Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
J Prev Med Hyg ; 57(2): E110-4, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27582628

RESUMEN

Healthcare workers who use or may be exposed to needles are at risk of needlestick injuries, which can lead to serious infections by bloodborne pathogens. These injuries can be avoided by eliminating the unnecessary use of needles and using safety devices. The present study was aimed at evaluating the impact of a safety-engineered device, with passive fully automatic needlestick protection, on the rate of needlestick injuries among healthcare workers. The setting of the study was a network of five public healthcare institutions situated in a Northern Italian Region. Data on the type of device, the number of employees and the number of catheter devices used per year were collected through regular meetings with healthcare workers over a period of five years. The most notable result of this study was the huge risk reduction associated with safety devices. Indeed, the risk of needlestick injuries due to conventional devices was found to be 25-fold higher than that observed for safety devices. However, it is noteworthy that a considerable part of this excess can be explained by the different background number of devices used. Moreover, descriptive analysis suggested that individuals with a poor/moderate training level had a lower risk than those with good/high training, though the difference was not statistically significant. In conclusion, there is convincing evidence of a causal connection between the introduction of safety devices and the reduction in needlestick injuries. This consideration should prompt the introduction of safety devices into daily clinical practice.


Asunto(s)
Personal de Salud , Lesiones por Pinchazo de Aguja/prevención & control , Equipos de Seguridad , Humanos , Italia
2.
Pacing Clin Electrophysiol ; 17(11 Pt 2): 1854-8, 1994 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-7845780

RESUMEN

The purpose of this study was to assess the long-term results of a single lead VDD pacing system (Phymos MPS) in 85 patients (48 males, 37 females, mean age 74 +/- 9 years). The system, which incorporates two atrial floating electrodes (Phymos 830-S), was implanted for second- or third-degree Mobitz II AV block. The percentage of AV synchronized pacing, the presence of fusion beats due to short AV delay, and the occurrence of supraventricular arrhythmias was evaluated by Holter monitoring at 6-month intervals. Over a mean period of follow-up of 44 months (range 2-56), over 90% of AV synchronized pacing events were noted in 74 patients (87%). The presence of persistent fusion beats was detected in 12 patients (14%). In ten patients the pacemaker was reprogrammed to VVI mode for supraventricular arrhythmias (7 patients, 8.2%) or unsatisfactory atrial sensing (3 patients, 3.5%). One pacemaker was removed for pocket infection and two for battery depletion. These observations support the use of VDD single lead pacing to combine a physiological mode of stimulation with simple implantation techniques.


Asunto(s)
Estimulación Cardíaca Artificial , Anciano , Electrocardiografía , Femenino , Estudios de Seguimiento , Bloqueo Cardíaco/fisiopatología , Bloqueo Cardíaco/terapia , Humanos , Masculino , Marcapaso Artificial/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA