Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Rev Med Inst Mex Seguro Soc ; 56(2): 158-162, 2018.
Artículo en Español | MEDLINE | ID: mdl-29901975

RESUMEN

Background: Tuberculosis (TB) is still a threat to public health; in 2014 caused 1.5 million deaths worldwide; in hospitals where the prevalence of TB is low, it is appropriate to evaluate the effectiveness of tests to diagnose it. Methods: We reviewed reports of airway clinical specimens sent for studies of tuberculosis to the microbiology laboratory from Tec Salud System private hospitals (400 beds) in the metropolitan area of ​​Monterrey, NL, from May 2012 to December 2015. In conjunction with Ziehl-Neelsen (ZN) stain, and solid Lowenstein-Jensen medium (LJ), our laboratory resources also include fluorescent LED microscopy (Carl Zeiss Microscopy Products), MGIT 320 (Mycobacteria Growth Indicator Tube liquid culture detection system, Becton Dickinson), and recently incorporated a real-time PCR system the Xpert MTB/RIF test (Cepheid, Sunnyvale, CA). Results: In 731 respiratory specimens from 510 patients, M. tuberculosis was isolated from 78 samples belonging to 50 patients on LJ and MGIT LJ 42 (84%) and MGIT 49, (98%) of the samples. From 41 patients identified, 26 (63.4%) were positive to fluorescein, and 25 (60.9%) with Ziehl-Neelsen stain. Real time PCR (Xpert TB) was positive in 13 out of 17 patient-airway samples (76.4%). Conclusions: Usefulness of liquid culture (MGIT) and solid culture (LJ) is shown; the first can significantly cut incubation times.


Introducción: la tuberculosis (TB) aún es una amenaza para la salud pública; en 2014 causó 1.5 millones de muertes a nivel mundial. En hospitales donde la prevalencia de TB es baja, resulta conveniente evaluar la efectividad de las pruebas para diagnosticarla. Métodos: revisamos los informes de resultados de muestras de vías respiratorias enviadas para estudios de tuberculosis de mayo de 2012 a diciembre de 2015 al laboratorio de Microbiología del Sistema Tec Salud (400 camas) en el área metropolitana de Monterrey. Además de la tinción de Ziehl-Neelsen (ZN) y cultivo sólido de Lowenstein-Jensen (LJ); se realizó fluorescencia LED, cultivo en medio líquido MGIT 320 y más recientemente el Xpert MTB/RIF test. Resultados: se cultivaron en LJ y MGIT 731 muestras de vías respiratorias de 510 pacientes; en las muestras de 50 de ellos se identificó M. tuberculosis, 49 en MGIT (98%) y 42 en LJ (84%). De las muestras correspondientes a 41 pacientes, 26 (63.4%) fueron positivas con fluoresceína, y 25 (60.9%) con ZN. En las muestras de 17 pacientes se hizo PCR en tiempo real (Xpert MTB), 13 fueron positivas (76.4%). Conclusiones: se demuestra la utilidad del cultivo en medio liquido (MGIT) y del LJ en medio sólido; el primero, además de ser más sensible, permite acortar en forma importante los tiempos de incubación.


Asunto(s)
Técnicas Bacteriológicas/métodos , Tuberculosis/diagnóstico , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Hospitales Privados , Humanos , Incidencia , Masculino , México/epidemiología , Persona de Mediana Edad , Sensibilidad y Especificidad , Tuberculosis/epidemiología , Adulto Joven
2.
Rev Med Inst Mex Seguro Soc ; 54(3): 292-6, 2016.
Artículo en Español | MEDLINE | ID: mdl-27100973

RESUMEN

BACKGROUND: Harboring a high mortality, the incidence of sepsis is increasing; thus detection, identification and susceptibility tests of the involved microorganisms become urgent. METHODS: We reviewed the records from January 2013 until July 2014 of a total of 4110 blood culture bottles taken from adult patients in a private tertiary hospital. RESULTS: Growth of microorganisms was observed in 559 bottles (12.6%). We emphasize that 2648 blood cultures (60%) were taken in two paired aerobic and anaerobic bottles drawn at the same time (1324 pairs); from these, growth was observed in 182 inoculated bottles drawn from two different sites at the same time from 135 patients (13.7%). In 86 pairs of bottles with samples from 54 patients (40%), growth occurred only in the aerobic blood culture bottles. Also, growth of microorganisms was observed only in anaerobic bottles in 24 pairs (13.19%), corresponding to 21 patients (15.5%, p<0.05%). In blood cultures from 32 out of 60 patients with growth in both media (53%), microbial growth was detected first in the anaerobic bottle. CONCLUSIONS: The usefulness of blood cultures for anaerobes for the identification of obligate anaerobic bacteremia which rarely occur is low (2.2% of patients with bacteremia); however, in 15.55% of the patients the risk of completely overlook bacteremia was present, and in 53% of patients with positive cultures, bacteremia was established earlier, and thus permitted earlier and accurate decision making.


Introducción: la frecuencia de la septicemia va en aumento y su mortalidad es alta; por lo tanto, su detección, la identificación del microorganismo causal y su susceptibilidad son perentorias. Metodos: se revisaron los registros de 4110 botellas de cultivo de sangre obtenida de enero de 2013 a julio de 2014 de pacientes adultos en un hospital privado de tercer nivel. Resultados: se observó crecimiento de microorganismos en 559 cultivos (12.6 %). En 2648 hemocultivos (60 %) inoculados en pares de frascos uno con medio aeróbico y el otro anaeróbico (1324 sets), se detectó crecimiento en 182 frascos a los que les fueron inoculadas las muestras tomadas al mismo tiempo a 135 pacientes (13.7 %). En 86 pares de frascos con las muestras de 54 pacientes (40 %), el crecimiento solamente se dio en el frasco aeróbico (47.5 %); en 24 pares de frascos (13.19 %) tomados a 21 pacientes (15.5 %, p < 0.05), solamente hubo crecimiento en el frasco anaeróbico. En los hemocultivos de 32 de 60 pacientes con crecimiento en ambos frascos (53 %), el crecimiento se detectó primero en el frasco anaeróbico. Conclusiones: los hemocultivos anaeróbicos tienen una utilidad baja para la detección de bacteriemias por anaerobios estrictos; no obstante, en el 15.55 % de los pacientes estuvo presente el riesgo de pasar por alto la presencia de bacteriemia, y en 53 % de los pacientes con hemocultivos positivos, el diagnóstico de bacteriemia pudo establecerse de manera más temprana, lo que permitió anticipar con mejor precisión la toma de decisiones.


Asunto(s)
Bacteriemia/diagnóstico , Bacterias Anaerobias/aislamiento & purificación , Cultivo de Sangre/métodos , Adulto , Bacteriemia/microbiología , Humanos , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA