Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 71
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Rev Sci Instrum ; 94(1): 013101, 2023 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-36725595

RESUMEN

Two extended x-ray absorption fine structure flat crystal x-ray spectrometers (EFX's) were designed and built for high-resolution x-ray spectroscopy over a large energy range with flexible, on-shot energy dispersion calibration capabilities. The EFX uses a flat silicon [111] crystal in the reflection geometry as the energy dispersive optic covering the energy range of 6.3-11.4 keV and achieving a spectral resolution of 4.5 eV with a source size of 50 µm at 7.2 keV. A shot-to-shot configurable calibration filter pack and Bayesian inference routine were used to constrain the energy dispersion relation to within ±3 eV. The EFX was primarily designed for x-ray absorption fine structure (XAFS) spectroscopy and provides significant improvement to the Laboratory for Laser Energetics' OMEGA-60 XAFS experimental platform. The EFX is capable of performing extended XAFS measurements of multiple absorption edges simultaneously on metal alloys and x-ray absorption near-edge spectroscopy to measure the electron structure of compressed 3d transition metals.

2.
Artículo en Inglés | MEDLINE | ID: mdl-31093030

RESUMEN

The properties of hot, dense plasmas generated by the irradiation of GaAs targets by the Titan laser at Lawrence Livermore National Laboratory were determined by the analysis of high resolution K shell spectra in the 9 keV to 11 keV range. The laser parameters, such as relatively long pulse duration and large focal spot, were chosen to produce a steady-state plasma with minimal edge gradients, and the time-integrated spectra were compared to non-LTE steady state spectrum simulations using the FLYCHK and NOMAD codes. The bulk plasma streaming velocity was measured from the energy shifts of the Ga He-like transitions and Li-like dielectronic satellites. The electron density and the electron energy distribution, both the thermal and the hot non-thermal components, were determined from the spectral line ratios. After accounting for the spectral line broadening contributions, the plasma turbulent motion was measured from the residual line widths. The ionization balance was determined from the ratios of the He-like through F-like spectral features. The detailed comparison of the experimental Ga spectrum and the spectrum simulated by the FLYCHK code indicates two significant discrepancies, the transition energy of a Li-like dielectronic satellite (designated t) and the calculated intensity of a He-like line (x), that should lead to improvements in the kinetics codes used to simulate the X-ray spectra from highly-charged ions.

3.
J Clin Invest ; 48(12): 2330-40, 1969 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-5355344

RESUMEN

Fractional reabsorption of water, sodium, and potassium at proximal and distal tubular sites within the nephron was studied by recollection-micropuncture experiments on dogs undergoing hypertonic mannitol diuresis. After an initial control hydropenic phase, 16% mannitol in modified Ringer's solution was administered intravenously, resulting in marked increases in fractional excretion of water (28.7%), sodium (12.6%), and potassium (63.9%). Inulin clearance decreased significantly from 35.1 to 25.2 ml/min. Analysis of paired micropuncture data revealed a significant decrease in tubule fluid to plasma (TF:P) inulin ratios in both the proximal tubule (1.63-1.45) and distal tubule (5.38-1.94). There was also a significant decrease in proximal TF:P sodium ratios (0.99-0.93) and potassium ratios (1.05-0.98). Distal TF:P sodium ratios, in contrast, rose significantly (0.38-0.59), while TF:P potassium ratios tended towards unity whether initially greater or less than one. Fractional reabsorption of sodium and water decreased by 5% and 10% respectively in the proximal tubule, but to a lesser extent than the resulting increases in fractional urinary excretion. The nonreabsorbed fraction, however, had increased sharply at the point of distal puncture for water (32%), sodium (26%), and potassium (26%), indicating a large inhibitory effect within the loop of Henle in addition to the smaller proximal effects.


Asunto(s)
Diuresis/efectos de los fármacos , Túbulos Renales/fisiología , Manitol/farmacología , Animales , Perros , Tasa de Filtración Glomerular , Soluciones Hipertónicas , Inulina/sangre , Inulina/metabolismo , Tasa de Depuración Metabólica , Potasio/sangre , Potasio/orina , Sodio/sangre , Sodio/orina , Agua/metabolismo , Equilibrio Hidroelectrolítico
4.
Rev Sci Instrum ; 87(11): 11E305, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27910617

RESUMEN

A Cauchois transmission-crystal spectrometer has been developed with high crystal resolving power in the 6 keV-15 keV energy range and sufficient sensitivity to record single-shot spectra from the Lawrence Livermore National Laboratory (LLNL) Titan laser and other comparable or more energetic lasers. The spectrometer capabilities were tested by recording the W L transitions from a laboratory source and the extended x-ray absorption fine structure (EXAFS) spectrum through a Cu foil.

5.
Artículo en Inglés | MEDLINE | ID: mdl-31093029

RESUMEN

Experiments were performed at the LLNL Titan laser to measure the propagation direction of the energetic electrons that were generated during the interaction of the polarized laser beam with solid targets in the case of normal incidence. The energetic electrons propagated through vacuum to spectator metal wires in the polarization direction and in the perpendicular direction, and the K shell spectra from the different wire materials were recorded as functions of the distance from the laser focal spot. It was found that the fluence of the energetic electrons driven into the spectator wires in the polarization direction compared to the perpendicular direction was larger and increased with the distance from the focal spot. This indicates that energetic electrons are preferentially driven in the direction of the intense oscillating electric field of the incident laser beam in agreement with the multiphoton inverse Bremsstrahlung absorption process.

6.
Arch Intern Med ; 145(1): 87-9, 1985 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-3882071

RESUMEN

In a prospective, controlled study undertaken to assess renal function following infusion of radiologic contrast material, serum creatinine level was determined before scan and for three days after scan in 193 patients undergoing computed tomographic (CT) brain scan with contrast enhancement (contrast medium volume, 60 to 350 mL) and in 233 controls undergoing CT scan without infusion. Renal failure developed in four patients who had infusion of contrast material and in three patients who had no infusion (greater than or equal to 50% increase in serum creatinine level and above normal). In the high-risk group (serum creatinine level greater than or equal to 1.5 mg/dL or diabetes mellitus), renal failure developed in none of the 19 patients infused and in two of 46 in the noninfused group. It was concluded that previous uncontrolled studies may have overestimated the risk of renal failure induced by contrast material.


Asunto(s)
Lesión Renal Aguda/etiología , Medios de Contraste/efectos adversos , Adulto , Anciano , Ensayos Clínicos como Asunto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Riesgo , Tomografía Computarizada por Rayos X
7.
Transplantation ; 39(6): 610-5, 1985 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-3890290

RESUMEN

To establish the impact of transplantation on the course of chronic hepatitis B liver disease we performed a prospective study of the clinical and pathological sequelae of hepatitis B disease in all 22 patients who had renal allografts that functioned for more than 1 year and who were hepatitis B surface antigen (HBsAg)-positive following transplantation. No patient converted to HBsAg-negative. During a mean follow-up of 83 months serial liver biopsies were performed in 20 patients and 1 liver biopsy was available in the remaining 2 patients. Eleven patients died of liver disease, 5 of whom died of hepatic failure, 3 with hepatoma, 2 of gastrointestinal hemorrhage, and 1 of ascites with pleuroperitoneal fistula. Aggressive liver disease was observed in the vast majority of patients: 12 ultimately developed cirrhosis, (mean follow-up 81 months), 6 chronic active hepatitis (mean follow-up 93 months), 3 chronic persistent hepatitis (mean follow-up 89 months), and in 1 patient the presence of HB virus in hepatocytes was the sole morphologic alteration (follow-up 42 months). There was a marked tendency to progression in that 82% of patients with virus only, reactive hepatitis, or chronic persistent hepatitis on initial biopsy subsequently developed chronic active hepatitis or cirrhosis. For comparison, 10 HBsAg-positive patients whose renal failure had been treated by hemodialysis were also studied over a comparable period. Four patients converted to the negative state. Biochemical evidence of persistent liver dysfunction occurred in only 1 patient and no patient has died from complications of liver disease. We conclude that in the immunosuppressed renal transplant patient HB infection often results in the development of cirrhosis, leading to death from hepatoma and hepatic failure. This course is worse than that in dialysis patients. Renal transplantation of HBsAg-positive patients with end-stage renal failure may be inadvisable.


Asunto(s)
Hepatitis B/complicaciones , Trasplante de Riñón , Aspartato Aminotransferasas/sangre , Biopsia , Hepatitis B/patología , Hepatitis B/fisiopatología , Hepatitis Crónica/etiología , Hepatitis Crónica/patología , Humanos , Cirrosis Hepática/etiología , Diálisis Renal , Factores de Tiempo
8.
Med Phys ; 25(10): 2027-36, 1998 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-9800712

RESUMEN

A pulsed, portable hard x-ray source has been developed for medical imaging and flash x-ray absorptiometry. The source is powered by a Marx generator that drives a field emission x-ray tube which produces a 30-300 keV x-ray pulse of 100 ns duration. The x-ray fluence has dual-energy properties. The x-ray energy is relatively high early in the pulse and lower later in the pulse. The feasibility of using a single x-ray pulse for precision bone densitometry was analyzed. A computer simulation model was developed for the x-ray source, the filtration that enhances the dual-energy distribution, the absorption of the energy distribution by bone mineral and soft tissue, and the dual-energy detection system. It is feasible to determine the bone mineral density (BMD) of axial sites such as the lumbar spine and proximal femur with 2% precision over an area that is 15-20 mm in size, depending on the bone mineral and soft tissue thicknesses. An algorithm for determining the absolute BMD, to an accuracy of 2%, using a Plexiglas/TiO2 calibration phantom is discussed. At a distance of 50 cm from the source, the patient exposure is 3.7 mR. The average absorbed bone and tissue doses are 0.6 and 4.3 mrem, respectively. Factors that facilitate diagnostic measurements in clinical settings are the short patient observation time and the portability of the x-ray source.


Asunto(s)
Absorciometría de Fotón/métodos , Absorciometría de Fotón/instrumentación , Absorciometría de Fotón/estadística & datos numéricos , Algoritmos , Fenómenos Biofísicos , Biofisica , Densidad Ósea , Simulación por Computador , Humanos , Modelos Teóricos , Fantasmas de Imagen , Rayos X
9.
Rev Sci Instrum ; 85(11): 11D618, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25430194

RESUMEN

A high resolution crystal spectrometer utilizing a crystal in transmission geometry has been developed and experimentally optimized to measure the widths of emission lines in the 10-60 keV energy range with eV accuracy. The spectrometer achieves high spectral resolution by utilizing crystal planes with small lattice spacings (down to 2d = 0.099 nm), a large crystal bending radius and Rowland circle diameter (965 mm), and an image plate detector with high spatial resolution (60 µm in the case of the Fuji TR image plate). High resolution W L-shell and K-shell laboratory test spectra in the 10-60 keV range and Ho K-shell spectra near 47 keV recorded at the LLNL Titan laser facility are presented. The Ho K-shell spectra are the highest resolution hard x-ray spectra recorded from a solid target irradiated by a high-intensity laser.

10.
Rev Sci Instrum ; 83(4): 043104, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22559512

RESUMEN

In the pursuit of novel, laser-produced x-ray sources for medical imaging applications, appropriate instrumental diagnostics need to be developed concurrently. A type of transmission crystal spectroscopy has previously been demonstrated as a survey tool for sources produced by high-power and high-energy lasers. The present work demonstrates the extension of this method into the study of medium-intensity laser driven hard x-ray sources with a design that preserves resolving power while maintaining high sensitivity. Specifically, spectroscopic measurements of characteristic Kα and Kß emissions were studied from Mo targets irradiated by a 100 fs, 200 mJ, Ti: sapphire laser with intensity of 10(17) W/cm(2) to 10(18) W∕cm(2) per shot. Using a transmission curved crystal spectrometer and off-Rowland circle imaging, resolving powers (E/ΔE) of around 300 for Mo Kα(2) at 17.37 keV were obtained with an end-to-end spectrometer efficiency of (1.13 ± 0.10) × 10(-5). This sensitivity is sufficient for registering x-ray lines with high signal to background from targets following irradiation by a single laser pulse, demonstrating the utility of this method in the study of the development of medium-intensity laser driven x-ray sources.

11.
Rev Sci Instrum ; 83(10): 10E110, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23126932

RESUMEN

Close to an x-ray filter's K-edge the transmission depends strongly on the photon energy. For a few atom pairs, the K-edge of one is only a few tens of eV higher than a K-line energy of another, so that a small change in the line's energy becomes a measurable change in intensity behind such a matching filter. Lutetium's K-edge is ≃27 eV above iridium's Kα(2) line, ≃63.287 keV for cold Ir. A Lu filter reduces this line's intensity by ≃10 % when it is emitted by a plasma, indicating an ionization shift Δε≃10±1 eV.

12.
Rev Sci Instrum ; 81(10): 10E301, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21034000

RESUMEN

The transmission crystal spectrometer (TCS) is approved for taking data at the OMEGA-EP laser facility since 2009 and will be available for the OMEGA target chamber in 2010. TCS utilizes a Cauchois type cylindrically bent transmission crystal geometry with a source to crystal distance of 600 mm. Spectral images are recorded by image plates in four positions, one IP on the Rowland circle and three others at 200, 400, and 600 mm beyond the Rowland circle. An earlier version of TCS was used at LULI on experiments that determined the x-ray source size from spectral line broadening on one IP positioned behind the Rowland circle. TCS has recorded numerous backlighter spectra at EP for point projection radiography and for source size measurements. Hard x-ray source size can be determined from the source broadening of both K shell emission lines and from K absorption edges in the bremsstrahlung continuum, the latter being a new way to measure the spatial extent of the hard x-ray bremsstrahlung continuum.

13.
Rev Sci Instrum ; 81(10): 10E311, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21034010

RESUMEN

The potential of an x-ray magnifier prepared from a pair of asymmetrically cut crystals is studied to explore high energy x-ray imaging capabilities at high intensity laser facilities. OMEGA-EP and NIF when irradiating mid and high Z targets can be a source of high-energy x-rays whose production mechanisms and use as backlighters are a subject of active research. This paper studies the properties and potential of existing asymmetric cut crystal pairs from the National Institute of Standards and Technology (NIST) built in a new enclosure for imaging x-ray sources. The technique of the x-ray magnifier has been described previously. This new approach is aimed to find a design that could be used at laser facilities by magnifying the x-ray source into a screen far away from the target chamber center, with fixed magnification defined by the crystals' lattice spacing and the asymmetry angles. The magnified image is monochromatic and the imaging wavelength is set by crystal asymmetry and incidence angles. First laboratory results are presented and discussed.

14.
Rev Sci Instrum ; 81(10): 10E320, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21034018

RESUMEN

The dual crystal spectrometer (DCS) is an approved diagnostic at the OMEGA and the OMEGA-EP laser facilities for the measurement of high energy x-rays in the 11-90 keV energy range, e.g., for verification of the x-ray spectrum of backlighter targets of point projection radiography experiments. DCS has two cylindrically bent transmission crystal channels with image plate detectors at distances behind the crystals close to the size of the respective Rowland circle diameters taking advantage of the focusing effect of the cylindrically bent geometry. DCS, with a source to crystal distance of 1.2 m, provides the required energy dispersion for simultaneous detection of x-rays in a low energy channel (11-45 keV) and a high-energy channel (19-90 keV). A scaling study is described for varied pulse length with unchanged laser conditions (energy, focusing). The study shows that the Kα line intensity is not strongly dependent on the length of the laser pulse.

15.
Rev Sci Instrum ; 81(10): 10E302, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21034001

RESUMEN

The plasma-filled rod-pinch diode (PFRP) is an intense source of x-rays ideal for radiography of dense objects. In the PRFP megavoltage electrons from a pulsed discharge concentrate at the pointed end of a 1 mm diameter tapered tungsten rod. Ionization of this plasma might increase the energy of tungsten's Kα(1) fluorescence line, at 59.3182 keV, enough for the difference to be observed by a high-resolution Cauchois transmission crystal spectrograph. When the PFRP's intense hard bremsstrahlung is suppressed by the proper shielding, such an instrument gives excellent fluorescence spectra, albeit with as yet insufficient resolution to see any effect of tungsten's ionization. Higher resolution is possible with various straightforward upgrades that are feasible thanks to the radiation's high intensity.

18.
Appl Opt ; 45(8): 1680-7, 2006 Mar 10.
Artículo en Inglés | MEDLINE | ID: mdl-16572682

RESUMEN

Efficiency measurements of a grazing-incidence diffraction grating in the off-plane mount were performed using polarized synchrotron radiation. The grating had 5000 grooves/mm, an effective blaze angle of 14 degrees, and was gold coated. The efficiencies in the two polarization orientations (TM and TE) were measured in the 1.5-5.0 nm wavelength range and were compared with the efficiencies calculated using the PCGrate-SX code. The TM and TE efficiencies differ, offering the possibility of performing unique science studies of astrophysical, solar, and laboratory sources by exploiting the polarization sensitivity of the off-plane grating.

19.
J Trauma ; 59(6): 1463-8, 2005 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-16394923

RESUMEN

BACKGROUND: The purpose of this study was to record flash x-ray images of cavitation in human cadaver thighs caused by the passage of high-velocity bullets. The images are an initial step for understanding the cavitation process in human tissue and for implementing a better definition of extensive tissue injury. METHODS: Bullets were fired through the mid-thighs of 13 cadaver legs. The bullets were of two calibers, 7.62-mm full metal jacket boat tail with strike velocities in the range of 794 m/s to 880 m/s (10 thighs) and 5.70 mm full metal jacket with velocities in the range of 973 m/s to 992 m/s (3 thighs). Short duration (35 ns) x-ray images were recorded at various selected times after the bullets passed near the femurs. This study was carried out at the Armed Forces Institute of Pathology under approved human subject protocols. RESULTS: The cavity sizes and shapes were observed for the two types of bullets and at a number of times during the expansion and collapse of the cavities. As the bullets passed through the thighs, narrow cavities behind the bullets were observed. At later times, large expanded cavities were observed that encompassed the entire mid-thigh region. The observed cavities are at variance with those which were reported previously in gelatin tissue simulants. CONCLUSION: Flash x-ray radiography is an effective technique for the observation of internal cavitation in cadaver thighs caused by high-velocity bullets. These observations suggest that gelatin is not a proven simulant for human cadaver tissue in the study of cavitation subsequent to high-velocity missile impact.


Asunto(s)
Muslo/diagnóstico por imagen , Muslo/lesiones , Heridas por Arma de Fuego/diagnóstico por imagen , Cadáver , Fémur/diagnóstico por imagen , Fémur/lesiones , Fémur/patología , Humanos , Intensificación de Imagen Radiográfica , Traumatismos de los Tejidos Blandos/diagnóstico por imagen , Traumatismos de los Tejidos Blandos/patología , Muslo/patología , Heridas por Arma de Fuego/patología
20.
Phys Rev Lett ; 94(4): 045002, 2005 Feb 04.
Artículo en Inglés | MEDLINE | ID: mdl-15783564

RESUMEN

Absolutely calibrated, time-resolved spectral intensity measurements of soft-x-ray emission (hnu approximately 0.1-1.0 keV) from laser-irradiated polystyrene targets are compared to radiation-hydrodynamic simulations that include our new postprocessor, Virtual Spectro. This new capability allows a unified, detailed treatment of atomic physics and radiative transfer in nonlocal thermodynamic equilibrium conditions for simple spectra from low-Z materials as well as complex spectra from high-Z materials. The excellent agreement (within a factor of approximately 1.5) demonstrates the powerful predictive capability of the codes for the complex conditions in the ablating plasma. A comparison to data with high spectral resolution (E/deltaE approximately 1000) emphasizes the importance of including radiation coupling in the quantitative simulation of emission spectra.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA