Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
Mol Cell ; 57(6): 1011-1021, 2015 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-25728769

RESUMEN

Eosinophils are white blood cells that function in innate immunity and participate in the pathogenesis of various inflammatory and neoplastic disorders. Their secretory granules contain four cytotoxic proteins, including the eosinophil major basic protein (MBP-1). How MBP-1 toxicity is controlled within the eosinophil itself and activated upon extracellular release is unknown. Here we show how intragranular MBP-1 nanocrystals restrain toxicity, enabling its safe storage, and characterize them with an X-ray-free electron laser. Following eosinophil activation, MBP-1 toxicity is triggered by granule acidification, followed by extracellular aggregation, which mediates the damage to pathogens and host cells. Larger non-toxic amyloid plaques are also present in tissues of eosinophilic patients in a feedback mechanism that likely limits tissue damage under pathological conditions of MBP-1 oversecretion. Our results suggest that MBP-1 aggregation is important for innate immunity and immunopathology mediated by eosinophils and clarify how its polymorphic self-association pathways regulate toxicity intra- and extracellularly.


Asunto(s)
Proteínas de Unión al ADN/química , Proteínas de Unión al ADN/metabolismo , Eosinófilos/metabolismo , Animales , Muerte Celular/efectos de los fármacos , Línea Celular/efectos de los fármacos , Membrana Celular/efectos de los fármacos , Celulitis (Flemón)/metabolismo , Celulitis (Flemón)/patología , Proteínas de Unión al ADN/toxicidad , Dermatitis Atópica/metabolismo , Dermatitis Atópica/patología , Eosinofilia/metabolismo , Eosinofilia/patología , Células Epiteliales/efectos de los fármacos , Células Epiteliales/metabolismo , Escherichia coli/efectos de los fármacos , Interacciones Huésped-Patógeno , Humanos , Inmunidad Innata/fisiología , Ratones Endogámicos C57BL , Nanopartículas/metabolismo , Nanopartículas/toxicidad , Vesículas Secretoras/metabolismo , Piel/efectos de los fármacos , Piel/patología
2.
Nat Methods ; 11(5): 545-8, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24633409

RESUMEN

X-ray free-electron laser (XFEL) sources enable the use of crystallography to solve three-dimensional macromolecular structures under native conditions and without radiation damage. Results to date, however, have been limited by the challenge of deriving accurate Bragg intensities from a heterogeneous population of microcrystals, while at the same time modeling the X-ray spectrum and detector geometry. Here we present a computational approach designed to extract meaningful high-resolution signals from fewer diffraction measurements.


Asunto(s)
Rayos Láser , Sustancias Macromoleculares/química , Bacillus/enzimología , Calcio/química , Calibración , Simulación por Computador , Cristalización , Cristalografía por Rayos X , Electrones , Diseño de Equipo , Funciones de Verosimilitud , Modelos Químicos , Conformación Molecular , Muramidasa/química , Nanotecnología , Reproducibilidad de los Resultados , Programas Informáticos , Termolisina/química , Rayos X , Zinc/química
3.
Nat Methods ; 11(9): 923-6, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25108686

RESUMEN

We describe a method to measure ultrafast protein structural changes using time-resolved wide-angle X-ray scattering at an X-ray free-electron laser. We demonstrated this approach using multiphoton excitation of the Blastochloris viridis photosynthetic reaction center, observing an ultrafast global conformational change that arises within picoseconds and precedes the propagation of heat through the protein. This provides direct structural evidence for a 'protein quake': the hypothesis that proteins rapidly dissipate energy through quake-like structural motions.


Asunto(s)
Transferencia de Energía/efectos de la radiación , Rayos Láser , Ficobiliproteínas/efectos de la radiación , Ficobiliproteínas/ultraestructura , Dispersión del Ángulo Pequeño , Difracción de Rayos X/métodos , Ficobiliproteínas/química , Conformación Proteica/efectos de la radiación , Dosis de Radiación
4.
Nature ; 470(7332): 78-81, 2011 Feb 03.
Artículo en Inglés | MEDLINE | ID: mdl-21293374

RESUMEN

X-ray lasers offer new capabilities in understanding the structure of biological systems, complex materials and matter under extreme conditions. Very short and extremely bright, coherent X-ray pulses can be used to outrun key damage processes and obtain a single diffraction pattern from a large macromolecule, a virus or a cell before the sample explodes and turns into plasma. The continuous diffraction pattern of non-crystalline objects permits oversampling and direct phase retrieval. Here we show that high-quality diffraction data can be obtained with a single X-ray pulse from a non-crystalline biological sample, a single mimivirus particle, which was injected into the pulsed beam of a hard-X-ray free-electron laser, the Linac Coherent Light Source. Calculations indicate that the energy deposited into the virus by the pulse heated the particle to over 100,000 K after the pulse had left the sample. The reconstructed exit wavefront (image) yielded 32-nm full-period resolution in a single exposure and showed no measurable damage. The reconstruction indicates inhomogeneous arrangement of dense material inside the virion. We expect that significantly higher resolutions will be achieved in such experiments with shorter and brighter photon pulses focused to a smaller area. The resolution in such experiments can be further extended for samples available in multiple identical copies.


Asunto(s)
Mimiviridae/química , Difracción de Rayos X/instrumentación , Difracción de Rayos X/métodos , Electrones , Calor , Rayos Láser , Fotones , Factores de Tiempo , Rayos X
5.
J Synchrotron Radiat ; 22(3): 634-43, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25931079

RESUMEN

X-ray free-electron laser sources such as the Linac Coherent Light Source offer very exciting possibilities for unique research. However, beam time at such facilities is very limited and in high demand. This has led to significant efforts towards beam multiplexing of various forms. One such effort involves re-using the so-called spent beam that passes through the hole in an area detector after a weak interaction with a primary sample. This beam can be refocused into a secondary interaction region and used for a second, independent experiment operating in series. The beam profile of this refocused beam was characterized for a particular experimental geometry at the Coherent X-ray Imaging instrument at LCLS. A demonstration of this multiplexing capability was performed with two simultaneous serial femtosecond crystallography experiments, both yielding interpretable data of sufficient quality to produce electron density maps.

6.
J Synchrotron Radiat ; 22(3): 514-9, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25931062

RESUMEN

The Coherent X-ray Imaging (CXI) instrument specializes in hard X-ray, in-vacuum, high power density experiments in all areas of science. Two main sample chambers, one containing a 100 nm focus and one a 1 µm focus, are available, each with multiple diagnostics, sample injection, pump-probe and detector capabilities. The flexibility of CXI has enabled it to host a diverse range of experiments, from biological to extreme matter.


Asunto(s)
Cristalografía por Rayos X/instrumentación , Rayos Láser , Imagen Molecular/instrumentación , Aceleradores de Partículas/instrumentación , Espectrometría por Rayos X/instrumentación , Rayos X , California , Transferencia de Energía , Diseño de Equipo , Análisis de Falla de Equipo , Iluminación/instrumentación
7.
Phys Rev Lett ; 114(9): 098102, 2015 Mar 06.
Artículo en Inglés | MEDLINE | ID: mdl-25793853

RESUMEN

We present a proof-of-concept three-dimensional reconstruction of the giant mimivirus particle from experimentally measured diffraction patterns from an x-ray free-electron laser. Three-dimensional imaging requires the assembly of many two-dimensional patterns into an internally consistent Fourier volume. Since each particle is randomly oriented when exposed to the x-ray pulse, relative orientations have to be retrieved from the diffraction data alone. We achieve this with a modified version of the expand, maximize and compress algorithm and validate our result using new methods.


Asunto(s)
Imagenología Tridimensional/métodos , Mimiviridae/ultraestructura , Difracción de Rayos X/métodos , Algoritmos , Electrones , Rayos Láser , Difracción de Rayos X/instrumentación
8.
Proc Natl Acad Sci U S A ; 109(47): 19103-7, 2012 Nov 20.
Artículo en Inglés | MEDLINE | ID: mdl-23129631

RESUMEN

The ultrabright femtosecond X-ray pulses provided by X-ray free-electron lasers open capabilities for studying the structure and dynamics of a wide variety of systems beyond what is possible with synchrotron sources. Recently, this "probe-before-destroy" approach has been demonstrated for atomic structure determination by serial X-ray diffraction of microcrystals. There has been the question whether a similar approach can be extended to probe the local electronic structure by X-ray spectroscopy. To address this, we have carried out femtosecond X-ray emission spectroscopy (XES) at the Linac Coherent Light Source using redox-active Mn complexes. XES probes the charge and spin states as well as the ligand environment, critical for understanding the functional role of redox-active metal sites. Kß(1,3) XES spectra of Mn(II) and Mn(2)(III,IV) complexes at room temperature were collected using a wavelength dispersive spectrometer and femtosecond X-ray pulses with an individual dose of up to >100 MGy. The spectra were found in agreement with undamaged spectra collected at low dose using synchrotron radiation. Our results demonstrate that the intact electronic structure of redox active transition metal compounds in different oxidation states can be characterized with this shot-by-shot method. This opens the door for studying the chemical dynamics of metal catalytic sites by following reactions under functional conditions. The technique can be combined with X-ray diffraction to simultaneously obtain the geometric structure of the overall protein and the local chemistry of active metal sites and is expected to prove valuable for understanding the mechanism of important metalloproteins, such as photosystem II.

9.
Proc Natl Acad Sci U S A ; 109(25): 9721-6, 2012 Jun 19.
Artículo en Inglés | MEDLINE | ID: mdl-22665786

RESUMEN

Most of the dioxygen on earth is generated by the oxidation of water by photosystem II (PS II) using light from the sun. This light-driven, four-photon reaction is catalyzed by the Mn(4)CaO(5) cluster located at the lumenal side of PS II. Various X-ray studies have been carried out at cryogenic temperatures to understand the intermediate steps involved in the water oxidation mechanism. However, the necessity for collecting data at room temperature, especially for studying the transient steps during the O-O bond formation, requires the development of new methodologies. In this paper we report room temperature X-ray diffraction data of PS II microcrystals obtained using ultrashort (< 50 fs) 9 keV X-ray pulses from a hard X-ray free electron laser, namely the Linac Coherent Light Source. The results presented here demonstrate that the "probe before destroy" approach using an X-ray free electron laser works even for the highly-sensitive Mn(4)CaO(5) cluster in PS II at room temperature. We show that these data are comparable to those obtained in synchrotron radiation studies as seen by the similarities in the overall structure of the helices, the protein subunits and the location of the various cofactors. This work is, therefore, an important step toward future studies for resolving the structure of the Mn(4)CaO(5) cluster without any damage at room temperature, and of the reaction intermediates of PS II during O-O bond formation.


Asunto(s)
Cristalografía por Rayos X/métodos , Complejo de Proteína del Fotosistema II/química , Catálisis , Cristalización , Modelos Moleculares
10.
Opt Express ; 22(23): 28914-25, 2014 Nov 17.
Artículo en Inglés | MEDLINE | ID: mdl-25402130

RESUMEN

We use a Mach-Zehnder type autocorrelator to split and delay XUV pulses from the FLASH soft X-ray laser for triggering and subsequently probing the explosion of aerosolised sugar balls. FLASH was running at 182 eV photon energy with pulses of 70 fs duration. The delay between the pump-probe pulses was varied between zero and 5 ps, and the pulses were focused to reach peak intensities above 10¹6W/cm² with an off-axis parabola. The direct pulse triggered the explosion of single aerosolised sucrose nano-particles, while the delayed pulse probed the exploding structure. The ejected ions were measured by ion time of flight spectrometry, and the particle sizes were measured by coherent diffractive imaging. The results show that sucrose particles of 560-1000 nm diameter retain their size for about 500 fs following the first exposure. Significant sample expansion happens between 500 fs and 1 ps. We present simulations to support these observations.


Asunto(s)
Electrones , Imagenología Tridimensional/métodos , Rayos Láser , Nanosferas/química , Análisis Espectral/métodos , Sacarosa/química , Simulación por Computador , Hidrógeno/química , Iones , Termodinámica , Rayos X
11.
Nature ; 448(7154): 676-9, 2007 Aug 09.
Artículo en Inglés | MEDLINE | ID: mdl-17687320

RESUMEN

Extremely intense and ultrafast X-ray pulses from free-electron lasers offer unique opportunities to study fundamental aspects of complex transient phenomena in materials. Ultrafast time-resolved methods usually require highly synchronized pulses to initiate a transition and then probe it after a precisely defined time delay. In the X-ray regime, these methods are challenging because they require complex optical systems and diagnostics. Here we propose and apply a simple holographic measurement scheme, inspired by Newton's 'dusty mirror' experiment, to monitor the X-ray-induced explosion of microscopic objects. The sample is placed near an X-ray mirror; after the pulse traverses the sample, triggering the reaction, it is reflected back onto the sample by the mirror to probe this reaction. The delay is encoded in the resulting diffraction pattern to an accuracy of one femtosecond, and the structural change is holographically recorded with high resolution. We apply the technique to monitor the dynamics of polystyrene spheres in intense free-electron-laser pulses, and observe an explosion occurring well after the initial pulse. Our results support the notion that X-ray flash imaging can be used to achieve high resolution, beyond radiation damage limits for biological samples. With upcoming ultrafast X-ray sources we will be able to explore the three-dimensional dynamics of materials at the timescale of atomic motion.


Asunto(s)
Holografía/métodos , Poliestirenos/química , Rayos X , Electrones , Rayos Láser , Microesferas , Factores de Tiempo
12.
Acta Crystallogr D Biol Crystallogr ; 68(Pt 11): 1584-7, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23090408

RESUMEN

An electrospun liquid microjet has been developed that delivers protein microcrystal suspensions at flow rates of 0.14-3.1 µl min(-1) to perform serial femtosecond crystallography (SFX) studies with X-ray lasers. Thermolysin microcrystals flowed at 0.17 µl min(-1) and diffracted to beyond 4 Å resolution, producing 14,000 indexable diffraction patterns, or four per second, from 140 µg of protein. Nanoflow electrospinning extends SFX to biological samples that necessitate minimal sample consumption.


Asunto(s)
Cristalografía por Rayos X/instrumentación , Cristalización , Cristalografía por Rayos X/economía , Campos Electromagnéticos , Diseño de Equipo , Cinética , Rayos Láser , Tamaño de la Muestra , Termolisina/química
13.
Phys Rev Lett ; 104(6): 064801, 2010 Feb 12.
Artículo en Inglés | MEDLINE | ID: mdl-20366823

RESUMEN

Intense and ultrashort x-ray pulses from free-electron lasers open up the possibility for near-atomic resolution imaging without the need for crystallization. Such experiments require high photon fluences and pulses shorter than the time to destroy the sample. We describe results with a new femtosecond pump-probe diffraction technique employing coherent 0.1 keV x rays from the FLASH soft x-ray free-electron laser. We show that the lifetime of a nanostructured sample can be extended to several picoseconds by a tamper layer to dampen and quench the sample explosion, making <1 nm resolution imaging feasible.


Asunto(s)
Difracción de Rayos X/métodos , Electrones , Rayos Láser , Rayos X
15.
Sci Adv ; 5(5): eaav8801, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-31058226

RESUMEN

The possibility of imaging single proteins constitutes an exciting challenge for x-ray lasers. Despite encouraging results on large particles, imaging small particles has proven to be difficult for two reasons: not quite high enough pulse intensity from currently available x-ray lasers and, as we demonstrate here, contamination of the aerosolized molecules by nonvolatile contaminants in the solution. The amount of contamination on the sample depends on the initial droplet size during aerosolization. Here, we show that, with our electrospray injector, we can decrease the size of aerosol droplets and demonstrate virtually contaminant-free sample delivery of organelles, small virions, and proteins. The results presented here, together with the increased performance of next-generation x-ray lasers, constitute an important stepping stone toward the ultimate goal of protein structure determination from imaging at room temperature and high temporal resolution.

16.
J Vis Exp ; (126)2017 08 22.
Artículo en Inglés | MEDLINE | ID: mdl-28872125

RESUMEN

The precise details of the interaction of intense X-ray pulses with matter are a topic of intense interest to researchers attempting to interpret the results of femtosecond X-ray free electron laser (XFEL) experiments. An increasing number of experimental observations have shown that although nuclear motion can be negligible, given a short enough incident pulse duration, electronic motion cannot be ignored. The current and widely accepted models assume that although electrons undergo dynamics driven by interaction with the pulse, their motion could largely be considered 'random'. This would then allow the supposedly incoherent contribution from the electronic motion to be treated as a continuous background signal and thus ignored. The original aim of our experiment was to precisely measure the change in intensity of individual Bragg peaks, due to X-ray induced electronic damage in a model system, crystalline C60. Contrary to this expectation, we observed that at the highest X-ray intensities, the electron dynamics in C60 were in fact highly correlated, and over sufficiently long distances that the positions of the Bragg reflections are significantly altered. This paper describes in detail the methods and protocols used for these experiments, which were conducted both at the Linac Coherent Light Source (LCLS) and the Australian Synchrotron (AS) as well as the crystallographic approaches used to analyse the data.


Asunto(s)
Fulerenos/metabolismo , Nanopartículas/metabolismo , Difracción de Rayos X/métodos , Modelos Biológicos
17.
IUCrJ ; 4(Pt 3): 251-262, 2017 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-28512572

RESUMEN

This study explores the capabilities of the Coherent X-ray Imaging Instrument at the Linac Coherent Light Source to image small biological samples. The weak signal from small samples puts a significant demand on the experiment. Aerosolized Omono River virus particles of ∼40 nm in diameter were injected into the submicrometre X-ray focus at a reduced pressure. Diffraction patterns were recorded on two area detectors. The statistical nature of the measurements from many individual particles provided information about the intensity profile of the X-ray beam, phase variations in the wavefront and the size distribution of the injected particles. The results point to a wider than expected size distribution (from ∼35 to ∼300 nm in diameter). This is likely to be owing to nonvolatile contaminants from larger droplets during aerosolization and droplet evaporation. The results suggest that the concentration of nonvolatile contaminants and the ratio between the volumes of the initial droplet and the sample particles is critical in such studies. The maximum beam intensity in the focus was found to be 1.9 × 1012 photons per µm2 per pulse. The full-width of the focus at half-maximum was estimated to be 500 nm (assuming 20% beamline transmission), and this width is larger than expected. Under these conditions, the diffraction signal from a sample-sized particle remained above the average background to a resolution of 4.25 nm. The results suggest that reducing the size of the initial droplets during aerosolization is necessary to bring small particles into the scope of detailed structural studies with X-ray lasers.

18.
J Mol Biol ; 354(1): 173-83, 2005 Nov 18.
Artículo en Inglés | MEDLINE | ID: mdl-16236315

RESUMEN

The folding of a polypeptide from an extended state to a well-defined conformation is studied using microsecond classical molecular dynamics (MD) simulations and replica exchange molecular dynamics (REMD) simulations in explicit solvent and in vacuo. It is shown that the solvated peptide folds many times in the REMD simulations but only a few times in the conventional simulations. From the folding events in the classical simulations we estimate an approximate folding time of 1-2 micros. The REMD simulations allow enough sampling to deduce a detailed Gibbs free energy landscape in three dimensions. The global minimum of the energy landscape corresponds to the native state of the peptide as determined previously by nuclear magnetic resonance (NMR) experiments. Starting from an extended state it takes about 50 ns before the native structure appears in the REMD simulations, about an order of magnitude faster than conventional MD. The calculated melting curve is in good qualitative agreement with experiment. In vacuo, the peptide collapses rapidly to a conformation that is substantially different from the native state in solvent.


Asunto(s)
Simulación por Computador , Compuestos Orgánicos/química , Péptidos/química , Conformación Proteica , Pliegue de Proteína , Cinética , Modelos Químicos , Modelos Moleculares , Resonancia Magnética Nuclear Biomolecular , Reproducibilidad de los Resultados , Solventes , Temperatura , Termodinámica , Vacio
19.
Sci Adv ; 2(9): e1601186, 2016 09.
Artículo en Inglés | MEDLINE | ID: mdl-27626076

RESUMEN

X-ray free-electron lasers (XFELs) deliver x-ray pulses with a coherent flux that is approximately eight orders of magnitude greater than that available from a modern third-generation synchrotron source. The power density of an XFEL pulse may be so high that it can modify the electronic properties of a sample on a femtosecond time scale. Exploration of the interaction of intense coherent x-ray pulses and matter is both of intrinsic scientific interest and of critical importance to the interpretation of experiments that probe the structures of materials using high-brightness femtosecond XFEL pulses. We report observations of the diffraction of extremely intense 32-fs nanofocused x-ray pulses by a powder sample of crystalline C60. We find that the diffraction pattern at the highest available incident power significantly differs from the one obtained using either third-generation synchrotron sources or XFEL sources operating at low output power and does not correspond to the diffraction pattern expected from any known phase of crystalline C60. We interpret these data as evidence of a long-range, coherent dynamic electronic distortion that is driven by the interaction of the periodic array of C60 molecular targets with intense x-ray pulses of femtosecond duration.


Asunto(s)
Fulerenos/química , Nanopartículas/química , Difracción de Rayos X , Cristalografía por Rayos X , Electrones , Rayos Láser , Luz , Sincrotrones , Rayos X
20.
Sci Data ; 3: 160058, 2016 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-27479514

RESUMEN

Structural studies on living cells by conventional methods are limited to low resolution because radiation damage kills cells long before the necessary dose for high resolution can be delivered. X-ray free-electron lasers circumvent this problem by outrunning key damage processes with an ultra-short and extremely bright coherent X-ray pulse. Diffraction-before-destruction experiments provide high-resolution data from cells that are alive when the femtosecond X-ray pulse traverses the sample. This paper presents two data sets from micron-sized cyanobacteria obtained at the Linac Coherent Light Source, containing a total of 199,000 diffraction patterns. Utilizing this type of diffraction data will require the development of new analysis methods and algorithms for studying structure and structural variability in large populations of cells and to create abstract models. Such studies will allow us to understand living cells and populations of cells in new ways. New X-ray lasers, like the European XFEL, will produce billions of pulses per day, and could open new areas in structural sciences.


Asunto(s)
Rayos Láser , Difracción de Rayos X , Células , Cristalografía por Rayos X , Cianobacterias , Electrones , Modelos Moleculares , Modelos Teóricos , Nanopartículas , Proteínas , Pulso Arterial , Factores de Tiempo , Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA