Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 72
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Opt Express ; 29(2): 552-563, 2021 Jan 18.
Artículo en Inglés | MEDLINE | ID: mdl-33726288

RESUMEN

An optical platform is presented for examining intrinsic contrast detection strategies when imaging retinal structure using ex vivo tissue. A custom microscope was developed that scans intact tissue and collects scattered light distribution at every image pixel, allowing digital masks to be applied after image collection. With this novel approach at measuring the spatial distribution of multiply scattered light, known and novel methods of detecting intrinsic cellular contrast can be explored, compared, and optimized for retinal structures of interest.


Asunto(s)
Sensibilidad de Contraste/fisiología , Microscopía/instrumentación , Células Fotorreceptoras de Vertebrados/efectos de la radiación , Dispersión de Radiación , Animales , Diseño de Equipo , Luz , Sciuridae
2.
Appl Opt ; 59(34): 10673-10679, 2020 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-33361885

RESUMEN

A liquid crystal variable retarder (LCVR) enables fast, automated control of retardance that can be used as a variable waveplate in polarimetric instruments. However, precise control of the polarization state requires calibration of the LCVR. A manufacturer calibration curve is typically supplied for a single specific wavelength and temperature, but for applications under different conditions, additional calibration is needed. Calibration is typically performed with crossed polarizers to generate an intensity curve that is converted to retardance, but this method is prone to noise when retardance is close to zero. Here, we demonstrate a simple common-path Sagnac interferometer to measure retardance and provide open source software for automated generation of calibration curves for retardance as a function of wavelength and voltage. We also provide a curve fitting method and closed-form functional representation that outputs the voltage needed to achieve a desired retardance given a specified wavelength.

3.
Appl Opt ; 59(18): 5521-5526, 2020 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-36926458

RESUMEN

Supercontinuum (SC) sources offer high illumination power from a single mode fiber with large spectral bandwidth including the visible spectrum, a growing application area for Optical Coherence Tomography (OCT). However, SC spectra suffer from pulse-to-pulse variations, increasing noise in the resulting images. By simultaneously collecting a normalization spectrum, OCT image noise can be reduced by more than half (7 dB) for single pulses without any pulse averaging using only simple optical components.

4.
Opt Express ; 26(19): 25020-25030, 2018 Sep 17.
Artículo en Inglés | MEDLINE | ID: mdl-30469610

RESUMEN

Whispering-gallery mode (WGM) microresonators have recently been employed as platforms for label-free single-molecule and single-particle detection, imaging, and spectroscopy. However, innovations in device geometry and integration are needed to make WGM microresonators more versatile for biological and chemical applications. Particularly, thick device substrates, originating from wafer-scale fabrication processing, prevent convenient optical interrogation. In this work, we fabricate all-glass toroidal microresonators on a coverslip thickness (~170 µm) substrate, enabling excitation delivery through the sample, simplifying optical integration. Further, we demonstrate the application of this new geometry for single-particle photothermal imaging. Finally, we discover and develop simulations to explain a non-trivial astigmatism in the point spread function (PSF) arising from the curvature of the resonator.

6.
BMC Ecol ; 16: 10, 2016 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-26996922

RESUMEN

BACKGROUND: At the forefront of ecosystems adversely affected by climate change, coral reefs are sensitive to anomalously high temperatures which disassociate (bleaching) photosynthetic symbionts (Symbiodinium) from coral hosts and cause increasingly frequent and severe mass mortality events. Susceptibility to bleaching and mortality is variable among corals, and is determined by unknown proportions of environmental history and the synergy of Symbiodinium- and coral-specific properties. Symbiodinium live within host tissues overlaying the coral skeleton, which increases light availability through multiple light-scattering, forming one of the most efficient biological collectors of solar radiation. Light-transport in the upper ~200 µm layer of corals skeletons (measured as 'microscopic' reduced-scattering coefficient, µ'(S,m)), has been identified as a determinant of excess light increase during bleaching and is therefore a potential determinant of the differential rate and severity of bleaching response among coral species. RESULTS: Here we experimentally demonstrate (in ten coral species) that, under thermal stress alone or combined thermal and light stress, low-µ'(S,m) corals bleach at higher rate and severity than high-µ'(S,m) corals and the Symbiodinium associated with low-µ'(S,m) corals experience twice the decrease in photochemical efficiency. We further modelled the light absorbed by Symbiodinium due to skeletal-scattering and show that the estimated skeleton-dependent light absorbed by Symbiodinium (per unit of photosynthetic pigment) and the temporal rate of increase in absorbed light during bleaching are several fold higher in low-µ'(S,m) corals. CONCLUSIONS: While symbionts associated with low-[Formula: see text] corals receive less total light from the skeleton, they experience a higher rate of light increase once bleaching is initiated and absorbing bodies are lost; further precipitating the bleaching response. Because microscopic skeletal light-scattering is a robust predictor of light-dependent bleaching among the corals assessed here, this work establishes µ'(S,m) as one of the key determinants of differential bleaching response.


Asunto(s)
Antozoos/fisiología , Antozoos/efectos de la radiación , Arrecifes de Coral , Dinoflagelados/fisiología , Animales , Luz , Fotoblanqueo , Dispersión de Radiación , Simbiosis , Temperatura
7.
J Emerg Med ; 50(3): 433-6, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26589567

RESUMEN

BACKGROUND: Opioid analgesics are widely used in health care, yet have significant potential for abuse. High doses are associated with potentially fatal respiratory depression, which caused 21,314 deaths in the United States in 2011. Acetylfentanyl, a synthetic opioid agonist closely related to fentanyl, recently emerged as a drug of abuse linked to numerous deaths in North America. CASE REPORT: A 36-year-old male developed the habit of using a propylene glycol electronic cigarette filled with acetylfentanyl to aid relaxation. He purchased the drug online in a manner that appeared legal to him, which compromised his insight about the danger of the substance. He had been using the e-cigarette with increasing frequency while on medical leave, and his wife reported finding him weakly responsive on more than one occasion. At approximately 3 am, the family activated 911 for altered mental status. His presentation included respiratory depression, pinpoint pupils, hypoxemia, and a Glasgow Coma Scale score of 6. He responded to serial doses of intravenous naloxone with improvement in his mental status and respiratory condition. Due to the need for repeated dosing, he was placed on a naloxone infusion and recovered uneventfully in intensive care. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: Complications from emerging drugs of abuse, like acetylfentanyl, frequently present first to emergency departments. Prompt recognition and treatment can help avoid morbidity and mortality. Acetylfentanyl can be managed effectively with naloxone, although higher than conventional dosing may be required to achieve therapeutic effect.


Asunto(s)
Analgésicos Opioides/envenenamiento , Fentanilo/análogos & derivados , Psicotrópicos/envenenamiento , Insuficiencia Respiratoria/inducido químicamente , Trastornos Relacionados con Sustancias/etiología , Adulto , Fentanilo/envenenamiento , Humanos , Masculino
8.
J Paediatr Child Health ; 50(10): 787-90, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24910094

RESUMEN

AIM: Musculoskeletal symptoms are a common cause for presentation of children and adolescents to health-care settings. Junior doctors report lack of confidence in assessment of the paediatric musculoskeletal system. Our aim was to assess the confidence of junior medical officers (JMOs) working in the emergency department (ED) with paediatric musculoskeletal assessment and determine if a readily available teaching module would improve confidence. METHODS: JMOs rostered to the paediatric ED were surveyed regarding their confidence in paediatric musculoskeletal assessment at the start and end of their ED rotation. A subgroup of these JMOs received formal teaching on paediatric musculoskeletal assessment using the paediatric gait, arm, leg and spine examination as part of their protected teaching time during their rotation. RESULTS: Forty-three JMOs were considered in the final analysis. Of those, 27 received teaching (intervention group), and 16 received no teaching (non-intervention group). In the intervention subgroup, there was a trend towards an increase in confidence in paediatric musculoskeletal assessment with the commonest response prior to the teaching intervention being 'some confidence' (11/27 41%) and the commonest response after teaching being 'fairly confident' (14/27 52%) without achieving statistical significance (P = 0.068). Of the JMOs in the intervention group, 26/27 (96%) found the teaching session useful, and 25/27 (93%) considered it relevant to their future practice. CONCLUSIONS: A clinical examination teaching intervention resulted in a trend towards an increase in confidence for JMOs in paediatric musculoskeletal assessment. Formal evaluation of a teaching module was feasible within the ED.


Asunto(s)
Competencia Clínica , Cuerpo Médico de Hospitales/educación , Enfermedades Musculoesqueléticas/diagnóstico , Examen Físico/métodos , Adolescente , Adulto , Actitud del Personal de Salud , Niño , Servicio de Urgencia en Hospital , Femenino , Encuestas de Atención de la Salud , Humanos , Internado y Residencia , Masculino , Cuerpo Médico de Hospitales/psicología , Pediatría/educación , Mejoramiento de la Calidad , Autoevaluación (Psicología)
9.
Biomed Opt Express ; 15(3): 1408-1417, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38495713

RESUMEN

Assessing cell viability is important in many fields of research. Current optical methods to assess cell viability typically involve fluorescent dyes, which are often less reliable and have poor permeability in primary tissues. Dynamic optical coherence microscopy (dOCM) is an emerging tool that provides label-free contrast reflecting changes in cellular metabolism. In this work, we compare the live contrast obtained from dOCM to viability dyes, and for the first time to our knowledge, demonstrate that dOCM can distinguish live cells from dead cells in murine syngeneic tumors. We further demonstrate a strong correlation between dOCM live contrast and optical redox ratio by metabolic imaging in primary mouse liver tissue. The dOCM technique opens a new avenue to apply label-free imaging to assess the effects of immuno-oncology agents, targeted therapies, chemotherapy, and cell therapies using live tumor tissues.

10.
Opt Express ; 21(7): 9043-59, 2013 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-23571994

RESUMEN

Exploration of nanoscale tissue structures is crucial in understanding biological processes. Although novel optical microscopy methods have been developed to probe cellular features beyond the diffraction limit, nanometer-scale quantification remains still inaccessible for in situ tissue. Here we demonstrate that, without actually resolving specific geometrical feature, OCT can be sensitive to tissue structural properties at the nanometer length scale. The statistical mass-density distribution in tissue is quantified by its autocorrelation function modeled by the Whittle-Matern functional family. By measuring the wavelength-dependent backscattering coefficient µb(λ) and the scattering coefficient µs, we introduce a technique called inverse spectroscopic OCT (ISOCT) to quantify the mass-density correlation function. We find that the length scale of sensitivity of ISOCT ranges from ~30 to ~450 nm. Although these sub-diffractional length scales are below the spatial resolution of OCT and therefore not resolvable, they are nonetheless detectable. The sub-diffractional sensitivity is validated by 1) numerical simulations; 2) tissue phantom studies; and 3) ex vivo colon tissue measurements cross-validated by scanning electron microscopy (SEM). Finally, the 3D imaging capability of ISOCT is demonstrated with ex vivo rat buccal and human colon samples.


Asunto(s)
Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Modelos Biológicos , Modelos Estadísticos , Tomografía de Coherencia Óptica/métodos , Animales , Simulación por Computador , Humanos , Ratas , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
11.
IEEE J Sel Top Quantum Electron ; 20(2): 7000514, 2013 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-25587211

RESUMEN

Optical interactions with biological tissue provide powerful tools for study, diagnosis, and treatment of disease. When optical methods are used in applications involving tissue, scattering of light is an important phenomenon. In imaging modalities, scattering provides contrast, but also limits imaging depth, so models help optimize an imaging technique. Scattering can also be used to collect information about the tissue itself providing diagnostic value. Therapies involving focused beams require scattering models to assess dose distribution. In all cases, models of light scattering in tissue are crucial to correctly interpreting the measured signal. Here, we review a versatile model of light scattering that uses the Whittle-Matérn correlation family to describe the refractive index correlation function Bn (rd ). In weakly scattering media such as tissue, Bn (rd ) determines the shape of the power spectral density from which all other scattering characteristics are derived. This model encompasses many forms such as mass fractal and the Henyey-Greenstein function as special cases. We discuss normalization and calculation of optical properties including the scattering coefficient and anisotropy factor. Experimental methods using the model are also described to quantify tissue properties that depend on length scales of only a few tens of nanometers.

12.
Methods Mol Biol ; 2614: 187-235, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36587127

RESUMEN

With recent advances in cancer therapeutics, there is a great need for improved imaging methods for characterizing cancer onset and progression in a quantitative and actionable way. Collagen, the most abundant extracellular matrix protein in the tumor microenvironment (and the body in general), plays a multifaceted role, both hindering and promoting cancer invasion and progression. Collagen deposition can defend the tumor with immunosuppressive effects, while aligned collagen fiber structures can enable tumor cell migration, aiding invasion and metastasis. Given the complex role of collagen fiber organization and topology, imaging has been a tool of choice to characterize these changes on multiple spatial scales, from the organ and tumor scale to cellular and subcellular level. Macroscale density already aids in the detection and diagnosis of solid cancers, but progress is being made to integrate finer microscale features into the process. Here we review imaging modalities ranging from optical methods of second harmonic generation (SHG), polarized light microscopy (PLM), and optical coherence tomography (OCT) to the medical imaging approaches of ultrasound and magnetic resonance imaging (MRI). These methods have enabled scientists and clinicians to better understand the impact collagen structure has on the tumor environment, at both the bulk scale (density) and microscale (fibrillar structure) levels. We focus on imaging methods with the potential to both examine the collagen structure in as natural a state as possible and still be clinically amenable, with an emphasis on label-free strategies, exploiting intrinsic optical properties of collagen fibers.


Asunto(s)
Neoplasias , Microambiente Tumoral , Humanos , Colágenos Fibrilares/química , Diagnóstico por Imagen , Colágeno/metabolismo , Matriz Extracelular/metabolismo , Neoplasias/diagnóstico por imagen , Neoplasias/metabolismo
13.
bioRxiv ; 2023 Feb 03.
Artículo en Inglés | MEDLINE | ID: mdl-36778488

RESUMEN

Single photon avalanche diode (SPAD) array sensors can increase the imaging speed for fluorescence lifetime imaging microscopy (FLIM) by transitioning from laser scanning to widefield geometries. While a SPAD camera in epi-fluorescence geometry enables widefield FLIM of fluorescently labeled samples, label-free imaging of single-cell autofluorescence is not feasible in an epi-fluorescence geometry because background fluorescence from out-of-focus features masks weak cell autofluorescence and biases lifetime measurements. Here, we address this problem by integrating the SPAD camera in a light sheet illumination geometry to achieve optical sectioning and limit out-of-focus contributions, enabling fast label-free FLIM of single-cell NAD(P)H autofluorescence. The feasibility of this NAD(P)H light sheet FLIM system was confirmed with time-course imaging of metabolic perturbations in pancreas cancer cells with 10 s integration times, and in vivo NAD(P)H light sheet FLIM was demonstrated with live neutrophil imaging in a zebrafish tail wound, also with 10 s integration times. Finally, the theoretical and practical imaging speeds for NAD(P)H FLIM were compared across laser scanning and light sheet geometries, indicating a 30X to 6X frame rate advantage for the light sheet compared to the laser scanning geometry. This light sheet system provides faster frame rates for 3D NAD(P)H FLIM for live cell imaging applications such as monitoring single cell metabolism and immune cell migration throughout an entire living organism.

14.
J Biomed Opt ; 28(6): 066502, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37351197

RESUMEN

Significance: Fluorescence lifetime imaging microscopy (FLIM) of the metabolic co-enzyme nicotinamide adenine dinucleotide (phosphate) [NAD(P)H] is a popular method to monitor single-cell metabolism within unperturbed, living 3D systems. However, FLIM of NAD(P)H has not been performed in a light-sheet geometry, which is advantageous for rapid imaging of cells within live 3D samples. Aim: We aim to design, validate, and demonstrate a proof-of-concept light-sheet system for NAD(P)H FLIM. Approach: A single-photon avalanche diode camera was integrated into a light-sheet microscope to achieve optical sectioning and limit out-of-focus contributions for NAD(P)H FLIM of single cells. Results: An NAD(P)H light-sheet FLIM system was built and validated with fluorescence lifetime standards and with time-course imaging of metabolic perturbations in pancreas cancer cells with 10 s integration times. NAD(P)H light-sheet FLIM in vivo was demonstrated with live neutrophil imaging in a larval zebrafish tail wound also with 10 s integration times. Finally, the theoretical and practical imaging speeds for NAD(P)H FLIM were compared across laser scanning and light-sheet geometries, indicating a 30× to 6× acquisition speed advantage for the light sheet compared to the laser scanning geometry. Conclusions: FLIM of NAD(P)H is feasible in a light-sheet geometry and is attractive for 3D live cell imaging applications, such as monitoring immune cell metabolism and migration within an organism.


Asunto(s)
NAD , Neoplasias Pancreáticas , Animales , NAD/metabolismo , Pez Cebra , Microscopía Fluorescente/métodos , Fotones , Imagen Óptica/métodos
15.
Opt Express ; 20(18): 19643-57, 2012 Aug 27.
Artículo en Inglés | MEDLINE | ID: mdl-23037017

RESUMEN

Low-coherence enhanced backscattering (LEBS) spectroscopy is an angular resolved backscattering technique that is sensitive to sub-diffusion light transport length scales in which information about scattering phase function is preserved. Our group has shown the ability to measure the spatial backscattering impulse response function along with depth-selective optical properties in tissue ex-vivo using LEBS. Here we report the design and implementation of a lens-free fiber optic LEBS probe capable of providing depth-limited measurements of the reduced scattering coefficient in-vivo. Experimental measurements combined with Monte Carlo simulation of scattering phantoms consisting of polystyrene microspheres in water are used to validate the performance of the probe. Additionally, depth-limited capabilities are demonstrated using Monte Carlo modeling and experimental measurements from a two-layered phantom.


Asunto(s)
Tecnología de Fibra Óptica/instrumentación , Nefelometría y Turbidimetría/instrumentación , Fotometría/instrumentación , Análisis Espectral/instrumentación , Transductores , Diseño Asistido por Computadora , Diseño de Equipo , Análisis de Falla de Equipo
16.
Opt Lett ; 37(24): 5220-2, 2012 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-23258058

RESUMEN

Which range of structures contributes to light scattering in a continuous random media, such as biological tissue? In this Letter, we present a model to study the structural length-scale sensitivity of scattering in continuous random media under the Born approximation. The scattering coefficient µs, backscattering coefficient µb, anisotropy factor g, and reduced scattering coefficient µs* as well as the shape of the spatial reflectance profile are calculated under this model. For media with a biologically relevant Henyey-Greenstein phase function with g∼0.93 at wavelength λ=633 nm, we report that µs* is sensitive to structural length-scales from 46.9 nm to 2.07 µm (i.e., λ/13 to 3λ), µb is sensitive from 26.7 to 320 nm (i.e., λ/24 to λ/2), and the spatial reflectance profile is sensitive from 30.8 nm to 2.71 µm (i.e., λ/21 to 4λ).


Asunto(s)
Luz , Modelos Biológicos , Modelos Estadísticos , Nefelometría y Turbidimetría/métodos , Fotometría/métodos , Animales , Simulación por Computador , Humanos , Dispersión de Radiación
17.
Opt Lett ; 37(4): 506-8, 2012 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-22344088

RESUMEN

Quantification of intracellular nanoscale macromolecular density distribution is a fundamental aspect to understanding cellular processes. We report a near-field penetrating optical microscopy (NPOM) technique to directly probe the internal nanoscale macromolecular density of biological cells through quantification of intracellular refractive index (RI). NPOM inserts a tapered optical fiber probe to successive depths into an illuminated sample. A 50 nm diameter probe tip collects signal that exhibits a linear relationship with the sample RI at a spatial resolution of approximately 50 nm for biologically relevant measurements, one order of magnitude finer than the Abbe diffraction limit. Live and fixed cell data illustrate the mechanical ability of a 50 nm probe to penetrate biological samples.


Asunto(s)
Células/ultraestructura , Microscopía/métodos , Mejilla , Humanos , Sustancias Macromoleculares/ultraestructura , Microscopía de Sonda de Barrido/métodos , Fibras Ópticas , Refractometría/métodos
18.
IEEE J Sel Top Quantum Electron ; 18(4): 1313-1325, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24163574

RESUMEN

Since the early 1980's, the enhanced backscattering (EBS) phenomenon has been well-studied in a large variety of non-biological materials. Yet, until recently the use of conventional EBS for the characterization of biological tissue has been fairly limited. In this work we detail the unique ability of EBS to provide spectroscopic, polarimetric, and depth-resolved characterization of biological tissue using a simple backscattering instrument. We first explain the experimental and numerical procedures used to accurately measure and model the full azimuthal EBS peak shape in biological tissue. Next we explore the peak shape and height dependencies for different polarization channels and spatial coherence of illumination. We then illustrate the extraordinary sensitivity of EBS to the shape of the scattering phase function using suspensions of latex microspheres. Finally, we apply EBS to biological tissue samples in order to measure optical properties and observe the spatial length-scales at which backscattering is altered in early colon carcinogenesis.

19.
Opt Express ; 19(13): 11922-31, 2011 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-21716426

RESUMEN

Enhanced backscattering (EBS), also known as weak localization of light, is derived using the Huygens-Fresnel principle and backscattering is generally shown to be the sum of an incoherent baseline and a phase conjugated portion of the incident wave that forms EBS. The phase conjugated portion is truncated by an effective aperture described by the probability function P(s) of coherent path-pair separations. P(s) is determined by the scattering properties of the medium and so characterization of EBS can be used for metrology of scattering materials. A three dimensional intensity peak is predicted in free space at a point conjugate to the source and is experimentally observed.


Asunto(s)
Tecnología de Fibra Óptica/métodos , Rayos Láser , Luz , Modelos Teóricos , Dispersión de Radiación , Artefactos , Método de Montecarlo
20.
Opt Lett ; 36(9): 1596-8, 2011 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-21540939

RESUMEN

Rigorous numerical modeling of optical systems has attracted interest in diverse research areas ranging from biophotonics to photolithography. We report the full-vector electromagnetic numerical simulation of a broadband optical imaging system with partially coherent and unpolarized illumination. The scattering of light from the sample is calculated using the finite-difference time-domain (FDTD) numerical method. Geometrical optics principles are applied to the scattered light to obtain the intensity distribution at the image plane. Multilayered object spaces are also supported by our algorithm. For the first time, numerical FDTD calculations are directly compared to and shown to agree well with broadband experimental microscopy results.


Asunto(s)
Modelos Teóricos , Fenómenos Ópticos , Vidrio , Luz , Dispersión de Radiación , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA