Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Shoulder Elbow Surg ; 33(4): 872-879, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37689103

RESUMEN

BACKGROUND: Current methods available for assessment of radiolucency and in-between fin (IBF) growth of a glenoid component have not undergone interobserver reliability testing for an all-polyethylene fluted central peg (FCP) glenoid. The purpose of this study was to evaluate anteroposterior radiographs of an FCP glenoid component at ≥48 months comparing commonly used scales to a new method adapted to the FCP. Our hypothesis was that the new method would result in acceptable intra- and interobserver agreement and a more accurate description of radiographic findings. METHODS: We reviewed ≥48-month follow-up radiographs of patients treated with a primary aTSA using an FCP glenoid. Eighty-three patients were included in the review. Radiographs were evaluated by 5 reviewers using novel IBF radiodensity and radiolucency assessments and the Wirth and Lazarus methods. To assess intraobserver reliability, a subset of 40 images was reviewed. Kappa statistics were calculated to determine intra- and interobserver reliability; correlations were assessed using Pearson correlation. RESULTS: Interobserver agreement (κ score) was as follows: IBF 0.71, radiolucency 0.68, Wirth 0.48, and Lazarus 0.22. Intraobserver agreement ranges were as follows: IBF radiodensity 0.36-0.67, radiolucency 0.55-0.62, Wirth 0.11-0.73, and Lazarus 0.04-0.46. Correlation analysis revealed the following: IBF to Wirth r = 0.93, radiolucency to Lazarus r = 0.92 (P value <.001 for all). CONCLUSION: This study introduces a radiographic assessment method developed specifically for an FCP glenoid component. Results show high interobserver and acceptable intraobserver reliability for the method presented in this study. The new scales provide a more accurate description of radiographic findings, helping to identify glenoid components that may be at risk for loosening.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Artroplastia de Reemplazo , Cavidad Glenoidea , Prótesis Articulares , Articulación del Hombro , Humanos , Polietileno , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Artroplastia de Reemplazo/métodos , Reproducibilidad de los Resultados , Estudios de Seguimiento , Resultado del Tratamiento , Diseño de Prótesis , Cavidad Glenoidea/diagnóstico por imagen , Cavidad Glenoidea/cirugía
2.
Artículo en Inglés | MEDLINE | ID: mdl-38537768

RESUMEN

BACKGROUND: Optimal glenosphere positioning in a lateralized reverse shoulder arthroplasty (RSA) to maximize functional outcomes has yet to be clearly defined. Center of rotation (COR) measurements have largely relied on anteroposterior radiographs, which allow assessment of lateralization and inferior position, but ignore scapular Y radiographs, which may provide an assessment of the posterior and inferior position relative to the acromion. The purpose of this study was to evaluate the COR in the sagittal plane and assess the effect of glenosphere positioning with functional outcomes using a 135° inlay stem with a lateralized glenoid. METHODS: A retrospective review was performed on a prospectively maintained multicenter database on patients who underwent primary RSA from 2015 to 2021 with a 135° inlay stem. The COR was measured on minimum 2-year postoperative sagittal plain radiographs using a best-fit circle fit method. A best-fit circle was made on the glenosphere and the center was marked. From there, 4 measurements were made: (1) center to the inner cortex of the coracoid, (2) center to the inner cortex of the anterior acromion, (3) center to the inner cortex of the middle acromion, and (4) center to the inner cortex of the posterior acromion. Regression analysis was performed to evaluate any association between the position of the COR relative to bony landmarks with functional outcomes. RESULTS: A total of 136 RSAs met the study criteria. There was no relation with any of the distances with outcome scores (American Shoulder and Elbow Surgeons Standardized Shoulder Assessment Form, visual analog scale). In regard to range of motion (ROM), each distance had an effect on at least 1 parameter. The COR to coracoid distance had the broadest association with ROM, with improvements in forward flexion (FF), external rotation (ER0), and internal rotation with the arm at 90° (IR90) (P < .001, P = .031, and P < .001, respectively). The COR to coracoid distance was also the only distance to affect the final FF and IR90. For every 1-mm increase in this distance, there was a 1.8° increase in FF and 1.5° increase in IR90 (ß = 1.78, 95% confidence interval [CI] 0.85-2.72, P < .001, and ß = 1.53, 95% CI 0.65-2.41, P < .001; respectively). CONCLUSION: Evaluation of the COR following RSA in the sagittal plane suggests that a posteroinferior glenosphere position may improve ROM when using a 135° inlay humeral component and a lateralized glenoid.

3.
J Shoulder Elbow Surg ; 33(6S): S1-S8, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38237722

RESUMEN

BACKGROUND: Glenoid-sided lateralization in reverse shoulder arthroplasty (RSA) decreases bony impingement and improves rotational range of motion, but has been theorized to increase the risk of acromial or scapular spine fractures (ASFs). The purpose of this study was to assess if glenoid-sided lateralization even up to 8 mm increases the risk for stress fracture following RSA with a 135° inlay humeral component. METHODS: A retrospective review was performed from a multicenter prospectively collected database on patients who underwent primary RSA from 2015 to 2021. All RSAs were performed with a 135° inlay humeral component. Varying amounts of glenoid lateralization were used from 0 to 8 mm. Preoperative radiographs were reviewed for the presence of acromial thinning, acromiohumeral distance (AHD), and inclination. Postoperative implant position (distalization, lateralization, and inclination) as well as the presence of ASF was evaluated on minimum 1-year postoperative radiographs. Regression analyses were performed on component and clinical variables to assess for factors predictive of ASF. RESULTS: Acromial or scapular spine fractures were identified in 26 of 470 shoulders (5.5%). Glenoid-sided lateralization was not associated with ASF risk (P = .890). Furthermore, the incidence of fracture did not vary based on glenoid-sided lateralization (0-2 mm, 7.4%; 4 mm, 5.6%; 6 mm, 4.4%; 8 mm, 6.0%; P > .05 for all comparisons). RSA on the dominant extremity was predictive of fracture (odds ratio [OR] 2.21, 95% confidence interval [CI] 1.20-5.75; P = .037), but there was no relationship between patient age, sex, preoperative acromial thinning, or diagnosis and risk of fracture. Although there was no difference in mean postoperative AHD between groups (P = .443), the pre- to postoperative delta AHD was higher in the stress fracture group (2.0 ± 0.7 cm vs. 1.7 ± 0.7 cm; P = .015). For every centimeter increase in delta AHD, there was a 121% increased risk for fracture (OR 2.21, 95% CI 1.33-3.68; P = .012). Additionally, for every 1-mm increase in inferior glenosphere overhang, there was a 19% increase in fracture risk (P = .025). CONCLUSION: Up to 8 mm of glenoid-sided metallic lateralization does not appear to increase the risk of ASF when combined with a 135° inlay humeral implant. Humeral distalization increases the risk of ASF, particularly when there is a larger change between pre- and postoperative AHD or higher inferior glenosphere overhang. In cases of pronounced preoperative superior humeral migration, it may be a consideration to avoid excessive postoperative distalization, but minimizing bony impingement via glenoid-sided lateralization appears to be safe.


Asunto(s)
Acromion , Artroplastía de Reemplazo de Hombro , Fracturas por Estrés , Humanos , Artroplastía de Reemplazo de Hombro/efectos adversos , Estudios Retrospectivos , Femenino , Masculino , Fracturas por Estrés/etiología , Fracturas por Estrés/diagnóstico por imagen , Anciano , Acromion/diagnóstico por imagen , Persona de Mediana Edad , Escápula/diagnóstico por imagen , Escápula/lesiones , Articulación del Hombro/cirugía , Articulación del Hombro/diagnóstico por imagen , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/epidemiología , Prótesis de Hombro/efectos adversos , Diseño de Prótesis
4.
J Shoulder Elbow Surg ; 32(6): 1222-1230, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36584872

RESUMEN

BACKGROUND: Anatomic total shoulder arthroplasty (aTSA) is a successful and reproducible treatment for patients with painful glenohumeral arthritis. However, long-term outcomes using traditional onlay glenoid components have been tempered by glenoid loosening. Inset components have been proposed to minimize glenoid loosening by reducing edge-loading and opposite-edge lift-off forces with humeral translation. Successful short- and long-term outcomes have been reported while using inset glenoid implants. The current study is the largest study presenting a minimum of 2-year follow-up data following aTSA with an all-polyethylene inset glenoid component (Shoulder Innovations, Holland, MI, USA). METHODS: A dual center, retrospective review of patients undergoing aTSA using an Inset glenoid component by 2 fellowship-trained shoulder surgeons at 2 separate institutions from August, 2016, to August, 2019, was performed. Minimum follow-up was 2 years. Range of motion (ROM), visual analog scale (VAS) pain scores, Single Assessment Numeric Evaluation (SANE), and American Shoulder and Elbow Surgeons (ASES) scores were obtained. Radiographic outcomes, including central peg lucency and glenoid loosening, were assessed by 3 independent reviewers on the postoperative Grashey and axillary radiographs obtained at the final follow-up. RESULTS: Seventy-five shoulders were included for the final analysis. The mean age of the entire cohort was 64 (±11.4) years. Twenty-one (28%) glenoids were type A1, 10 (13.3%) were type A2, 13 (17.3%) were type B1, 22 (29.3%) were type B2, 6 (8%) were type B3, and 3 (4%) were type D. At a minimum follow-up of 24 months (mean: 28.7 months), a significant improvement in ROM in all planes was observed. Significant improvements in VAS (5.1-0.9, P < .001), SANE (39.5-91.2, P < .001), and ASES (43.7-86.6, P < .001) scores were observed. There were 4 (5.3%) cases of central peg lucency about the inset glenoid component and one (1.3%) case of glenoid loosening. No revisions were performed for glenoid loosening. CONCLUSION: At a minimum of 2 years postoperatively, there were significant improvements in ROM, VAS, SANE, and ASES scores with very low rates of central peg lucency and glenoid loosening in patients undergoing aTSA with an inset glenoid component. Further work is needed to determine the long-term benefit of this novel implant.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Cavidad Glenoidea , Articulación del Hombro , Prótesis de Hombro , Humanos , Persona de Mediana Edad , Anciano , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Diseño de Prótesis , Escápula/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Estudios de Seguimiento , Rango del Movimiento Articular , Cavidad Glenoidea/cirugía
5.
J Shoulder Elbow Surg ; 32(2): 240-246, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36115615

RESUMEN

BACKGROUND: Restoring the native center of rotation (COR) in total shoulder arthroplasty (TSA) has been shown to improve postsurgical function, subjective outcomes, and implant longevity. The primary purpose of this study was to compare postoperative radiographic restoration of the humeral COR between short-stem and stemless humeral implants by evaluating the mean COR shift between the 2 techniques. Secondary outcomes evaluated were comparisons of COR shift outliers, humeral head implant thickness and diameter, direction of COR shift, and neck-shaft angle (NSA). METHODS: This study was a multicenter retrospective comparative study using a consecutive series of primary anatomic TSA patients who received either a short-stem or stemless humeral implant. Radiographically, COR and NSA were measured by 2 fellowship-trained surgeons using the best-fit circle technique on immediate postoperative Grashey radiographs. RESULTS: A total of 229 patients formed the final cohort for analysis that included 89 short stems and 140 stemless components. The mean COR shift for short stems was 2.7 mm (±1.4 mm) compared with 2.1 mm (±0.9 mm) for stemless implants (P < .001). The percentage of short-stem implant patients with a >2 mm COR difference from native was 66.0% (n = 62) compared with 47.4% (n = 64) for stemless (P = .006). The percentage of short-stem patients with a >4 mm COR difference from native was 17.0% (n = 16) compared with 3.0% (n = 4) for stemless (P < .001). The mean humeral implant head thickness for short stems was 18.7 ± 2.2 mm compared with 17.2 ± 1.3 mm for stemless implants (P < .001). The mean humeral head diameter for short stems was 48.7 ± 4.4 mm compared with 45.5 ± 3.5 mm for stemless implants (P < .001). The NSA for the short-stem cohort was 136.7° (±3.6°) compared with 133.5° (±6.0°) for stemless (P < .001). CONCLUSIONS: Stemless prostheses placed during TSA achieved improved restoration of humeral head COR and were less likely to have significant COR outliers compared with short-stem implants.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Osteoartritis , Articulación del Hombro , Prótesis de Hombro , Humanos , Cabeza Humeral/diagnóstico por imagen , Cabeza Humeral/cirugía , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Estudios Retrospectivos , Osteoartritis/cirugía , Diseño de Prótesis , Resultado del Tratamiento
6.
J Shoulder Elbow Surg ; 31(5): 963-970, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-34715281

RESUMEN

BACKGROUND: Although reverse total shoulder arthroplasty (RTSA) has excellent reported outcomes and satisfaction, patients often have postoperative limitations in range of motion (ROM), specifically internal rotation. Increased lateralization is thought to improve ROM following RTSA. The purpose of this study was to evaluate the association between radiographic measurements of lateralization and postoperative ROM and clinical outcome scores following RTSA. The authors hypothesized that increased radiographic lateralization would be associated with improved postoperative ROM, specifically internal rotation, but have no significant association with clinical outcome scores. METHODS: Patients who underwent RTSA with a 135° neck-shaft angle prosthesis and minimum 2-year clinical and radiographic follow-up were included and retrospectively reviewed. Postoperative radiographs were evaluated for several lateralization measurements including the lateralization shoulder angle (LSA), distance from the lateral border of the acromion to the lateral portion of the glenosphere, distance from the glenoid to the most lateral aspect of the greater tuberosity, and the distance from the lateral aspect of the acromion to the most lateral aspect of the greater tuberosity. Linear regression analyses were used to evaluate the independent association of each radiographic measurement of lateralization on forward flexion, external rotation, internal rotation, and the American Shoulder and Elbow Surgeons Standardized Shoulder Assessment Form (ASES) index score at 2 years postoperation. Receiver operating characteristic (ROC) curves were constructed to identify significant thresholds of each radiographic lateralization measurement. RESULTS: A total of 203 patients were included. For internal rotation, a greater LSA (P = .007), shorter acromion to glenosphere distance (meaning more glenoid lateralization) (P = .005), and a greater acromion to greater tuberosity distance (with the tuberosity more lateral to the acromion) (P = .021) were associated with improved internal rotation. Overall, ROC analysis demonstrated very little significant data, the most notable of which was the LSA, which had a significant cutoff of 82° (sensitivity 57%, specificity 68%, P = .012). CONCLUSION: Of the numerous radiographic measures of lateralization after RTSA, the LSA is the most significantly associated with outcomes, including improved internal rotation and a decrease in forward flexion and ASES score. The clinical significance of these statistically significant findings requires further study, as the observed associations were for very small changes that may not represent clinical significance.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Articulación del Hombro , Prótesis de Hombro , Artroplastía de Reemplazo de Hombro/efectos adversos , Humanos , Rango del Movimiento Articular , Estudios Retrospectivos , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Resultado del Tratamiento
7.
J Shoulder Elbow Surg ; 31(8): 1729-1737, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35151882

RESUMEN

BACKGROUND: Glenoid bone loss in anatomic total shoulder arthroplasty (aTSA) remains a controversial and challenging clinical problem. Previous studies have shown high rates of glenoid loosening for aTSA in shoulders with retroversion, posterior bone loss, and posterior humeral head subluxation. This study is the first to present minimum 2-year follow-up data of an all-polyethylene, biconvex augmented anatomic glenoid component for correction of glenoid retroversion and posterior humeral head subluxation. METHODS: This study is a multicenter, retrospective review of prospectively collected data on consecutive patients from 7 global clinical sites. All patients underwent aTSA using the biconvex posterior augmented glenoid (PAG). Inclusion criteria were preoperative computed tomographic (CT) scan, minimum 2 years since surgery, preoperative and minimum 2-year postoperative range of motion examination, and patient-reported outcome measures (PROMs). Glenoid classification, glenoid retroversion, and posterior humeral head subluxation were measured from preoperative CT and radiography and postoperative radiography. Statistical comparisons between pre- and postoperative values were performed with a paired t test. RESULTS: Eighty-six of 110 consecutive patients during the study period (78% follow-up) met the inclusion criteria and were included in our analysis. Mean follow-up was 35 ± 10 months, with a mean age of 68 ± 8 years (range 48-85). Range of motion statistically improved in all planes from pre- to postoperation. Mean visual analog scale score improved from 5.2 preoperation to 0.7 postoperation, Single Assessment Numeric Evaluation score from 43.2 to 89.5, Constant score from 41.8 to 76.9, and American Shoulder and Elbow Surgeons Standardized Shoulder Assessment Form score from 49.8 to 86.7 (all P < .0001). Mean glenoid retroversion improved from 19.3° to 7.4° (P < .0001). Posterior subluxation improved from 69.1% to 53.5% and posterior decentering improved from 5.8% to -3.0% (P < .0001). There was 1 patient with both a prosthetic joint infection and radiographic glenoid loosening that required revision. Seventy-nine of 86 patients had a Lazarus score of 0 (no radiolucency seen about peg or keel) at final follow-up. CONCLUSIONS: This study shows that at minimum 2-year follow-up, a posterior-augmented all-polyethylene glenoid can correct glenoid retroversion and posterior humeral head subluxation. Clinically, there was significant improvement in both range of motion and PROMs.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Cavidad Glenoidea , Luxaciones Articulares , Osteoartritis , Articulación del Hombro , Anciano , Anciano de 80 o más Años , Estudios de Seguimiento , Cavidad Glenoidea/diagnóstico por imagen , Cavidad Glenoidea/cirugía , Humanos , Luxaciones Articulares/cirugía , Persona de Mediana Edad , Osteoartritis/diagnóstico por imagen , Osteoartritis/cirugía , Polietileno , Rango del Movimiento Articular , Estudios Retrospectivos , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Resultado del Tratamiento
8.
J Shoulder Elbow Surg ; 29(11): 2200-2212, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32707325

RESUMEN

BACKGROUND: Total shoulder arthroplasty is an accepted treatment for glenohumeral osteoarthritis. The Arthrex Eclipse shoulder prosthesis is a stemless, canal-sparing humeral prosthesis with bone ingrowth capacity on the trunnion, as well as through the fenestrated hollow screw, that provides both diaphyseal and metaphyseal load sharing and fixation. METHODS: Between 2013 and 2018, 16 sites in the United States enrolled 327 patients (Eclipse in 237 and Arthrex Univers II in 90). All patients had glenohumeral arthritis refractory to nonsurgical care. Strict exclusion criteria were applied to avoid confounding factors such as severe patient comorbidities, arthritis not consistent with osteoarthritis, and medical or prior surgical treatments that may have affected outcomes. Patients were randomized to the Eclipse or Univers II group via block randomization. RESULTS: In total, 149 Eclipse and 76 Univers II patients reached 2-year follow-up (139 Eclipse patients [93.3%] and 68 Univers II patients [89.5%] had complete data). The success rate using the Composite Clinical Success score was 95% in the Eclipse group vs. 89.7% in the Univers II group. No patient exhibited radiographic evidence of substantial humeral radiolucency, humeral migration, or subsidence at any point. Reoperations were performed in 7 patients (3.2%) in the Eclipse group and 3 (3.8%) in the Univers II group. CONCLUSION: The Arthrex Eclipse shoulder prosthesis is a safe and effective humeral implant for patients with glenohumeral arthritis at 2-year follow-up, with no differences in outcomes compared with the Univers II shoulder prosthesis.


Asunto(s)
Tornillos Óseos , Osteoartritis/cirugía , Articulación del Hombro/cirugía , Prótesis de Hombro , Adulto , Anciano , Anciano de 80 o más Años , Artroplastía de Reemplazo de Hombro , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Estudios Prospectivos , Resultado del Tratamiento , Estados Unidos , Adulto Joven
9.
J Shoulder Elbow Surg ; 25(9): 1532-41, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-27068383

RESUMEN

BACKGROUND: The elliptical shape of the humeral head has been vaguely described, but a more detailed mathematical description is lacking. The primary goal of this study was to create formulae to describe the mathematical relationships between the various dimensions of anatomically shaped humeral heads. METHODS: Three-dimensional computer models of 79 proximal humeri derived from computed tomography scans (white subjects, 47 male and 32 female; ages, 17-87 years) were studied. Linear regression analysis of the obtained humeral measurements was performed, and Pearson correlation coefficient (R) values were calculated. To substantiate the results of the linear regression analysis, Welch t-test was used to compare various parameters of small, medium, and large humeral heads. RESULTS: Formulae for calculating humeral head height, diameters of the base of the humeral head in the frontal and sagittal planes, and radii of curvature in the frontal and sagittal planes were derived from the linear regression plots that were found to have strong (1 ≥ R ≥ 0.50) correlations. By Welch t-test, differences between the 3 head sizes were statistically significant in each case (P ≤ .022). The elliptical shape of the base of the humeral head was found to elongate with increasing humeral head size. CONCLUSIONS: Mathematical formulae relating various humeral head dimensional measurements are presented. The formulae derived in this study may be useful for the design of future prosthetic shoulder systems in which the goal is to replicate normal anatomy. This is the first study to describe that the elliptical shape of the base of the humeral head elongates as head size increases.


Asunto(s)
Simulación por Computador , Cabeza Humeral/anatomía & histología , Imagenología Tridimensional , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Antropometría , Femenino , Humanos , Modelos Lineales , Masculino , Persona de Mediana Edad , Tomografía Computarizada por Rayos X , Adulto Joven
10.
J Surg Orthop Adv ; 23(2): 83-9, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24875338

RESUMEN

The aim of this prospective cohort study was to investigate the effect of head and neck positioning on cerebral perfusion during shoulder arthroscopy in the beach chair position. Regional cerebral tissue oxygen saturation (rSO2) was monitored intraoperatively using near-infrared spectroscopy on 51 consecutive patients undergoing arthroscopic shoulder surgery in the beach chair position. The head of each subject was manipulated by the examiner and sequentially positioned for 45 seconds in terminal flexion, extension, bilateral rotation, and bilateral lateral bending. Decreases in rSO2 of 20% or greater from baseline were defined as a cerebral desaturation event (CDE). The association between head and neck position and cerebral perfusion was assessed. Eight percent of patients (4/51) experienced CDE during head and neck positioning. Body mass index was found to be a risk factor for CDE (p = .05). When comparing preoperative baseline rSO2 to intraoperative supine and intraoperative upright rSO2, there was no significant decrease in saturation levels for any of the six tested positions. Frequent intraoperative evaluations of the head and neck position as well as careful preoperative positioning may reduce the risk of position-related complications in patients undergoing elective shoulder arthroscopy in the beach chair position. In this study's patient population, however, head and neck position was not found to cause significant cerebral desaturation for the time period tested compared to preoperative baselines.


Asunto(s)
Circulación Cerebrovascular , Complicaciones Intraoperatorias/etiología , Posicionamiento del Paciente/efectos adversos , Articulación del Hombro/cirugía , Adolescente , Adulto , Anciano , Artroscopía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Adulto Joven
11.
JSES Int ; 8(4): 756-762, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39035644

RESUMEN

Background: Intramedullary nail fixation for proximal humerus fractures has been shown to provide satisfactory results. The quality of reduction correlates with clinical outcomes, the rate of complications, avascular necrosis, and postoperative loss of fixation. The purpose of this study was to evaluate the clinical outcomes and complications of 2-part proximal humerus fractures compared to 3- or 4-part proximal humerus fractures. Methods: A single-center retrospective review was carried out of patients who underwent an intramedullary nail for a proximal humerus fracture by one of three surgeons between the years of 2009 and 2022, and who had a minimum of 12-months follow-up. Fracture pattern, American Shoulder and Elbow Surgeons score, Single Assessment Numeric Evaluation score, satisfaction, pain score, range of motion, and complications were recorded. The mechanism of injury (high energy vs. low energy), method of reduction (open vs. percutaneous), and evidence of radiographic healing were assessed. A P value of <.05 was considered to be statistically significant. Results: The study included 78 patients (62 female, 16 male). The number of patients in each group (2-part, N = 32 vs. 3- or 4-part, N = 46), mean age (2-part, 64 vs. 3- or 4-part,61), follow-up (2-part, 42.5 months vs. 3- or 4-part, 34.5 months), injury type (2-part, 88% low energy vs. 3- or 4-part, 78% low energy), and method of reduction (2-part, 81% percutaneous vs. 3- or 4-part 72% percutaneous) were similar among the two groups. There was fracture union in all patients. All patients demonstrated satisfactory patient-reported outcome measures. However, 2-part fractures did have a significantly lower pain score, higher Single Assessment Numeric Evaluation score, and higher percentage of patients being satisfied or very satisfied when compared to 3- or 4-part fractures. The rate of subsequent procedures was 13% (n = 4) in 2-part fractures compared to 19% (n = 9) in 3- or 4-part fractures but was not statistically significant (P = .414). The overall rate of conversion to arthroplasty was 3.2% in 2-part fractures and 10.4% in 3- or 4-part fractures. Conclusion: Multipart proximal humerus fractures remain difficult to treat. However, this study demonstrates an overall acceptable outcome with improvement in range of motion, patient-reported outcomes, and similar complication rates between 2-part and 3- or 4-part proximal humerus fractures treated with an intramedullary nail. However, the improvement in certain parameters is not as marked in 3- or 4-part fractures as 2-part fractures.

12.
JSES Int ; 8(3): 528-534, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38707572

RESUMEN

Background: A proposed etiology of anterior shoulder pain and limited internal rotation after reverse shoulder arthroplasty (RSA) is impingement of the humeral component on the coracoid or conjoint tendon. The primary goal of this study was to investigate radiographic surrogates for potential coracoid or conjoint tendon impingement and their relationship to postoperative pain and internal rotation after RSA. Methods: A retrospective review of a clinical registry was performed to identify patients with (1) primary RSA, (2) minimum 2-year clinical follow-up, and (3) satisfactory postoperative axillary lateral radiographs. The primary radiographic measurement of interest was the subcoracoid distance (SCD), defined as the distance between the posterior aspect of the coracoid and the anterior glenosphere. Additional measurements were as follows: anterior glenosphere overhang, posterior glenosphere overhang, native glenoid width, lateralization of glenosphere relative to the coracoid tip, lateralization shoulder angle, and distalization shoulder angle. The primary clinical outcome of interest was the 2-year postoperative Visual Analog Scale score. Secondary outcomes were (1) internal rotation (IR) defined by spinal level (IRspine), (2) IR at 90 degrees of abduction, (3) American Shoulder and Elbow Surgeons score, (4) forward flexion, and (5) external rotation at 0 degrees of abduction. Linear regression analyses were used to evaluate the relationship of the various radiographic measures on the clinical outcomes of interest. Results: Two hundred seventeen patients were included. There was a statistically significant relationship between the SCD and Visual Analog Scale scores: B = -0.497, P = .047. There was a statistically significant relationship between the SCD and IRspine: B = -1.667, P < .001. Metallic lateralization was also positively associated with improving IRspine; increasing body mass index was negatively associated. There was a statistically significant relationship between the SCD and IR at 90 degrees of abduction: B = 5.844, P = .034. Conclusion: For RSA with a 135° neck shaft angle and lateralized glenoid, the postoperative SCD has a significant association with pain and IR. Decreasing SCD was associated with increased pain and decreased IR, indicating that coracoid or conjoint tendon impingement may be an important and potentially under-recognized etiology of pain and decreased IR following RSA. Further investigations aimed toward identifying a critical SCD to improve pain and IR may allow surgeons to preoperatively plan component position to improve clinical outcomes after RSA.

13.
JSES Int ; 8(3): 522-527, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38707585

RESUMEN

Background: Lateralization in reverse shoulder arthroplasty (RSA) decreases bony impingement and improves rotational range of motion, but has been theorized to increase the risk of subacromial notching (SaN). The purpose of this study was to evaluate the presence of SaN following RSA and its relationship with lateralization with a 135° inlay humeral component. The secondary purpose was to assess the association of SaN with functional outcomes. Methods: A retrospective review was performed from a multicenter prospectively collected database on patients who underwent primary RSA from 2015 to 2021. All RSAs were performed with a 135° inlay humeral component. SaN was defined as bony erosion with sclerotic margins on the undersurface of the acromion on final follow-up radiographs not present preoperatively. Postoperative implant positioning (inclination, distalization, and lateralization) were evaluated on minimum 1-year postoperative radiographs. Regression analyses were performed on implant and clinical variables to assess for risk factors. A separate analysis was performed to determine the association of SaN with clinical outcomes. Results: SaN was identified in 13 out of 442 shoulders (2.9%). Age, sex, body mass index, smoking status, diabetes mellitus, arm dominance had no relationship with SaN. Neither glenoid sided lateralization nor humeral offset were associated with SaN risk. Other implant characteristics such as distalization, glenosphere size, and postoperative inclination did not influence SaN risk. The presence of SaN did not affect patient-reported outcomes (American Shoulder and Elbow Surgeons: P = .357, Visual Analog Scale: P = .210) or range of motion. Conclusion: The rate of SaN is low and not associated with glenoid or humeral prosthetic lateralization when using a 135° inlay humeral component. When SaN occurs, it is not associated with functional outcomes or range of motion at short-term follow-up.

14.
JSES Int ; 8(1): 197-203, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38312271

RESUMEN

Background: Improvements in pain control after shoulder arthroplasty with a reduction in narcotic use continues to be an important postoperative goal. With the increased utilization of stemless anatomic total shoulder arthroplasty (aTSA), it is relevant to compare between stemmed and stemless arthroplasty to assess if there is any association between this implant design change and early postoperative pain. Methods: Patients from a multicenter, prospectively-maintained database who had undergone a stemless aTSA with a minimum of two year clinical follow-up were retrospectively identified. Patients who underwent aTSA with a short stem were identified in the same registry, and matched to the stemless aTSA patients by age, sex and preoperative pain score. The primary study outcome was the Visual Analog Scale pain score. Secondary pain outcomes were the American Shoulder and Elbow Surgeons shoulder pain subscore, Western Ontario Osteoarthritis of the Shoulder physical symptoms subscore, and the Single Assessment Numeric Evaluation score. Finally, the percentage of patients who could sleep on the affected shoulder was assessed for each group. These pain-related clinical outcomes were assessed and compared preoperatively, and postoperatively at 9 weeks, 26 weeks, one year and two years. For all statistical comparisons, P > .05 was considered significant. Results: 124 patients were included in the study; 62 in each group. At 9 weeks after surgery, statistically significantly improved pain control was reported by patients undergoing stemless aTSA, as assessed by the Visual Analog Scale (stemless: 1.5, stemmed: 2.5, P = .001), American Shoulder and Elbow Surgeons pain subscore (stemless: 42.4, stemmed: 37.3, P < .001), Western Ontario Osteoarthritis of the Shoulder Physical Symptoms (stemless: 80.3, stemmed: 73.1, P = .006) and Single Assessment Numeric Evaluation (stemless: 58.1, stemmed: 47.4, P = .011). Patients who underwent a stemless aTSA were significantly more likely to be able to sleep on the affected shoulder at 9 weeks (29% vs. 11%, odds ratio 3.2, 95% confidence interval 1.2-8.4, P = .014). By 26 weeks postoperatively, there were no differences in all pain-specific outcomes. At two years postoperatively, patient-reported outcomes, range of motion, and strength measures were all similar between the two cohorts. Conclusion: Stemless aTSA provides earlier improvement in postoperative shoulder pain compared to matched patients undergoing short-stem aTSA. Additionally, earlier return to sleeping on the affected shoulder was reported in the stemless aTSA group. The majority of these differences dissipate by 26 weeks postoperatively and there were no differences in pain, patient-reported outcomes, range of motion or strength measures between stemless and short-stem aTSA at 2 years postoperatively.

15.
Clin Orthop Relat Res ; 471(12): 4027-34, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23604602

RESUMEN

BACKGROUND: Patients undergoing arthroscopic shoulder surgery in the beach chair position may be at increased risk for serious neurocognitive complications as a result of cerebral ischemia. QUESTIONS/PURPOSES: We sought to define the (1) incidence; (2) timing; and (3) magnitude of intraoperative cerebral desaturation events (CDEs) in subjects undergoing arthroscopic shoulder surgery in the beach chair position, as well as whether (4) the length of surgery was an independent risk factor for intraoperative CDEs. METHODS: Regional cerebral tissue oxygen saturation (rSO2) was monitored intraoperatively using near-infrared spectroscopy on 51 consecutive patients undergoing arthroscopic shoulder surgery in the beach chair position. Intraoperative decreases in rSO2 of 20% or greater were defined as CDEs. RESULTS: The incidence of intraoperative CDEs in our series was 18% (nine of 51). Among the patients demonstrating CDE (n = 9), the mean time to onset of initial CDE was 18 minutes 38 seconds postinduction. Of those experiencing CDEs, the mean maximal decrease in rSO2 was 32% from preoperative baseline per patient. Additionally, the mean number of separate CDE instances was 1.89 in this patient population with an average duration of 3 minutes 3 seconds per instance. There was no statistically significant difference (p = 0.202) between patients demonstrating CDEs and those without in regard to length of surgery (95 versus 88 minutes). CONCLUSIONS: The degree and duration of cerebral ischemia required to produce neurocognitive dysfunction in this patient population remains undefined; however, cerebral oximetry with near-infrared spectroscopy allows prompt identification and treatment of decreased cerebral perfusion. We believe protocols aimed at detecting and reversing CDE may improve patient safety.


Asunto(s)
Artroscopía/efectos adversos , Isquemia Encefálica/etiología , Trastornos del Conocimiento/etiología , Articulación del Hombro/cirugía , Adulto , Anciano , Artroscopía/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Oximetría , Posicionamiento del Paciente , Postura , Estudios Prospectivos
16.
J Shoulder Elbow Surg ; 22(9): 1228-35, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23415820

RESUMEN

BACKGROUND: Patients undergoing shoulder surgery in the beach chair position may be at increased risk for serious neurocognitive complications due to cerebral ischemia. We sought to define the incidence, patient risk factors, and clinical sequelae of intraoperative cerebral desaturation events. METHODS: Regional cerebral tissue oxygen saturation (rSO2) was monitored intra-operatively using near-infrared spectroscopy (NIRS) on 50 consecutive patients. The Repeatable Battery for the Assessment of Neuropsychological Status (RBANS) was administered to each patient pre- and postoperatively. Intra-operative decreases in rSO2 of 20% or greater were defined as cerebral desaturation events (CDE). The association between intraoperative CDE and postoperative cognitive decline was assessed. RESULTS: The incidence of intraoperative CDE in our series was 18% (9/50). Increased body mass index (BMI) was found to have a statistically significant association with intraoperative CDE (mean BMI 37.32 vs 28.59, P < .0001). There was no statistical significance in pre- vs postoperative RBANS either in composite scores or any of the sub-indices in either group. CONCLUSION: The degree and duration of cerebral ischemia required to produce neurocognitive dysfunction in this patient population remains undefined; however, cerebral oximetry with NIRS allows prompt identification and treatment of decreased cerebral perfusion decreasing the risk of this event. Increased BMI was found to be a statistically significant patient risk factor for the development of intra-operative CDE. The transient intra-operative CDEs were not associated with postoperative cognitive dysfunction in our patient series. We believe protocols aimed at detecting and reversing CDE minimize the risk of neurocognitive dysfunction and improve patient safety.


Asunto(s)
Artroscopía/efectos adversos , Isquemia Encefálica/epidemiología , Trastornos del Conocimiento/epidemiología , Complicaciones Intraoperatorias , Posicionamiento del Paciente , Articulación del Hombro , Adulto , Anciano , Isquemia Encefálica/diagnóstico , Isquemia Encefálica/psicología , Trastornos del Conocimiento/diagnóstico , Estudios de Cohortes , Femenino , Humanos , Incidencia , Artropatías/cirugía , Masculino , Persona de Mediana Edad , Monitoreo Intraoperatorio , Pruebas Neuropsicológicas , Factores de Riesgo , Espectroscopía Infrarroja Corta
17.
J Am Acad Orthop Surg ; 20(11): 704-14, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23118136

RESUMEN

Degenerative joint disease following trauma to the elbow is difficult to manage in any patient. However, this condition becomes substantially more challenging in the young, active population. Increased activity demands and limited functional capacity of total elbow arthroplasty mean that joint arthroplasty should be regarded as a salvage procedure. The primary goal of treatment is to restore a pain-free or minimally painful functional joint while preserving future surgical options. This requires accurate assessment of the primary patient complaint, be it terminal pain and stiffness or pain along the entire arc of motion. Patients who report stiffness and pain at terminal motion may benefit from arthroscopic or open osteocapsular débridement. Those with advanced degenerative changes and pain throughout the entire arc of motion may require joint resurfacing with interposition arthroplasty, partial joint arthroplasty, or total joint arthroplasty.


Asunto(s)
Lesiones de Codo , Articulación del Codo , Osteoartritis/cirugía , Algoritmos , Artrodesis , Artroplastia/métodos , Artroplastia de Reemplazo de Codo , Artroscopía , Desbridamiento , Articulación del Codo/diagnóstico por imagen , Articulación del Codo/fisiopatología , Articulación del Codo/cirugía , Humanos , Cuerpos Libres Articulares/cirugía , Osteoartritis/diagnóstico por imagen , Osteoartritis/fisiopatología , Examen Físico , Radio (Anatomía)/cirugía , Rango del Movimiento Articular , Tomografía Computarizada por Rayos X , Adulto Joven
18.
J Am Acad Orthop Surg ; 20(9): 604-13, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22941803

RESUMEN

Glenohumeral osteoarthritis is the most common reason for shoulder replacement. Total shoulder arthroplasty provides reliable pain relief and restoration of function, with implant survivorship reported at 85% at 15 years. Glenoid component wear and aseptic loosening are among the most common reasons for revision. Glenoid wear characteristics have been correlated with, among other things, the degree of anatomic glenoid version correction. Anatomic glenoid reconstruction is particularly challenging in the presence of glenoid bone deficiency. Walch classified glenoid morphology into five types: type A, centered, without posterior subluxation but with minor erosion (A1) or major erosion (A2); type B, posteriorly subluxated (B1) or posteriorly subluxated with posterior glenoid erosion (B2); and type C, excessive glenoid retroversion. The type A glenoid represents only 59% of patients; thus, the need to address glenoid deformity is common. Methods of correction include asymmetric reaming of the anterior glenoid, bone grafting of the posterior glenoid, and implanting a specialized glenoid component with posterior augmentation. In many cases of type C or hypoplastic glenoid, the humerus is concentrically reduced in the deficient glenoid and glenoid deformity may not need to be corrected. Severely hypoplastic glenoid may require the use of bone-sparing glenoid components or reverse total shoulder arthroplasty.


Asunto(s)
Artroplastia de Reemplazo , Cavidad Glenoidea/patología , Osteoartritis/patología , Osteoartritis/cirugía , Articulación del Hombro/cirugía , Fenómenos Biomecánicos , Trasplante Óseo , Humanos , Inestabilidad de la Articulación/cirugía , Osteoartritis/fisiopatología , Procedimientos de Cirugía Plástica , Articulación del Hombro/patología , Articulación del Hombro/fisiopatología , Resultado del Tratamiento
19.
J Clin Med ; 11(13)2022 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-35807048

RESUMEN

The purpose of this study was to compare the short-term clinical and radiographic outcomes of a lateralized glenoid construct with either a central screw or post. Methods: A multicenter retrospective study was conducted of reverse shoulder arthroplasties (RSAs) with minimum 2-year clinical followup. All RSAs implanted had a 135° neck shaft angle (NSA) and a modular circular baseplate. The patients were divided into two cohorts based on the type of central fixation for their glenoid baseplates (central post (CP) vs. central screw (CS)). The clinical outcomes, rates of revisions, and available radiographs were evaluated. Results: In total, 212 patients met the study criteria. Postoperatively, both groups improved over their preoperative baseline. There were no significant differences between the cohorts in any PROs at 2 years postoperatively. No findings of gross loosening were identified in either cohort. Implant survival was 98.6% at 2 years. Conclusions: When using a lateralized glenoid implant with a 135° NSA inlay humeral component, both central post and central screw baseplate fixation provide good clinical outcomes, survivorship, and improvements in ROM at 2 years. There is no difference in loosening or revision rates between the types of baseplate fixation at a minimum of 2 years postoperatively.

20.
JSES Int ; 6(6): 923-928, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36353412

RESUMEN

Background: In performing reverse total shoulder arthroplasty (rTSA), the role of repairing the subscapularis has been debated. Our objective was to determine the effect of subscapularis repair following rTSA on postoperative shoulder ranges of motion and patient reported outcome scores (PROs). Methods: A prospective registry was reviewed to establish a cohort of primary rTSA patients with a 135-degree humeral implant, with a minimum of 2 years of follow-up. Variables collected included demographics, subscapularis repair information, diagnosis, glenosphere size, and glenoid lateralization information. Outcomes collected were range of motion measurements, subscapularis strength, and multiple generic and shoulder PROs. Multivariable linear regression models were created to predict these 2-year outcomes. Results: The 143-patient cohort had a mean age of 69 years with 68% of patients undergoing subscapularis repair. After adjustment in the multivariable models, whether the subscapularis was repaired did not significantly predict a 2-year forward elevation, external rotation, internal rotation, subscapularis strength, Western Ontario Osteoarthritis of the Shoulder score, VR-12 scores, Constant Score, or American Shoulder and Elbow Surgeons Shoulder Scores. Increased glenoid lateralization significantly predicted greater internal rotation, higher VR-12 physical score, and higher Constant Score. There were no dislocations in either group. Conclusions: After adjusting for patient and implant factors, subscapularis repair was not associated with a 2-year postoperative range of motion, strength, or any PROs suggesting that repairing the subscapularis may not affect functional outcome. Increased glenoid lateralization through the baseplate and glenosphere independently predicted better internal rotation, VR-12 physical score, and Constant Scores indicating a benefit to lateralization during rTSA.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA