RESUMEN
PURPOSE: To demonstrate that strategic use of materials with high electric permittivity along with integrated head-sized coil arrays can improve SNR in the entire brain. METHODS: Numerical simulations were used to design a high-permittivity material (HPM) helmet for enhancing SNR throughout the brain in receive arrays of 8 and 28 channels. Then, two 30-channel head coils of identical geometry were constructed: one fitted with a prototype helmet-shaped ceramic HPM helmet, and the second with a helmet-shaped low-permittivity shell, each 8-mm thick. An eight-channel dipole array was used for excitation. In vivo maps of excitation flip angle and SNR were acquired. RESULTS: Simulation results showed improvement in transmit efficiency by up to 65% and in receive-side SNR by up to 47% on average through the head with use of an HPM helmet. Experimental results showed that experimental transmit efficiency was improved by approximately 56% at the center of brain, and experimental receive-side SNR (SNR normalized to flip angle) was improved by approximately 21% on average through orthogonal planes through the cerebrum, including at the center of the brain, with the HPM. CONCLUSION: Although HPM is used increasingly to improve transmit efficiency locally in situations in which the transmit coil and imaging volume are much larger than the HPM, here we demonstrate that HPM can also be used to improve transmit efficiency and receive-side SNR throughout the brain by improving performance of a head-sized receive array. This includes the center of the brain, where it is difficult to improve SNR by other means.
Asunto(s)
Imagen por Resonancia Magnética , Ondas de Radio , Encéfalo/diagnóstico por imagen , Diseño de Equipo , Fantasmas de Imagen , Relación Señal-RuidoRESUMEN
PURPOSE: To present a 3T brain imaging study using a conformal prototype helmet constructed with an ultra-high dielectric constant (uHDC; εr ~ 1000) materials that can be inserted into standard receive head-coils. METHODS: A helmet conformal to a standard human head constructed with uHDC materials was characterized through electromagnetic simulations and experimental work. The signal-to-noise ratio (SNR), transmit efficiency, and power deposition with the uHDC helmet inserted within a 20-channel head coil were measured in vivo and compared with a 64-channel head coil and the 20-channel coil without the helmet. Seven healthy volunteers were analyzed. RESULTS: Simulation and in vivo experimental results showed that transmit efficiency was improved by nearly 3 times within localized regions for a quadrature excitation, with a measured global increase of 58.21 ± 6.54% over 7 volunteers. The use of a parallel transmit spokes pulse compensated for severe degradation of B1+ homogeneity, at the expense of higher global and local specific absorption rate levels. A SNR histogram analysis with statistical testing demonstrated that the uHDC helmet enhanced a 20-channel head coil to the level of the 64-channel head coil, with the improvements mainly within the cortical brain regions. CONCLUSION: A prototype uHDC helmet enhanced the SNR of a standard head coil to the level of a high density 64-channel coil, although transmit homogeneity was compromised. Further improvements in SNR may be achievable with optimization of this technology, and could be a low-cost approach for future radiofrequency engineering work in the brain at 3T.
Asunto(s)
Encéfalo/diagnóstico por imagen , Corteza Cerebral/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética , Posicionamiento del Paciente/instrumentación , Fantasmas de Imagen , Algoritmos , Mapeo Encefálico , Simulación por Computador , Radiación Electromagnética , Femenino , Voluntarios Sanos , Humanos , Neuroimagen , Posicionamiento del Paciente/métodos , Ondas de Radio , Reproducibilidad de los Resultados , Relación Señal-RuidoRESUMEN
PURPOSE: Incorporating high dielectric constant (HDC) materials into radiofrequency (RF) coils has been shown to effectively improve RF coil performance at 7 and 3 T because of the induced displacement current in the high dielectric constant materials. The displacement current is proportional to the RF field frequency and permittivity of the material. The aim of this paper is to investigate the effect of high dielectric constant materials with even greater permittivity on the RF field at 1.5 T and 3 T. METHODS: Several monolithic ceramic materials with an ultrahigh dielectric constant ranging from 1200 to 3300 were investigated at 1.5 T and 3 T with phantom and human brain imaging along with computer modeling. RESULTS: Experimental measurements in phantom studies showed a significant enhancement of signal-to-noise ratio (50-100%) and strong transmission power reduction (3-27-fold). Under suboptimal experimental conditions in this study, the signal-to-noise ratio in the human brain cortex was nearly doubled, which produced high-resolution image without the associated stronger magnetic susceptibility artifacts and elevated specific absorption rate concerns at higher field strengths. CONCLUSIONS: Use of ultrahigh dielectric constant ceramic materials is a simple and low-cost approach that could further improve the RF technology to maximize image signal-to-noise ratio and reduce RF energy deposition for human studies. Magn Reson Med 79:2842-2851, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Asunto(s)
Cerámica/química , Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/métodos , Encéfalo/diagnóstico por imagen , Diseño de Equipo , Humanos , Masculino , Fantasmas de Imagen , Relación Señal-RuidoRESUMEN
PURPOSE: To investigate the use of a new high-dielectric constant (HDC) material for improving SNR and transmission efficiency for clinical MRI applications at 3 Tesla (T) with cervical spine imaging. MATERIALS AND METHODS: Human subjects were imaged using a commercial cervical spine receive array coil on a clinical system with and without pads containing Barium Titanate beads in deuterium water placed around the neck. Numerical electromagnetic field simulations of the same configuration were also performed. RESULTS: Experimental and simulated maps of transmit and receive fields showed greater efficiency for imaging the cervical spine when the pads were present. Experimental measurements showed a significant improvement in SNR with the pads present and an average input power reduction of 46%. CONCLUSION: Use of HDC material can enhance SNR and transmission efficiency for clinical imaging of the cervical spine at 3.0T.
Asunto(s)
Vértebras Cervicales/anatomía & histología , Aumento de la Imagen/instrumentación , Imagen por Resonancia Magnética/instrumentación , Magnetismo/instrumentación , Transductores , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Ondas de Radio , Reproducibilidad de los Resultados , Sensibilidad y EspecificidadRESUMEN
This work introduces an innovative magnetic resonance (MR) imaging technology that incorporates radiofrequency (RF) coil(s) with permittivity-tunable ultrahigh dielectric constant (tuHDC) ceramics to significantly improve RF coil transmission and reception efficiencies, MR imaging sensitivity and signal-to-noise ratio (SNR). The tuHDC ceramics made of composite barium strontium titanate (BST) compounds (Ba0.6 Sr0.4 TiO3) have low dielectric loss and very high permittivity tunability from 2,000 to 15000 by varying the ceramic temperature between 0°C and 40°C to achieve an optimal permittivity for MR imaging application. We demonstrated for the first time the proof of concept using the BST-based tuHDC-RF-coil technology to improve MR spectroscopic imaging performance of 17O nuclide at 10.5 Tesla (T) at a low ceramic temperature and 23Na nuclide at 7T at room temperature. We discovered a large and spatially independent noise reduction under an optimal ceramic temperature, which synergistically resulted in an unprecedented SNR improvement. Large improvements were also demonstrated for 1H MRI on a 1.5T clinical scanner using the same ceramics. The tuHDC-RF-coil technology is robust, flexible and cost-effective; it presents a technical breakthrough to significantly improve imaging sensitivity and resolution for broad MR imaging applications; which is critical for advancing biomedical and neuroscience research, and improving diagnostic imaging.
Asunto(s)
Imagen por Resonancia Magnética , Ondas de Radio , Cerámica , Diseño de Equipo , Fantasmas de Imagen , Relación Señal-RuidoRESUMEN
BACKGROUND: Public health concerns over the addictive potential of electronic cigarettes (e-cigs) have heightened in recent years. Brain function during e-cig use could provide an objective measure of the addictive potential of new vaping products to facilitate research; however, there are limited methods for delivering e-cig aerosols during functional magnetic resonance imaging (fMRI). The current study describes the development and feasibility testing of a prototype to deliver up to four different e-cig aerosols during fMRI. METHODS: Standardized methods were used to test the devices' air flow variability, nicotine yield, and free radical production. MRI scans were run with and without the device present to assess its safety and effects on MRI data quality. Five daily smokers were recruited to assess plasma nicotine absorption from e-liquids containing nicotine concentrations of 8, 11, 16, 24, and 36 mg/ml. Feedback was collected from participants through a semi-structured interview and computerized questionnaire to assess comfort and subjective experiences of inhaling aerosol from the device. RESULTS: Nicotine yield captured from the aerosol produced by the device was highly correlated with the nicotine concentration of the e-liquids used (R2 = 0.965). Nicotine yield was reduced by a mean of 48% and free radical production by 17% after traveling through the device. The e-liquid containing the highest nicotine concentration tested (36 mg/ml) resulted in the highest plasma nicotine boost (6.6 ng/ml). Overall, participants reported that the device was comfortable to use and inhaling the e-cig aerosols was tolerable. The device was determined to be safe for use during fMRI and had insignificant effects on scan quality. CONCLUSIONS: With the current project, we were able to design a working prototype that safely and effectively delivers e-cig aerosols during fMRI. The device has the potential to be used to assess brain activation during e-cig use and to compare brain reactivity to varying flavors, nicotine concentrations, and other e-cig characteristics.
RESUMEN
OBJECTIVEIntracranial aneurysms are vascular abnormalities associated with neurological morbidity and mortality due to risk of rupture. In addition, many aneurysm treatments have associated risk profiles that can preclude the prophylactic treatment of asymptomatic lesions. Gamma Knife radiosurgery (GKRS) is a standard treatment for trigeminal neuralgia, tumors, and arteriovenous malformations. Aneurysms associated with arteriovenous malformations have been noted to resolve after treatment of the malformation. The aim of this study was to determine the efficacy of GKRS treatment in a saccular aneurysm animal model.METHODSAneurysms were surgically produced using an elastase-induced aneurysm model in the right common carotid artery of 10 New Zealand white rabbits. Following initial observation for 4 years, each rabbit aneurysm was treated with a conformal GKRS isodose of 25 Gy to the 50% margin. Longitudinal MRI studies obtained over 2 years and terminal measures obtained at multiple time points were used to track aneurysm size and shape index modifications.RESULTSAneurysms did not rupture or involute during the observation period. Whole aneurysm and blood volume averages decreased with a linear trend, at rates of 1.7% and 1.6% per month, respectively, over 24 months. Aneurysm wall percent volume increased linearly at a rate of 0.3% per month, indicating a relative thickening of the aneurysm wall during occlusion. Nonsphericity of the average volume, aspect ratio, and isoperimetric ratio of whole aneurysm volume all remained constant. Histopathological samples demonstrated progressive reduction in aneurysm size and wall thickening, with subintimal fibrosis. Consistent shape indices demonstrate stable aneurysm patency and maintenance of minimal rupture risk following treatment.CONCLUSIONSThe data indicate that GKRS targeted to saccular aneurysms is associated with histopathological changes and linear reduction of aneurysm size over time. The results suggest that GKRS may be a viable, minimally invasive treatment option for intracranial aneurysm obliteration.
Asunto(s)
Aneurisma/radioterapia , Radiocirugia/instrumentación , Aneurisma/diagnóstico por imagen , Animales , Modelos Animales de Enfermedad , Imagen por Resonancia Magnética , Masculino , Conejos , Resultado del TratamientoRESUMEN
The study of human olfaction is a highly complex and valuable field with applications ranging from biomedical research to clinical evaluation. Currently, evaluation of the functions of the human central olfactory system with functional magnetic resonance imaging (fMRI) is still a challenge because of several technical difficulties. There are some significant variables to take into account when considering an effective method for mapping the function of the central olfactory system using fMRI, including proper odorant selection, the interaction between odor presentation and respiration, and potential anticipation of or habituation to odorants. An event-related, respiration-triggered olfactory fMRI technique can accurately administer odorants to stimulate the olfactory system while minimizing potential interference. It can effectively capture the precise onsets of fMRI signals in the primary olfactory cortex using our data post-processing method. The technique presented here provides an efficient and practical means for generating reliable olfactory fMRI results. Such a technique can ultimately be applied in the clinical realm as a diagnostic tool for diseases associated with olfactory degeneration, including Alzheimer's and Parkinson's disease, as we begin to further understand the complexities of the human olfactory system.
Asunto(s)
Encéfalo/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Odorantes , Mapeo Encefálico , Humanos , Odorantes/análisis , Vías Olfatorias , Respiración , Grabación en VideoRESUMEN
In vivo31P MRS provides a unique and important imaging tool for studying high-energy phosphate metabolism and bioenergetics noninvasively. However, compared to 1H MRS, 31P MRS with a relatively low gyromagnetic ratio (γ) has a lower and limited sensitivity even at ultrahigh field. The proof of concept has been recently demonstrated that the use of high dielectric constant (HDC) materials between RF coil and object sample could increase MRI signal and reduce required RF transmission power for reaching the same RF pulse flip angle in the region of interest. For low-γ MRS applications operated at relatively lower frequency, however, it demands the dielectric materials with a much higher permittivity for achieving optimal performance. We conducted a 31P MRS imaging study using ultra-HDC (uHDC; with a relative permittivity of ~1200) material blocks incorporated with an RF volume coil at ultrahigh field of 7.0T. The experimental results from phantom and human calf muscle demonstrate that the uHDC technique significantly enhanced RF magnetic transmit field (B1+) and reception field (B1-) and the gain could reach up to two folds in the tissue near the uHDC blocks. The overall results indicate that the incorporation of the uHDC materials having an appropriate permittivity value with a RF coil can significantly increase detection sensitivity and reduces RF transmission power for X-nuclei MRS applications at ultrahigh field. The uHDC technology could provide an efficient, cost-effective engineering solution for achieving high detection sensitivity and concurrently minimizing tissue heating concern for human MRS and MRI applications.
Asunto(s)
Imagen por Resonancia Magnética , Músculo Esquelético/diagnóstico por imagen , Ondas de Radio , Diseño de Equipo , Análisis de Fourier , Humanos , Espectroscopía de Resonancia Magnética , Magnetismo , Modelos Estadísticos , Fantasmas de Imagen , Relación Señal-RuidoRESUMEN
Ultrasensitive magnetoelectric (ME) sensors have been developed using magnetostrictive/piezoelectric laminate heterostructures. This paper discusses a highly interdisciplinary design of a room temperature biomagnetic liver susceptometry system (BLS) based on the ME sensors. The ME-sensor based BLS maintains the ultrahigh sensitivity to detect the weak AC biomagnetic signals and introduces a low equivalent magnetic noise. The results reveal a "turning point" and successfully indicate the output signals to be linearly responsive to iron concentrations from normal iron level (0.05 mgFe/gliver phantom) to 5 mgFe/gliver phantom iron overload level (100X overdose). Further, the introduction of the water-bag technique shows the promise on the automatic deduction of the background (tissue) signal, enabling an even higher sensitivity and better signal-to-noise (SNR). With these improvements, it becomes feasible to get improved characterization flexibility and the field distribution mapping potential via signal processing from the correlations of multiple sensors in the system. Considering the wide presence of biomagnetic signals in human organs, the potential impact of such biomagnetic devices on medicine and health care could be enormous and far-reaching.
RESUMEN
Iron is a trace mineral that plays a vital role in the human body. However, absorbing and accumulating excessive iron in body organs (iron overload) can damage or even destroy an organ. Even after many decades of research, progress on the development of noninvasive and low-cost tissue iron detection methods is very limited. Here we report a recent advance in a room-temperature ultrasensitive biomagnetic susceptometer for quantitative tissue iron detection. The biomagnetic susceptometer exploits recent advances in the magnetoelectric (ME) composite sensors that exhibit an ultrahigh AC magnetic sensitivity under the presence of a strong DC magnetic field. The first order gradiometer based on piezoelectric and magnetostrictive laminate (ME composite) structure shows an equivalent magnetic noise of 0.99 nT/rt Hz at 1 Hz in the presence of a DC magnetic field of 0.1 Tesla and a great common mode noise rejection ability. A prototype magnetoelectric liver susceptometry has been demonstrated with liver phantoms. The results indicate its output signals to be linearly responsive to iron concentrations from normal iron dose (0.05 mg Fe/g liver phantom) to 5 mg Fe/g liver phantom iron overload (100X overdose). The results here open up many innovative possibilities for compact-size, portable, cost-affordable, and room-temperature operated medical systems for quantitative determinations of tissue iron.