RESUMEN
PURPOSE: The effects of the 5-hydroxytryptamine (5-HT3) receptor antagonists on regional anaesthesia are complex and unclear. The present study was designed to test the hypothesis that granisetron, a selective 5-HT3 receptor antagonist, would decrease the duration of motor block, sensory block, and proprioception in a dose-dependent fashion in a rat model of bupivacaine-induced sciatic nerve blockade. MATERIALS AND METHODS: Thirty-eight male Wistar Albino rats that received unilateral sciatic nerve blocks were randomly divided into five experimental groups. Group B received a perineural of 0.3 ml of bupivacaine alone; Group BG800 received perineural 0.3 ml of bupivacaine and 800 µg of granisetron 10 min later; Group BG1200 received perineural 0.3 ml of bupivacaine and 1200 µg of granisetron 10 min later; Group BG1200IP received a perineural 0.3 ml of bupivacaine and an intraperitoneal injection of 1200 µg of granisetron 10 min later; and Group S was sham operated. A blinded investigator assessed motor, sensory and proprioception function every 10 min until the return of normal function. RESULTS: The medians for recovery times in Group B, Group BG800, Group BG1200, and Group BG1200IP were 105, 64, 85, and 120 min for motor function, respectively; 80, 64, 84, and 104 min for sensory function; 80, 63, 85, and 108 min were calculated for the proprioception function. The time to the return of normal motor, sensory, and proprioception function was not statistically significantly different between the groups (p > 0.05). Motor block did not develop in any of the rats in Group S. CONCLUSIONS: Local and systemic application of granisetron was not significantly decrease the duration of bupivacaine induced motor, sensory, and proprioception block of sciatic nerve in rat.
Asunto(s)
Anestesia de Conducción , Bloqueo Nervioso , Ratas , Masculino , Animales , Bupivacaína/farmacología , Anestésicos Locales/farmacología , Granisetrón/farmacología , Ratas Wistar , Nervio CiáticoRESUMEN
BACKGROUND AND AIM: Trendelenburg positioning (TP) is a common approach used during internal jugular vein (IJV) cannulation. No evidence indicates that TP significantly increases the cross-sectional area (CSA) of the IJV or decreases the overlap between the carotid artery (CA) and the IJV in dialysis patients. The primary aim of this study was to investigate the effects of the TP on the CSA of the right IJV and on its relationship to the CA. METHODS: Thirty-seven consecutive hemodialysis patients older than 18 years of age were enrolled. We measured the CSA of the right IJV and overlap rate (at end-expiration at the level of the cricoid cartilage) between the CA and the IJV in two positions: State 0, table flat (no tilt), with the patient in the supine position; State T, in which the operating table was tilted to 15° of TP. RESULTS: Data were collected for all of the 37 patients enrolled in the study. The change in CSA and overlap between the CA and the IJV from the supine to the TP was not significantly different. The CSA was paradoxically decreased in 11 of 37 patients when changed from State 0 to State T. CONCLUSIONS: TP does not significantly increase the CSA of the right IJV or decrease the overlap between the CA and the IJV in dialysis patients. In fact, in some patients, it reduces the CSA. Therefore, the use of the TP for IJV cannulation in dialysis patients can no longer be supported.
Asunto(s)
Cateterismo Venoso Central/efectos adversos , Inclinación de Cabeza/fisiología , Venas Yugulares/diagnóstico por imagen , Diálisis Renal/efectos adversos , Anciano , Arterias Carótidas/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , UltrasonografíaRESUMEN
OBJECTIVE: Trendelenburg positioning is a common approach used during internal jugular vein (IJV) cannulation. No evidence indicates that Trendelenburg positioning significantly increases the cross-sectional area (CSA) of the IJV in obese patients. The primary aim of this study was to determine the effectiveness of Trendelenburg positioning on the CSA of the right internal jugular vein assessed with ultrasound measurement in obese patients. METHODS: Forty American Society of Anesthesiologists II patients with body mass index ≥30 kg/m(2) undergoing various elective surgeries under general endotracheal anesthesia were enrolled. Ultrasound images of the right IJV were obtained in a transverse orientation at the cricoid level. We measured the CSA of the right IJV two different conditions in a sealed envelope were applied in random order: State 0, table flat (no tilt), with the patients in the supine position, and State T, in which the operating table was tilted 20° to the Trendelenburg position. RESULTS: The change in the CSA of the IJV from the supine to the Trendelenburg position (1.80 cm(2) vs 2.08cm(2)) was not significantly different. The CSA was paradoxically decreased in 10 of 36 patients when the position changed from State 0 to State T. CONCLUSIONS: Trendelenburg positioning does not significantly increase the mean CSA of the right IJV in obese patients. In fact, in some patients, this position decreases the CSA. The use of the Trendelenburg position for IJV cannulation in obese patients can no longer be supported.
RESUMEN
Ultrasound-guided right internal jugular vein catheterization (RIJV) should be the first choice to decrease the catheter-related complications in high-risk hemodialysis patients. For this procedure, clinicians should identify the optimum positions of the RIJV, including its lower overlap with the carotid artery (CA) and high cross-sectional area of the vein. The aim of this prospective randomized study to evaluate the effects of mild ipsilateral head rotation combined with Trendelenburg position on RIJV cross-sectional area and its relation to the CA in adult patients. Forty ASA I-II patients who were undergoing elective surgery were enrolled for this study. The subjects were asked to remain supine in the 15-20° Trendelenburg position. Two-dimensional ultrasound was then used to measure the degree of overlap between the RIJV and CA, the cross-sectional area of the RIJV. These measurements were compared between head rotation to the >30° left, <30° left, neutral, and <30° right positions. When the head was in the >30° left position, overlap was seen in 38 of 40 patients (95%). As the head was rotated from >30° left to <30° right, the CA-RIJV overlap (from 95% to 57.5%), and the cross-sectional area (from 14.2 mm to 8.7 mm) significantly decreased. In conclusion, when the head was turned to <30° right, the CA-RIJV overlap significantly decreased, and the cross-sectional area also decreased. When clinicians determine the optimal head position before RIJV cannulation, it is important to consider the advantages and disadvantages of the different head positions from >30° left to <30° right.
Asunto(s)
Cateterismo Venoso Central/métodos , Venas Yugulares/cirugía , Adulto , Arterias Carótidas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Adulto JovenRESUMEN
BACKGROUND: The Iowa Satisfaction with Anesthesia Scale (ISAS) is a valid and reliable measurement tool developed to evaluate patient satisfaction with anesthesia care during different surgical interventions. It is adapted to various languages and used in many studies. Considering the satisfaction of the patient with anesthesia applied in surgical procedures, the presence of such a measurement tool is crucial. AIM: From this point of view, the study aimed to evaluate psychometric properties of the ISAS by adapting it to Turkish culture. METHODS: In this study, a descriptive, methodological and cross-sectional design was used. A total of 210 patients who underwent surgery under general or regional anesthesia were in the study. RESULTS: ISAS Turkish version (ISAS-T) shows good reliability which is obvious with a Cronbach's alpha value of 0.80. The correlation levels of the items with the ISAS total score were calculated between .45 and .73. Test-retest reliability was calculated as 0.83. CFA analysis was applied to the one-dimensional 11-item final version of ISAS. The uni-dimensionality of the 11-item scale was confirmed on a Turkish patient sample. The fit indices for the model obtained were calculated as χ2/sd = 2.342, RMSEA = .80, SRMR = .04, CFI = .90, GFI = .92. The fit indices of the model have good and acceptable fit values. CONCLUSION: Based on the psychometric evaluation, ISAS-T is a valid and reliable measurement tool for measuring patient satisfaction with anesthesia applied during different surgical procedures.
Asunto(s)
Anestesia , Humanos , Psicometría , Reproducibilidad de los Resultados , Estudios Transversales , Encuestas y CuestionariosRESUMEN
OBJECTIVE: Central venous access remains a cornerstone procedure for a variety of clinical conditions. Ultrasound studies suggest that rotation of the head increases the magnitude of the overlap of the internal jugular vein with the carotid artery. The authors assessed whether a neutral position of the head during anatomic landmark-guided cannulation of the internal jugular vein (IJV) was an attractive alternative to rotating the neck to a >45° head turn. DESIGN: A prospective, randomized, controlled study. SETTING: An education and research hospital and a university-affiliated hospital. PARTICIPANTS: Eighty patients requiring central venous catheterization in the right IJV. INTERVENTIONS: Under general anesthesia, patients were positioned in the Trendelenburg position with extension of the neck. In the rotated group, the head was rotated to the left at >45°. In the neutral group, the head was placed in the neutral position. Right IJV cannulation was performed using the central approach with the needle angled toward the ipsilateral nipple. The primary outcome variable was the cumulative success rate, which was defined as IJV puncture achieved in the first 3 attempts using a finder needle. A p value of <0.05 was considered statistically significant. MEASUREMENTS AND MAIN RESULTS: Groups were similar in terms of demographic data. The success rates of finder needle passes into the IJV on the first attempt were 87.5% and 37.5% (p < 0.05), and the cumulative success rates on the first 3 attempts were 97.5% and 57.5% in the rotated and neutral groups, respectively (p < 0.05). Carotid artery puncture only occurred in 2 patients in the rotated group. CONCLUSIONS: Because of the lower success rate, the neutral head position is not an attractive alternative for IJV catheterization when compared with the rotated head position in a central landmark IJV approach.
Asunto(s)
Cateterismo Venoso Central/métodos , Cabeza , Venas Yugulares/cirugía , Postura , Rotación , Adulto , Anciano , Cateterismo Venoso Central/instrumentación , Femenino , Cabeza/irrigación sanguínea , Cabeza/fisiología , Humanos , Venas Yugulares/fisiología , Masculino , Persona de Mediana Edad , Postura/fisiología , Estudios ProspectivosRESUMEN
This study was aimed to investigate the effects of different fresh gas (oxygen + air) flow rates and different anesthetics on airway temperature and humidity when using the same anesthesia machine in patients undergoing general anesthesia. In this prospective, observational study, 240 patients with American Society of Anesthesiologists (ASA) I-II between the age of 18-65 years to be operated under general anesthesia were enrolled and divided into two groups according to the fresh gas flow rate (3-6 L/min). Each of the two main groups was further divided into three subgroups according to the administered anesthetic gases and drugs. The resulting six groups were further divided into two subgroups according to whether the heat and humidity exchanger filter (HME) was attached to the breathing circuit, and the study was carried out on a total of 12 groups. The temperature and humidity of the inspired air were recorded every 10 minutes using an electronic thermo-hygrometer. The inspired temperature and humidity were greater in patients ventilated at 3 L/min compared to the 6 L/min group and in HME (+) patients compared to HME (-), regardless of the type of anesthetics. HME application makes the air more physiological for the respiratory tract by increasing the temperature and humidity of the air regardless of the anesthetic agent. This study was approved by Ethics Committee Review of Selcuk University Faculty of Medicine (No. 2017/261) in September 2017, and was registered in the Clinical Trial Registry (identifier No. NCT04204746) on December 19, 2019.
Asunto(s)
Anestésicos por Inhalación , Adolescente , Adulto , Anciano , Anestesia General , Humanos , Humedad , Persona de Mediana Edad , Estudios Prospectivos , Temperatura , Adulto JovenRESUMEN
BACKGROUND: Several devices and algorithms have already been examined and compared for difficult airway management. However, there is no existing study comparing the success of the Intubating Catheter (IC) and the Videolaryngoscope (VL) in patients who are difficult to intubate. We aimed to compare Frova IC and McGrath VL in terms of intubation success rates in patients with difficult intubation. METHODS: This prospective, randomized study was performed in an university hospital. Patients who underwent an operation under general anesthesia and whom airway management process was deemed difficult were included in this study. Patients were randomly divided into two groups by envelopes containing a number: the intubating catheter group (Group IC), intubated using the Frova IC, and the videolaryngoscope group (Group VL), intubated using the McGrath VL. Study data were collected by a technician who was blind to the study groups and the type of device used in the intubation procedure. RESULTS: A total of 49 patients with difficult airway were included in the study, including 25 patients in the Frova IC Group and 24 patients in the McGrath VL Group. The rate of successful intubation was determined to be 88% in Group IC and 66% in Group VL (p = 0.074). The mean duration of intubation attempt in Group VL was 44.62 seconds, whereas in Group IC, it was 51.12 seconds (p = 0.593). Group VL was found to have a significantly lower Cormack-Lehane grade compared to Group IC (p < 0.001). CONCLUSION: Frova IC is a candidate to be an indispensable instrument in terms of cost-effectiveness in clinics such as anesthesia and emergency medicine, where difficult intubation cases are frequently encountered. However, the combination of Frova IC and McGrath VL seems to be more successful in difficult intubation situations, so future studies should focus on using these two devices together.
Asunto(s)
Laringoscopios , Laringoscopía , Anestesia General , Catéteres , Humanos , Intubación Intratraqueal/métodos , Estudios Prospectivos , Grabación en VideoRESUMEN
STUDY OBJECTIVE: Complex regional pain syndrome is a painful and disabling syndrome where the patient presents with neuropathic pain, edema, or vasomotor or pseudomotor abnormalities that are often refractory to treatment. Complex regional pain syndrome type 1 may occurs in stroke patients. Radiofrequency is a therapeutic modality that has been used for years for diseases associated with neuropathic pain. DESIGN: Case series report. SETTING: Selcuk University Hospital. PATIENTS: A 69-year-old woman and a 48-year-old women who suffered post-stroke complex regional pain syndrome type 1. INTERVENTIONS: Pulsed radiofrequency current application to the cervical dorsal root ganglia. MEASUREMENTS: Pain reduction. MAIN RESULTS: The patients had complete resolution of their symptoms, which was maintained at 10 and 5 months of follow-up. CONCLUSIONS: These cases illustrates that pulsed radiofrequency applied to cervical dorsal root ganglia might play a significant role in multi-modal approach of complex regional pain syndrome type 1 management after stroke. Further randomized, controlled studies are needed to support this argument.