Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-38776147

RESUMEN

PURPOSE: To determine the effect of aromatherapy on postoperative anxiety and pain in patients undergoing oculoplastic surgery. METHODS: A randomized controlled study of 60 patients who underwent monitored anesthesia care sedation for oculoplastic procedures from August 2018 to November 2020. Patients were randomized to an aromatherapy (n = 32) or placebo (n = 28) condition. Anxiety was measured with State-Trait Anxiety Inventory and visual analog scale for anxiety. Pain was measured with a visual analog scale for pain. RESULTS: Compared with control patients, aromatherapy patients had significantly lower postoperative State-Trait Anxiety Inventory state anxiety (24.1 vs. 29.1; p = 0.05) and visual analog scale pain scores (1.9 vs. 3.2; p = 0.05). Aromatherapy patients also had shorter stays in the postanesthesia care unit than control patients (57.7 vs. 79.4 minutes; p = 0.03). CONCLUSIONS: Patients who received aromatherapy reported lower postoperative anxiety and pain. Aromatherapy may be a useful adjuvant analgesic and/or anxiolytic for patients undergoing oculoplastic procedures with monitored anesthesia care sedation.

2.
Ophthalmic Plast Reconstr Surg ; 39(6): e194-e197, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37405738

RESUMEN

VEXAS (Vacuoles, E1 enzyme, X-linked, Autoinflammatory, Somatic) syndrome is an adult-onset autoinflammatory disorder characterized by systemic inflammation (vasculitis, arthritis, chondritis, dermatosis) and hematologic abnormalities (thrombosis, cytopenia, vacuolization of marrow precursors). The patient demonstrated some of the adult-onset inflammatory and hematologic features, in addition to recurrent eye pain, chemosis and orbital inflammation. This case describes an instance of VEXAS syndrome in a patient with uncommon orbital symptoms such as scleritis and myositis.


Asunto(s)
Síndromes Mielodisplásicos , Miositis , Adulto , Humanos , Inflamación , Dolor Ocular , Mutación
3.
Ophthalmic Plast Reconstr Surg ; 38(5): 503-506, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35699217

RESUMEN

PURPOSE: This perspective explores the Food and Drug Administration (FDA) 510(k) program, occasionally referred to as premarket notification, which facilitates faster marketing of Class II medical devices, such as orbital implants by demonstrating "substantial equivalence" to previously approved devices. This allows for FDA clearance, rather than FDA approval of orbital implants via comparison to currently marketed implants rather than clinically proven safety standards. METHODS: Utilizing the FDA's publicly available 510(k) Premarket Notification database, we conducted a thorough search of FDA-cleared orbital implants dating back to the inception of the 510(k) process in 1976. RESULTS: We found that 29 orbital implants received 510(k) FDA clearance between 1987 and 2022. Four of the 29 implants were recalled. Only 9 of 29 implants had available data on their predicate or comparison devices; of these 9, 3 implants received clearance based on devices that were subsequently recalled. CONCLUSIONS: This investigation into premarket approval of orbital implants identifies a shortcoming in the FDA 510(k) approval process. Long-term implant-associated morbidity is difficult to predict during premarket analysis but is further complicated for 510(k) cleared implants since devices approved based on substantial equivalence to recalled devices may not be automatically recalled. Clinicians should be aware of the approval process for the devices they select, and review of the 510(k) process, especially as it applies to substantial equivalence to devices subsequently recalled is warranted.


Asunto(s)
Aprobación de Recursos , Implantes Orbitales , Bases de Datos Factuales , Humanos , Estados Unidos , United States Food and Drug Administration
4.
Exp Eye Res ; 198: 108140, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32649951

RESUMEN

PURPOSE: Eyelid basal cell carcinoma (BCC) is the most common eyelid malignancy. Metabolic reprogramming is critical in tumorigenesis, but the metabolic feature of eyelid BCC remains elusive. In this study, we aim to reveal the metabolic profile in eyelid BCC using targeted metabolomics. Eyelid samples were collected from patients who had removal of BCC and from control patients who underwent blepharoplasty. Multivariate analysis of metabolomics data distinguished the two groups, indicating that eyelid BCC has significantly different metabolome than the healthy tissue. We found 16 increased and 11 decreased metabolites in the BCC tissues. These metabolites were highly enriched in the metabolism of nicotinamide adenine dinucleotide (NAD), glutathione metabolism, polyamine metabolism, and the metabolism of glycine, serine, threonine, arginine and proline. amino acid metabolism. Metabolites from NAD metabolism (Nicotinamide; Nicotinamide riboside; N1-Methylnicotinamide) had the highest sensitivity, specificity, and prediction accuracy in a prediction model for eyelid BCC. In conclusion, eyelid BCC has a signature change of cell metabolome. Metabolites in NAD metabolic pathways could potentially be biomarkers or therapeutic targets for eyelid BCC.


Asunto(s)
Carcinoma Basocelular/metabolismo , Neoplasias de los Párpados/metabolismo , Metaboloma/fisiología , Metabolómica/métodos , Anciano , Biomarcadores de Tumor/metabolismo , Carcinoma Basocelular/patología , Neoplasias de los Párpados/patología , Femenino , Humanos , Masculino
5.
Strabismus ; 32(2): 85-90, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38708857

RESUMEN

INTRODUCTION: The Spiral of Tillaux describes the historically accepted insertion distances of the medial rectus, inferior rectus, lateral rectus, and superior rectus from the limbus: 5.5 mm, 6.5 mm, 6.9 mm, and 7.7 mm, respectively. The corneal diameters are historically accepted to be 11.7 mm horizontally and 10.6 mm vertically in adults. We investigated the variability of the insertion distances of the extraocular rectus muscles from the limbus as well as the corneal diameters using eyes from human cadavers and compared our measurements to these historically accepted measurements. METHODS: A sample of 60 eyes were included. For each eye, a 360 peritomy was conducted and the conjunctiva bluntly dissected to view the sclera. Muscle hooks were utilized to isolate the extraocular rectus muscles. Calipers were used to measure the insertion distances of the rectus muscles as well as the corneal diameters. RESULTS: The mean rectus muscle insertions distances from the limbus were medial 5.28 mm, inferior 5.72 mm, lateral 6.40 mm, and superior 6.78 mm. These insertion distances were shorter than the historical benchmarks (p < .01). However, observed maximum distances of the rectus muscles were all greater than the historically accepted benchmarks, with the medial, inferior, lateral, and superior rectus muscles being 6.4 mm, 7.3 mm, 7.4 mm, and 7.8 m from the limbus, respectively. The mean width and height of the cornea were 11.7 mm and 10.7 mm, respectively, and similar to the expected ranges. CONCLUSION: This study concludes that variability does exist from the historically accepted Spiral of Tillaux measurements. In addition, significant variation exists between male and female rectus muscle insertions. However, we did confirm that the rectus muscles followed the same spiral pattern described by the Spiral of Tillaux and concluded that the corneal diameters are consistent with previously accepted values.


Asunto(s)
Cadáver , Córnea , Músculos Oculomotores , Humanos , Femenino , Masculino , Músculos Oculomotores/anatomía & histología , Anciano , Córnea/anatomía & histología , Persona de Mediana Edad , Anciano de 80 o más Años , Adulto
6.
Clin Anat ; 26(5): 547-50, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22431436

RESUMEN

Much of the life of Francesco Parona and many of his contributions to medicine are unknown outside of Europe. Parona made novel contributions to many surgical techniques and medical treatments and was an active member of society and the Italian political regime. Parona's name lives on eponymously by his "space" in the forearm. This paper will discuss the personal life and medical contributions of Francesco Parona.


Asunto(s)
Anatomía/historia , Cirugía General/historia , Disfunción Eréctil/cirugía , Femenino , Historia del Siglo XIX , Historia del Siglo XX , Humanos , Italia , Masculino , Disrafia Espinal/cirugía , Tuberculosis de la Columna Vertebral/cirugía
8.
Clin Anat ; 24(5): 539-43, 2011 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-21412854

RESUMEN

There have been many advances in the medical world over time that have greatly contributed to ameliorating and prolonging human life. The employment of surgical anesthesia is arguably one of the greatest medical discoveries of all time, and has immensely broadened our ability to treat the ill. While Dr. Henry Jacob Bigelow (1818-1890) was not the inventor of anesthesia, he was the first to publish and advocate its use in the 19th century (Bigelow and Bigelow [1894] A Memoir of Henry Jacob Bigelow, Boston: Little, Brown, and Company; Harrington and Mumford [1905] The Harvard Medical School: A History, Narrative and Documentary, Vol 2, New York: Lewis Publishing Company). Bigelow also contributed to revolutionizing the fields of orthopedic and urologic surgery, publishing extensive research on subjects where there was previously very little knowledge, and even developing new techniques. He also impacted the field of neuropsychiatry in his publication regarding Phineas Gage. His contributions to the medical field have set him apart as one of the most influential and famous surgeons of America in the 19th century. Anatomically, he will be remembered eponymously for his iliofemoral ligament and septum in the femur.


Asunto(s)
Anatomía/historia , Anestesia/historia , Cirugía General/historia , Historia del Siglo XVIII , Humanos , Estados Unidos
9.
R I Med J (2013) ; 104(9): 70-72, 2021 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-34705914

RESUMEN

Indirect carotid cavernous fistulas (CCFs) are most often spontaneous, but can rarely be caused by trauma. With traumatic etiology, the timeline for the development of symptoms varies significantly and can be difficult to predict. In this report, we discuss the case of a patient found to have an indirect CCF who presented for acutely worsening ocular symptoms and a history of pulsatile tinnitus that began two years prior after a suspected inciting head injury. To our knowledge, no cases have described a traumatic indirect CCF with a similarly extensive indolent course who demonstrated full symptomatic recovery following treatment.


Asunto(s)
Fístula del Seno Cavernoso de la Carótida , Traumatismos Craneocerebrales , Fístula , Acúfeno , Fístula del Seno Cavernoso de la Carótida/diagnóstico por imagen , Fístula del Seno Cavernoso de la Carótida/etiología , Fístula del Seno Cavernoso de la Carótida/terapia , Traumatismos Craneocerebrales/complicaciones , Humanos , Acúfeno/etiología
10.
J Curr Glaucoma Pract ; 13(1): 37-41, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31496560

RESUMEN

AIM: The aim of this study is to assess the effectiveness of suberoylanilide hydroxamic acid (SAHA), a histone deacetylase inhibitor (HDI) with a broad spectrum epigenetic activity, in improving filtration bleb survival as an adjunct therapy to glaucoma filtration surgery (GFS) in the rabbit model. MATERIALS AND METHODS: Eighteen New Zealand White rabbits underwent GFS in the left eye and were randomized to receive either a subconjunctival (SC) injection of 0.1 mL SAHA (9.25 µg/mL) or balanced saline solution (BSS) at the end of surgery, or a 3-minute intraoperative topical application of 0.4 mg/mL mitomycin-C (MMC). Bleb survival and histology were compared. RESULTS: Blebs of rabbits receiving injections of SAHA survived an average (mean ± SD) of 23.2 ± 2.7 days. SAHA rabbits showed a nonsignificant improvement over rabbits that received an injection of BSS, which had a mean survival time of 19.7 ± 2.7 days (p = 0.38) according to a one-way analysis of variance (ANOVA). Eyes receiving intraoperative topical MMC survived an average of 32.5 ± 3.3 days, which is significantly longer than both the control group treated with BSS (p = 0.01) and the experimental group treated with the SAHA (p = 0.0495). SAHA was well tolerated and showed no significant avascularity, necrosis, or conjunctival thinning. CONCLUSION: Although it was well tolerated, a single intraoperative injection of SAHA did not significantly prolong bleb survival in the rabbit model. CLINICAL SIGNIFICANCE: Epigenetic adjuncts hold promise for improving GFS outcome; however, future studies must continue to examine different administration protocols and dosages to substantiate their efficacy. HOW TO CITE THIS ARTICLE: Rodgers CD, Lukowski ZL, et al. Modulating Ocular Scarring in Glaucoma Filtration Surgery Using the Epigenetic Adjunct Suberoylanilide Hydroxamic Acid. J Curr Glaucoma Pract 2019;13(1):37-41.

11.
Case Rep Otolaryngol ; 2018: 4620510, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30057842

RESUMEN

Orbital complications are known risks of endoscopic sinus surgery (ESS). The lamina papyracea and medial rectus muscle are the most commonly injured structures during ESS. Inferior rectus injury is more rare, with only one reported case of isolated inferior rectus injury in the literature. Guidelines for managing ESS-induced inferior rectus injury do not exist, and delayed intervention and management of adjacent sinuses may affect long-term outcomes such as persistent diplopia and disfigurement. In this report, we present a case of a 67-year-old man with diplopia due to isolated left inferior rectus muscle entrapment and injury from violation of the orbital floor during previous ESS. We postulate that an incomplete maxillary antrostomy contributed to scar band formation and entrapment of the inferior rectus muscle after the orbital floor was violated, and advocate early intervention with a wide, complete maxillary antrostomy if the orbital floor is injured during ESS.

12.
PLoS One ; 13(5): e0196968, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29795580

RESUMEN

PURPOSE: To examine the effect of cannula diameter and conjunctival flap method on bleb survival in rabbits undergoing cannula-based glaucoma filtration surgery (GFS). METHODS: Twelve New Zealand White rabbits underwent GFS in both eyes. The twenty-four eyes were divided into four groups. Two of the four groups (N = 12) received limbus-based conjunctival flaps (LBCF), and the other two (N = 12) received fornix-based conjunctival flaps (FBCF). Six FBCF rabbit eyes were implanted with 22-gauge drainage tubes, and the other six were implanted with 26-gauge tubes. Likewise, six LBCF rabbits received 22-gauge drainage tubes and six received 26-gauge tubes. Filtration blebs were evaluated every three days by a masked observer. Bleb failure was defined as the primary endpoint in this study and was recorded after two consecutive flat bleb evaluations. RESULTS: Group 1 (LBCF, 22- gauge cannula) had a mean bleb survival time (Mean ± SD) of 18.7 ± 2.9 days. Group 2 (LBCF, 26-gauge cannula) also had a mean bleb survival time of 18.7 ± 2.9 days. Group 3 (FBCF, 22-gauge cannula) had a mean bleb survival time of 19.2 ± 3.8 days. Group 4 (FBCF, 26-gauge cannula) had a mean bleb survival time of 19.7 ± 4.1 days. A 2-way analysis of variance showed that neither surgical approach nor cannula gauge made a statistically significant difference in bleb survival time (P = 0.634 and P = 0.874). Additionally, there was no significant interaction between cannula gauge and conjunctival flap approach (P = 0.874), suggesting that there was not a combination of drainage gauge and conjunctival flap method that produced superior bleb survival. CONCLUSION: Limbus and fornix-based conjunctival flaps are equally effective in promoting bleb survival using both 22 and 26-gauge cannulas in the rabbit model. The 26-gauge drainage tube may be preferred because its smaller size facilitates the implantation process, reducing the risk of corneal contact.


Asunto(s)
Cánula , Cirugía Filtrante/métodos , Implantes de Drenaje de Glaucoma/veterinaria , Glaucoma/cirugía , Colgajos Quirúrgicos/veterinaria , Animales , Humor Acuoso/metabolismo , Conjuntiva/cirugía , Modelos Animales de Enfermedad , Drenaje , Cirugía Filtrante/instrumentación , Glaucoma/patología , Limbo de la Córnea/cirugía , Conejos
13.
Br J Ophthalmol ; 102(3): 358-363, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-28814418

RESUMEN

BACKGROUND/AIMS: The objective of this study is to evaluate the accuracy and speed of trainees and experienced glaucoma specialists using the MatchedFlicker software against the manual examination of stereoscopic disc photographs for detecting glaucomatous optic disc change. METHODS: Three experienced glaucoma specialists, two resident ophthalmologists and one glaucoma fellow from multiple institutions independently evaluated the same 140 image pairs from 100 glaucomatous/ocular hypertensive eyes using a handheld stereo viewer and the MatchedFlicker programme. Fifty had progression to glaucoma as determined by the Ocular Hypertension Treatment Study (OHTS) Optic Disc Reading Group and endpoint committee, and 50 more were negative controls for progression with photos taken a few minutes apart. Twenty photo pairs from each of the two groups were duplicated for reviewer variability analysis. The initial viewing method was randomised and then alternated for each group of 70 image pairs. Reviewer accuracy and evaluation time for each method were measured. RESULTS: Evaluators averaged 8.6 s faster per image pair (26%) with the MatchedFlicker programme than with the stereo viewer (p=0.0007). Evaluators correctly identified more image pairs when using the MatchedFlicker software over the stereo viewer (p=0.0003). There was no significant difference between the expert and trainee group in speed or overall accuracy for either method. Experts were significantly more consistent than trainees with the duplicate image pairs (p=0.029). Trainees appeared more reluctant to designate eyes as showing glaucoma progression than experts. CONCLUSIONS: Both expert glaucoma specialists and ophthalmologists in various stages of training had greater accuracy and speed with the MatchedFlicker programme than with a handheld stereoscopic viewer.


Asunto(s)
Diagnóstico por Computador/métodos , Glaucoma de Ángulo Abierto/diagnóstico , Internado y Residencia , Oftalmólogos , Disco Óptico/patología , Enfermedades del Nervio Óptico/diagnóstico , Fotograbar/métodos , Progresión de la Enfermedad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Hipertensión Ocular/diagnóstico , Oftalmología/educación , Estudios Prospectivos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Trastornos de la Visión/diagnóstico , Trastornos de la Visión/fisiopatología , Campos Visuales/fisiología
14.
Account Res ; 24(7): 375-383, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28745950

RESUMEN

The importance of transparency with financial ties in biomedical research is widely recognized, and most peer-reviewed journals require declarations of Conflicts of Interest (COI). Nonetheless, variability in the consistency of declarations of COI has been sparsely assessed. To assess consistency and rates of COI declarations in the ophthalmic literature and the effectiveness of journal COI policies. We analyzed consistency and completeness of declaration of COI in the ophthalmic literature and compared the levels of completeness to specific journal requirements. Six-hundred forty-two peer reviewed articles satisfied the inclusion criteria. In 64%, COIs were unreported, in 25% declaration of COI was incomplete, and 11% of the articles reviewed had complete declaration of COI. Of the 33 journals in which the most frequently published authors' articles appeared, 10 required the authors to complete the International Committee of Medical Journal Editors (ICMJE) form or an equivalent form, but this did not affect the rates of COI declaration. In a random sampling of the most frequently published authors in the field of ophthalmology, declaration of COI was low and highly inconsistent. Requiring a standardized COI form has no significant effect on the rate of accurate COI reporting. Our findings lend support to the growing body of literature that shows that journals and editors may need to take a more active role in ensuring accurate and consistent COI reporting.


Asunto(s)
Conflicto de Intereses , Revelación , Revisión por Pares , Políticas Editoriales , Humanos , Publicaciones Periódicas como Asunto , Publicaciones
15.
Case Rep Ophthalmol Med ; 2016: 4148968, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27403362

RESUMEN

Purpose. Acanthamoeba keratitis remains a difficult diagnosis despite advances in genetic and imaging technologies. The purpose of this paper is to highlight the utility of cytology smears for diagnosis of Acanthamoeba keratitis. Methods. This is a case study of the diagnostic course for a patient with suspected Acanthamoeba keratitis. Results. A 40-year-old male with poor contact lens hygiene presented with severe left eye pain. Slit lamp examination showed two peripheral ring infiltrates without an epithelial defect. The epithelium over both infiltrates was removed with a Kimura spatula. Half of the sample was smeared on a dry microscope slide and the other half was submitted for Acanthamoeba culture and PCR. Both culture and PCR were negative for Acanthamoeba, but hematoxylin and eosin stain of the smear revealed double-walled cysts. Conclusion. H&E staining of corneal cytology specimens is an efficient and readily available test for diagnosis of Acanthamoeba keratitis.

16.
Am J Ophthalmol ; 167: 88-95, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27038890

RESUMEN

PURPOSE: To compare the accuracy and speed of using the computerized MatchedFlicker software program (EyeIC Inc, Narberth, Pennsylvania, USA) to evaluate glaucomatous optic disc change against the traditional gold standard of manually examining stereoscopic disc photographs. DESIGN: A prospective evaluation of diagnostic technology. METHODS: Two resident ophthalmologists and 1 glaucoma fellow at the University of Florida independently evaluated 140 image pairs from 100 glaucomatous/ocular hypertensive patient eyes using a handheld stereo viewer and the MatchedFlicker program. Fifty had progression to glaucoma as determined by the Ocular Hypertension Treatment Study (OHTS) Optic Disc Reading Group and the OHTS Endpoint Committee in the OHTS, and 50 more had photographs taken a few minutes apart, which were negative controls with no progression. Twenty photograph pairs from each group were duplicated to determine reviewer variability. Photographs were examined in alternating blocks of 70 photograph pairs for each method, with the starting viewing method randomized. Reviewer accuracy and time to review for each method were measured. RESULTS: Using the handheld stereo viewer, the reviewers correctly identified progression or nonprogression in 76.0% of the slide pairs. Using the MatchedFlicker software, 87.6% were correctly identified (P = .011). Evaluator speed averaged 34.1 seconds per image pair with the stereo viewer vs 24.9 seconds with the MatchedFlicker program (P = .044). Overall, Flicker was significantly more specific but less sensitive than stereo slides. Trainees appeared more reluctant to identify glaucoma progression from slides than from Flicker. For the 2 less experienced trainees Flicker was significantly more accurate. CONCLUSION: The MatchedFlicker software had a greater accuracy and was quicker to perform than using a handheld stereoscopic viewer.


Asunto(s)
Diagnóstico por Imagen/métodos , Técnicas de Diagnóstico Oftalmológico , Glaucoma de Ángulo Abierto/diagnóstico , Oftalmología/educación , Disco Óptico/patología , Enfermedades del Nervio Óptico/diagnóstico , Enseñanza , Progresión de la Enfermedad , Educación de Postgrado en Medicina , Reacciones Falso Positivas , Humanos , Internado y Residencia , Fibras Nerviosas/patología , Fotograbar , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados , Células Ganglionares de la Retina/patología , Sensibilidad y Especificidad , Programas Informáticos
17.
Br J Ophthalmol ; 99(12): 1718-24, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26024673

RESUMEN

BACKGROUND/AIMS: To evaluate long-term efficacy of a second glaucoma drainage device (GDD) versus cyclophotocoagulation (CPC) after failure of primary drainage implant. METHODS: This is a non-randomised, retrospective cohort study. A chart review was conducted of patients who underwent GDD surgery between July 1986 and November 2012 requiring further glaucoma procedures for intraocular pressure (IOP) control. An additional GDD was placed in 15 eyes, while 32 eyes underwent CPC. The main outcome measurement was IOP control and/or time to failure of secondary intervention (IOP >18 mm Hg on two sequential measurements). RESULTS: Mean follow-up after the second procedure was 63±65.8 months (range 6-254 months) in the CPC group and 132±91.8 months (range 12-254 months) in the GDD group. Thirty-four per cent (11/32 eyes) undergoing CPC later required further treatment at a mean of 13.6±10.7 months with 10/11(91%) of additional interventions occurring within 2 years. Despite an initially high success rate for IOP control in the first 5 years, eventually 60% (9/15 eyes) that underwent a second tube required additional treatment at a mean of 73.4 months with only 2/9(22%) requiring this within the first 2 years. The risk of visual acuity worsening by 2 Snellen lines or more at 12 months was 5/14 for the GDD group (36%) and 4/23(17%) for the CPC group. CONCLUSIONS: After failure of an initial drainage implant to control IOP, a sequential tube had a high initial rate of success but a relatively high likelihood of long-term failure, generally after 6 years. Eyes that received CPC tended to fail earlier, often within the first year, but had relatively few late failures.


Asunto(s)
Cuerpo Ciliar/cirugía , Implantes de Drenaje de Glaucoma , Glaucoma/cirugía , Coagulación con Láser , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Preescolar , Femenino , Estudios de Seguimiento , Humanos , Lactante , Presión Intraocular/fisiología , Láseres de Semiconductores/uso terapéutico , Láseres de Estado Sólido/uso terapéutico , Masculino , Persona de Mediana Edad , Falla de Prótesis , Reoperación , Estudios Retrospectivos , Agudeza Visual/fisiología , Adulto Joven
18.
PLoS One ; 10(9): e0138054, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26394037

RESUMEN

To determine if sequential treatment with Bevacizumab (Avastin), a monoclonal, VEGF antibody that blocks angiogenesis; Saratin, a 12 kD polypeptide with anti-inflammatory and anti-thrombotic properties; and Ilomastat, a matrix metalloproteinase (MMP) inhibitor, prolongs bleb life following glaucoma filtration surgery (GFS) in a rabbit model. Thirty-two New Zealand White rabbits (eight rabbits per group) underwent GFS in the left eye. Group 1 received a perioperative injection of both Saratin and Bevacizumab, and later, subconjuctival injections of Ilomastat on days 8 and 15. Group 2 received only Saratin perioperatively, and also received Ilomastat injections on days 8 and 15. Group 3, the negative control, received a single perioperative injection of Balanced Saline Solution (BSS) along with post-operative BSS injections on days 8 and 15. Group 4, the positive control, received topical treatment with Mitomycin-C (MMC) at the time of surgery with no further treatment. Blebs were evaluated by an observer masked to treatment every third day. Histology was obtained on two eyes in each group on post-op day twelve as well as all eyes following bleb failure. Eyes in group 1 had a mean bleb survival time of 29 ± 2.7 days, whereas those in group 2 that received the experimental treatment without Bevacizumab had a mean survival time of 25.5 ± 2.7 days. An ANOVA test showed that the Saratin/Ilomastat/Bevacizumab group demonstrated a significant prolongation of bleb survival compared to the BSS control-mean survival time of 19.7 ±2.7 days-(p = 0.0252) and was not significantly different from the MMC positive control group (p = 0.4238)-mean survival time of 32.5 ± 3.3. From tissue histology at day 12, the four different groups showed marked differences in the cellularity and capsule fibrosis. The MMC eyes showed minimal cellularity, were avascular and had minimal fibrous tissue. BSS group showed high cellularity, moderate to high fibrosis, and thicker and more defined capsules than either of the treatment groups and the positive control. Both the Saratin/Ilomastat/Bevacizumab and Saratin/Ilomastat only eyes showed moderate cellularity with minimal fibrosis, with less cellularity and fibrosis present in the triple treatment group. Sequential therapy with multiple agents, including Bevacizumab, prolonged bleb function following GFS in the rabbit model and were significantly better than the negative BSS control. The experimental group did not show the same surface tissue histological thinning and side effects associated with MMC treatment.


Asunto(s)
Bevacizumab/farmacología , Vesícula/fisiopatología , Cirugía Filtrante/métodos , Glaucoma/terapia , Indoles/farmacología , Proteínas y Péptidos Salivales/farmacología , Análisis de Varianza , Inhibidores de la Angiogénesis/administración & dosificación , Inhibidores de la Angiogénesis/farmacología , Animales , Antibióticos Antineoplásicos/administración & dosificación , Antibióticos Antineoplásicos/farmacología , Bevacizumab/administración & dosificación , Terapia Combinada , Conjuntiva , Modelos Animales de Enfermedad , Quimioterapia Combinada , Glaucoma/fisiopatología , Ácidos Hidroxámicos , Indoles/administración & dosificación , Inyecciones , Mitomicina/administración & dosificación , Mitomicina/farmacología , Periodo Posoperatorio , Conejos , Proteínas y Péptidos Salivales/administración & dosificación , Factores de Tiempo , Resultado del Tratamiento , Cicatrización de Heridas/efectos de los fármacos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA