1.
Artif Organs ; 47(3): 464-469, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36398921

RESUMEN

BACKGROUND: Prolonged mechanical ventilation caused by ventilator-induced diaphragm dysfunction (VIDD) is a serious problem in critically ill patients. Identification of patients who will have difficulty weaning from ventilation along with attempts to reduce total time on mechanical ventilation is some of the aims of intensive care medicine. OBSERVATIONS: This article briefly summarizes current options for temporary phrenic nerve stimulation therapy in an effort to keep the diaphragm active as direct prevention and treatment of ventilator-associated diaphragmatic dysfunction in patients on mechanical ventilation. The results of feasibility studies using different approaches are promising but so far, the clinical relevance is low. One important question is which tool would reliably identify early signs of diaphragmatic dysfunction and also be useful in guiding therapy. The authors present a brief overview of the current options considering the advantages and disadvantages of the available examination modalities. Despite the fact that current data point out some limitations of ultrasound examination, we believe that it still has a unique position in the bedside examination of critically ill patients on mechanical ventilation. CONCLUSION: Temporary phrenic nerve stimulation, regardless of the specific approach used, has the potential to directly treat or reverse VIDD, and ultrasound examination plays an important role in the comprehensive care of critically ill patients.


Asunto(s)
Enfermedad Crítica , Nervio Frénico , Humanos , Enfermedad Crítica/terapia , Respiración Artificial , Ventiladores Mecánicos , Respiración
2.
Sensors (Basel) ; 23(20)2023 Oct 23.
Artículo en Inglés | MEDLINE | ID: mdl-37896737

RESUMEN

Laparoscopic surgery with capnoperitoneum brings many advantages to patients, but also emphasizes the negative impact of anesthesia and mechanical ventilation on the lungs. Even though many studies use electrical impedance tomography (EIT) for lung monitoring during these surgeries, it is not clear what the best position of the electrode belt on the patient's thorax is, considering the cranial shift of the diaphragm. We monitored 16 patients undergoing a laparoscopic surgery with capnoperitoneum using EIT with two independent electrode belts at different tomographic levels: in the standard position of the 4th-6th intercostal space, as recommended by the manufacturer, and in a more cranial position at the level of the axilla. Functional residual capacity (FRC) was measured, and a recruitment maneuver was performed at the end of the procedure by raising the positive end-expiratory pressure (PEEP) by 5 cmH2O. The results based on the spectral analysis of the EIT signal show that the ventilation-related impedance changes are not detectable by the belt in the standard position. In general, the cranial belt position might be more suitable for the lung monitoring during the capnoperitoneum since the ventilation signal remains dominant in the obtained impedance waveform. FRC was significantly decreased by the capnoperitoneum and remained lower also after desufflation.


Asunto(s)
Laparoscopía , Tomografía Computarizada por Rayos X , Humanos , Impedancia Eléctrica , Tomografía/métodos , Electrodos
3.
Biomed Eng Online ; 21(1): 14, 2022 Feb 13.
Artículo en Inglés | MEDLINE | ID: mdl-35152895

RESUMEN

BACKGROUND: The role of high-frequency oscillatory ventilation (HFOV) has long been debated. Numerous studies documented its benefits, whereas several more recent studies did not prove superiority of HFOV over protective conventional mechanical ventilation (CV). One of the accepted explanations is that CV and HFOV act differently, including gas exchange. METHODS: To investigate a different level of coupling or decoupling between oxygenation and carbon dioxide elimination during CV and HFOV, we conducted a prospective crossover animal study in 11 healthy pigs. In each animal, we found a normocapnic tidal volume (VT) after the lung recruitment maneuver. Then, VT was repeatedly changed over a wide range while keeping constant the levels of PEEP during CV and mean airway pressure during HFOV. Arterial partial pressures of oxygen (PaO2) and carbon dioxide (PaCO2) were recorded. The same procedure was repeated for CV and HFOV in random order. RESULTS: Changes in PaCO2 intentionally induced by adjustment of VT affected oxygenation more significantly during HFOV than during CV. Increasing VT above its normocapnic value during HFOV caused a significant improvement in oxygenation, whereas improvement in oxygenation during CV hyperventilation was limited. Any decrease in VT during HFOV caused a rapid worsening of oxygenation compared to CV. CONCLUSION: A change in PaCO2 induced by the manipulation of tidal volume inevitably brings with it a change in oxygenation, while this effect on oxygenation is significantly greater in HFOV compared to CV.


Asunto(s)
Ventilación de Alta Frecuencia , Intercambio Gaseoso Pulmonar , Animales , Pulmón , Estudios Prospectivos , Porcinos , Volumen de Ventilación Pulmonar
4.
BMC Pediatr ; 22(1): 350, 2022 06 17.
Artículo en Inglés | MEDLINE | ID: mdl-35715764

RESUMEN

OBJECTIVE: Neonatal exposure to episodic hypoxemia and hyperoxemia is highly relevant to outcomes. Our goal was to investigate the differences in the frequency and duration of extreme low and high SpO2 episodes between automated and manual inspired oxygen control. DESIGN: Post-hoc analysis of a cohort from prospective randomized cross-over studies. SETTING: Seven tertiary care neonatal intensive care units. PATIENTS: Fifty-eight very preterm neonates (32 or less weeks PMA) receiving respiratory support and supplemental oxygen participating in an automated versus manual oxygen control cross-over trial. MAIN MEASURES: Extreme hypoxemia was defined as a SpO2 < 80%, extreme hyperoxemia as a SpO2 > 98%. Episode duration was categorized as < 5 seconds, between 5 to < 30 seconds, 30 to < 60 seconds, 60 to < 120 seconds, and 120 seconds or longer. RESULTS: The infants were of a median postmenstrual age of 29 (28-31) weeks, receiving a median FiO2 of 0.28 (0.25-0.32) with mostly receiving non-invasive respiratory support (83%). While most of the episodes were less than 30 seconds, longer episodes had a marked effect on total time exposure to extremes. The time differences in each of the three longest durations episodes (30, 60, and 120 seconds) were significantly less during automated than during manual control (p < 0.001). Nearly two-third of the reduction of total time spent at the extremes between automated and manual control (3.8 to 2.1% for < 80% SpO2 and 3.0 to 1.6% for > 98% SpO2) was seen in the episodes of at least 60 seconds. CONCLUSIONS: This study shows that the majority of episodes preterm infants spent in SpO2 extremes are of short duration regardless of manual or automated control. However, the infrequent longer episodes not only contribute the most to the total exposure, but also their reduction in frequency to the improvement associated with automated control.


Asunto(s)
Recien Nacido Prematuro , Oxígeno , Humanos , Hipoxia/etiología , Hipoxia/terapia , Lactante , Recién Nacido , Oximetría , Estudios Prospectivos , Estudios Retrospectivos
5.
Sensors (Basel) ; 22(11)2022 Jun 02.
Artículo en Inglés | MEDLINE | ID: mdl-35684858

RESUMEN

The reliability of pulse oximetry is crucial, especially in cases of rapid changes in body oxygenation. In order to evaluate the performance of pulse oximeters during rapidly developing short periods of concurrent hypoxemia and hypercapnia, 13 healthy volunteers underwent 3 breathing phases during outdoor experiments (39 phases in total), monitored simultaneously by five different pulse oximeters. A significant incongruity in values displayed by the tested pulse oximeters was observed, even when the accuracy declared by the manufacturers were considered. In 28.2% of breathing phases, the five used devices did not show any congruent values. The longest uninterrupted congruent period formed 74.4% of total recorded time. Moreover, the congruent periods were rarely observed during the critical desaturation phase of the experiment. The time difference between the moments when the first and the last pulse oximeter showed the typical study endpoint values of SpO2 85% and 75% was 32.1 ± 23.6 s and 24.7 ± 19.3 s, respectively. These results suggest that SpO2 might not be a reliable parameter as a study endpoint, or more importantly as a safety limit in outdoor experiments. In the design of future studies, more parameters and continuous clinical assessment should be included.


Asunto(s)
Oximetría , Oxígeno , Humanos , Hipoxia/diagnóstico , Monitoreo Fisiológico , Reproducibilidad de los Resultados
6.
BMC Pulm Med ; 21(1): 314, 2021 Oct 08.
Artículo en Inglés | MEDLINE | ID: mdl-34625059

RESUMEN

BACKGROUND: Diaphragm atrophy and dysfunction is a major problem among critically ill patients on mechanical ventilation. Ventilator-induced diaphragmatic dysfunction is thought to play a major role, resulting in a failure of weaning. Stimulation of the phrenic nerves and resulting diaphragm contraction could potentially prevent or treat this atrophy. The subject of this study is to determine the effectiveness of diaphragm stimulation in preventing atrophy by measuring changes in its thickness. METHODS: A total of 12 patients in the intervention group and 10 patients in the control group were enrolled. Diaphragm thickness was measured by ultrasound in both groups at the beginning of study enrollment (hour 0), after 24 hours, and at study completion (hour 48). The obtained data were then statistically analyzed and both groups were compared. RESULTS: The results showed that the baseline diaphragm thickness in the interventional group was (1.98 ± 0.52) mm and after 48 hours of phrenic nerve stimulation increased to (2.20 ± 0.45) mm (p=0.001). The baseline diaphragm thickness of (2.00 ± 0.33) mm decreased in the control group after 48 hours of mechanical ventilation to (1.72 ± 0.20) mm (p<0.001). CONCLUSIONS: Our study demonstrates that induced contraction of the diaphragm by pacing the phrenic nerve not only reduces the rate of its atrophy during mechanical ventilation but also leads to an increase in its thickness - the main determinant of the muscle strength required for spontaneous ventilation and successful ventilator weaning. TRIAL REGISTRATION: The study was registered with ClinicalTrials.gov (18/06/2018, NCT03559933, https://clinicaltrials.gov/ct2/show/NCT03559933 ).


Asunto(s)
Diafragma/fisiopatología , Terapia por Estimulación Eléctrica/métodos , Nervio Frénico/fisiología , Respiración Artificial/efectos adversos , Insuficiencia Respiratoria/terapia , Anciano , Enfermedad Crítica , Diafragma/diagnóstico por imagen , Terapia por Estimulación Eléctrica/instrumentación , Femenino , Humanos , Masculino , Persona de Mediana Edad , Atrofia Muscular/etiología , Atrofia Muscular/fisiopatología , Estudios Prospectivos , Respiración Artificial/métodos , Ultrasonografía
7.
Exp Lung Res ; 42(2): 87-94, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27070486

RESUMEN

UNLABELLED: Purpose/Aim : High-frequency oscillatory ventilation (HFOV) is a method of ventilation that theoretically achieves the goals of lung protective ventilation in acute respiratory distress syndrome (ARDS) patients. It is characterized by a rapid delivery of small tidal volumes at high frequencies oscillating around a continuous distending pressure (CDP). Optimization of CDP is not an easy task and it is titrated empirically in the clinical practice. The aim of this study is to investigate whether the level of CDP consistently affects the shape of the partial pressure of oxygen (PaO2) response to stepwise changes in CDP during HFOV of healthy and ARDS-induced pigs. MATERIALS AND METHODS: We performed two stepwise maneuvers of CDP in 14 pigs: one before and one after the lung lavage, inducing ARDS. For each CDP step performed, we fitted a segment of PaO2 curve with a one-term power model. RESULTS: PaO2 course follows shapes modeled by root, linear, quadratic, and cubic functions for values of PaO2 ≤ 110 mmHg and PaO2 ≤ 200 mmHg, before and after the lung lavage, respectively. PaO2 course follows a shape modeled exclusively by a root function for values of PaO2 > 110 mmHg and PaO2 > 200 mmHg, before and after the lung lavage, respectively. It is not possible to describe a relationship between the shape of the PaO2 course and the values of CDP. CONCLUSIONS: The PaO2 curve may give information about the level of recruitment of alveoli, but cannot be used for optimization of CDP level during HFOV in healthy and ARDS lung model pigs.


Asunto(s)
Oxígeno/metabolismo , Intercambio Gaseoso Pulmonar/fisiología , Síndrome de Dificultad Respiratoria/fisiopatología , Animales , Análisis de los Gases de la Sangre/métodos , Lavado Broncoalveolar/métodos , Modelos Animales de Enfermedad , Femenino , Ventilación de Alta Frecuencia/métodos , Presión , Respiración Artificial/métodos , Síndrome de Dificultad Respiratoria/metabolismo , Porcinos , Volumen de Ventilación Pulmonar/fisiología
8.
BMC Pulm Med ; 15: 65, 2015 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-26059111

RESUMEN

BACKGROUND: Heliox is a mixture of oxygen and helium which reduces airway resistance in patients with airway obstruction. In clinical practice, patients breathing spontaneously receive heliox via an open circuit. Recently, a semi-closed circuit for heliox administration has been proposed which minimizes consumption of heliox and therefore cost of the heliox therapy; although, the semi-closed circuit is associated with additional costs. The aim of the study is to conduct an economical analysis comparing total cost of heliox therapy using an open versus a semi-closed circuit in spontaneously breathing patients with airway obstruction. METHODS: Four different systems for heliox administration were analyzed: an open circuit and three alternatives of a semi-closed circuit involving a custom made semi-closed circuit and two standard anesthesia machines. Total costs of heliox therapy were calculated for all the systems. For calculation of gas consumption, the clinical procedures limiting continuous heliox therapy including the aerosol therapy, personal hygiene and nutrition were taken into account. A sensitivity analysis was conducted for main input variables that may influence the results of the study. RESULTS: Price of gases consumed by a semi-closed system represents less than 20 % of price of gases when a standard open circuit is used. This represents a saving of approximately 540 EUR per patient. The initial cost of the custom-made semi-closed circuit recuperates after treatment of 18 patients. The corresponding number of patients is 32 when a low-cost anesthesia machine is initially acquired and rises to 69 when a highly advanced anesthesia machine is considered. CONCLUSIONS: Heliox therapy in spontaneously breathing patients using a semi-closed circuit becomes more cost-effective compared to the open circuit, currently used in clinical practice, when applied in a sufficient number of cases. The impact of finding a cheaper way of heliox administration on the clinical practice needs to be ascertained.


Asunto(s)
Obstrucción de las Vías Aéreas/terapia , Anestesia por Circuito Cerrado/instrumentación , Helio/administración & dosificación , Oxígeno/administración & dosificación , Obstrucción de las Vías Aéreas/economía , Anestesia por Circuito Cerrado/economía , Costos y Análisis de Costo , Helio/economía , Humanos , Modelos Económicos , Oxígeno/economía
9.
Sci Rep ; 13(1): 7153, 2023 05 02.
Artículo en Inglés | MEDLINE | ID: mdl-37131058

RESUMEN

Scarcity of medical resources inspired many teams worldwide to design ventilators utilizing different approaches during the recent COVID-19 pandemic. Although it can be relatively easy to design a simple ventilator in a laboratory, a large scale production of reliable emergency ventilators which meet international standards for critical care ventilators is challenging and time consuming. The aim of this study is to propose a novel and easily manufacturable principle of gas mixing and inspiratory flow generation for mechanical lung ventilators. Two fast ON/OFF valves, one for air and one for oxygen, are used to control the inspiratory flow generation using pulse width modulation. Short gas flow pulses are smoothed by low-pass acoustic filters and do not propagate further into the patient circuit. At the same time, the appropriate pulse width modulation of both ON/OFF valves controls the oxygen fraction in the generated gas mixture. Tests focused on the accuracy of the delivered oxygen fractions and tidal volumes have proved compliance with the international standards for critical care ventilators. The concept of a simple construction using two fast ON/OFF valves may be used for designing mechanical lung ventilators and thus suitable for their rapid production during pandemics.


Asunto(s)
COVID-19 , Incidentes con Víctimas en Masa , Humanos , Pandemias , COVID-19/terapia , Ventiladores Mecánicos , Cuidados Críticos , Oxígeno
10.
Measur Sens ; 22: 100383, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36721675

RESUMEN

At the time of COVID-19 pandemic onset in spring 2020 a project CoroVent was initiated with the aim to design and produce emergency lung ventilators and distribute them to hospitals. No flow and tidal volume sensors were available for the project. The lack of tidal volume sensors was a consequence of the rapidly increased demand for mechanical lung ventilators and their consumables. The aim of the study was to develop a special flow sensor CoroQuant for the CoroVent ventilators. The sensor based on pneumotachographic principle, manufactured by the plastic injection moulding of polypropylene, meets the requirements for precision of tidal volume measurement defined by international standard ISO 80601-2-12 for mechanical lung ventilators. CoroVent ventilators with CoroQuant sensors were distributed to 27 hospitals in the Czech Republic for free upon the requests from the medical facilities and started to be clinically used, thus preventing lack of lung ventilators in hospitals in the Czech Republic.

11.
Diagnostics (Basel) ; 12(9)2022 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-36140483

RESUMEN

Dynamic hyperinflation is reported as a potential risk during high-frequency oscillatory ventilation (HFOV), and its existence has been documented both by physical models and by CT. The aim of this study is to determine the suitability of electrical impendence tomography (EIT) for the measurement of dynamic lung hyperinflation and hypoinflation during HFOV. Eleven healthy pigs were anaesthetized and ventilated using HFOV. The difference between the airway pressure at the airway opening and alveolar space was measured by EIT and esophageal balloons at three mean airway pressures (12, 18 and 24 cm H2O) and two inspiratory to expiratory time ratios (1:1, 1:2). The I:E ratio was the primary parameter associated with differences between airway and alveolar pressures. All animals showed hyperinflation at a 1:1 ratio (median 1.9 cm H2O) and hypoinflation at a 1:2 (median -4.0 cm H2O) as measured by EIT. EIT measurements had a linear correlation to esophageal balloon measurements (r2 = -0.915, p = 0.0085). EIT measurements were slightly higher than that of the esophageal balloon transducer with the mean difference of 0.57 cm H2O. Presence of a hyperinflation or hypoinflation was also confirmed independently by chest X-ray. We found that dynamic hyperinflation developed during HFOV may be detected and characterized noninvasively by EIT.

12.
Sci Rep ; 12(1): 2070, 2022 02 08.
Artículo en Inglés | MEDLINE | ID: mdl-35136116

RESUMEN

Outdoor breathing trials with simulated avalanche snow are fundamental for the research of the gas exchange under avalanche snow, which supports the development of the international resuscitation guidelines. However, these studies have to face numerous problems, including unstable weather and variable snow properties. This pilot study examines a mineral material perlite as a potential snow model for studies of ventilation and gas exchange parameters. Thirteen male subjects underwent three breathing phases-into snow, wet perlite and dry perlite. The resulting trends of gas exchange parameters in all tested materials were similar and when there was a significant difference observed, the trends in the parameters for high density snow used in the study lay in between the trends in dry and wet perlite. These findings, together with its stability and accessibility year-round, make perlite a potential avalanche snow model material. Perlite seems suitable especially for simulation and preparation of breathing trials assessing gas exchange under avalanche snow, and potentially for testing of new avalanche safety equipment before their validation in real snow.The study was registered in ClinicalTrials.gov on January 22, 2018; the registration number is NCT03413878.


Asunto(s)
Óxido de Aluminio , Avalanchas , Intercambio Gaseoso Pulmonar/fisiología , Respiración , Dióxido de Silicio , Nieve , Adulto , Reanimación Cardiopulmonar/métodos , Estudios Cruzados , República Checa , Método Doble Ciego , Humanos , Masculino , Modelos Teóricos , Proyectos Piloto , Estudios Prospectivos , Entrenamiento Simulado , Adulto Joven
13.
J Crit Care ; 59: 76-80, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32570053

RESUMEN

PURPOSE: In patients with pleural effusion (PLE) monitored by Electrical Impedance Tomography (EIT) an increase in end-expiratory lung impedance (EELI) is observed following evacuation of the PLE. We aimed at differentiating the effect of fluid removal from lung reaeration and describe the change in ventilation distribution. MATERIALS AND METHODS: Mechanically ventilated patients were monitored by EIT during PLE evacuation. End-expiratory lung volume (EELV) was measured concurrently. We included a calibration maneuver consisting of an increase in positive end-expiratory pressure (PEEP) by 5 cm H2O. The ratio ΔEELI/ΔEELV was used to compare changes of EELI and EELV in response to the calibration maneuver and PLE evacuation. At the same time we assessed distribution of ventilation using changes in tidal variation. RESULTS: PLE removal resulted in a 6-fold greater increase in ΔEELI/ΔEELV when compared to the calibration maneuver (r = 0.84, p < .05). We observed a relative increase in ventilation in the area of the effusion (mean 7.1%, p < .006) and an overall shift of ventilation to the dorsal fraction of the lungs (mean 8%, p < .0002). CONCLUSIONS: The increase in EELI in the EIT image after PLE removal was primarily due to the removal of the conductive effusion fluid.


Asunto(s)
Drenaje/métodos , Impedancia Eléctrica , Derrame Pleural/terapia , Respiración con Presión Positiva/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Hospitales Militares , Hospitales Universitarios , Humanos , Unidades de Cuidados Intensivos , Pulmón/fisiología , Masculino , Persona de Mediana Edad , Proyectos Piloto , Estudios Prospectivos , Volumen de Ventilación Pulmonar , Resultado del Tratamiento
14.
Crit Care Med ; 37(3): 1068-73, 2009 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19237919

RESUMEN

OBJECTIVE: Maintenance breathing is advocated in mechanical ventilation, which is difficult for the high-frequency oscillatory (HFO) ventilation. To facilitate spontaneous breathing during HFO ventilation, a demand flow system (DFS) was designed. The aim of the present study was to evaluate the system. DESIGN: Animal experiment. SETTING: : University animal laboratory. SUBJECTS: Eight pigs (47-64 kg). INTERVENTIONS: Lung injury was induced by lung lavage with normal saline. After spontaneous breathing was restored HFO ventilation was applied, in runs of 30 minutes, with continuous fresh gas flow (CF) or the DFS operated in two different setups. Pressure to regulate the DFS was sampled directly at the Y-piece of the ventilator circuit (DFS) or between the endotracheal tube and measurement equipment at the proximal end of the endotracheal tube. In the end, animals were paralyzed. Breathing pattern, work of breathing, and gas exchange were evaluated. MEASUREMENTS AND MAIN RESULTS: HFO ventilation with demand flow decreased breathing frequency and increased tidal volume compared with CF. Comparing HFO modes CF, DFS, and DFSPROX, total pressure-time product (PTP) was 66 cm H2O x sec x min (interquartile range 59-74), 64 cm H2O x sec x min (50-72), and 51 cm H2O x sec x min (41-63). Ventilator PTP was 36 cm H2O x sec x min (32-42), 8.6 cm H2O x sec x min (7.4-10), and 1 cm H2O x sec x min (-1.0 to 2.8). Oxygenation, evaluated by Pao2, was preserved when spontaneous breathing was maintained and deteriorated when pigs were paralyzed. Ventilation, evaluated by Paco2, improved with demand flow. Paco2 increased when using continuous flow and during muscular paralysis. CONCLUSIONS: In moderately lung-injured anesthetized pigs during HFO ventilation, demand flow facilitated spontaneous breathing and augmented gas exchange. Demand flow decreased total breathing effort as quantified by PTP. Imposed work caused by the HFO ventilator appeared totally reduced by demand flow.


Asunto(s)
Lesión Pulmonar Aguda/terapia , Ventilación de Alta Frecuencia , Respiración , Lesión Pulmonar Aguda/fisiopatología , Animales , Modelos Animales , Porcinos
15.
Sci Rep ; 9(1): 5775, 2019 04 08.
Artículo en Inglés | MEDLINE | ID: mdl-30962469

RESUMEN

Electrical impedance tomography (EIT) is a noninvasive imaging modality that allows real-time monitoring of regional lung ventilation. The aim of the study is to investigate whether fast saline infusion causes changes in lung impedance that could affect the interpretation of EIT data. Eleven pigs were anaesthetized and mechanically ventilated. A bolus of 500 mL of normal saline was administered rapidly. Two PEEP steps were performed to allow quantification of the effect of normal saline on lung impedance. The mean change of end-expiratory lung impedance (EELI) caused by the saline bolus was equivalent to a virtual decrease of end-expiratory lung volume (EELV) by 227 (188-250) mL and decremental PEEP step of 4.40 (3.95-4.59) cmH2O (median and interquartile range). In contrast to the changes of PEEP, the administration of normal saline did not cause any significant differences in measured EELV, regional distribution of lung ventilation determined by EIT or in extravascular lung water and intrathoracic blood volume. In conclusion, EELI can be affected by the changes of EELV as well as by the administration of normal saline. These two phenomena can be distinguished by analysis of regional distribution of lung ventilation.


Asunto(s)
Artefactos , Impedancia Eléctrica , Pulmón/diagnóstico por imagen , Solución Salina/administración & dosificación , Tomografía/normas , Animales , Femenino , Infusiones Intravenosas/efectos adversos , Pulmón/fisiología , Solución Salina/efectos adversos , Porcinos , Volumen de Ventilación Pulmonar , Tomografía/métodos
16.
Artículo en Inglés | MEDLINE | ID: mdl-29467544

RESUMEN

BACKGROUND AND AIMS: During laparoscopic surgery, a capnoperitoneum is created to optimize the operating space for surgeons. One effect of this is abdominal pressure which alters the physiological thoraco-abdominal configuration and pushes the diaphragm and lungs cranially. Since the lung image acquired by electrical impedance tomography (EIT) depends on the conditions within the thorax and abdomen, it is crucial to know the diaphragm position to determine the effect of diaphragm shift on EIT thorax image. METHODS: The presence of diaphragm in the region of EIT measurement was determined by ultrasound in 20 patients undergoing laparoscopic surgery. Data were obtained in the supine position during spontaneous breathing in a mechanically ventilated patient under general anesthesia with muscle relaxation and in a mechanically ventilated patient under general anesthesia with muscle relaxation during capnoperitoneum. RESULTS: The diaphragm was shifted cranially during capnoperitoneum. The diaphragm detection rate rose by 10% during capnoperitoneum at the fifth intercostal space, from 55% to 65% and by 10% from 0% at mid-sternal level compared to mechanical ventilation without capnoperitoneum. CONCLUSION: The diaphragm was detected in the area contributing to the creation of the thoracic EIT image. Considering the cranial shift of diaphragm caused by excessive intra-abdominal pressure, the impedance changes in the abdomen and the principle of EIT, we assume there could be a significant impact on EIT image of the thorax acquired during capnoperitoneum. For this reason, for lung monitoring using EIT during capnoperitoneum, the manufacturer's recommendation for electrode belt position is not appropriate. The study was registered in ClinicalTrials.gov with an identifier NCT03038061.


Asunto(s)
Diafragma/diagnóstico por imagen , Impedancia Eléctrica , Laparoscopía , Pulmón/diagnóstico por imagen , Neumoperitoneo Artificial/métodos , Tórax/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Respiración con Presión Positiva , Estudios Prospectivos , Reproducibilidad de los Resultados
17.
Biomed Tech (Berl) ; 63(6): 647-655, 2018 Nov 27.
Artículo en Inglés | MEDLINE | ID: mdl-28802098

RESUMEN

Noninvasive techniques are routinely used for assessment of tissue effects of lung ventilation. However, comprehensive studies of the response time of the methods are scarce. The aim of this study was to compare the response time of noninvasive methods for monitoring of gas exchange to sudden changes in the composition of the inspired gas. A prospective experimental study with 16 healthy volunteers was conducted. A ventilation circuit was designed that enabled a fast change in the composition of the inspiratory gas mixture while allowing spontaneous breathing. The volunteers inhaled a hypoxic mixture, then a hypercapnic mixture, a hyperoxic mixture and finally a 0.3% CO mixture. The parameters with the fastest response to the sudden change of O2 in inhaled gas were peripheral capillary oxygen saturation (SpO2) and regional tissue oxygenation (rSO2). Transcutaneous oxygen partial pressure (tcpO2) had almost the same time of reaction, but its time of relaxation was 2-3 times longer. End-tidal carbon dioxide (EtCO2) response time to change of CO2 concentration in inhaled gas was less than half in comparison with transcutaneous carbon dioxide partial pressure (tcpCO2). All the examined parameters and devices reacted adequately to changes in gas concentration in the inspiratory gas mixture.


Asunto(s)
Monitoreo de Gas Sanguíneo Transcutáneo/métodos , Dióxido de Carbono/química , Respiración Artificial/métodos , Humanos , Oximetría , Tiempo de Reacción
18.
Crit Care ; 10(4): R103, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-16848915

RESUMEN

INTRODUCTION: With the 3100B high-frequency oscillatory ventilator (SensorMedics, Yorba Linda, CA, USA), patients' spontaneous breathing efforts result in a high level of imposed work of breathing (WOB). Therefore, spontaneous breathing often has to be suppressed during high-frequency oscillatory ventilation (HFOV). A demand-flow system was designed to reduce imposed WOB. METHODS: An external gas flow controller (demand-flow system) accommodates the ventilator fresh gas flow during spontaneous breathing simulation. A control algorithm detects breathing effort and regulates the demand-flow valve. The effectiveness of this system has been evaluated in a bench test. The Campbell diagram and pressure time product (PTP) are used to quantify the imposed workload. RESULTS: Using the demand-flow system, imposed WOB is considerably reduced. The demand-flow system reduces inspiratory imposed WOB by 30% to 56% and inspiratory imposed PTP by 38% to 59% compared to continuous fresh gas flow. Expiratory imposed WOB was decreased as well by 12% to 49%. In simulations of shallow to normal breathing for an adult, imposed WOB is 0.5 J l-1 at maximum. Fluctuations in mean airway pressure on account of spontaneous breathing are markedly reduced. CONCLUSION: The use of the demand-flow system during HFOV results in a reduction of both imposed WOB and fluctuation in mean airway pressure. The level of imposed WOB was reduced to the physiological range of WOB. Potentially, this makes maintenance of spontaneous breathing during HFOV possible and easier in a clinical setting. Early initiation of HFOV seems more possible with this system and the possibility of weaning of patients directly on a high-frequency oscillatory ventilator is not excluded either.


Asunto(s)
Ventilación de Alta Frecuencia/instrumentación , Ventilación de Alta Frecuencia/métodos , Modelos Biológicos , Trabajo Respiratorio/fisiología , Mecánica Respiratoria/fisiología
19.
Crit Care ; 10(1): R23, 2006 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-16469130

RESUMEN

INTRODUCTION: The ventilator and the endotracheal tube impose additional workload in mechanically ventilated patients breathing spontaneously. The total work of breathing (WOB) includes elastic and resistive work. In a bench test we assessed the imposed WOB using 3100 A/3100 B SensorMedics high-frequency oscillatory ventilators. METHODS: A computer-controlled piston-driven test lung was used to simulate a spontaneously breathing patient. The test lung was connected to a high-frequency oscillatory ventilation (HFOV) ventilator by an endotracheal tube. The inspiratory and expiratory airway flows and pressures at various places were sampled. The spontaneous breath rate and volume, tube size and ventilator settings were simulated as representative of the newborn to adult range. The fresh gas flow rate was set at a low and a high level. The imposed WOB was calculated using the Campbell diagram. RESULTS: In the simulations for newborns (assumed body weight 3.5 kg) and infants (assumed body weight 10 kg) the imposed WOB (mean +/- standard deviation) was 0.22 +/- 0.07 and 0.87 +/- 0.25 J/l, respectively. Comparison of the imposed WOB in low and high fresh gas flow rate measurements yielded values of 1.63 +/- 0.32 and 0.96 +/- 0.24 J/l (P = 0.01) in small children (assumed body weight 25 kg), of 1.81 +/- 0.30 and 1.10 +/- 0.27 J/l (P < 0.001) in large children (assumed body weight 40 kg), and of 1.95 +/- 0.31 and 1.12 +/- 0.34 J/l (P < 0.01) in adults (assumed body weight 70 kg). High peak inspiratory flow and low fresh gas flow rate significantly increased the imposed WOB. Mean airway pressure in the breathing circuit decreased dramatically during spontaneous breathing, most markedly at the low fresh gas flow rate. This led to ventilator shut-off when the inspiratory flow exceeded the fresh gas flow. CONCLUSION: Spontaneous breathing during HFOV resulted in considerable imposed WOB in pediatric and adult simulations, explaining the discomfort seen in those patients breathing spontaneously during HFOV. The level of imposed WOB was lower in the newborn and infant simulations, explaining why these patients tolerate spontaneous breathing during HFOV well. A high fresh gas flow rate reduced the imposed WOB. These findings suggest the need for a demand flow system based on patient need allowing spontaneous breathing during HFOV.


Asunto(s)
Simulación por Computador , Ventilación de Alta Frecuencia/métodos , Trabajo Respiratorio , Proyectos de Investigación , Trabajo Respiratorio/fisiología
20.
PLoS One ; 10(12): e0144332, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26666523

RESUMEN

Presence of an air pocket and its size play an important role in survival of victims buried in the avalanche snow. Even small air pockets facilitate breathing. We hypothesize that the size of the air pocket significantly affects the airflow resistance and work of breathing. The aims of the study are (1) to investigate the effect of the presence of an air pocket on gas exchange and work of breathing in subjects breathing into the simulated avalanche snow and (2) to test whether it is possible to breathe with no air pocket. The prospective interventional double-blinded study involved 12 male volunteers, from which 10 completed the whole protocol. Each volunteer underwent two phases of the experiment in a random order: phase "AP"--breathing into the snow with a one-liter air pocket, and phase "NP"--breathing into the snow with no air pocket. Physiological parameters, fractions of oxygen and carbon dioxide in the airways and work of breathing expressed as pressure-time product were recorded continuously. The main finding of the study is that it is possible to breath in the avalanche snow even with no air pocket (0 L volume), but breathing under this condition is associated with significantly increased work of breathing. The significant differences were initially observed for end-tidal values of the respiratory gases (EtO2 and EtCO2) and peripheral oxygen saturation (SpO2) between AP and NP phases, whereas significant differences in inspiratory fractions occurred much later (for FIO2) or never (for FICO2). The limiting factor in no air pocket conditions is excessive increase in work of breathing that induces increase in metabolism accompanied by higher oxygen consumption and carbon dioxide production. The presence of even a small air pocket reduces significantly the work of breathing.


Asunto(s)
Asfixia/fisiopatología , Avalanchas , Desastres , Hipercapnia/fisiopatología , Hipoxia/fisiopatología , Trabajo Respiratorio/fisiología , Adulto , Asfixia/prevención & control , Dióxido de Carbono/fisiología , Estudios Cruzados , Método Doble Ciego , Voluntarios Sanos , Humanos , Volumen de Reserva Inspiratoria/fisiología , Masculino , Monitoreo Fisiológico , Oxígeno/fisiología , Nieve , Volumen de Ventilación Pulmonar/fisiología