus valve group vs 52.8% in the CoreValve/EvolutR group (P = .59). Disabling stroke was less frequent with the Lotus valve vs CoreValve/EvolutR (cumulative event rates, 8.3% vs 12.2%; P = .04), whereas the cumulative event rates for overall stroke were similar in both groups (14.1% vs 15.3%; P = .38). Insertion of a new permanent pacemaker (38.9% vs 27.3%; P < .001) and detection of prosthetic aortic valve thrombosis (5.8% vs 1.8%; P = .007) were more common in the Lotus valve group than in the CoreValve/EvolutR group. A smaller proportion of patients who received the Lotus valve experienced valve malpositioning (0% vs 2.6%; P < .001) and required the use of a second valve (1.0% vs 3.8%; P < .001) during the procedure compared with those who received the CoreValve/EvolutR. Compared with the Lotus valve group, the CoreValve/EvolutR group had a significantly lower mean (SD) aortic gradient (7.8 [4.2] mm Hg vs 12.6 [6.7] mm Hg; P < .001) and larger valve areas (1.57 [0.56] cm2 vs 1.42 [0.42] cm2; P = .10). After 5 years, the proportion of patients with moderate or greater paravalvular leak was not significantly higher with the CoreValve/EvolutR than with the Lotus valve (1.9% vs 0%; P = .31); however, the proportion of patients with mild paravalvular leak was higher in the CoreValve/EvolutR group compared with the Lotus valve group (23.1% vs 7.8%; P = .006). Long-term, similar improvements in New York Heart Association class and Kansas City Cardiomyopathy Questionnaire score were observed in both groups. Conclusions and Relevance: The REPRISE III trial found that, at 5 years, the clinical outcomes of the Lotus valve were comparable to those of the CoreValve/EvolutR and that the Lotus valve was safe and effective. Trial Registration: ClinicalTrials.gov Identifier: NCT02202434.


Asunto(s)
Estenosis de la Válvula Aórtica , Accidente Cerebrovascular , Trombosis , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Anciano de 80 o más Años , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/cirugía , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/cirugía , Accidente Cerebrovascular/etiología
15.
Indian Heart J ; 73(2): 149-155, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33865510

RESUMEN

Transradial intervention (TRI) was first introduced by Lucien Campeau in 1989 and since then has created a lasting impact in the field of interventional cardiology. Several studies have demonstrated that TRI is associated with fewer vascular site complications, offer earlier ambulation and greater post-procedural comfort. Patients presenting with ST Segment Elevation Myocardial Infarction (STEMI) have experienced survival benefit and higher quality-of-life metrics as well with TRI. While both the updated scientific statement by the American Heart Association and the 2017 European Society of Cardiology guidelines recommend a "radial first" approach there appears to be a lag in physicians adapting TRI as the preferred vascular access. We present a review focusing on identification and management of TRA related challenges and complications using a systematic algorithmic approach.


Asunto(s)
Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST , Algoritmos , Arteria Femoral , Humanos , Arteria Radial , Resultado del Tratamiento
16.
Rev Cardiovasc Med ; 11 Suppl 1: S27-37, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-20495523

RESUMEN

Coronary bifurcation lesions are a common challenge for interventional cardiologists, for which there is no clear consensus on optimal treatment. The side branch (SB) ostium has become the focus of new treatment strategies because it is a common site of restenosis. In comparison, restenosis and reintervention rates in the main branch are acceptably low, reflecting improved techniques and greater use of drug-eluting stents. Many different companies are evaluating dedicated bifurcation devices that are designed to offer easy access to the SB, but that differ in concept and in the degree of coverage provided to the SB ostium. Some are bare metal stents, whereas several are drug-eluting iterations based on platforms used in conventional stents. The promise of these dedicated bifurcation devices is illustrated by early results from single-arm clinical studies.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Enfermedad de la Arteria Coronaria/terapia , Stents , Angioplastia Coronaria con Balón/efectos adversos , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico , Reestenosis Coronaria/etiología , Reestenosis Coronaria/prevención & control , Stents Liberadores de Fármacos , Humanos , Metales , Diseño de Prótesis , Resultado del Tratamiento
17.
J Am Heart Assoc ; 9(17): e017075, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32856530

RESUMEN

Background Gait speed is a reliable measure of physical function and frailty in patients with aortic stenosis undergoing transcatheter aortic valve replacement (TAVR). Slow gait speed pre-TAVR predicts worse clinical outcomes post-TAVR. The consequences of improved versus worsened physical function post-TAVR are unknown. Methods and Results The REPRISE III (Repositionable Percutaneous Replacement of Stenotic Aortic Valve Through Implantation of Lotus Valve System-Randomized Clinical Evaluation) trial randomized high/extreme risk patients to receive a mechanically-expanded or self-expanding transcatheter heart valve. Of 874 patients who underwent TAVR, 576 with complete data at baseline and 1 year were included in this analysis. Slow gait speed in the 5-m walk test was defined as <0.83 m/s. A clinically meaningful improvement (≥0.1 m/s) in gait speed 1 year after TAVR occurred in 39% of patients, 35% exhibited no change, and 26% declined (≥0.1 m/s). Among groups defined by baseline/1-year post-TAVR gait speeds, 1- to 2-year mortality or hospitalization rates were as follows: 6.6% (normal/normal), 8.0% (slow/normal), 20.9% (normal/slow), and 21.5% (slow/slow). After adjustment, slow gait speed at 1 year (regardless of baseline speed) was associated with a 3.5-fold increase in death/hospitalization between 1 and 2 years compared with those with normal baseline/1-year gait speed. Patients whose slow gait speed normalized at 1 year had no increased risk. One-year, but not baseline, gait speed was associated with death or hospitalization between 1 and 2 years (adjusted hazard ratio, 0.83 per 0.1 m/s faster gait; 95% CI, 0.74-0.93, P=0.001). Conclusions Marked heterogeneity exists in the trajectory of physical function after TAVR and this, more than baseline function, has clinical consequences. Identifying and optimizing factors associated with physical resilience after TAVR may improve outcomes. Registration URL: https://www.clini​caltr​ials.gov; Unique identifier: NCT02202434.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Fragilidad/complicaciones , Aptitud Física/fisiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Velocidad al Caminar/fisiología , Anciano , Anciano de 80 o más Años , Estudios de Casos y Controles , Femenino , Fragilidad/epidemiología , Prótesis Valvulares Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Hospitalización/estadística & datos numéricos , Humanos , Masculino , Complicaciones Posoperatorias/mortalidad , Prevalencia , Modelos de Riesgos Proporcionales , Resiliencia Psicológica , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
18.
J Am Coll Cardiol ; 75(12): 1371-1382, 2020 03 31.
Artículo en Inglés | MEDLINE | ID: mdl-32216905

RESUMEN

BACKGROUND: Autopsy studies suggest that implanting stents in lipid-rich plaque (LRP) may be associated with adverse outcomes. OBJECTIVES: The purpose of this study was to evaluate the association between LRP detected by near-infrared spectroscopy (NIRS) and clinical outcomes in patients with coronary artery disease treated with contemporary drug-eluting stents. METHODS: In this prospective, multicenter registry, NIRS was performed in patients undergoing coronary angiography and possible percutaneous coronary intervention (PCI). Lipid core burden index (LCBI) was calculated as the fraction of pixels with the probability of LRP >0.6 within a region of interest. MaxLCBI4mm was defined as the maximum LCBI within any 4-mm-long segment. Major adverse cardiac events (MACE) included cardiac death, myocardial infarction, definite or probable stent thrombosis, or unplanned revascularization or rehospitalization for progressive angina or unstable angina. Events were subcategorized as culprit (treated) lesion-related, nonculprit (untreated) lesion-related, or indeterminate. RESULTS: Among 1,999 patients who were enrolled in the COLOR (Chemometric Observations of Lipid Core Plaques of Interest in Native Coronary Arteries Registry), PCI was performed in 1,621 patients and MACE occurred in 18.0% of patients, of which 8.3% were culprit lesion-related, 10.7% were nonculprit lesion-related, and 3.1% were indeterminate during 2-year follow-up. Complications from NIRS imaging occurred in 9 patients (0.45%), which resulted in 1 peri-procedural myocardial infarction and 1 emergent coronary bypass. Pre-PCI NIRS imaging was obtained in 1,189 patients, and the 2-year rate of culprit lesion-related MACE was not significantly associated with maxLCBI4mm (hazard ratio of maxLCBI4mm per 100: 1.06; 95% confidence interval: 0.96 to 1.17; p = 0.28) after adjusting clinical and procedural factors. CONCLUSIONS: Following PCI with contemporary drug-eluting stents, stent implantation in NIRS-defined LRPs was not associated with increased periprocedural or late adverse outcomes compared with those without significant lipid.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/metabolismo , Stents Liberadores de Fármacos/tendencias , Intervención Coronaria Percutánea/tendencias , Placa Aterosclerótica/diagnóstico por imagen , Placa Aterosclerótica/metabolismo , Anciano , Stents Liberadores de Fármacos/efectos adversos , Femenino , Estudios de Seguimiento , Humanos , Metabolismo de los Lípidos/fisiología , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Estudios Prospectivos , Sistema de Registros , Espectroscopía Infrarroja Corta/tendencias , Resultado del Tratamiento
20.
J Interv Cardiol ; 22(6): 537-46, 2009 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-19912465

RESUMEN

BACKGROUND: Provisional T-stenting is a widely used strategy for the treatment of coronary artery bifurcation lesions. However, the use of conventional stents in this setting is limited by multiple factors; this includes technical considerations such as wire wrap when accessing the involved vessel, and stent overlap at or near the carina of the lesion. In addition, current slotted tube stent technology tends to be associated with gaps in the coverage of the side branch ostium, which may result in restenosis in that segment of the lesion. The Pathfinder device, now more commonly referred to as the Xience Side Branch Access System (Xience SBA) is a drug-eluting stent (DES) designed specifically to assist in the treatment of bifurcation lesions by allowing wire access into the side branch, irrespective of the treatment strategy to be employed. METHODS: The Xience SBA drug-eluting stent was compared with the standard Vision coronary stent system using a provisional T-stenting strategy in a perfused synthetic model of the coronary vasculature with side branch angulations of 30 degrees , 50 degrees , 70 degrees , and 90 degrees . Stent delivery was performed under fluoroscopic guidance. Following the procedure, high-resolution 2D Faxitron imaging was used to evaluate deployment accuracy of the side branch stent relative to the main branch stent. RESULTS: Deployment of the Xience SBA was accomplished in the same total time as the standard stents in a provisional T-stenting approach (14.9 vs. 14.6 minutes). However, the time required to achieve stent deployment in the main branch was less with the Xience SBA (4.0 vs. 6.6 minutes), and as a result, total contrast usage (49.4 vs. 69.4 cm(3)) and fluoroscopy time (5.1 vs. 6.2 minutes) was lower. Additionally, the Xience SBA had a lower incidence of wire wrap (22% vs. 89%) and less distal protrusion of the side branch stent into the main branch (0.54 vs. 1.21 mm). Significant gaps in ostial side branch coverage were not seen in either group. CONCLUSIONS: The Xience Side Branch Access DES is a viable device for consistently accessing coronary bifurcation lesions; it allows for easy wire access into the side branch. This may assist the operator in overcoming those well-recognized limitations associated with use of standard one- or two-stent strategies. In this perfused synthetic coronary model, Xience SBA deployment required less contrast usage and shorter fluoroscopy times. Further testing of this device is warranted.


Asunto(s)
Enfermedad de la Arteria Coronaria/terapia , Vasos Coronarios/patología , Stents Liberadores de Fármacos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Trombosis Coronaria/prevención & control , Fluoroscopía , Hemodinámica , Humanos , Modelos Anatómicos , Proyectos Piloto , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA