Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Crit Care Sci ; 36: e20240005en, 2024.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-38985048

RESUMEN

OBJECTIVE: To investigate the factors influencing carbon dioxide transfer in a system that integrates an oxygenation membrane in series with high-bicarbonate continuous veno-venous hemodialysis in hypercapnic animals. METHODS: In an experimental setting, we induced severe acute kidney injury and hypercapnia in five female Landrace pigs. Subsequently, we initiated high (40mEq/L) bicarbonate continuous veno-venous hemodialysis with an oxygenation membrane in series to maintain a pH above 7.25. At intervals of 1 hour, 6 hours, and 12 hours following the initiation of continuous veno-venous hemodialysis, we performed standardized sweep gas flow titration to quantify carbon dioxide transfer. We evaluated factors associated with carbon dioxide transfer through the membrane lung with a mixed linear model. RESULTS: A total of 20 sweep gas flow titration procedures were conducted, yielding 84 measurements of carbon dioxide transfer. Multivariate analysis revealed associations among the following (coefficients ± standard errors): core temperature (+7.8 ± 1.6 °C, p < 0.001), premembrane partial pressure of carbon dioxide (+0.2 ± 0.1/mmHg, p < 0.001), hemoglobin level (+3.5 ± 0.6/g/dL, p < 0.001), sweep gas flow (+6.2 ± 0.2/L/minute, p < 0.001), and arterial oxygen saturation (-0.5 ± 0.2%, p = 0.019). Among these variables, and within the physiological ranges evaluated, sweep gas flow was the primary modifiable factor influencing the efficacy of low-blood-flow carbon dioxide removal. CONCLUSION: Sweep gas flow is the main carbon dioxide removal-related variable during continuous veno-venous hemodialysis with a high bicarbonate level coupled with an oxygenator. Other carbon dioxide transfer modulating variables included the hemoglobin level, arterial oxygen saturation, partial pressure of carbon dioxide and core temperature. These results should be interpreted as exploratory to inform other well-designed experimental or clinical studies.


Asunto(s)
Lesión Renal Aguda , Bicarbonatos , Dióxido de Carbono , Terapia de Reemplazo Renal Continuo , Modelos Animales de Enfermedad , Hipercapnia , Animales , Dióxido de Carbono/sangre , Femenino , Lesión Renal Aguda/terapia , Lesión Renal Aguda/metabolismo , Porcinos , Bicarbonatos/sangre , Terapia de Reemplazo Renal Continuo/métodos , Hipercapnia/terapia , Hipercapnia/sangre , Hipercapnia/metabolismo , Hipoventilación/terapia , Hipoventilación/etiología , Hipoventilación/sangre , Oxigenación por Membrana Extracorpórea/métodos , Oxigenación por Membrana Extracorpórea/efectos adversos
2.
Rev Bras Ter Intensiva ; 34(4): 402-409, 2022.
Artículo en Portugués, Inglés | MEDLINE | ID: mdl-36888819

RESUMEN

OBJECTIVE: To characterize the pressures, resistances, oxygenation, and decarboxylation efficacy of two oxygenators associated in series or in parallel during venous-venous extracorporeal membrane oxygenation support. METHODS: Using the results of a swine severe respiratory failure associated with multiple organ dysfunction venous-venous extracorporeal membrane oxygenation support model and mathematical modeling, we explored the effects on oxygenation, decarboxylation and circuit pressures of in-parallel and in-series associations of oxygenators. RESULTS: Five animals with a median weight of 80kg were tested. Both configurations increased the oxygen partial pressure after the oxygenators. The return cannula oxygen content was also slightly higher, but the impact on systemic oxygenation was minimal using oxygenators with a high rated flow (~ 7L/minute). Both configurations significantly reduced the systemic carbon dioxide partial pressure. As the extracorporeal membrane oxygenation blood flow increased, the oxygenator resistance decreased initially with a further increase with higher blood flows but with a small clinical impact. CONCLUSION: Association of oxygenators in parallel or in series during venous-venous extracorporeal membrane oxygenation support provides a modest increase in carbon dioxide partial pressure removal with a slight improvement in oxygenation. The effect of oxygenator associations on extracorporeal circuit pressures is minimal.


OBJETIVO: Caracterizar as pressões, as resistências, a oxigenação e a eficácia da descarboxilação de dois oxigenadores associados em série ou em paralelo durante o suporte com oxigenação veno-venosa por membrana extracorpórea. MÉTODOS: Usando os resultados de insuficiência respiratória grave em suínos associada à disfunção de múltiplos órgãos, ao modelo de suporte com oxigenação por membrana extracorpórea veno-venosa e à modelagem matemática, exploramos os efeitos na oxigenação, descarboxilação e pressões do circuito de associações de oxigenadores em paralelo e em série. RESULTADOS: Testaram-se cinco animais com peso mediano de 80kg. Ambas as configurações aumentaram a pressão parcial de oxigênio após os oxigenadores. O teor de oxigênio da cânula de retorno também foi ligeiramente maior, mas o efeito na oxigenação sistêmica foi mínimo, usando oxigenadores com alto fluxo nominal (~ 7L/minuto). Ambas as configurações reduziram significativamente a pressão parcial de dióxido de carbono sistêmico. Como o fluxo sanguíneo na oxigenação por membrana extracorpórea aumentou, a resistência do oxigenador diminuiu inicialmente, com aumento posterior, com fluxos sanguíneos mais altos, mas pouco efeito clínico. CONCLUSÃO: A associação de oxigenadores em paralelo ou em série durante o suporte com oxigenação veno-venosa por membrana extracorpórea proporciona um modesto aumento na depuração da pressão parcial de dióxido de carbono, com leve melhora na oxigenação. O efeito das associações de oxigenadores nas pressões de circuitos extracorpóreos é mínimo.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Humanos , Animales , Porcinos , Oxigenación por Membrana Extracorpórea/métodos , Oxígeno , Dióxido de Carbono , Oxigenadores , Pulmón
3.
Rev Bras Ter Intensiva ; 32(1): 37-42, 2020 Mar.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-32401969

RESUMEN

OBJECTIVE: To evaluate adherence to the stress ulcer prophylaxis protocol in critically ill patients at a tertiary university hospital. METHODS: In this prospective cohort study, we included all adult patients admitted to the medical and surgical intensive care units of an academic tertiary hospital. Our sole exclusion criterion was upper gastrointestinal bleeding at intensive care unit admission. We collected baseline variables and stress ulcer prophylaxis indications according to the institutional protocol and use of prophylaxis. Our primary outcome was adherence to the stress ulcer prophylaxis protocol. Secondary outcomes were appropriate use of stress ulcer prophylaxis, upper gastrointestinal bleeding incidence and factors associated with appropriate use of stress ulcer prophylaxis. RESULTS: Two hundred thirty-four patients were enrolled from July 2nd through July 31st, 2018. Patients were 52 ± 20 years old, 125 (53%) were surgical patients, and the mean SAPS 3 was 52 ± 20. In the longitudinal follow-up, 1499 patient-days were studied; 1069 patient-days had stress ulcer prophylaxis indications, and 777 patient-days contained prophylaxis use (73% stress ulcer prophylaxis protocol adherence). Of the 430 patient-days without stress ulcer prophylaxis indications, 242 involved prophylaxis (56% inappropriate stress ulcer prophylaxis use). The overall appropriate use of stress ulcer prophylaxis was 64%. Factors associated with proper stress ulcer prophylaxis prescription were mechanical ventilation OR 2.13 (95%CI 1.64 - 2.75) and coagulopathy OR 2.77 (95%CI 1.66 - 4.60). The upper gastrointestinal bleeding incidence was 12.8%. CONCLUSION: Adherence to the stress ulcer prophylaxis protocol was low and inappropriate use of stress ulcer prophylaxis was frequent in this cohort of critically ill patients.


Asunto(s)
Adhesión a Directriz/estadística & datos numéricos , Úlcera Péptica/prevención & control , Adulto , Anciano , Estudios de Cohortes , Enfermedad Crítica , Femenino , Hemorragia Gastrointestinal/epidemiología , Hemorragia Gastrointestinal/etiología , Humanos , Masculino , Persona de Mediana Edad , Úlcera Péptica/complicaciones , Estudios Prospectivos
5.
Rev. bras. ter. intensiva ; 34(4): 402-409, out.-dez. 2022. tab, graf
Artículo en Portugués | LILACS-Express | LILACS | ID: biblio-1423677

RESUMEN

RESUMO Objetivo: Caracterizar as pressões, as resistências, a oxigenação e a eficácia da descarboxilação de dois oxigenadores associados em série ou em paralelo durante o suporte com oxigenação veno-venosa por membrana extracorpórea. Métodos: Usando os resultados de insuficiência respiratória grave em suínos associada à disfunção de múltiplos órgãos, ao modelo de suporte com oxigenação por membrana extracorpórea veno-venosa e à modelagem matemática, exploramos os efeitos na oxigenação, descarboxilação e pressões do circuito de associações de oxigenadores em paralelo e em série. Resultados: Testaram-se cinco animais com peso mediano de 80kg. Ambas as configurações aumentaram a pressão parcial de oxigênio após os oxigenadores. O teor de oxigênio da cânula de retorno também foi ligeiramente maior, mas o efeito na oxigenação sistêmica foi mínimo, usando oxigenadores com alto fluxo nominal (~ 7L/minuto). Ambas as configurações reduziram significativamente a pressão parcial de dióxido de carbono sistêmico. Como o fluxo sanguíneo na oxigenação por membrana extracorpórea aumentou, a resistência do oxigenador diminuiu inicialmente, com aumento posterior, com fluxos sanguíneos mais altos, mas pouco efeito clínico. Conclusão: A associação de oxigenadores em paralelo ou em série durante o suporte com oxigenação veno-venosa por membrana extracorpórea proporciona um modesto aumento na depuração da pressão parcial de dióxido de carbono, com leve melhora na oxigenação. O efeito das associações de oxigenadores nas pressões de circuitos extracorpóreos é mínimo.


ABSTRACT Objective: To characterize the pressures, resistances, oxygenation, and decarboxylation efficacy of two oxygenators associated in series or in parallel during venous-venous extracorporeal membrane oxygenation support. Methods: Using the results of a swine severe respiratory failure associated with multiple organ dysfunction venous-venous extracorporeal membrane oxygenation support model and mathematical modeling, we explored the effects on oxygenation, decarboxylation and circuit pressures of in-parallel and in-series associations of oxygenators. Results: Five animals with a median weight of 80kg were tested. Both configurations increased the oxygen partial pressure after the oxygenators. The return cannula oxygen content was also slightly higher, but the impact on systemic oxygenation was minimal using oxygenators with a high rated flow (~ 7L/minute). Both configurations significantly reduced the systemic carbon dioxide partial pressure. As the extracorporeal membrane oxygenation blood flow increased, the oxygenator resistance decreased initially with a further increase with higher blood flows but with a small clinical impact. Conclusion: Association of oxygenators in parallel or in series during venous-venous extracorporeal membrane oxygenation support provides a modest increase in carbon dioxide partial pressure removal with a slight improvement in oxygenation. The effect of oxygenator associations on extracorporeal circuit pressures is minimal.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA