RESUMEN

An analytical method based on capillary electrophoresis (CE) using capacitively coupled contactless conductivity detection (C4 D) was developed and validated for fast, straightforward, and reliable determination of lactate in artificial and human sweat samples. The background electrolyte was composed of equimolar concentrations (10 mmol/L) of 2-(N-morpholino)ethanesulfonic acid and histidine, with 0.2 mmol/L of cetyltrimethylammonium bromide as electroosmotic flow inverter. The limit of detection and quantification were 3.1 and 10.3 µmol/L, respectively. Recoveries in the 97 to 118% range were obtained using sweat samples spiked with lactate at three concentration levels, indicating an acceptable accuracy. The intraday and interday precisions were 1.49 and 7.08%, respectively. The proposed CE-C4 D method can be a starting point for monitoring lactate concentrations in sweat samples for diagnostics, physiological studies, and sports performance assessment applications.


Asunto(s)
Ácidos Alcanesulfónicos , Ácido Láctico , Morfolinas , Sudor , Humanos , Cetrimonio , Electroforesis Capilar/métodos , Conductividad Eléctrica
2.
Electrophoresis ; 2024 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-38607366

RESUMEN

This work describes a novel analytical method using capillary electrophoresis (CE) with capacitively coupled contactless conductivity detection (C4D) for simultaneous, simple, and rapid determination of three inorganic phosphates (orthophosphate, pyrophosphate, and tripolyphosphate) widely used as food additives and in pharmaceutical formulations. A background electrolyte composed of 0.5 mol L-1 acetic acid provided fast separation (around 3.0 min) and good separation efficiency and peak resolution. Linearity in the concentration range of 10-500 mg L-1 was confirmed by the coefficients of determination (R2) higher than 0.99. The limits of detection varied from 0.41 to 0.58 mg L-1. The accuracy of the proposed method was assessed by recovery tests conducted at three concentration levels in tap water samples, food, and personal hygiene products. Recovery values varying from 81% to 118% were achieved, indicating an acceptable accuracy. The proposed CE-C4D successfully determined the three inorganic phosphates in the analyzed samples.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA