Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Synchrotron Radiat ; 29(Pt 4): 1027-1032, 2022 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-35787570

RESUMEN

Microbeam radiotherapy could help to cure malignant tumours which are currently still considered therapy-resistant. With an irradiation target in the thoracic cavity, the heart would be one of the most important organs at risk. To assess the acute adverse effects of microbeam irradiation in the heart, a powerful ex vivo tool was created by combining the Langendorff model of the isolated beating mammalian heart with X-Tream dosimetry. In a first pilot experiment conducted at the Biomedical and Imaging Beamline of the Australian Synchrotron, the system was tested at a microbeam peak dose approximately ten times higher than the anticipated future microbeam irradiation treatment doses. The entire heart was irradiated with a dose of 4000 Gy at a dose rate of >6000 Gy s-1, using an array of 50 µm-wide microbeams spaced at a centre-to-centre distance of 400 µm. Although temporary arrhythmias were seen, they reverted spontaneously to a stable rhythm and no cardiac arrest occurred. This amazing preservation of cardiac function is promising for future therapeutic approaches.


Asunto(s)
Radiometría , Sincrotrones , Animales , Australia , Mamíferos , Radiometría/métodos
2.
Int J Mol Sci ; 23(15)2022 Jul 28.
Artículo en Inglés | MEDLINE | ID: mdl-35955454

RESUMEN

Microbeam radiotherapy (MRT), an experimental high-dose rate concept with spatial fractionation at the micrometre range, has shown a high therapeutic potential as well as good preservation of normal tissue function in pre-clinical studies. We investigated the suitability of MRT as a simultaneously integrated boost (SIB) in conventional whole-brain irradiation (WBRT). A 174 Gy MRT SIB was administered with an array of quasi-parallel, 50 µm wide microbeams spaced at a centre-to-centre distance of 400 µm either on the first or last day of a 5 × 4 Gy radiotherapy schedule in healthy adult C57 BL/6J mice and in F98 glioma cell cultures. The animals were observed for signs of intracranial pressure and focal neurologic signs. Colony counts were conducted in F98 glioma cell cultures. No signs of acute adverse effects were observed in any of the irradiated animals within 3 days after the last irradiation fraction. The tumoricidal effect on F98 cell in vitro was higher when the MRT boost was delivered on the first day of the irradiation course, as opposed to the last day. Therefore, the MRT SIB should be integrated into a clinical radiotherapy schedule as early as possible.


Asunto(s)
Neoplasias Encefálicas , Glioma , Animales , Encéfalo/efectos de la radiación , Neoplasias Encefálicas/radioterapia , Fraccionamiento de la Dosis de Radiación , Glioma/radioterapia , Ratones , Dosis de Radiación , Sincrotrones
3.
Int J Mol Sci ; 23(17)2022 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-36077349

RESUMEN

Radiotherapy is an important component in the treatment of lung cancer, one of the most common cancers worldwide, frequently resulting in death within only a few years of diagnosis. In order to evaluate new therapeutic approaches and compare their efficiency with regard to tumour control at a pre-clinical stage, it is important to develop standardized samples which can serve as inter-institutional outcome controls, independent of differences in local technical parameters or specific techniques. Recent developments in 3D bioprinting techniques could provide a sophisticated solution to this challenge. We have conducted a pilot project to evaluate the suitability of standardized samples generated from 3D printed human lung cancer cells in radiotherapy studies. The samples were irradiated at high dose rates using both broad beam and microbeam techniques. We found the 3D printed constructs to be sufficiently mechanically stable for use in microbeam studies with peak doses up to 400 Gy to test for cytotoxicity, DNA damage, and cancer cell death in vitro. The results of this study show how 3D structures generated from human lung cancer cells in an additive printing process can be used to study the effects of radiotherapy in a standardized manner.


Asunto(s)
Bioimpresión , Neoplasias Pulmonares , Humanos , Neoplasias Pulmonares/radioterapia , Proyectos Piloto , Impresión Tridimensional
4.
J Synchrotron Radiat ; 28(Pt 2): 410-418, 2021 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-33650552

RESUMEN

It has been shown previously both in vitro and in vivo that microbeam irradiation (MBI) can control malignant tumour cells more effectively than the clinically established concepts of broad beam irradiation. With the aim to extend the international capacity for microbeam research, the first MBI experiment at the biomedical beamline SYRMEP of the Italian synchrotron facility ELETTRA has been conducted. Using a multislit collimator produced by the company TECOMET, arrays of quasi-parallel microbeams were successfully generated with a beam width of 50 µm and a centre-to-centre distance of 400 µm. Murine melanoma cell cultures were irradiated with a target dose of approximately 65 Gy at a mean photon energy of ∼30 keV with a dose rate of 70 Gy s-1 and a peak-to-valley dose of ∼123. This work demonstrated a melanoma cell reduction of approximately 80% after MBI. It is suggested that, while a high energy is essential to achieve high dose rates in order to deposit high treatment doses in a short time in a deep-seated target, for in vitro studies and for the treatment of superficial tumours a spectrum in the lower energy range might be equally suitable or even advantageous.


Asunto(s)
Fotones , Sincrotrones , Animales , Ratones , Método de Montecarlo
5.
J Synchrotron Radiat ; 21(Pt 1): 242-50, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24365943

RESUMEN

Gold nanoparticles are excellent intracellular markers in X-ray imaging. Having shown previously the suitability of gold nanoparticles to detect small groups of cells with the synchrotron-based computed tomography (CT) technique both ex vivo and in vivo, it is now demonstrated that even single-cell resolution can be obtained in the brain at least ex vivo. Working in a small animal model of malignant brain tumour, the image quality obtained with different imaging modalities was compared. To generate the brain tumour, 1 × 10(5) C6 glioma cells were loaded with gold nanoparticles and implanted in the right cerebral hemisphere of an adult rat. Raw data were acquired with absorption X-ray CT followed by a local tomography technique based on synchrotron X-ray absorption yielding single-cell resolution. The reconstructed synchrotron X-ray images were compared with images obtained by small animal magnetic resonance imaging. The presence of gold nanoparticles in the tumour tissue was verified in histological sections.


Asunto(s)
Encéfalo/citología , Oro/química , Nanopartículas del Metal , Análisis de la Célula Individual , Sincrotrones , Tomografía Computarizada por Rayos X/métodos , Animales , Neoplasias Encefálicas/patología , Glioma/patología , Imagen por Resonancia Magnética , Ratas , Ratas Wistar
6.
Nanomedicine ; 9(2): 284-92, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22841913

RESUMEN

The ability to perform cell tracking using x-ray computed tomography combined with gold nanoparticles has been demonstrated recently on ex vivo samples using different malignant and nonmalignant cell lines. Here we proved the concept of the method for in vivo assessment in a small-animal model of malignant brain tumors. The limitations of the method due to radiation dose constraints were investigated using Monte Carlo simulations. Taking into consideration different x-ray entrance doses and the spatial resolution, the visibility of the cell clusters was evaluated. The results of the experiments conducted on mice implanted with F98 tumor cells confirmed the prediction of the Monte Carlo calculations. Small clusters of cells exogenously loaded with gold nanoparticles could be visualized using our in vivo method. FROM THE CLINICAL EDITOR: This article discusses the use of CT-based detection of gold nanoparticle loaded cells of interest in small-animal models of malignant brain tumors, where small clusters of cells loaded with gold nanoparticles could be visualized.


Asunto(s)
Neoplasias Encefálicas/diagnóstico por imagen , Encéfalo/diagnóstico por imagen , Oro , Nanopartículas del Metal , Tomografía Computarizada por Rayos X/métodos , Animales , Línea Celular Tumoral , Oro/análisis , Masculino , Nanopartículas del Metal/análisis , Ratones , Ratones Desnudos , Método de Montecarlo , Ratas
7.
Acta Neurochir Suppl ; 117: 13-7, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23652651

RESUMEN

OBJECTIVE: In order to improve image quality in a simultaneous fMRI-EEG study with patients suffering from the involuntary movements typical for Huntington's disease, the aim was to develop a technique for immobilizing the heads of our patients inside an MRI head coil. METHODS: We modified a mask technique previously used for reliable repositioning in temporally fractionated radiotherapy. The mask was tested in three patients with Huntington's disease, acquiring structural and functional MR images with simultaneous EEG with and without the mask. RESULTS: Image as well as EEG signal quality were significantly improved in patients wearing the mask. However, the image quality with mask was comparable to acquisitions from patients without movement disorders only in patients with light to moderate dyskinesia. Although image quality was also significantly improved in a patient suffering from severe dyskinesia with quasi-continuous involuntary movements, the quality of both the MR images as well as the EEG signal was lower than what would be expected in a healthy control person. CONCLUSION: We have succeeded in developing a mask that fits into the MRI head coil, does not disturb the MRI signal, and significantly improves both fMRI and EEG signal quality.


Asunto(s)
Encéfalo/irrigación sanguínea , Encéfalo/fisiopatología , Enfermedad de Huntington/diagnóstico , Imagen por Resonancia Magnética/métodos , Electroencefalografía/métodos , Diseño de Equipo , Humanos , Enfermedad de Huntington/fisiopatología , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética/instrumentación , Máscaras , Oxígeno/sangre , Restricción Física/instrumentación , Restricción Física/métodos , Índice de Severidad de la Enfermedad
8.
Neurol Int ; 15(3): 896-907, 2023 Jul 24.
Artículo en Inglés | MEDLINE | ID: mdl-37489363

RESUMEN

High-resolution imaging in small animal models of neurologic disease is a technical challenge. In a pilot project, we have explored a non-destructive synchrotron imaging technique for the 3D visualization of intracerebral tissue transplants in a well-established small animal model of Huntington's disease. Four adult female Sprague Dawley rats each received injections of 0.12 M quinolinic acid (QA) into two target positions in the left striatum, thus creating unilateral left-sided striatal lesions similar to those frequently seen in patients suffering from Huntington's disease. One week after lesioning, the animals received transplants prepared from whole ganglionic eminences (wGEs) obtained from 13- to 14-day-old rat embryos. Of the four lesioned animals, three received transplants of GNP-loaded cells and one animal received a transplant of naïve cells, serving as control. Post-mortem synchrotron-based microCT was used to obtain images of the neurotransplants. The images obtained of GNP-loaded tissue transplants at the synchrotron corresponded in size and shape to the histological images of transplants developed from naïve cells. Thus, we conclude that non-destructive synchrotron imaging techniques such as phase-contrast imaging are suitable to obtain high-resolution images of GNP-loaded tissue transplants.

9.
Cancers (Basel) ; 15(9)2023 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-37173938

RESUMEN

Microbeam radiotherapy (MRT), a high dose rate radiotherapy technique using spatial dose fractionation at the micrometre range, has shown a high therapeutic efficacy in vivo in different tumour entities, including lung cancer. We have conducted a toxicity study for the spinal cord as organ of risk during irradiation of a target in the thoracic cavity. In young adult rats, the lower thoracic spinal cord was irradiated over a length of 2 cm with an array of quasi-parallel microbeams of 50 µm width, spaced at a centre-to-centre distance of 400 µm, with MRT peak doses up to 800 Gy. No acute or subacute adverse effects were observed within the first week after irradiation up to MRT peak doses of 400 Gy. No significant differences were seen between irradiated animals and non-irradiated controls in motor function and sensitivity, open field test and somatosensory evoked potentials (SSEP). After irradiation with MRT peak doses of 450-800 Gy, dose-dependent neurologic signs occurred. Provided that long-term studies do not reveal significant morbidity due to late toxicity, an MRT dose of 400 Gy can be considered safe for the spinal cord in the tested beam geometry and field size.

10.
Biomimetics (Basel) ; 8(2)2023 May 31.
Artículo en Inglés | MEDLINE | ID: mdl-37366825

RESUMEN

The production of anthropomorphic phantoms generated from tissue-equivalent materials is challenging but offers an excellent copy of the typical environment encountered in typical patients. High-quality dosimetry measurements and the correlation of the measured dose with the biological effects elicited by it are a prerequisite in preparation of clinical trials with novel radiotherapy approaches. We designed and produced a partial upper arm phantom from tissue-equivalent materials for use in experimental high-dose-rate radiotherapy. The phantom was compared to original patient data using density values and Hounsfield units obtained from CT scans. Dose simulations were conducted for broad-beam irradiation and microbeam radiotherapy (MRT) and compared to values measured in a synchrotron radiation experiment. Finally, we validated the phantom in a pilot experiment with human primary melanoma cells.

11.
Int J Radiat Biol ; 98(3): 466-473, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34995153

RESUMEN

PURPOSE: Microbeam radiotherapy (MRT) is a still experimental radiotherapy approach. Two combined parameters contribute to an excellent normal tissue protection and an improved control of malignant tumors in small animal models, compared to conventional radiotherapy: dose deposition at a high dose rate and spatial fractionation at the micrometre level. The international microbeam research community expects to see clinical MRT trials within the next ten years.Physics-associated research is still widely regarded as a male domain. Thus, the question was asked whether this is reflected in the scientific contributions to the field of microbeam radiotherapy. METHOD: A literature search was conducted using Pubmed, Semantic Scholar and other sources to look specifically for female contributors to the field of microbeam radiotherapy development. CONCLUSION: The original idea for MRT was patented in 1994 by an all-male research team. In approximately 50% of all publications related to microbeam radiotherapy, however, either the first or the senior author is a woman. The contribution of those women who have been driving the development of both technical and biomedical aspects of MRT in the last two decades is highlighted.


Asunto(s)
Belleza , Neoplasias , Animales , Fraccionamiento de la Dosis de Radiación , Femenino , Humanos , Masculino , Neoplasias/radioterapia , Ratas , Sincrotrones
12.
Cancers (Basel) ; 14(23)2022 Dec 02.
Artículo en Inglés | MEDLINE | ID: mdl-36497446

RESUMEN

Monoplanar microbeam irradiation (MBI) and pencilbeam irradiation (PBI) are two new concepts of high dose rate radiotherapy, combined with spatial dose fractionation at the micrometre range. In a small animal model, we have explored the concept of integrating MBI or PBI as a simultaneously integrated boost (SIB), either at the beginning or at the end of a conventional, low-dose rate schedule of 5x4 Gy broad beam (BB) whole brain radiotherapy (WBRT). MBI was administered as array of 50 µm wide, quasi-parallel microbeams. For PBI, the target was covered with an array of 50 µm × 50 µm pencilbeams. In both techniques, the centre-to-centre distance was 400 µm. To assure that the entire brain received a dose of at least 4 Gy in all irradiated animals, the peak doses were calculated based on the daily BB fraction to approximate the valley dose. The results of our study have shown that the sequence of the BB irradiation fractions and the microbeam SIB is important to limit the risk of acute adverse effects, including epileptic seizures and death. The microbeam SIB should be integrated early rather than late in the irradiation schedule.

13.
Int J Radiat Oncol Biol Phys ; 114(1): 143-152, 2022 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-35533907

RESUMEN

PURPOSE: Microbeam radiation therapy (MRT) has shown several advantages compared with conventional broad-beam radiation therapy in small animal models, including a better preservation of normal tissue function and improved drug delivery based on a rapidly increased vascular permeability in the target region. Normal tissue tolerance is the limiting factor in clinical radiation therapy. Knowledge of the normal tissue tolerance of organs at risk is therefore a prerequisite in evaluating any new radiation therapy approach. With an irradiation target in the thoracic cavity, the heart would be the most important organ at risk. METHODS AND MATERIALS: We used the ex vivo beating rodent heart in the Langendorff perfusion system at the synchrotron to administer microbeam irradiation (MBI) with a peak dose of 40 or 400 Gy. By continuously recording the electrocardiogram, the left ventricular pressure, and the aortic pressure before, during and after MBI, we were able to assess acute and subacute effects of MBI on electrophysiological and mechanical cardiac function. In addition, we analyzed histologic and ultrastructural sequelae caused by MBI. RESULTS: There were no significant changes in heart rate, heart rate variability, systolic increase of left ventricular pressure or aortic pressure. Moreover, the changes of heart rate, left ventricular pressure and aortic pressure by adding 10-5 mol/L norepinephrine to the perfusate, were also not significant between MBI and sham experiments. However, the rate-pressure product as a surrogate marker for maximum workload after MBI was significantly lower compared with sham-irradiated controls. On the structural level, no severe membranous, sarcomeric, mitochondrial or nuclear changes caused by MBI were detected by desmin immunohistochemistry and electron microscopy. CONCLUSIONS: With respect to acute and subacute toxicity, an MBI peak dose up to 400 Gy did not result in severe changes in cardiac electrophysiology or mechanics.


Asunto(s)
Roedores , Sincrotrones , Animales , Corazón , Inmunohistoquímica , Modelos Animales
14.
Cancers (Basel) ; 14(20)2022 Oct 20.
Artículo en Inglés | MEDLINE | ID: mdl-36291920

RESUMEN

High dose rate radiotherapies such as FLASH and microbeam radiotherapy (MRT) both have developed to the stage of first veterinary studies within the last decade. With the development of a new research tool for high dose rate radiotherapy at the end station P61A of the synchrotron beamline P61 on the DESY campus in Hamburg, we increased the research capacity in this field to speed up the translation of the radiotherapy techniques which are still experimental, from bench to bedside. At P61, dose rates of several hundred Gy/s can be delivered. Compared to dedicated biomedical beamlines, the beam width available for MRT experiments is a very restrictive factor. We developed two model systems specifically to suit these specific technical parameters and tested them in a first set of experiments.

15.
Cells ; 12(1)2022 12 31.
Artículo en Inglés | MEDLINE | ID: mdl-36611969

RESUMEN

BACKGROUND: High-dose-rate radiotherapy has shown promising results with respect to normal tissue preservation. We developed an ex vivo model to study the physiological effects of experimental radiotherapy in the rodent esophageal smooth muscle. METHODS: We assessed the physiological parameters of the esophageal function in ex vivo preparations of the proximal, middle, and distal segments in the organ bath. High-dose-rate synchrotron irradiation was conducted using both the microbeam irradiation (MBI) technique with peak doses greater than 200 Gy and broadbeam irradiation (BBI) with doses ranging between 3.5-4 Gy. RESULTS: Neither MBI nor BBI affected the function of the contractile apparatus. While peak latency and maximal force change were not affected in the BBI group, and no changes were seen in the proximal esophagus segments after MBI, a significant increase in peak latency and a decrease in maximal force change was observed in the middle and distal esophageal segments. CONCLUSION: No severe changes in physiological parameters of esophageal contraction were determined after high-dose-rate radiotherapy in our model, but our results indicate a delayed esophageal function. From the clinical perspective, the observed increase in peak latency and decreased maximal force change may indicate delayed esophageal transit.


Asunto(s)
Esófago , Roedores , Animales , Contracción Muscular/fisiología , Músculo Liso
16.
Nanomedicine ; 7(5): 647-54, 2011 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21333753

RESUMEN

The ability to track cells in small-animal models of human disease is important because it gives the potential to improve our understanding of the processes of disease progression as well as our understanding of the therapeutic effects of interventions. In this study gold nanoparticles have been used as a permanent marker of implanted normal and malignant cell grafts in combination with a suitable x-ray apparatus. Using x-ray computed tomography the micrometric three-dimensional distribution of these marked cells could be displayed with penetration depth, high cell sensitivity and high spatial resolution in rodent models of human diseases. In principle the method allows quantification of cell numbers at any anatomical location over time in small animals.


Asunto(s)
Rastreo Celular/métodos , Oro/química , Nanopartículas del Metal/química , Coloración y Etiquetado/métodos , Tomografía Computarizada por Rayos X/métodos , Animales , Línea Celular , Línea Celular Tumoral , Movimiento Celular , Células Cultivadas , Modelos Animales de Enfermedad , Cabeza/diagnóstico por imagen , Humanos , Células Madre Mesenquimatosas/diagnóstico por imagen , Ratas , Ratas Wistar
17.
PLoS One ; 16(6): e0253553, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34143847

RESUMEN

For the last years, copper complexes have been intensively implicated in biomedical research as components of cancer treatment. Herewith, we provide highlights of the synthesis, physical measurements, structural characterization of the newly developed Cu(II) chelates of Schiff Bases, Cu(Picolinyl-L-Tryptopahanate)2, Cu(Picolinyl-L-Tyrosinate)2, Cu(Isonicotinyl-L-Tyrosinate)2, Cu(Picolinyl-L-Phenylalaninate)2, Cu(Nicotinyl-L-Phenylalaninate)2, Cu(Isonicotinyl-L-Phenylalaninate)2, and their radioenhancement capacity at kV and MV ranges of irradiation of human lung carcinoma epithelial cells in vitro. The methods of cell growth, viability and proliferation were used. All compounds exerted very potent radioenhancer capacities in the irradiated lung carcinoma cells at both kV and MV ranges in a 100 µM concentration. At a concentration of 10 µM, only Cu(Picolinyl-L-Tyrosinate)2, Cu(Isonicotinyl-L-Tyrosinate)2, Cu(Picolinyl-L-Phenylalaninate)2 possessed radioenhancer properties at kV and MV ranges. Cu(Picolinyl-L-Tryptophanate)2 showed radioenhancer properties only at kV range. Cu(Nicotinyl-L-Phenylalaninate)2 and Cu(Isonicotinyl-L-Phenylalaninate)2 showed remarkable radioenhancer activity only at MV range. All compounds acted in dose-dependent manner at both tested energy ranges. These copper (II) compounds, in combination with 1 Gy irradiation at either 120 kV or 6 MV, are more efficient at delaying cell growth of lung cancer cells and at reducing cell viability in vitro than the irradiation administered alone. Thus, we have demonstrated that the studied copper compounds have a good potential for radioenhancement.


Asunto(s)
Complejos de Coordinación/química , Cobre/química , Neoplasias Pulmonares/diagnóstico por imagen , Intensificación de Imagen Radiográfica/métodos , Bases de Schiff/química , Línea Celular Tumoral , Proliferación Celular , Supervivencia Celular , Humanos
18.
Int J Radiat Oncol Biol Phys ; 110(2): 521-525, 2021 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-33383127

RESUMEN

PURPOSE: Radiation therapy is an important treatment component for patients with lung cancer. However, the survival time gained with clinical radiation therapy techniques is relatively short. Data from preclinical experiments suggest that synchrotron microbeam radiation therapy could be much better suited to control malignant brain tumors than current clinical concepts of radiation therapy. Even at peak doses of several hundred gray, the extent of functional deficits is low. METHODS AND MATERIALS: We have developed the first mouse model to study the effects of microbeam irradiation in lung tissue. RESULTS: Up to peak doses of 400 Gy, no acute adverse effects were seen. CONCLUSION: This model is well suited to explore the potential of microbeam radiation therapy in the treatment of lung cancer and the response of normal lung tissue and organs at risk.


Asunto(s)
Modelos Animales de Enfermedad , Pulmón/efectos de la radiación , Sincrotrones , Animales , Cardiotoxicidad , Estudios de Factibilidad , Histonas/análisis , Neoplasias Pulmonares/radioterapia , Masculino , Ratones , Ratones Endogámicos C57BL , Órganos en Riesgo/efectos de la radiación , Proyectos Piloto , Dosificación Radioterapéutica
19.
Front Neurosci ; 14: 598266, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33328869

RESUMEN

An abnormal glutamate signaling of glioblastoma may contribute to both tumor progression and the generation of glioma-associated epileptic seizures. We hypothesized that the AMPA receptor antagonist perampanel (PER) could attenuate tumor growth and epileptic events. F98 glioma cells, grown orthotopically in Fischer rats, were employed as a model of glioma to investigate the therapeutic efficiency of PER (15 mg/kg) as adjuvant to standard radiochemotherapy (RCT). The epileptiform phenotype was investigated by video-EEG analysis and field potential recordings. Effects on glioma progression were estimated by tumor size quantification, survival analysis and immunohistological staining. Our data revealed that orthotopically-growing F98 glioma promote an epileptiform phenotype in rats. RCT reduced the tumor size and prolonged the survival of the animals. The adjuvant administration of PER had no effect on tumor progression. The tumor-associated epileptic events were abolished by PER application or RCT respectively, to initial baseline levels. Remarkably, PER preserved the glutamatergic network activity on healthy peritumoral tissue in RCT-treated animals. F98 tumors are not only a robust model to investigate glioma progression, but also a viable model to simulate a glioma-associated epileptiform phenotype. Furthermore, our data indicate that PER acts as a potent anticonvulsant and may protect the tumor-surrounding tissue as adjuvant to RCT, but failed to attenuate tumor growth or promote animal survival.

20.
Sci Rep ; 9(1): 17082, 2019 11 19.
Artículo en Inglés | MEDLINE | ID: mdl-31745153

RESUMEN

The functional roles of the Caudate nucleus (Cd) are well known. Selective Cd lesions can be found in neurological disorders. However, little is known about the dynamics of the behavioral changes during progressive Cd ablation. Current stereotactic radiosurgery technologies allow the progressive ablation of a brain region with limited adverse effects in surrounding normal tissues. This could be of high interest for the study of the modified behavioral functions in relation with the degree of impairment of the brain structures. Using hypofractionated stereotactic radiotherapy combined with synchrotron microbeam radiation, we investigated, during one year after irradiation, the effects of unilateral radio-ablation of the right Cd on the behavior of Yucatan minipigs. The right Cd was irradiated to a minimal dose of 35.5 Gy delivered in three fractions. MRI-based morphological brain integrity and behavioral functions, i.e. locomotion, motivation/hedonism were assessed. We detected a progressive radio-necrosis leading to a quasi-total ablation one year after irradiation, with an additional alteration of surrounding areas. Transitory changes in the motivation/hedonism were firstly detected, then on locomotion, suggesting the influence of different compensatory mechanisms depending on the functions related to Cd and possibly some surrounding areas. We concluded that early behavioral changes related to eating functions are relevant markers for the early detection of ongoing lesions occurring in Cd-related neurological disorders.


Asunto(s)
Conducta Animal/efectos de la radiación , Encéfalo/patología , Núcleo Caudado/patología , Irradiación Craneana/efectos adversos , Conducta Alimentaria/efectos de la radiación , Locomoción/efectos de la radiación , Traumatismos por Radiación/patología , Animales , Encéfalo/efectos de la radiación , Núcleo Caudado/efectos de la radiación , Masculino , Traumatismos por Radiación/etiología , Porcinos , Porcinos Enanos , Sincrotrones
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA