1.
PLoS One ; 9(1): e81920, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24416133

RESUMEN

Seizure forecasting has the potential to create new therapeutic strategies for epilepsy, such as providing patient warnings and delivering preemptive therapy. Progress on seizure forecasting, however, has been hindered by lack of sufficient data to rigorously evaluate the hypothesis that seizures are preceded by physiological changes, and are not simply random events. We investigated seizure forecasting in three dogs with naturally occurring focal epilepsy implanted with a device recording continuous intracranial EEG (iEEG). The iEEG spectral power in six frequency bands: delta (0.1-4 Hz), theta (4-8 Hz), alpha (8-12 Hz), beta (12-30 Hz), low-gamma (30-70 Hz), and high-gamma (70-180 Hz), were used as features. Logistic regression classifiers were trained to discriminate labeled pre-ictal and inter-ictal data segments using combinations of the band spectral power features. Performance was assessed on separate test data sets via 10-fold cross-validation. A total of 125 spontaneous seizures were detected in continuous iEEG recordings spanning 6.5 to 15 months from 3 dogs. When considering all seizures, the seizure forecasting algorithm performed significantly better than a Poisson-model chance predictor constrained to have the same time in warning for all 3 dogs over a range of total warning times. Seizure clusters were observed in all 3 dogs, and when the effect of seizure clusters was decreased by considering the subset of seizures separated by at least 4 hours, the forecasting performance remained better than chance for a subset of algorithm parameters. These results demonstrate that seizures in canine epilepsy are not randomly occurring events, and highlight the feasibility of long-term seizure forecasting using iEEG monitoring.


Asunto(s)
Enfermedades de los Perros/diagnóstico , Convulsiones/veterinaria , Animales , Perros , Electrodos Implantados , Electroencefalografía , Convulsiones/diagnóstico , Factores de Tiempo
2.
Lancet Neurol ; 12(6): 563-71, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23642342

RESUMEN

BACKGROUND: Seizure prediction would be clinically useful in patients with epilepsy and could improve safety, increase independence, and allow acute treatment. We did a multicentre clinical feasibility study to assess the safety and efficacy of a long-term implanted seizure advisory system designed to predict seizure likelihood and quantify seizures in adults with drug-resistant focal seizures. METHODS: We enrolled patients at three centres in Melbourne, Australia, between March 24, 2010, and June 21, 2011. Eligible patients had between two and 12 disabling partial-onset seizures per month, a lateralised epileptogenic zone, and no history of psychogenic seizures. After devices were surgically implanted, patients entered a data collection phase, during which an algorithm for identification of periods of high, moderate, and low seizure likelihood was established. If the algorithm met performance criteria (ie, sensitivity of high-likelihood warnings greater than 65% and performance better than expected through chance prediction of randomly occurring events), patients then entered an advisory phase and received information about seizure likelihood. The primary endpoint was the number of device-related adverse events at 4 months after implantation. Our secondary endpoints were algorithm performance at the end of the data collection phase, clinical effectiveness (measures of anxiety, depression, seizure severity, and quality of life) 4 months after initiation of the advisory phase, and longer-term adverse events. This trial is registered with ClinicalTrials.gov, number NCT01043406. FINDINGS: We implanted 15 patients with the advisory system. 11 device-related adverse events were noted within four months of implantation, two of which were serious (device migration, seroma); an additional two serious adverse events occurred during the first year after implantation (device-related infection, device site reaction), but were resolved without further complication. The device met enabling criteria in 11 patients upon completion of the data collection phase, with high likelihood performance estimate sensitivities ranging from 65% to 100%. Three patients' algorithms did not meet performance criteria and one patient required device removal because of an adverse event before sufficient training data were acquired. We detected no significant changes in clinical effectiveness measures between baseline and 4 months after implantation. INTERPRETATION: This study showed that intracranial electroencephalographic monitoring is feasible in ambulatory patients with drug-resistant epilepsy. If these findings are replicated in larger, longer studies, accurate definition of preictal electrical activity might improve understanding of seizure generation and eventually lead to new management strategies. FUNDING: NeuroVista.


Asunto(s)
Electrodos Implantados , Electroencefalografía/instrumentación , Convulsiones/diagnóstico , Convulsiones/fisiopatología , Adulto , Electroencefalografía/métodos , Epilepsia/diagnóstico , Epilepsia/fisiopatología , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Monitoreo Fisiológico/instrumentación , Monitoreo Fisiológico/métodos , Valor Predictivo de las Pruebas , Estudios Prospectivos , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
3.
Epilepsy Res ; 96(1-2): 116-22, 2011 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-21676591

RESUMEN

We present results from continuous intracranial electroencephalographic (iEEG) monitoring in 6 dogs with naturally occurring epilepsy, a disorder similar to the human condition in its clinical presentation, epidemiology, electrophysiology and response to therapy. Recordings were obtained using a novel implantable device wirelessly linked to an external, portable real-time processing unit. We demonstrate previously uncharacterized intracranial seizure onset patterns in these animals that are strikingly similar in appearance to human partial onset epilepsy. We propose: (1) canine epilepsy as an appropriate model for testing human antiepileptic devices and new approaches to epilepsy surgery, and (2) this new technology as a versatile platform for evaluating seizures and response to therapy in the natural, ambulatory setting.


Asunto(s)
Electrodos Implantados , Electroencefalografía/instrumentación , Electroencefalografía/métodos , Epilepsia/diagnóstico , Telemetría/instrumentación , Algoritmos , Animales , Anticonvulsivantes/farmacología , Anticonvulsivantes/uso terapéutico , Perros , Epilepsia/tratamiento farmacológico , Epilepsia/fisiopatología , Epilepsia/veterinaria , Femenino , Masculino , Monitoreo Fisiológico , Telemetría/métodos , Vigilia