1.
N Engl J Med ; 388(23): 2121-2131, 2023 Jun 08.
Artículo en Inglés | MEDLINE | ID: mdl-37285526

RESUMEN

BACKGROUND: Data showing the efficacy and safety of the transplantation of hearts obtained from donors after circulatory death as compared with hearts obtained from donors after brain death are limited. METHODS: We conducted a randomized, noninferiority trial in which adult candidates for heart transplantation were assigned in a 3:1 ratio to receive a heart after the circulatory death of the donor or a heart from a donor after brain death if that heart was available first (circulatory-death group) or to receive only a heart that had been preserved with the use of traditional cold storage after the brain death of the donor (brain-death group). The primary end point was the risk-adjusted survival at 6 months in the as-treated circulatory-death group as compared with the brain-death group. The primary safety end point was serious adverse events associated with the heart graft at 30 days after transplantation. RESULTS: A total of 180 patients underwent transplantation; 90 (assigned to the circulatory-death group) received a heart donated after circulatory death and 90 (regardless of group assignment) received a heart donated after brain death. A total of 166 transplant recipients were included in the as-treated primary analysis (80 who received a heart from a circulatory-death donor and 86 who received a heart from a brain-death donor). The risk-adjusted 6-month survival in the as-treated population was 94% (95% confidence interval [CI], 88 to 99) among recipients of a heart from a circulatory-death donor, as compared with 90% (95% CI, 84 to 97) among recipients of a heart from a brain-death donor (least-squares mean difference, -3 percentage points; 90% CI, -10 to 3; P<0.001 for noninferiority [margin, 20 percentage points]). There were no substantial between-group differences in the mean per-patient number of serious adverse events associated with the heart graft at 30 days after transplantation. CONCLUSIONS: In this trial, risk-adjusted survival at 6 months after transplantation with a donor heart that had been reanimated and assessed with the use of extracorporeal nonischemic perfusion after circulatory death was not inferior to that after standard-care transplantation with a donor heart that had been preserved with the use of cold storage after brain death. (Funded by TransMedics; ClinicalTrials.gov number, NCT03831048.).


Asunto(s)
Muerte Encefálica , Trasplante de Corazón , Obtención de Tejidos y Órganos , Adulto , Humanos , Supervivencia de Injerto , Preservación de Órganos , Donantes de Tejidos , Muerte , Seguridad del Paciente
2.
Artículo en Inglés | MEDLINE | ID: mdl-38981770

RESUMEN

Heart transplantation is the definitive treatment for refractory, end-stage heart failure. The number of patients awaiting transplantation far exceeds available organs. In an effort to expand the donor pool, donation after circulatory death (DCD) heart transplantation has garnered renewed interest. Unlike donation after brain death, DCD donors do not meet the criteria for brain death and are dependent on life-sustaining therapies. Procurement can include a direct strategy or a normothermic regional perfusion, whereby there is restoration of perfusion to the organ before explantation. There are new developments in cold storage and ex vivo perfusion strategies. Since its inception, there has been a steady improvement in post-transplant outcomes, largely attributed to advancements in operative and procurement strategies. In this narrative review, the authors address the unique considerations of DCD heart transplantation, including withdrawal of care, the logistics of procuring and resuscitating organs, outcomes compared with standard donation after brain death, and ethical considerations.

3.
N Engl J Med ; 380(17): 1618-1627, 2019 04 25.
Artículo en Inglés | MEDLINE | ID: mdl-30883052

RESUMEN

BACKGROUND: In two interim analyses of this trial, patients with advanced heart failure who were treated with a fully magnetically levitated centrifugal-flow left ventricular assist device were less likely to have pump thrombosis or nondisabling stroke than were patients treated with a mechanical-bearing axial-flow left ventricular assist device. METHODS: We randomly assigned patients with advanced heart failure to receive either the centrifugal-flow pump or the axial-flow pump irrespective of the intended goal of use (bridge to transplantation or destination therapy). The composite primary end point was survival at 2 years free of disabling stroke or reoperation to replace or remove a malfunctioning device. The principal secondary end point was pump replacement at 2 years. RESULTS: This final analysis included 1028 enrolled patients: 516 in the centrifugal-flow pump group and 512 in the axial-flow pump group. In the analysis of the primary end point, 397 patients (76.9%) in the centrifugal-flow pump group, as compared with 332 (64.8%) in the axial-flow pump group, remained alive and free of disabling stroke or reoperation to replace or remove a malfunctioning device at 2 years (relative risk, 0.84; 95% confidence interval [CI], 0.78 to 0.91; P<0.001 for superiority). Pump replacement was less common in the centrifugal-flow pump group than in the axial-flow pump group (12 patients [2.3%] vs. 57 patients [11.3%]; relative risk, 0.21; 95% CI, 0.11 to 0.38; P<0.001). The numbers of events per patient-year for stroke of any severity, major bleeding, and gastrointestinal hemorrhage were lower in the centrifugal-flow pump group than in the axial-flow pump group. CONCLUSIONS: Among patients with advanced heart failure, a fully magnetically levitated centrifugal-flow left ventricular assist device was associated with less frequent need for pump replacement than an axial-flow device and was superior with respect to survival free of disabling stroke or reoperation to replace or remove a malfunctioning device. (Funded by Abbott; MOMENTUM 3 ClinicalTrials.gov number, NCT02224755.).


Asunto(s)
Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Diseño de Prótesis , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Supervivencia sin Enfermedad , Femenino , Corazón Auxiliar/efectos adversos , Humanos , Análisis de Intención de Tratar , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Falla de Prótesis , Reoperación/estadística & datos numéricos , Accidente Cerebrovascular/etiología
4.
JAMA ; 328(12): 1233-1242, 2022 09 27.
Artículo en Inglés | MEDLINE | ID: mdl-36074476

RESUMEN

Importance: Although durable left ventricular assist device (LVAD) therapy has emerged as an important treatment option for patients with advanced heart failure refractory to pharmacological support, outcomes, including survival, beyond 2 years remain poorly characterized. Objective: To report the composite end point of survival to transplant, recovery, or LVAD support free of debilitating stroke (Modified Rankin Scale score >3) or reoperation to replace the pump 5 years after the implant in participants who received the fully magnetically levitated centrifugal-flow HeartMate 3 or axial-flow HeartMate II LVAD in the MOMENTUM 3 randomized trial and were still receiving LVAD therapy at the 2-year follow-up. Design, Setting, and Participants: This observational study was a 5-year follow-up of the MOMENTUM 3 trial, conducted in 69 US centers, that demonstrated superiority of the centrifugal-flow LVAD to the axial-flow pump with respect to survival to transplant, recovery, or LVAD support free of debilitating stroke or reoperation to replace the pump at 2 years. A total of 295 patients were enrolled between June 2019 to April 2021 in the extended-phase study, with 5-year follow-up completed in September 2021. Exposures: Of 1020 patients in the investigational device exemption per-protocol population, 536 were still receiving LVAD support at 2 years, of whom 289 received the centrifugal-flow pump and 247 received the axial-flow pump. Main Outcomes and Measures: There were 10 end points evaluated at 5 years in the per-protocol population, including a composite of survival to transplant, recovery, or LVAD support free of debilitating stroke or reoperation to replace the pump between the centrifugal-flow and axial-flow pump groups and overall survival between the 2 groups. Results: A total of 477 patients (295 enrolled and 182 provided limited data) of 536 patients still receiving LVAD support at 2 years contributed to the extended-phase analysis (median age, 62 y; 86 [18%] women). The 5-year Kaplan-Meier estimate of survival to transplant, recovery, or LVAD support free of debilitating stroke or reoperation to replace the pump in the centrifugal-flow vs axial-flow group was 54.0% vs 29.7% (hazard ratio, 0.55 [95% CI, 0.45-0.67]; P < .001). Overall Kaplan-Meier survival was 58.4% in the centrifugal-flow group vs 43.7% in the axial-flow group (hazard ratio, 0.72 [95% CI, 0.58-0.89]; P = .003). Serious adverse events of stroke, bleeding, and pump thrombosis were less frequent in the centrifugal-flow pump group. Conclusions and Relevance: In this observational follow-up study of patients from the MOMENTUM 3 randomized trial, per-protocol analyses found that receipt of a fully magnetically levitated centrifugal-flow LVAD vs axial-flow LVAD was associated with a better composite outcome and higher likelihood of overall survival at 5 years. These findings support the use of the fully magnetically levitated LVAD. Trial Registration: ClinicalTrials.gov Identifier: NCT02224755 and NCT03982979.


Asunto(s)
Insuficiencia Cardíaca/cirugía , Corazón Auxiliar , Femenino , Estudios de Seguimiento , Corazón Auxiliar/efectos adversos , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Accidente Cerebrovascular/etiología , Resultado del Tratamiento
5.
J Card Fail ; 23(12): 852-858, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28757150

RESUMEN

BACKGROUND: Device indications have changed for placement of continuous-flow left ventricular assist devices (CF-LVADs). We performed a multicenter analysis evaluating temporal variations in outcomes after CF-LVAD implantation. METHODS & RESULTS: We retrospectively defined 3 time intervals to reflect changes in CF-LVAD technology (period 1, 2004-2009; period 2, 2010-2012; and period 3, 2012-2014). A total of 1,064 patients (Heartmate II [HMII] = 835; Heartware [HVAD] = 229) underwent CF-LVAD implantation from May 2004 to October 2014. Device utilization was different between periods: period 1: HMII = 134 (100%); period 2: HMII = 480 (88%) and HW = 63 (12%); and period 3: HMII = 221 (57%) and HW = 166 (43%); P < .001. Despite few baseline group differences, adjusted survivals were similar among the time periods (P = .96). Adjusted multivariable analysis revealed age (per 10-year increase) and Interagency Registry for Mechanically Assisted Circulatory Support category (1 vs all others) as the only independent predictors of mortality: P < .001 and P = .008, respectively. Furthermore, it also showed the later periods to be at an increased risk of adverse events: 1) pump thrombosis (periods 2 and 3); and 2) gastrointestinal bleeding (period 3). CONCLUSIONS: Despite significant differences in device types, indications, and patient characteristics, post-implantation survivals were similar across time intervals. The most recent cohort seems to be at an increased risk of gastrointestinal bleeding and pump thrombosis.


Asunto(s)
Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/cirugía , Corazón Auxiliar/tendencias , Adulto , Anciano , Estudios de Cohortes , Circulación Extracorporea/tendencias , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Tasa de Supervivencia/tendencias , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
6.
J Card Fail ; 22(12): 981-987, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27765670

RESUMEN

BACKGROUND: Limited data exist on outcomes in patients ≥70 years of age supported with the use of continuous-flow left ventricular assist devices (LVADs). METHODS: Data on 1149 continuous-flow LVAD recipients was queried from the Mechanical Circulatory Support Research Network. Groups were assigned based on age: ≥70 years ("older patients") and <70 years. The primary outcome was survival at one-year based on age grouping. RESULTS: Compared with younger patients (54.3 ± 11.2 y; n = 986), older patients (73.4 ± 3.0 y) constituted only 14% of LVAD implants. Older patients had similar rates of device thrombosis (P = .47) and stroke (P = .44), but survival-free of gastrointestinal bleeding (GIB) at 1 year was lower compared with younger patients (58% vs 69%; P < .01). Unadjusted survival at 1 year in older patients was 75% compared with 84% in younger patients, and at 2 years 65% versus 73% (P = .18). Age ≥70 years was not associated with increased mortality (adjusted hazard ratio [aHR] 0.94, 95% confidence interval [CI] 0.70-1.26; P = .67). Preoperative creatinine (aHR 1.57, 95% CI: 1.30-1.89, P < .0001), bilirubin (aHR 1.22, 95% CI 1.05-1.42; P = .010), and ischemic cardiomyopathy (aHR 1.43, 95% CI 1.11-1.84; P = .005) portended increased risk of death. In older patients, the only predictor of mortality was creatinine (HR 2.1, 95% CI 1.2-3.4; P = .007). Creatinine ≥1.4 mg/dL was associated with a 1-year survival of 65%, compared with 84% when the creatinine was <1.4 mg/dL (P = .009). CONCLUSION: Age >70 years is an important consideration when assessing LVAD risk, but other correlates may be more predictive of LVAD survival. Older patients without renal dysfunction have survival similar to younger patients. Older patients should be counseled about age-correlated risks, including higher rates of GIB.


Asunto(s)
Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Adulto , Factores de Edad , Anciano , Femenino , Insuficiencia Cardíaca/fisiopatología , Hospitalización , Humanos , Masculino , Persona de Mediana Edad , Selección de Paciente , Estudios Retrospectivos , Tasa de Supervivencia , Resultado del Tratamiento
7.
J Card Surg ; 30(10): 775-80, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26283153

RESUMEN

BACKGROUND: Recent reports suggested that HeartMate II (HMII) thrombosis rates may be higher in implants after 2011. We characterize events at HMII centers (>100 HMII implants) whose device thrombosis rates are equivalent or lower than reported by INTERMACS. METHODS: Seven centers pooled implants from 2011 through June 2013 to examine pump thrombus and identify characteristics and clinical strategies that potentially mitigate the risk. A total of 666 patients (age 59 ± 13 years; 81% male) were studied (support duration: 13.7 ± 8.3 months, cumulative: 759 patient years). Median target INR was 2.25 (range 2.0 to 2.5), and median pump speed was 9200 rpm (range 8600 to 9600). Pump thrombus was suspected with clinical evidence (e.g., hemolysis, positive ramp test) requiring intervention (e.g., anticoagulation therapy, pump exchange) or patient death. RESULTS: Suspected pump thrombus occurred in 24/666 (3.6%) patients within three months of implant. At six months, 38/666 (5.7%) had suspected pump thrombus including 24 (3.6%) resulting in pump exchange or death. Stroke (hemorrhagic: 0.049, and ischemic: 0.048 events/patient year) and survival (six months: 88 ± 1%; 1 year: 81 ± 2%) were consistent with national averages. Suspected pump thrombus patients were younger (55 ± 13 vs. 59 ± 13, p = 0.046) and had more females (31.6% vs. 18.3%, p = 0.054). There was no difference in indication, etiology of heart failure, or body size. CONCLUSIONS: This analysis demonstrates low HMII thrombus events. Minimization of risk factors by uniform implant techniques and consistent post-op management may reduce device thrombosis. A larger scale multicenter evaluation may better elucidate the difference in thrombus events between centers.


Asunto(s)
Ventrículos Cardíacos , Corazón Auxiliar/efectos adversos , Trombosis/epidemiología , Trombosis/etiología , Adulto , Factores de Edad , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Implantación de Prótesis/métodos , Factores de Riesgo , Factores Sexuales , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Trombosis/prevención & control , Factores de Tiempo
8.
J Heart Valve Dis ; 23(3): 338-42, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-25296459

RESUMEN

BACKGROUND AND AIM OF THE STUDY: The authors' institution participated in a 28-center FDA Investigational Device Exemption study to evaluate the Sorin Mitroflow pericardial aortic bioprosthesis. Six high-enrolling sites evaluated patients on an annual basis as part of an ongoing hemodynamic study. These data represent patients followed for an average of five years after implant, with annual echocardiography. METHODS: Seventy-one patients were entered into the study and constitute the basis of this review. Mean follow up was 3.3 +/- 2.0 years (range: 0-5.5 years), with a cumulative follow up of 233 patient-years. The mean patient age was 73.8 years (range: 45-89 years), and 52% were males. The majority of aortic valve lesions were stenosis (63%) or mixed (30%), and nine patients (12.7%) were reoperations. Sixty-one patients (86%) had concomitant procedures, the most common being coronary artery bypass grafting (70%). RESULTS: A total of 281 echocardiograms was obtained from the patients over a five-year period. The largest number of echocardiograms was obtained with 23-mm valve implants (n = 122), followed by 25 mm valve implants (n = 87). The early baseline (30-day) mean gradient was < or = 10 mm in all patients. The mean gradient decreased as the valve size increased (21 mm valve gradient = 10.0 +/- 5.6 mmHg; 27 mm valve gradient = 6.2 +/- 2.2 mmHg). The mean increase in gradient at five years was < 7 mmHg, with a trend towards increased gradients at smaller valve sizes. The effective orifice area (EOA) showed a trend to decline slightly with 21 mm valves (from 1.5 to 1.2 cm2) and 23 mm valves (1.4 to 1.2 cm2), but there was either no change or a slight increase in larger-size valves. Left ventricular mass regression occurred mainly within the first year (18.9%), but then remained stable throughout the study period. No greater than mild prosthetic aortic valve regurgitation was observed over the study period. CONCLUSION: The Sorin Mitroflow aortic valve provides excellent hemodynamic results up to five years, with minimal increase in mean gradients, acceptable peak gradients, and good EOAs with all valves sizes.


Asunto(s)
Válvula Aórtica/fisiopatología , Válvula Aórtica/cirugía , Bioprótesis , Cardiopatías Congénitas/fisiopatología , Cardiopatías Congénitas/cirugía , Enfermedades de las Válvulas Cardíacas/fisiopatología , Enfermedades de las Válvulas Cardíacas/cirugía , Prótesis Valvulares Cardíacas , Hemodinámica , Adulto , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Enfermedad de la Válvula Aórtica Bicúspide , Aprobación de Recursos , Femenino , Estudios de Seguimiento , Cardiopatías Congénitas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Implantación de Prótesis de Válvulas Cardíacas , Humanos , Masculino , Persona de Mediana Edad , Pericardio , Complicaciones Posoperatorias , Ultrasonografía , Estados Unidos , United States Food and Drug Administration
9.
Artículo en Inglés | MEDLINE | ID: mdl-38367698

RESUMEN

OBJECTIVES: The HeartMate 3 (Abbott) left ventricular assist device provides substantial improvement in long-term morbidity and mortality in patients with advanced heart failure. The Implantation of the HeartMate 3 in Subjects With Heart Failure Using Surgical Techniques Other Than Full Median Sternotomy study compares thoracotomy-based implantation clinical outcomes with standard median sternotomy. METHODS: We conducted a prospective, multicenter, single-arm study in patients eligible for HeartMate 3 implantation with thoracotomy-based surgical technique (bilateral thoracotomy or partial upper sternotomy with left thoracotomy). The composite primary end point was survival free of disabling stroke (modified Rankin score >3), or reoperation to remove or replace a malfunctioning device, or conversion to median sternotomy at 6-months postimplant (elective transplants were treated as a success). The primary end point (noninferiority, -15% margin) was assessed with >90% power compared with a propensity score-matched cohort (ratio 1:2) derived from the Multi-Center Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy With HeartMate 3 continued access protocol. RESULTS: The study enrolled 102 patients between December 2020 and July 2022 in the thoracotomy-based arm at 23 North American centers. Follow-up concluded in December 2022. In the Implantation of the HeartMate 3 in Subjects With Heart Failure Using Surgical Techniques Other Than Full Median Sternotomy study group, noninferiority criteria was met (absolute between-group difference, -1.2%; Farrington Manning lower 1-sided 95% CI, -9.3%; P < .0025) and event-free survival was not different (85.0% vs 86.2%; hazard ratio, 1.01; 95% CI, 0.58-2.10). Length of stay with thoracotomy-based implant was longer (median, 20 vs 17 days; P = .03). No differences were observed for blood product utilization, adverse events (including right heart failure), functional status, and quality of life between cohorts. CONCLUSIONS: Thoracotomy-based implantation of the HeartMate 3 left ventricular assist device is noninferior to implantation via standard full sternotomy. This study supports thoracotomy-based implantation as an additional standard for surgical implantation of the HeartMate 3 left ventricular assist device.

10.
JACC Heart Fail ; 12(3): 438-447, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38276933

RESUMEN

BACKGROUND: Extended criteria donor (ECD) hearts available with donation after brain death (DBD) are underutilized for transplantation due to limitations of cold storage. OBJECTIVES: This study evaluated use of an extracorporeal perfusion system on donor heart utilization and post-transplant outcomes in ECD DBD hearts. METHODS: In this prospective, single-arm, multicenter study, adult heart transplant recipients received ECD hearts using an extracorporeal perfusion system if hearts met study criteria. The primary outcome was a composite of 30-day survival and absence of severe primary graft dysfunction (PGD). Secondary outcomes were donor heart utilization rate, 30-day survival, and incidence of severe PGD. The safety outcome was the mean number of heart graft-related serious adverse events within 30 days. Additional outcomes included survival through 2 years benchmarked to concurrent nonrandomized control subjects. RESULTS: A total of 173 ECD DBD hearts were perfused; 150 (87%) were successfully transplanted; 23 (13%) did not meet study transplantation criteria. At 30 days, 92% of patients had survived and had no severe PGD. The 30-day survival was 97%, and the incidence of severe PGD was 6.7%. The mean number of heart graft-related serious adverse events within 30 days was 0.17 (95% CI: 0.11-0.23). Patient survival was 93%, 89%, and 86% at 6, 12, and 24 months, respectively, and was comparable with concurrent nonrandomized control subjects. CONCLUSIONS: Use of an extracorporeal perfusion system resulted in successfully transplanting 87% of donor hearts with excellent patient survival to 2 years post-transplant and low rates of severe PGD. The ability to safely use ECD DBD hearts could substantially increase the number of heart transplants and expand access to patients in need. (International EXPAND Heart Pivotal Trial [EXPANDHeart]; NCT02323321; Heart EXPAND Continued Access Protocol; NCT03835754).


Asunto(s)
Insuficiencia Cardíaca , Trasplante de Corazón , Adulto , Humanos , Supervivencia de Injerto , Insuficiencia Cardíaca/cirugía , Trasplante de Corazón/métodos , Preservación de Órganos/métodos , Estudios Prospectivos , Estudios Retrospectivos , Donantes de Tejidos
11.
J Heart Lung Transplant ; 42(11): 1510-1514, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37499959

RESUMEN

In June 2021, HVAD System distribution ceased due to observational data demonstrating increased mortality and neurological events compared to another commercial device, and a device malfunction with delay or failure to restart, especially in certain subpopulations. To assess ongoing risk for patients on support following subsequent device recalls, the manufacturer's Intermacs HVAD System 2022 Quarterly Reports were queried to identify mortality and adverse events trends in a contemporary cohort of 3110 primary HVAD implantations since October 2017, stratified by year-of-implant. Mean duration of support was 21 ± 16 months, with 33% alive on original device, 25% transplanted, 6% undergoing device exchange, 4% recovered, and 32% expired. Kaplan-Meier and event-per-patient-year estimates for survival, freedom from device explant, stroke, and pump thrombus were similar across year-of-implant. Following market withdrawal and recent device recalls, there appears to be no increase in mortality, stroke, pump thrombus, or explant for HVAD-supported patients. Quarterly report monitoring is ongoing.

12.
J Am Coll Cardiol ; 82(9): 771-781, 2023 08 29.
Artículo en Inglés | MEDLINE | ID: mdl-37612008

RESUMEN

BACKGROUND: In advanced heart failure patients implanted with a fully magnetically levitated HeartMate 3 (HM3, Abbott) left ventricular assist device (LVAD), it is unknown how preimplant factors and postimplant index hospitalization events influence 5-year mortality in those able to be discharged. OBJECTIVES: The goal was to identify risk predictors of mortality through 5 years among HM3 LVAD recipients conditional on discharge from index hospitalization in the MOMENTUM 3 pivotal trial. METHODS: This analysis evaluated 485 of 515 (94%) patients discharged after implantation of the HM3 LVAD. Preimplant (baseline), implant surgery, and index hospitalization characteristics were analyzed individually, and as multivariable predictors for mortality risk through 5 years. RESULTS: Cumulative 5-year mortality in the cohort (median age: 62 years, 80% male, 65% White, 61% destination therapy due to transplant ineligibility) was 38%. Two preimplant characteristics (elevated blood urea nitrogen and prior coronary artery bypass graft or valve procedure) and 3 postimplant characteristics (hemocompatibility-related adverse events, ventricular arrhythmias, and estimated glomerular filtration rate <60 mL/min/1.73 m2 at discharge) were predictors of 5-year mortality. In 171 of 485 patients (35.3%) without any risk predictors, 5-year mortality was reduced to 22.6% (95% CI: 15.4%-32.7%). Even among those with 1 or more predictors, mortality was <50% at 5 years (45.7% [95% CI: 39.0%-52.8%]). CONCLUSIONS: Long-term survival in successfully discharged HM3 LVAD recipients is largely influenced by clinical events experienced during the index surgical hospitalization in tandem with baseline factors, with mortality of <50% at 5 years. In patients without identified predictors of risk, long-term 5-year mortality is low and rivals that achieved with heart transplantation, even though most were implanted with destination therapy intent. (MOMENTUM 3 IDE Clinical Study Protocol, NCT02224755; MOMENTUM 3 Pivotal Cohort Extended Follow-up PAS, NCT03982979).


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Femenino , Humanos , Masculino , Persona de Mediana Edad , Puente de Arteria Coronaria , Insuficiencia Cardíaca/terapia , Hospitalización , Alta del Paciente
13.
Ann Thorac Surg ; 114(6): 2262-2269, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35452663

RESUMEN

BACKGROUND: Outcomes in patients with smaller body size after HeartMate 3 left ventricular assist device (HM3) implantation are not well characterized. We sought to evaluate outcomes in smaller vs larger body surface area (BSA) patients in the MOMENTUM 3 pivotal trial and its Continued Access Protocol cohort. METHODS: The analysis cohort included 1015 HM3 patients divided into 2 groups: BSA ≤1.70 m2 (small patients, n = 82) and BSA >1.70 m2 (large patients, n = 933). The composite primary end point was survival at 2 years free of disabling stroke or reoperation to replace or to remove a malfunctioning device. Adverse events were compared between groups. RESULTS: Smaller patients were more frequently women (56.1% vs 17.7%; P < .001) and had lower prevalence of diabetes (28.1% vs 43.9%; P = .005) and hypertension (51.2% vs 71.9%; P < .001), larger median indexed LVEDD (normalized by BSA, 40 vs 33 mm/m2; P < .001), and lower median serum creatinine concentration (1.1 vs 1.3 mg/dL; P < .001). The proportion of patients achieving the composite end point at 2 years was 77% in both groups (adjusted hazard ratio, 1.14; 95% CI, 0.68-1.91; P = .62). Two-year adverse event rates were also similar between groups except for sepsis (6.1% vs 14.9%; P = .029) and cardiac arrhythmias (24.4% vs 35.3%; P = .005), which were higher in the larger patients. CONCLUSIONS: Outcomes after HM3 implantation were comparable between small and large patients. Smaller body size should not be used to deny HM3 implantation in patients who are otherwise suitable candidates for durable mechanical circulatory support.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Adulto , Femenino , Humanos , Tamaño Corporal , Insuficiencia Cardíaca/etiología , Corazón Auxiliar/efectos adversos , Estudios Prospectivos , Estudios Retrospectivos , Resultado del Tratamiento
14.
J Thorac Cardiovasc Surg ; 163(6): 2107-2116.e6, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-34112505

RESUMEN

OBJECTIVE: To determine characteristics, outcomes, and clinical factors associated with death in patients with COVID-19 requiring extracorporeal membrane oxygenation (ECMO) support. METHODS: A multicenter, retrospective cohort study was conducted. The cohort consisted of adult patients (18 years of age and older) requiring ECMO in the period from March 1, 2020, to September 30, 2020. The primary outcome was in-hospital mortality after ECMO initiation assessed with a time to event analysis at 90 days. Multivariable Cox proportional regression was used to determine factors associated with in-hospital mortality. RESULTS: Overall, 292 patients from 17 centers comprised the study cohort. Patients were 49 (interquartile range, 39-57) years old and 81 (28%) were female. At the end of the follow-up period, 19 (6%) patients were still receiving ECMO, 25 (9%) were discontinued from ECMO but remained hospitalized, 135 (46%) were discharged or transferred alive, and 113 (39%) died during the hospitalization. The cumulative in-hospital mortality at 90 days was 42% (95% confidence interval [CI], 36%-47%). Factors associated with in-hospital mortality were age (adjusted hazard ratio [aHR], 1.31; 95% CI, 1.06-1.61 per 10 years), renal dysfunction measured according to serum creatinine level (aHR, 1.21; 95% CI, 1.01-1.45), and cardiopulmonary resuscitation before ECMO placement (aHR, 1.87; 95% CI, 1.01-3.46). CONCLUSIONS: In patients with severe COVID-19 necessitating ECMO support, in-hospital mortality occurred in fewer than half of the cases. ECMO might serve as a viable modality for terminally ill patients with refractory COVID-19.


Asunto(s)
COVID-19 , Oxigenación por Membrana Extracorpórea , Síndrome de Dificultad Respiratoria , Adolescente , Adulto , COVID-19/terapia , Niño , Oxigenación por Membrana Extracorpórea/efectos adversos , Femenino , Mortalidad Hospitalaria , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
15.
Eur J Cardiothorac Surg ; 62(1)2022 06 15.
Artículo en Inglés | MEDLINE | ID: mdl-35325091

RESUMEN

The HeartWare HVAD System (Medtronic) is a durable implantable left ventricular assist device that has been implanted in approximately 20,000 patients worldwide for bridge to transplant and destination therapy indications. In December 2020, Medtronic issued an Urgent Medical Device Communication informing clinicians of a critical device malfunction in which the HVAD may experience a delay or failure to restart after elective or accidental discontinuation of pump operation. Moreover, evolving retrospective comparative effectiveness studies of patients supported with the HVAD demonstrated a significantly higher risk of stroke and all-cause mortality when compared with a newer generation of a commercially available durable left ventricular assist device. Considering the totality of this new information on HVAD performance and the availability of an alternate commercially available device, Medtronic halted the sale and distribution of the HVAD System in June 2021. The decision to remove the HVAD from commercial distribution now requires the use of the HeartMate 3 left ventricular assist system (Abbott, Inc) if a patient previously implanted with an HVAD requires a pump exchange. The goal of this document is to review important differences in the design of the HVAD and HeartMate 3 that are relevant to the medical management of patients supported with these devices, and to assess the technical aspects of an HVAD-to-HeartMate 3 exchange. This document provides the best available evidence that supports best practices. (J Thorac Cardiovasc Surg 2022;-:1-8).


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Accidente Cerebrovascular , Insuficiencia Cardíaca/cirugía , Corazón Auxiliar/efectos adversos , Humanos , Estudios Retrospectivos , Accidente Cerebrovascular/etiología
16.
J Thorac Cardiovasc Surg ; 163(6): 2120-2127.e5, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35341579

RESUMEN

The HeartWare HVAD System (Medtronic) is a durable implantable left ventricular assist device that has been implanted in approximately 20,000 patients worldwide for bridge to transplant and destination therapy indications. In December 2020, Medtronic issued an Urgent Medical Device Communication informing clinicians of a critical device malfunction in which the HVAD may experience a delay or failure to restart after elective or accidental discontinuation of pump operation. Moreover, evolving retrospective comparative effectiveness studies of patients supported with the HVAD demonstrated a significantly higher risk of stroke and all-cause mortality when compared with a newer generation of a commercially available durable left ventricular assist device. Considering the totality of this new information on HVAD performance and the availability of an alternate commercially available device, Medtronic halted the sale and distribution of the HVAD System in June 2021. The decision to remove the HVAD from commercial distribution now requires the use of the HeartMate 3 left ventricular assist system (Abbott, Inc) if a patient previously implanted with an HVAD requires a pump exchange. The goal of this document is to review important differences in the design of the HVAD and HeartMate 3 that are relevant to the medical management of patients supported with these devices, and to assess the technical aspects of an HVAD-to-HeartMate 3 exchange. This document provides the best available evidence that supports best practices.


Asunto(s)
Corazón Auxiliar , Diseño de Equipo , Insuficiencia Cardíaca/cirugía , Corazón Auxiliar/efectos adversos , Humanos , Estudios Retrospectivos , Accidente Cerebrovascular/epidemiología
17.
Ann Thorac Surg ; 113(6): 1770-1777, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35341592

RESUMEN

The HeartWare HVAD System (Medtronic) is a durable implantable left ventricular assist device that has been implanted in approximately 20,000 patients worldwide for bridge to transplant and destination therapy indications. In December 2020, Medtronic issued an Urgent Medical Device Communication informing clinicians of a critical device malfunction in which the HVAD may experience a delay or failure to restart after elective or accidental discontinuation of pump operation. Moreover, evolving retrospective comparative effectiveness studies of patients supported with the HVAD demonstrated a significantly higher risk of stroke and all-cause mortality when compared with a newer generation of a commercially available durable left ventricular assist device. Considering the totality of this new information on HVAD performance and the availability of an alternate commercially available device, Medtronic halted the sale and distribution of the HVAD System in June 2021. The decision to remove the HVAD from commercial distribution now requires the use of the HeartMate 3 left ventricular assist system (Abbott, Inc) if a patient previously implanted with an HVAD requires a pump exchange. The goal of this document is to review important differences in the design of the HVAD and HeartMate 3 that are relevant to the medical management of patients supported with these devices, and to assess the technical aspects of an HVAD-to-HeartMate 3 exchange. This document provides the best available evidence that supports best practices.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Accidente Cerebrovascular , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/cirugía , Corazón Auxiliar/efectos adversos , Humanos , Estudios Retrospectivos , Accidente Cerebrovascular/etiología
18.
Eur J Heart Fail ; 23(8): 1392-1400, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33932272

RESUMEN

AIM: The MOMENTUM 3 pivotal trial established superiority of the HeartMate 3 (HM3) left ventricular assist device (LVAD), a fully magnetically levitated centrifugal-flow pump, over the HeartMate II axial-flow pump. We now evaluate HM3 LVAD outcomes in a single-arm prospective continuous access protocol (CAP) post-pivotal trial study. METHODS AND RESULTS: We enrolled 2200 HM3 implanted patients (515 pivotal trial and 1685 CAP patients) and compared outcomes including survival free of disabling stroke or reoperation to replace or remove a malfunctioning device (primary composite endpoint), overall survival and major adverse events at 2 years. The 2-year primary endpoint [76.7% vs. 74.8%; adjusted hazard ratio (HR) 0.87, 95% confidence interval (CI) 0.71-1.08, P = 0.21] and overall survival (81.2% vs. 79.0%) were similar among CAP and pivotal cohorts despite sicker patients (more intra-aortic balloon pump use and INTERMACS profile 1) in CAP who were more often intended for destination therapy. Survival was similar between the CAP and pivotal trial in transplant ineligible patients (79.1% vs. 76.7%; adjusted HR 0.89, 95% CI 0.68-1.16, P = 0.38). In a pooled analysis, the 2-year primary endpoint was similar between INTERMACS profiles 1-2 ('unstable' advanced heart failure), profile 3 ('stable' on inotropic therapy), and profiles 4-7 ('stable' ambulatory advanced heart failure) (75.7% vs. 77.6% vs. 72.9%, respectively). The net burden of adverse events was lower in CAP (adjusted rate ratio 0.93, 95% CI 0.88-0.98, P = 0.006), with consequent decrease in hospitalization. CONCLUSIONS: The primary results of accumulating HM3 LVAD experience suggest a lower adverse event burden and similar survival compared to the pivotal MOMENTUM 3 trial.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Accidente Cerebrovascular , Insuficiencia Cardíaca/terapia , Humanos , Estudios Prospectivos , Resultado del Tratamiento
19.
JACC Case Rep ; 2(9): 1365-1367, 2020 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-32835281

RESUMEN

Shared decision making with patients in advanced heart failure is critical when making decisions on therapies such as left ventricular assist device implantation and cardiac transplantation. We describe a case wherein the risks of coronavirus disease-2019 affected the decision of a patient regarding proceeding with cardiac transplantation. (Level of Difficulty: Beginner.).

20.
JACC Case Rep ; 2(14): 2235-2239, 2020 Nov 18.
Artículo en Inglés | MEDLINE | ID: mdl-34317147

RESUMEN

A 55-year-old patient was found to have complete heart block during preoperative assessment. Cardiac magnetic resonance imaging revealed an interatrial mass suggestive of primary cardiac tumor. Extensive evaluation including intracardiac biopsy and finally open resection revealed lipomatous hypertrophy masquerading as tumor. (Level of Difficulty: Intermediate.).