Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Heart Vessels ; 33(8): 908-917, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-29387924

RESUMEN

A narrow and calcified sinotubular junction (STJ) represents a risk for ascending aortic dissection after balloon-expandable transcatheter aortic valve implantation (TAVI). The aim of this study was to assess computed tomography (CT)-based aortic root morphology in patients with aortic stenosis (AS), and to evaluate the feasibility of a two-step inflation technique that we devised for TAVI using the SAPIEN 3 in patients with a narrow and calcified STJ. We retrospectively analyzed the STJ diameter (STJD) as well the as aortic annulus diameter (AAD) and STJ calcification using CT imaging in 412 patients undergoing TAVI. We defined a "narrow STJ" as a minimum STJD that was smaller than the diameter corresponding to a 10% oversized annulus area, and a "calcified STJ" as an STJ calcification angle > 90°. A "narrow and calcified STJ" was identified in 54 patients (13.1%) of patients. Among them, we performed TAVI using the two-step inflation technique with SAPIEN 3 in 20 patients and compared with 11 patients that underwent the conventional inflation procedure. Two-step inflation was successfully performed without ascending aortic dissection in all 20 patients. The effective orifice area index at discharge in these 20 patients was similar to that in 11 patients who underwent the conventional inflation procedure for a "narrow and calcified STJ" [1.40 (1.20-1.51) vs. 1.33 (1.18-1.41) cm2/m2, p = 0.23]. Although further assessment is required, the two-step inflation technique with the SAPIEN 3 is feasible for a narrow and calcified STJ.


Asunto(s)
Aorta Torácica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/diagnóstico , Ecocardiografía/métodos , Tomografía Computarizada Multidetector/métodos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/cirugía , Aortografía , Estudios de Factibilidad , Femenino , Humanos , Masculino , Diseño de Prótesis , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
2.
Vaccines (Basel) ; 12(6)2024 Jun 09.
Artículo en Inglés | MEDLINE | ID: mdl-38932374

RESUMEN

BACKGROUND: Community infections of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) have increased rapidly since the emergence of the Omicron strain. During the eighth and ninth pandemic waves-when movement restrictions in the community were eased-the all-case registration system was changed, and the actual status of infection became uncertain. METHODS: We conducted regular rapid antigen tests (R-RATs) once or twice a week as self-testing to examine the actual state of coronavirus disease (COVID-19) diagnosis among healthcare employees. RESULTS: Overall, 320 (1.42/day) and 299 (1.76/day) employees were infected in the eighth and ninth pandemic waves. During both periods, 59/263 doctors (22.4%), 335/806 nurses (41.6%), 92/194 administrative employees (47.4%), and 129/218 clinical laboratory technicians (59.2%) were infected. In the eighth wave, 56 of 195 employees were infected through close contact; in the ninth wave, 26 of 62 employees were infected. No significant difference was observed in the number of vaccinations between infected and non-infected employees. The positivity rate of R-RATs was 0.41% and 0.45% in the eighth and ninth waves. R-RATs detected infection in 212 and 229 employees during the eighth and ninth waves, respectively; the ratio of R-RAT-detected positive employees to those who reported infection was significantly higher during the ninth wave (odds ratio: 1.67, 95% confidence interval: 1.17-2.37, p < 0.001). CONCLUSIONS: The number of infected healthcare employees remained high during the eighth and ninth pandemic waves in Japan. The R-RAT is considered effective for detecting mild or asymptomatic COVID-19 at an early stage and at a high rate in healthcare employees.

3.
J Cardiol ; 81(1): 97-104, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36114119

RESUMEN

BACKGROUND: Coronary obstruction is a rare but catastrophic complication of transcatheter aortic valve replacement (TAVR) and occurs mostly at the left coronary artery (LCA) ostium. However, some patients do not show any clinical findings, and thus, its detection is sometimes difficult. The peak diastolic flow velocity in left main coronary artery (LM) was reportedly increased in significant stenosis lesions. We evaluated the effectiveness of measuring blood flow velocities in LM by transesophageal echocardiography (TEE) for the detection of LCA ostial obstruction during a TAVR procedure. METHODS: A total of 1105 consecutive patients who underwent TAVR in Sendai Kousei Hospital between September 2014 and December 2020 were enrolled. The LM blood flow velocity was measured at pre- and post-valve implantation. RESULTS: Among the 1105 patients, 9 had LCA ostial obstruction. The peak LM blood flow velocity at post-TAVR [0.90 (0.39-1.15) vs. 0.37 (0.28-0.50) m/s; p = 0.0046) was significantly higher in 9 patients who had LCA ostial obstruction, compared with the remaining 1096 patients who had not (controls), although no significant difference was observed before the TAVR procedures between the two groups. The post- to pre-TAVR LM flow velocity ratio [2.26 (1.31-3.42) vs. 1.06 (0.82-1.36); p = 0.0030] was also significantly higher in patients with LCA obstruction, compared to the controls. Furthermore, the post- to pre-TAVR LM blood flow velocity ratio was >2.0 in all six hemodynamically stable patients with LCA obstruction, whereas <2.0 in all three patients with LCA obstruction who showed hemodynamic collapse at post-TAVR procedure. CONCLUSION: Coronary blood flow velocity in LM significantly increased in hemodynamically stable LCA obstruction patients. The intraprocedural TEE measurement of the LM flow velocities would be potentially useful to detect asymptomatic and hemodynamically stable LCA ostial obstruction.


Asunto(s)
Estenosis de la Válvula Aórtica , Oclusión Coronaria , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Ecocardiografía Transesofágica , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Oclusión Coronaria/cirugía , Ecocardiografía , Resultado del Tratamiento , Válvula Aórtica/cirugía
4.
J Clin Ultrasound ; 40(4): 247-51, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22434728

RESUMEN

Although regular supraventricular tachycardia is traditionally classified on the basis of P-wave morphology, diagnostic accuracy is limited to information obtained from surface electrocardiography. Intracardiac electrophysiology is a conclusive although invasive diagnostic method. We report a case of regular supraventricular tachycardia with a heart rate of 162 bpm. M-mode echocardiography of the interatrial septum clarified both the atrial rate and the ventricular response ratio. Tissue Doppler M-mode imaging demonstrated the delay between the posterior wall motion of the left and right atrium. Although it deserves further study, transthoracic echocardiography may provide useful information in addition to electrocardiography.


Asunto(s)
Aleteo Atrial/diagnóstico por imagen , Ecocardiografía Doppler , Taquicardia Supraventricular/diagnóstico por imagen , Anciano , Aleteo Atrial/complicaciones , Aleteo Atrial/fisiopatología , Electrocardiografía , Atrios Cardíacos/diagnóstico por imagen , Frecuencia Cardíaca , Humanos , Masculino , Taquicardia Supraventricular/complicaciones , Taquicardia Supraventricular/fisiopatología
5.
J Cardiol ; 80(3): 190-196, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35469714

RESUMEN

BACKGROUND: In transcatheter aortic valve replacement (TAVR) using SAPIEN 3 (S3) (Edwards Lifesciences, Irvine, CA, USA), some clinicians decrease or increase the delivery balloon volume (VOL) when deploying S3 or conducting post-dilatation. However, the effects of controlling VOL on transcatheter heart valve diameter (THVD) and valve function remain unclear. We assessed associations among VOL, THVD, and effective orifice area (EOA) of S3. METHODS: We enrolled patients undergoing TAVR using 23- and 26-mm S3 in Sendai Kousei Hospital between 2017 and 2019. VOL was controlled based on preprocedural computed tomography and intraprocedural transesophageal echocardiography (TEE). THVD were defined as the diameters of transcatheter heart valve at mid-level measured by TEE. RESULTS: In enrolled 332 patients (23-mm, n = 188; 26-mm, n = 144), one (0.3%) and two (0.6%) developed annulus rupture and moderate/severe paravalvular leak, respectively. VOL at deployment was positively correlated with THVD on deployment (23-mm, r = 0.44, p < 0.001; 26-mm, r = 0.57, p < 0.001) and EOA (23-mm, r = 0.23, p = 0.0019; 26-mm, r = 0.22, p = 0.0094). In multiple regression analyses, VOL and post-dilatation were significant determinants of THVD, although aortic annulus area, calcium volume, and pre-dilatation were not. The areas under the receiver operating characteristic curve that were used to evaluate the accuracy of the index obtained by dividing THVD by body surface area (indexed THVD) to predict patient-prosthesis mismatch (PPM) were 0.744 and 0.811 in the 23- and 26-mm cohorts, respectively. A cut-off indexed THVD of ≤11.5 and 12.1 mm/m2 well predicted PPM (23-mm, odds ratio, 5.20; 95% confidence interval, 1.33-20.3; 26-mm, odds ratio 14.1, 95% confidence interval 2.40-81.0). CONCLUSION: VOL was positively correlated with THVD and EOA. Smaller indexed THVD was associated with a higher incidence of PPM. Controlling VOL under on-site THVD evaluation may be useful in reducing the PPM incidence.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
6.
Cardiovasc Interv Ther ; 34(4): 364-372, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30725361

RESUMEN

Preprocedural computed tomography (CT) imaging appears to provide an advantage in localization of the appropriate septal branch targeted for alcohol septal ablation (ASA). The objective of this study was to compare the clinical backgrounds, procedural characteristics, and outcomes of patients who underwent ASA with preprocedural CT assessment against those without CT assessment. Thirty consecutive patients with obstructive hypertrophic cardiomyopathy who underwent ASA were retrospectively included. Patients who underwent preprocedural CT (CT-guided ASA group, n = 11) were compared with patients who underwent ASA without CT (traditional ASA group, n = 19). The CT-guided ASA group had a significantly lower number of approached target vessels (1 [interquartile range {IQR}, 1-2] vs. 2 [IQR, 2-3], P = 0.036) and non-ablated target vessels (0 [IQR, 0-1] vs. 1 [IQR, 0-2], P = 0.031) than the traditional ASA group. There were no differences between the two groups in total fluoroscopy time, the amount of delivered radiation dose, and the volume of contrast medium used during the procedures. There were also no differences between the two groups in procedural success rate and improvement of left ventricular outflow tract gradient and New York Heart Association functional class at 1 month follow-up. CT had a significant impact on the ASA procedure diminishing the number of target vessels, and could be a reliable assessment modality to build its procedural strategy.


Asunto(s)
Técnicas de Ablación/métodos , Cardiomiopatía Hipertrófica/cirugía , Tabiques Cardíacos/diagnóstico por imagen , Tabiques Cardíacos/cirugía , Tomografía Computarizada Multidetector , Anciano , Cardiomiopatía Hipertrófica/diagnóstico por imagen , Angiografía por Tomografía Computarizada/métodos , Etanol , Femenino , Humanos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Radiografía Intervencional , Estudios Retrospectivos
7.
Tex Heart Inst J ; 46(1): 44-47, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30833838

RESUMEN

Ventricular septal defect (VSD) is a rare, potentially fatal complication of acute myocardial infarction. When surgical closure is contraindicated, transcatheter closure may be an alternative. Residual shunting after transcatheter closure of postinfarction VSDs has been reported; however, we found few cases of this in patients who also had severe heart failure or hemolysis. We report 2 closures of postinfarction VSDs with use of the Amplatzer Septal Occluder. Both elderly patients-one with severe heart failure, one with persistent hemolysis, and neither a surgical candidate-had high-velocity residual shunting through the occluders. We intensively managed the patients' conditions and used angiography and transthoracic echocardiography to record the gradual disappearance of each shunt over 4 months-the first such serial monitoring of which we are aware. We think that even substantial shunting in the presence of severe heart failure or hemolysis can eventually resolve spontaneously, assuming effective management of the concomitant medical conditions.


Asunto(s)
Cateterismo Cardíaco/métodos , Defectos del Tabique Interventricular/cirugía , Infarto del Miocardio/complicaciones , Dispositivo Oclusor Septal , Anciano , Ecocardiografía , Femenino , Defectos del Tabique Interventricular/etiología , Humanos , Masculino , Infarto del Miocardio/diagnóstico , Remisión Espontánea , Resultado del Tratamiento
8.
Cardiovasc Interv Ther ; 32(1): 82-86, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26711631

RESUMEN

An 82-year-old woman had a history of mitral valve replacement with a 25-mm MOSAIC (Medtronic, USA) for severe mitral regurgitation (MR) 8 years previously. Recently, she developed heart failure due to MR secondary to prosthetic valve failure. She underwent transcatheter valve-in-valve implantation with a 23-mm SAPIEN XT (Edwards Lifesciences, USA) to the prosthetic mitral valve by transapical approach. To our knowledge, this is the first reported case of transcatheter valve implantation for failed mitral prosthetic valve using valve-in-valve technique in Japan.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas/efectos adversos , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Anciano de 80 o más Años , Ecocardiografía , Femenino , Humanos , Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/diagnóstico , Diseño de Prótesis , Falla de Prótesis , Reoperación
9.
Cardiovasc Interv Ther ; 32(4): 436-439, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28108954

RESUMEN

An 85-year-old man with a high risk for open heart surgery underwent a percutaneous closure of an atrial septal defect that lacked adequate aortic and superior rims. To avoid the risk for erosion, a Figulla Flex II ASD occluder was selected for the procedure. Implantation was successful, and no complications were observed during the 6 months of follow-up.


Asunto(s)
Defectos del Tabique Interatrial/cirugía , Implantación de Prótesis/métodos , Dispositivo Oclusor Septal , Anciano de 80 o más Años , Cateterismo Cardíaco , Ecocardiografía Transesofágica , Defectos del Tabique Interatrial/diagnóstico por imagen , Defectos del Tabique Interatrial/patología , Humanos , Masculino , Diseño de Prótesis
11.
J Invasive Cardiol ; 27(11): E242-7, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26524209

RESUMEN

OBJECTIVES: We aimed to investigate the feasibility and safety of alcohol septal ablation (ASA) via transradial approach using a sheathless guiding catheter. BACKGROUND: Although ASA is conventionally performed via the femoral artery, there is a potential risk of bleeding and other vascular complications. The transradial approach may be associated with a lower rate of such complications. A sheathless guiding catheter, with an advanced hydrophilic coating along its full length, could reduce radial artery occlusion and spasm. METHODS: We enrolled 14 consecutive patients with hypertrophic obstructive cardiomyopathy treated with ASA via the radial access at Sendai Kousei Hospital from December 2012 to May 2014. Left radial access was used for the sheathless guiding catheter, while right radial access was used for monitoring left ventricular pressure with a 4 Fr diagnostic catheter. A temporary pacemaker was inserted via the right jugular vein. RESULTS: Procedural success rate was 93% (13/14 patients). The left ventricular outflow tract pressure gradient at rest was reduced from a median of 128 mm Hg (interquartile range, 49-147 mm Hg) at baseline to a median of 16 mm Hg (interquartile range, 13-26 mm Hg) at 30-day follow-up (P=.01). The New York Heart Association functional class improved from a median of II (II-III) at baseline to a median of I (I-I) at 30-day follow-up (P=.01). There were no cases of access-site complication, including radial artery occlusion and spasm. CONCLUSIONS: The transradial approach using a sheathless guiding catheter was feasible and safe for ASA.


Asunto(s)
Técnicas de Ablación/instrumentación , Cateterismo Cardíaco/instrumentación , Catéteres Cardíacos , Cardiomiopatía Hipertrófica/cirugía , Etanol/farmacología , Tabiques Cardíacos/cirugía , Anciano , Diseño de Equipo , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Arteria Radial , Resultado del Tratamiento
12.
Cardiovasc Interv Ther ; 28(2): 216-21, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23224935

RESUMEN

A 77-year-old woman underwent percutaneous closure of post-infarction ventricular septal defect. The defect was successfully closed with a 20-mm Amplatzer septal occluder with a small residual shunt and Qp/Qs improved from 3.38 to 1.48. She was discharged 30 days after procedure. To our knowledge, this is the first case reported in Japan.


Asunto(s)
Defectos del Tabique Interventricular/terapia , Infarto del Miocardio/complicaciones , Intervención Coronaria Percutánea/instrumentación , Dispositivo Oclusor Septal , Anciano , Angiografía Coronaria , Ecocardiografía , Femenino , Defectos del Tabique Interventricular/diagnóstico , Defectos del Tabique Interventricular/etiología , Humanos , Japón , Tomografía Computarizada por Rayos X
13.
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA