RESUMEN
Right ventricle-pulmonary artery (RV-PA) coupling has been linked to clinical outcomes in patients with severe aortic stenosis (AS) undergoing transcatheter valve implantation (TAVI). However, the best timing for prognostic assessment remains uncertain. Our aim was to determine the impact of RV longitudinal function parameters and RV-PA coupling on mortality in patients undergoing TAVI. Retrospective, single center, analysis including patients with AS who underwent TAVI between 2007 and 2021. Echocardiographic evaluation was performed before, shortly after the procedure, and during follow-up. RV-PA uncoupling was defined as a TAPSE/PASP ratio<0.55 (severe RV uncoupling was defined as TAPSE/PASP ratio<0.32. The effect of RV parameters on all-cause mortality up to 12 months was assessed. Among the 577 patients included, pre-procedural TAPSE/PASP ratio data were available for 205. RV-PA uncoupling was present in 113 patients (55.1%), with severe uncoupling observed in 31 (15.1%). Within the first 12 months after TAVI, 51 patients (9%) died. Severe RV-PA uncoupling was associated with mortality in univariable Cox regression; however, this association was lost after adjusting for EuroSCORE II. A significant association was found between the TAPSE/PASP ratio (per 0.1-unit increase) after the procedure and the primary endpoint (HR: 0.73; 95% CI: 0.56, 0.97; p=0.029). Higher postprocedural PASP (HR: 1.04; 95% CI: 1.02, 1.06; p<0.001 was also associated with all-cause mortality. V-PA uncoupling and PASP after TAVI are associated with all-cause mortality in patients and may be valuable for patient selection and for planning post-procedural care.
Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Arteria Pulmonar , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter , Función Ventricular Derecha , Humanos , Masculino , Estudios Retrospectivos , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Arteria Pulmonar/fisiopatología , Arteria Pulmonar/diagnóstico por imagen , Anciano , Resultado del Tratamiento , Anciano de 80 o más Años , Factores de Tiempo , Factores de Riesgo , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Válvula Aórtica/cirugía , Medición de Riesgo , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/fisiopatologíaRESUMEN
Transcatheter valve-in-valve implantation for degenerated bioprostheses is an appealing alternative to reoperation in high-risk patients, and is technically feasible in both aortic and mitral positions. However, concurrent aortic and mitral transcatheter valve-in-valve procedures are seldom described. We aim to report our first case of double transapical valve-in-valve procedure for concomitant malfunction of aortic and mitral bioprostheses, in the same session.
Asunto(s)
Válvula Aórtica/cirugía , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas , Válvula Mitral/cirugía , Anciano , Diseño de Equipo , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Humanos , Masculino , Falla de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter/instrumentaciónRESUMEN
INTRODUCTION AND OBJECTIVE: Coronary artery disease is highly prevalent among patients with severe aortic stenosis who undergo transcatheter aortic valve replacement (TAVR). As indications for TAVR are now expanding to younger and lower-risk patients, the need for coronary angiography (CA) and percutaneous coronary intervention (PCI) during their lifetime is expected to increase. The objective of our study was to assess the need for CA and the feasibility of re-engaging the coronary ostia after TAVR. METHODS: We performed a retrospective analysis of 853 consecutive patients undergoing TAVR between August 2007 and December 2020. Patients who needed CA after TAVR were selected. The primary endpoint was the rate of successful coronary ostia cannulation after TAVR. RESULTS: Of a total of 31 CAs in 28 patients (3.5% of 810 patients analyzed: 57% male, age 77.8±7.0 years) performed after TAVR, 28 (90%) met the primary endpoint and in three cannulation was semi-selective. All failed selective coronary ostia cannulations occurred in patients with a self-expanding valve. Sixteen (52%) also had indication for PCI, which was successfully performed in all. The main indication for CA was non-ST-elevation acute coronary syndrome (35%, n=11). Two cases of primary PCI occurred without delay. There were no complications reported during or after the procedure. CONCLUSION: Although CA was rarely needed in patients after TAVR, selective diagnostic CA was possible in the overwhelming majority of patients. PCI was performed successfully in all cases, without complications.
Asunto(s)
Estenosis de la Válvula Aórtica , Intervención Coronaria Percutánea , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Anciano , Anciano de 80 o más Años , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Angiografía Coronaria , Intervención Coronaria Percutánea/métodos , Estudios Retrospectivos , Estudios de Factibilidad , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Válvula Aórtica/cirugía , Factores de RiesgoRESUMEN
Type-A aortic dissection is a rare and often fatal complication following coronary artery bypass surgery (CABG). Corrective surgery seldom improves patient outcome. This report reviews and discusses endoprosthetic correction of type-A aortic dissection. A case of a transluminal correction of acute type-A aortic dissection one year after CABG in a 66-year-old male with a history of ischemic and severely compromised left ventricular function is presented. A prosthesis originally designed for the abdominal aorta was successfully used. Regular follow-up was performed and nearly 3 years post prosthesis implantation the patient is stable in New York Heart Association class II. To the authors' knowledge there are no other literature reports of endoprosthetic correction of a type-A aortic dissection in the context of CABG with saphenous grafts.
Asunto(s)
Aneurisma de la Aorta/cirugía , Disección Aórtica/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Puente de Arteria Coronaria/efectos adversos , Procedimientos Endovasculares/instrumentación , Stents , Anciano , Disección Aórtica/diagnóstico , Disección Aórtica/etiología , Aneurisma de la Aorta/diagnóstico , Aneurisma de la Aorta/etiología , Aortografía/métodos , Ecocardiografía Transesofágica , Humanos , Masculino , Tomografía Computarizada Multidetector , Diseño de Prótesis , Factores de Tiempo , Resultado del TratamientoRESUMEN
Thoracic endovascular aortic repair (TEVAR) is a minimally invasive technique which is increasingly used in different thoracic aortic pathologies such as aortic aneurysm, complicated type B aortic dissection, aortic trauma, intramural hematoma and penetrating aortic ulcer. In this paper we discuss the main indications for endovascular stent-grafts in the treatment of thoracic aortic disease, based on three cases in which this procedure was used for three different conditions: degenerative aneurysm, complicated type B dissection and post-traumatic injury. These case reports add to the evidence that TEVAR is a safe and feasible therapeutic alternative in selected patients with thoracic aortic disease, improving aortic remodeling, with relatively low morbidity and mortality. The main complications and difficulties related to the procedure are also discussed.
Asunto(s)
Enfermedades de la Aorta/cirugía , Prótesis Vascular , Procedimientos Endovasculares , Stents , Anciano de 80 o más Años , Aorta Torácica , Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/epidemiología , Stents/efectos adversos , Adulto JovenRESUMEN
OBJECTIVES: Elderly patients show a higher incidence of ischemic and bleeding events after percutaneous transluminal coronary intervention (PCI). We sought to investigate outcomes in elderly patients treated with antithrombotic strategy guided by bleeding and ischemic risks after revascularization with last generation everolimus-eluting stent (EES). METHODS: Prospective multicenter registry including patients over 75 years revascularized with EES and antithrombotic therapy guided by clinical presentation, PCI complexity and PRECISE DAPT score. Co-primary safety endpoints were: (1) composite of cardiac death, myocardial infarction and stent thrombosis and; (2) bleeding (BARC 2-5). Primary efficacy endpoint was target lesion revascularization. A matched group of patients revascularized with current drug-eluting stents and no such tailored antithrombotic therapy was used as control. RESULTS: Finally, 1064 patients were included in SIERRA-75 cohort, 80.8 ± 4.2 years, 36.6% women, 71% acute coronary syndromes (ACS) and 53.6% complex PCI. Co-primary safety endpoint of major adverse cardiovascular events was met in 6.2%, co-primary safety endpoint of bleeding in 7.8% and primary efficacy endpoint of TKLR in 1.5%. The multivariable adjusted model showed no significant association of the prescribed short/long dual antiplatelet therapy (DAPT) durations with any endpoint suggesting a well tailored therapy. No stent thrombosis reported in the subgroup with 1-3 months DAPT duration. As compared to control group, bleeding BARC 2-5 was significantly lower in SIERRA-75 group (7.4% vs. 10.2%, P = 0.04) as well as the net safety-efficacy endpoint (14.3% vs. 18.5%, P = 0.02). CONCLUSIONS: In elderly population, the application of this risks-adjusted antithrombotic protocol after revascularization with last generation EES seems to be associated with an improved prognosis in terms of ischemic and bleeding outcomes.
RESUMEN
We report the case of a 77-year-old man with heart failure (NYHA class IV), angina (CCS class III) and multiple comorbidities. The evaluation showed severe aortic sten osis and left main coronary disease. Due to the very high perioperative risk, conventional surgery was denied. It was therefore decided to perform a combined percutaneous intervention. First, left main PCI was successfully performed. A few days later, a percutaneous aortic valve prosthesis was implanted via a femoral approach using the CoreValve ReValving system. Immediately after prosthesis implantation, the control angiogram showed severe paravalvular aortic regurgitation, which was corrected by implanting another percutaneous aortic prosthesis inside the first one (valve-in-valve procedure). During follow-up the patient experienced a remarkable improvement in hemodynamic and clinical status. We demonstrate that the combination of two different percutaneous interventions in severe aortic and coronary disease is feasible and can be a suitable alternative approach in high surgical risk patients.
Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Enfermedad Coronaria/terapia , Anciano , Angina de Pecho/complicaciones , Angioplastia Coronaria con Balón/métodos , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/terapia , Estenosis de la Válvula Aórtica/complicaciones , Terapia Combinada/métodos , Enfermedad Coronaria/complicaciones , Stents Liberadores de Fármacos , Insuficiencia Cardíaca/complicaciones , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Masculino , Retratamiento/métodosRESUMEN
INTRODUCTION AND OBJECTIVES: The use of mechanical circulatory support is increasing in cases of cardiogenic shock (CS) and high-risk percutaneous coronary intervention (HR-PCI). The Impella® is a percutaneous ventricular assist device that unloads the left ventricle by ejecting blood to the ascending aorta. We report our center's experience with the use of the Impella® device in these two clinical settings. METHODS: We performed a single-center retrospective study including all consecutive patients implanted with the Impella® between 2007 and 2019 for CS treatment or prophylactic support of HR-PCI. Data on clinical and safety endpoints were collected and analyzed. RESULTS: Twenty-two patients were included: 12 were treated for CS and 10 underwent an HR-PCI procedure. In the CS-treated population, the main cause of CS was acute myocardial infarction (five patients); hemolysis was the most frequent device-related complication (63.7%). In-hospital, cumulative 30-day and one-year mortality were 58.3%, 66.6% and 83.3%, respectively. In the HR-PCI group, all patients had multivessel disease (mean baseline SYNTAX I score: 44.1±13.7). In-hospital, 30-day and one-year mortality were 10.0%, 10.0% and 20.0%, respectively. There were no device- or procedure-related deaths in either group. CONCLUSION: The short- and long-term results of Impella®-supported HR-PCI were comparable to those in the literature. In the CS group, in-hospital and short-term outcomes were poor, with high mortality and non-negligible complication rates.
Asunto(s)
Corazón Auxiliar , Infarto del Miocardio , Intervención Coronaria Percutánea , Corazón Auxiliar/efectos adversos , Humanos , Intervención Coronaria Percutánea/efectos adversos , Estudios Retrospectivos , Choque Cardiogénico/terapiaRESUMEN
AIMS: Quadricuspid aortic valve (QAV) is a rare abnormality, which may cause aortic regurgitation (AR) requiring surgical intervention in some patients. The characteristics associated with aortic valve functional degeneration in patients with QAV are still unknown. The aim of this study is to describe QAV prevalence, characterize the disease by multimodality imaging, evaluate predictors of severe AR, and assess mid-term prognosis. METHODS AND RESULTS: Retrospective search in imaging exams database of one tertiary centre, for patients diagnosed with QAV between January 2007 and September 2019. QAV was characterized by cardiac computed tomography, transthoracic/transoesophageal echocardiography, and cardiac magnetic resonance. A total of 160 004 exams were reviewed and eight patients with QAV were identified (50% men, mean age 53.5 ± 10.7 years). The prevalence of QAV was 0.005%. During a median follow-up of 52 months (interquartile range 16-88), there were no deaths. Seven patients (88%) had pure AR (three severe, one moderate, and three mild) and one patient (12%) had moderate AR and moderate aortic stenosis. Three patients (38%) with severe AR underwent valve surgery (two replacements and one repair). Analysis of predictors of severe AR was not statistically significant. CONCLUSION: QAV is a rare congenital cardiac defect, with a prevalence of 0.005% in our study. Its predominant functional abnormality was regurgitation and about one-third of the patients required aortic valve surgery. Multimodality imaging may play a pivotal role in assessing patients with QAV with significant valve dysfunction or associated congenital heart disease and improve their treatment strategy.
Asunto(s)
Insuficiencia de la Válvula Aórtica , Válvula Aórtica Cuadricúspide , Adulto , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/epidemiología , Insuficiencia de la Válvula Aórtica/cirugía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Prevalencia , Pronóstico , Estudios Retrospectivos , Centros de Atención TerciariaRESUMEN
INTRODUCTION: Percutaneous aortic valve implantation is an emerging procedure for the treatment of patients with severe aortic stenosis. METHODS: The procedure was performed in patients with severe symptomatic aortic stenosis, who had been refused for aortic valve replacement surgery. A self-expanding bioprosthesis within a nitinol frame delivered by an 18F catheter was used. Most of the procedures were performed through a femoral artery approach and under local anesthesia and sedation. RESULTS: Thirty-two patients were treated, mean age 80 years, with various comorbidities and mean logistic EuroSCORE of 22%. The procedure was successful in all patients, with a significant improvement in transvalvular gradients. Two patients died due to procedure-related complications. The most common complications were vascular access related and high-degree atrioventricular block requiring permanent pacemaker. No events were reported after one month follow-up, with most patients showing improvement in functional capacity. After 23 months of follow-up (mean 13 months) five additional deaths had occurred. No prosthesis-related events were observed. CONCLUSIONS: Percutaneous aortic valve implantation is safe and improves quality of life in patients with severe symptomatic aortic stenosis. It may be an alternative therapeutic option for patients with high risk features for aortic replacement surgery.
Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Índice de Severidad de la EnfermedadRESUMEN
We describe one of the first-in-human cases of valve-in-valve transcatheter aortic valve implantation (TAVI) using fluoroscopic-only guidance for the treatment of late failure of a bio-prosthetic Bentall conduit, the BioValsalva™ Vascutek (Vascutek Terumo, Renfrewshire, Scotland), using a self-expandable heart valve prosthesis (CoreValve™ Evolut™ R, Medtronic, Dublin Ireland).
RESUMEN
INTRODUCTION AND OBJECTIVES: Elective percutaneous coronary intervention (PCI) has become an increasingly safe procedure. However, same day discharge (SDD) has yet to become standard practice. Our aim is to characterize the patients who underwent elective PCI and compare outcomes between the overnight stay (ONS) patient group and the group that was discharged on the same day at 24 hours and at 30 days. METHODS: One-year registry of patients who underwent an elective PCI. The possibility of SDD was established by the operator. Appropriate candidates were discharged at least four hours after the end of the intervention. The primary endpoints were defined as: Major adverse cardiac and cerebrovascular events (MACCE) - death, myocardial infarction (MI) stroke or transient ischemic attack (TIA), non-planned re-intervention - and vascular complications. Secondary endpoints were any unplanned hospital visit, readmission and re-catheterization. RESULTS: We performed 155 elective PCIs. One patient was admitted to the coronary care unit; 111 patients stayed overnight (ONS Group); 43 patients were discharged the same day (SDD Group). Three patients had early (<4 hours) post procedure complications: two TIAs and one vascular access site complication. There were no MACCE between four and 24 hours, nor at 30 days. At 24 hours, two patients from the SDD group had unplanned visits. Between one and 30 days, more patients from the SDD group had unplanned visits (9.3% vs. 0.9%. p=0.02). One patient from the ONS group had a recatherization. There were no readmissions or reinterventions. CONCLUSION: Same day discharge of selected patients who undergo elective PCIs is feasible and safe.
Asunto(s)
Alta del Paciente , Intervención Coronaria Percutánea , Procedimientos Quirúrgicos Electivos , Humanos , Tiempo de Internación , Intervención Coronaria Percutánea/efectos adversos , Resultado del TratamientoRESUMEN
INTRODUCTION: Transcatheter aortic valve implantation (TAVI) is associated with cardiac electrical disturbances. However, beyond the risks of pacemaker implantation, few studies have performed a detailed assessment of the effects of TAVI on several cardiac electrical properties. OBJECTIVES: To assess the frequency and type of electrocardiographic disturbances following TAVI, according to the type of prostheses and to assess predictors of these disturbances. METHODS: We performed a detailed retrospective analysis of all electrocardiograms in patients who underwent TAVI, before and after the procedure, at a tertiary center from August 2007 to October 2016. Patients with permanent pacemakers were excluded. RESULTS: We included 182 patients (78±8 years; 56% female) and self-expanding prostheses (SEP) were implanted in 54%. Most patients (80%) were in sinus rhythm at baseline. After TAVI, 21% of patients developed new-onset atrial fibrillation and there was a significant increase in PR interval at discharge (186±41 ms vs. 176±32; p=0.003), which was not maintained after at six-month follow-up (181±35 ms, p=0.06). There was also a significant increase in QRS duration at discharge (129±28 ms vs. 114±25 at baseline p<0.0001), which persisted at six-months (122±28 ms, p<0.0001). New-onset left-bundle branch block (LBBB) was observed in 25% of patients. The depth of valve implantation was a predictor of new LBBB at discharge after multivariate analysis (OR 37.6, 95% CI 14.6-65.2, p=0.001). CONCLUSIONS: The main electrocardiographic disturbances post TAVI were PR prolongation, increased QRS and new-onset LBBB. These disturbances were more pronounced in patients undergoing SEP implantation and tended to improve at six-month follow-up. The depth of valve implantation was a predictor of conduction disturbances.
Asunto(s)
Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Femenino , Humanos , Masculino , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del TratamientoRESUMEN
Importance: Approximately one-third of patients considered for coronary revascularization have diabetes, which is a major determinant of clinical outcomes, often influencing the choice of the revascularization strategy. The usefulness of fractional flow reserve (FFR) to guide treatment in this population is understudied and has been questioned. Objective: To evaluate the usefulness and rate of major adverse cardiovascular events (MACE) of integrating FFR in management decisions for patients with diabetes who undergo coronary angiography. Design, Setting, and Participants: This cross-sectional study used data from the PRIME-FFR study derived from the merger of the POST-IT study (Portuguese Study on the Evaluation of FFR-Guided Treatment of Coronary Disease [March 2012-November 2013]) and R3F study (French Study of FFR Integrated Multicenter Registries Implementation of FFR in Routine Practice [October 2008-June 2010]), 2 prospective multicenter registries that shared a common design. A population of all-comers for whom angiography disclosed ambiguous lesions was analyzed for rates, patterns, and outcomes associated with management reclassification, including revascularization deferral, in patients with vs without diabetes. Data analysis was performed from June to August 2018. Main Outcomes and Measures: Death from any cause, myocardial infarction, or unplanned revascularization (MACE) at 1 year. Results: Among 1983 patients (1503 [77%] male; mean [SD] age, 65 [10] years), 701 had diabetes, and FFR was performed for 1.4 lesions per patient (58.2% of lesions in the left anterior descending artery; mean [SD] stenosis, 56% [11%]; mean [SD] FFR, 0.81 [0.01]). Reclassification by FFR was high and similar in patients with and without diabetes (41.2% vs 37.5%, P = .13), but reclassification from medical treatment to revascularization was more frequent in the former (142 of 342 [41.5%] vs 230 of 730 [31.5%], P = .001). There was no statistical difference between the 1-year rates of MACE in reclassified (9.7%) and nonreclassified patients (12.0%) (P = .37). Among patients with diabetes, FFR-based deferral identified patients with a lower risk of MACE at 12 months (25 of 296 [8.4%]) compared with those undergoing revascularization (47 of 257 [13.1%]) (P = .04), and the rate was of the same magnitude of the observed rate among deferred patients without diabetes (7.9%, P = .87). Status of insulin treatment had no association with outcomes. Patients (6.6% of the population) in whom FFR was disregarded had the highest MACE rates regardless of diabetes status. Conclusions and Relevance: Routine integration of FFR for the management of coronary artery disease in patients with diabetes may be associated with a high rate of treatment reclassification. Management strategies guided by FFR, including revascularization deferral, may be useful for patients with diabetes.
Asunto(s)
Toma de Decisiones Clínicas , Enfermedad de la Arteria Coronaria/terapia , Diabetes Mellitus , Reserva del Flujo Fraccional Miocárdico , Anciano , Fármacos Cardiovasculares/uso terapéutico , Angiografía Coronaria , Puente de Arteria Coronaria , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/terapia , Estudios Transversales , Femenino , Humanos , Masculino , Infarto del Miocardio/epidemiología , Intervención Coronaria Percutánea , Estudios ProspectivosRESUMEN
Introduction Balloon aortic valvuloplasty (BAV), introduced in 1986, quickly lost its wide adoption due to the high incidence of restenosis after the procedure and due to improved skills in transcatheter aortic valve implantation (TAVI). It has seen a re-emergence in the last few years as bailout therapy in critical care patients presenting with cardiogenic shock (CS) and severe aortic stenosis (AS), who are temporarily unable to tolerate such a procedure as TAVI or surgery for valve replacement. Methods We did a retrospective analysis of every BAV performed between January 1, 2008, and November 11, 2018, in our hospital and identified those admitted to the cardiac intensive care unit (CICU) due to cardiogenic shock with severe aortic stenosis, as defined in the European Society of Cardiology Guidelines. Procedures were categorized as emergent (within 24h after the decision to intervene) and urgent (24h after the decision was made but before discharge). Results During this period, of 98 BAV performed, 14 were performed on patients with CS with severe AS, nine of them being emergent. The patients' mean age was 76.2±7.2 years, with 6 (43%) of them being female. On the day of BAV, the mean Euroscore II and sequential organ failure (SOFA) were, respectively, 19±7% and 8.0±2.4 in emergent cases and 11±5% and 4.8±2.9 in urgent cases. In patients deemed emergent, there was a tendency for a decrease in SOFA in the days following the procedure, although not statistically significant (p>0.05). Clinically significant aortic regurgitation did not occur in any patient, neither were there any major post-procedure complications. Thirty-day mortality was 33% in emergent cases and 0% in urgent cases. In emergent cases, four were later submitted to TAVI and one had surgery for aortic valve replacement surgery. Only one patient in the urgent group was regarded as a candidate for TAVI. Discussion and conclusion Emergent cases presented with higher scores of severity and procedure risk and had greater mortality. In this group, a greater proportion of survivors was later deemed fit for definite procedures. This highlights that presenting status does not seem to influence the prognosis of those extremely high-risk patients once the acute event is promptly treated. Nevertheless, the low sample size precludes generalization of the findings. BAV as bailout treatment may be safe in patients presenting with CS and severe AS, allowing patient survival for elective definitive treatment.
Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Stents/efectos adversos , Resultado del Tratamiento , Diseño de PrótesisRESUMEN
A substituição transcateter valve-in-valve da valva mitral surgiu recentemente como uma alternativa cada vez mais utilizada nos pacientes de alto risco cirúrgico. O presente caso relata uma substituição de valva mitral transcateter valve-in-valve, por via transeptal, como tratamento da degeneração de uma bioprótese mitral cirúrgica e regurgitação grave, em paciente de 86 anos já submetido a uma substituição transcateter valve-in-valve aórtica, há 6 anos. Este caso enfatiza o papel crucial de uma avaliação pré-operatória cuidadosa, com uso de diferentes modalidades de exames de imagem, para planejamento do procedimento, em paciente com maior risco de obstrução da via de saída do ventrículo esquerdo, devido a um procedimento valve-in-valve aórtico prévio.
Transcatheter mitral valve-in-valve replacement has recently emerged as an increasingly common alternative for high surgical risk patients. We report a case of a successful transseptal transcatheter mitral valve-in-valve replacement for the treatment of a bioprosthetic mitral valve degeneration and severe regurgitation, in an 86-year-old patient who had undergone transcatheter aortic valve-in-valve procedure 6 years ago. This case emphasizes the crucial role of a careful preoperative assessment using multimodality imaging to plan the procedure, in a patient with higher risk of left ventricular outflow obstruction due to the previous transcatheter aortic valve-in- valve procedure.
RESUMEN
Percutaneous coronary intervention (PCI) has been increasingly performed in patients with severely depressed left ventricular function and complex coronary lesions, including multivessel disease. Mechanical ventricular assist devices play an increasingly important role in high-risk PCI. Impella CP® (Abiomed, Inc.) is a new percutaneous left ventricular assist device, designed for short-term circulatory support. It is a promising option for hemodynamic support in high-risk procedures and can potentially reduce PCI-related complications. The authors present two case reports of high-risk PCI using the Impella CP® device. In the setting of low coronary flow reserve, severely depressed left ventricular function and potential hemodynamic instability, the Impella CP® device has made it possible to maintain hemodynamic stability during procedures, without being associated with vascular complications.