1.
Pediatr Radiol ; 52(8): 1437-1445, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35303134

RESUMEN

BACKGROUND: Chest radiography is the most frequent X-ray examination performed in the neonatal period. However, commonly used dosimetric entities do not describe the radiation risk sufficiently. OBJECTIVE: The aim of this study was to investigate selected organ doses and total body dose of chest radiographs in preterm and full-term neonates and infants. MATERIALS AND METHODS: In this retrospective study, we evaluated 1,064 chest radiographs of 136 preterm and 305 full-term babies with respect to field size and centering. We calculated the entrance dose from the dose-area product. Upper and lower field borders referred to the corresponding vertebrae. We calculated individual organ doses of the thyroid, the breast, the liver and active bone marrow for each chest radiograph using the neonatal PCXMC program, a Monte Carlo program for calculating patient doses in medical X-ray examinations. RESULTS: The median field size of chest radiographs ranged from 90 cm2 in preterm neonates at birth to 290 cm2 in full-term infants at the age of 6 months. Median values of entrance dose varied, depending on age, from 15 µGy to 25 µGy. The median organ doses ranged 1-20 µSv for the thyroid, 3-30 µSv for the breast, 2-20 µSv for the liver and 0.5-3.5 µSv for the bone marrow in preterm and full-term neonates and infants, respectively. CONCLUSION: The analysis of chest radiographs in preterm and full-term neonates and infants revealed high variability in field size. By contrast, the entrance dose varied to a minor extent. Organ dose calculations using the PCXMC program might be a valuable tool to calculate the individual radiation risk in neonates and infants.


Asunto(s)
Radiografía Torácica , Humanos , Lactante , Recién Nacido , Método de Montecarlo , Fantasmas de Imagen , Dosis de Radiación , Radiografía , Estudios Retrospectivos
2.
J Radiol Prot ; 39(4): 1074-1091, 2019 Jul 25.
Artículo en Inglés | MEDLINE | ID: mdl-31342929

RESUMEN

Studies on children exposed to ionising radiation by computed tomography (CT) indicate an increased risk of leukemia and central nervous system (CNS) tumors. Evidence of the risks associated with diagnostic x-ray examinations, the most frequent examination in pediatric radiology, in which the radiation dose is up to 750 times lower compared to CT examinations, is less clear. This study presents results of the second follow-up for the risk of childhood cancer in a cohort of children (<15 years) with diagnostic x-ray exposure at a large German hospital during 1976-2003 followed for additional 10 years until 2016. With a latency period of 6 months, 92 998 children contributed 794 549 person-years. The median effective dose was 7 µSv. Hundred incident cancer cases were identified: 35 leukemia, 13 lymphomas, 12 CNS tumors, 15 blastomas, 15 sarcomas and 10 other solid tumors, consisting of six germ cells tumors, three thyroid cancers and one adrenocortical carcinoma. For all cancer cases combined the standardised incidence ratio (SIR) was 1.14 (95% confidence interval (CI) 0.93-1.39), for leukemia 1.15 (95% CI 0.63-1.61), for lymphomas 1.03 (95% CI 0.55-1.76), for CNS tumors 0.65 (95% CI 0.34-1.14), for blastomas 1.77 (95% CI 0.91-2.91), for sarcomas 1.28 (95% CI 0.71-2.11) and for other solid tumors 2.38 (95% CI 1.14-4.38). Dose-response analysis using Poisson regression revealed no significant trend for dose groups. Results did not differ substantially with a latency period of 2 years for all cancer entities and 5 years for solid tumors in sensitivity analyses. Overall, the null results of the first follow-up were confirmed. Although an association between radiation exposure and a risk for certain solid tumors like thyroid cancer is known, the significantly increased SIR in the group of other solid tumors must be critically interpreted in the context of the small number of cases and the very low doses of radiation exposure in this group.

3.
Eur Radiol ; 25(9): 2617-26, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25854215

RESUMEN

OBJECTIVES: Radiation exposure of patients during endovascular aneurysm repair (EVAR) procedures ranks in the upper sector of medical exposure. Thus, estimation of radiation doses achieved during EVAR is of great importance. MATERIAL AND METHODS: Organ doses (OD) and effective doses (ED) administered to 17 patients receiving EVAR were determined (1) from the exposure parameters by performing Monte Carlo simulations in mathematical phantoms and (2) by measurements with thermoluminescent dosimeters in a physical anthropomorphic phantom. RESULTS: The mean fluoroscopy time was 26 min, the mean dose area product was 24995 cGy cm2. The mean ED was 34.8 mSv, ODs up to 626 mSv were found. Whereas digital subtraction angiographies (DSA) and fluoroscopies each contributed about 50% to the cumulative ED, the ED rates of DSAs were found to be ten times higher than those of fluoroscopies. Doubling of the field size caused an ED rate enhancement up to a factor of 3. CONCLUSION: EVAR procedures cause high radiation exposure levels that exceed the values published thus far. As a consequence, (1) DSAs should be only performed when necessary and with a low image rate, (2) fluoroscopies should be kept as short as possible, and (3) field sizes should be minimized. KEY POINTS: • During endovascular aneurysm repair (EVAR) considerable patient doses are achieved. • For each EVAR procedure organ (OD) and effective (ED) doses were determined. • The mean ED was 34.8 mSv, the highest OD was 626 mSv. • Number of DSAs, fluoroscopy durations and field sizes should be minimized.


Asunto(s)
Aneurisma de la Aorta/diagnóstico por imagen , Aneurisma de la Aorta/cirugía , Procedimientos Endovasculares , Método de Montecarlo , Dosis de Radiación , Anciano , Angiografía de Substracción Digital , Aorta/cirugía , Aortografía , Simulación por Computador , Femenino , Fluoroscopía , Humanos , Masculino , Fantasmas de Imagen , Estudios Prospectivos , Factores de Tiempo
4.
Eur Radiol ; 24(5): 969-79, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24531843

RESUMEN

OBJECTIVES: To compare the effects of different arm positions on dose exposure and image quality (IQ) in cervical spine CT after trauma in different patient groups. METHODS: Patients in standard (STD = 126) and in swimmer's position (SWIM = 254) were included. Body mass index (BMI subgroup 1 = underweight to subgroup 4 = obese), anterior-posterior diameter (AP), left-right diameter (LR), area of an ellipse (AoE) and angle between the humeral heads (optimal STD < 3°, optimal SWIM > 10°) were used as grouping criteria. Computed tomography dose index (CTDI) was documented. Two radiologists rated the IQ at three levels (CV1/2, CV4/5, CV7/T1) using a semi-quantitative scale (0 = not diagnostic, 1 = diagnostic with limitations, 2 = diagnostic without limitations). The Mann-Whitney U test correlations of grouping criteria with dose effects and intra-class correlation (ICC) were calculated. RESULTS: ICC was 0.87. BMI grouping showed the strongest correlation with dose effects: CTDI of optimal STD versus optimal SWIM positioning was 3.17 mGy versus 2.46 mGy (subgroup 1), 5.47 mGy versus 3.97 mGy (subgroup 2), 7.35 mGy versus 5.96 mGy (subgroup 3) and 8.71 mGy versus 8.18 mGy (subgroup 4). Mean IQ at CV7/T1 was 1.65 versus 1.23 (subgroup 1), 1.27 versus 1.46 (subgroup 2), 1.06 versus 1.46 (subgroup 3), 0.79 versus 1.5 (subgroup 4). CONCLUSION: Patients with a BMI > 20 kg/m(2) benefited from both potential dose reduction and improved image quality at the critical cervicothoracic junction when swimmer's position was used. KEY POINTS: • BMI is a useful metric for personalized optimization in CT for the c-spine. • Using swimmer's position, patients can benefit from dose reduction. • In some patients a superior image quality can be achieved with swimmer's position. • For swimmer's positioning an angle of more than 10° is optimal.


Asunto(s)
Vértebras Cervicales/diagnóstico por imagen , Postura , Natación/fisiología , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Relación Dosis-Respuesta en la Radiación , Servicios Médicos de Urgencia/métodos , Femenino , Cabeza/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Cuello/diagnóstico por imagen , Dosis de Radiación , Tomografía Computarizada por Rayos X/normas
5.
Pediatr Radiol ; 44(4): 434-56, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24509648

RESUMEN

BACKGROUND: Knowledge of organ and effective doses achieved during paediatric x-ray examinations is an important prerequisite for assessment of radiation burden to the patient. OBJECTIVE: Conversion coefficients for reconstruction of organ and effective doses from entrance doses for segmental spine radiographs of 0-, 1-, 5-, 10-, 15- and 30-year-old patients are provided regarding the Guidelines of Good Radiographic Technique of the European Commission. MATERIALS AND METHODS: Using the personal computer program PCXMC developed by the Finnish Centre for Radiation and Nuclear Safety (Säteilyturvakeskus STUK), conversion coefficients for conventional segmental spine radiographs were calculated performing Monte Carlo simulations in mathematical hermaphrodite phantom models describing patients of different ages. The clinical variation of beam collimation was taken into consideration by defining optimal and suboptimal radiation field settings. RESULTS: Conversion coefficients for the reconstruction of organ doses in about 40 organs and tissues from measured entrance doses during cervical, thoracic and lumbar spine radiographs of 0-, 1-, 5-, 10-, 15- and 30-year-old patients were calculated for the standard sagittal and lateral beam projections and the standard focus detector distance of 115 cm. CONCLUSION: The conversion coefficients presented may be used for organ dose assessments from entrance doses measured during spine radiographs of patients of all age groups and all field settings within the optimal and suboptimal standard field settings.


Asunto(s)
Dosis de Radiación , Columna Vertebral/diagnóstico por imagen , Adolescente , Adulto , Algoritmos , Niño , Preescolar , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Método de Montecarlo , Variaciones Dependientes del Observador , Órganos en Riesgo/efectos de la radiación , Fantasmas de Imagen , Radiografía , Radiometría/métodos
6.
Pediatr Radiol ; 44(9): 1110-23, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24805203

RESUMEN

BACKGROUND: Knowledge of organ and effective doses achieved during paediatric X-ray examinations is an important prerequisite for assessment of radiation burden to the patient. OBJECTIVE: Conversion coefficients for reconstruction of organ and effective doses from entrance doses for pelvis and hip joint radiographs of 0-, 1-, 5-, 10-, 15- and 30-year-old patients are provided regarding the Guidelines of Good Radiographic Technique of the European Commission. MATERIALS AND METHODS: Using the personal computer program PCXMC developed by the Finnish Centre for Radiation and Nuclear Safety (Säteilyturvakeskus STUK), conversion coefficients for conventional pelvis and hip joint radiographs were calculated by performing Monte Carlo simulations in mathematical hermaphrodite phantom models representing patients of different ages. The clinical variation of radiation field settings was taken into consideration by defining optimal and suboptimal standard field settings. RESULTS: Conversion coefficients for the reconstruction of organ doses in about 40 organs and tissues from measured entrance doses during pelvis and hip joint radiographs of 0-, 1-, 5-, 10-, 15- and 30-year-old patients were calculated for the standard sagittal beam projection and the standard focus detector distance of 115 cm. CONCLUSION: The conversion coefficients presented can be used for organ dose assessments from entrance doses measured during pelvis and hip joint radiographs of children and young adults with all field settings within the optimal and suboptimal standard field settings.


Asunto(s)
Articulación de la Cadera/diagnóstico por imagen , Pelvis/diagnóstico por imagen , Dosis de Radiación , Radiometría/métodos , Adolescente , Adulto , Carga Corporal (Radioterapia) , Niño , Preescolar , Humanos , Lactante , Recién Nacido , Método de Montecarlo , Fantasmas de Imagen , Radiografía , Programas Informáticos
7.
Radiat Environ Biophys ; 51(2): 103-11, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22310909

RESUMEN

Radiation protection is a topic of great public concern and of many scientific investigations, because ionizing radiation is an established risk factor for leukaemia and many solid tumours. Exposure of the public to ionizing radiation includes exposure to background radiation, as well as medical and occupational exposures. A large fraction of the exposure from diagnostic procedures comes from medical imaging. Computed tomography (CT) is the major single contributor of diagnostic radiation exposure. An increase in the use of CTs has been reported over the last decades in many countries. Children have smaller bodies and lower shielding capacities, factors that affect the individual organ doses due to medical imaging. Several risk models have been applied to estimate the cancer burden caused by ionizing radiation from CT. All models predict higher risks for cancer among children exposed to CT as compared to adults. However, the cancer risk associated with CT has not been assessed directly in epidemiological studies. Here, plans are described to conduct an historical cohort study to investigate the cancer incidence in paediatric patients exposed to CT before the age of 15 in Germany. Patients will be recruited from radiology departments of several hospitals. Their individual exposure will be recorded, and time-dependent cumulative organ doses will be calculated. Follow-up for cancer incidence via the German Childhood Cancer Registry will allow computation of standardized incidence ratios using population-based incidence rates for childhood cancer. Dose-response modelling and analyses for subgroups of children based on the indication for and the result of the CT will be performed.


Asunto(s)
Neoplasias Inducidas por Radiación/epidemiología , Tomografía Computarizada por Rayos X/estadística & datos numéricos , Adolescente , Niño , Preescolar , Estudios de Cohortes , Estudios de Factibilidad , Alemania/epidemiología , Humanos , Incidencia , Radiación Ionizante , Medición de Riesgo , Tomografía Computarizada por Rayos X/efectos adversos
8.
AJR Am J Roentgenol ; 197(1): 217-23, 2011 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-21701033

RESUMEN

OBJECTIVE: Little is known about the long-term effects of exposure to diagnostic ionizing radiation in childhood. Current estimates are made with models derived mainly from studies of atomic bomb survivors, a population that differs from today's patients in many respects. MATERIALS AND METHODS: We analyzed the cancer incidence among children who underwent diagnostic x-ray exposures between 1976 and 2003 in a large German university hospital. We reconstructed individual radiation doses for each examination and sorted results by groups of referral criteria for all cancers combined, solid tumors, and leukemia and lymphoma combined. RESULTS: A total of 68 incidence cancer cases between 1980 and 2006 were identified in a 78,527-patient cohort in the German childhood cancer registry: 28 leukemia, nine lymphoma, six tumors of the CNS, and 25 other tumors. The standardized incidence ratio for all cancers was 0.97 (95% CI, 0.75-1.23). Dose-response relations were analyzed by multivariable Poisson regression. Although the cancer incidence risk differed by initial referral criterion for radiographic examination, a positive dose-response relation was observed in five patients with endocrine or metabolic disease. CONCLUSION: Overall, we observed no increase in cancer risk among children and youths with very low radiation doses from diagnostic radiation, which is compatible with model calculations. The growing use of CT warrants further studies to assess associated cancer risk. Our work is an early contribution of epidemiologic data for quantifying these risks among young patients.


Asunto(s)
Neoplasias Inducidas por Radiación/epidemiología , Modelos de Riesgos Proporcionales , Radiografía/estadística & datos numéricos , Adolescente , Niño , Preescolar , Estudios de Cohortes , Femenino , Alemania/epidemiología , Humanos , Incidencia , Lactante , Recién Nacido , Masculino , Medición de Riesgo , Factores de Riesgo , Rayos X
9.
J Clin Med ; 9(2)2020 Jan 22.
Artículo en Inglés | MEDLINE | ID: mdl-31979109

RESUMEN

OBJECTIVE: To evaluate the incidence of cancer within the first 15 years of life in children who underwent cardiac catheterization under the age of one year. METHODS: In this retrospective, single center study, 2770 infants (7.8% with trisomy 21) were studied. All infants underwent cardiac catheterization under one year of age between January 1980 and December 1998. Newly diagnosed cancer in the first 15 years of life was assessed through record linkage to the German Childhood Cancer Registry (GCCR). Cancer risk in study patients was compared to the GCCR population of children less than 15 years. Patients with trisomy 21 were compared to the Danish Cytogenic Register for trisomy 21. Effective radiation doses were calculated for each tumor patient and 60 randomly selected patients who did not develop cancer. RESULTS: In total, 24,472.5 person-years were analyzed. Sixteen children developed cancer, while 3.64 were expected (standardized incidence ratio (SIR) = 4.4, 95% confidence interval (CI): 2.5-7.2, p < 0.001). There was no preferred cancer type. The observed incidence of leukemia and solid tumors in trisomy 21 was only slightly higher (1 in 476 py) than expected (1 in 609 py, p = 0.64). There was no direct relationship between the radiation dose and the incidence of cancer. CONCLUSION: Cardiac catherization in the first year of life was associated with a significantly increased cancer risk in a population with congenital heart disease.

10.
Radiat Res ; 171(4): 504-12, 2009 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-19397451

RESUMEN

Ionizing radiation is an established cause of cancer, yet little is known about the health effects of doses from diagnostic examinations in children. The risk of childhood cancer was studied in a cohort of 92.957 children who had been examined with diagnostic X rays in a large German hospital during 1976-2003. Radiation doses were reconstructed using the individual dose area product and other exposure parameters, together with conversion coefficients developed specifically for the medical devices and standards used at the radiology department. Newly diagnosed cancers occurring between 1980 and 2006 were determined through record linkage to the German Childhood Cancer Registry. The median radiation dose was 7 microSv. Eight-seven incident cases were found in the cohort: 33 leukemia, 13 lymphoma, 10 central nervous system tumors, and 31 other tumors. The standardized incidence ratio (SIR) for all cancers was 0.99 (95% CI: 0.79-1.22). No trend in the incidence of total cancer, leukemia or solid tumors with increasing radiation dose was observed in the SIR analysis or in the multivariate Poisson regression. Risk did not differ significantly in girls and boys. Overall, while no increase in cancer risk with diagnostic radiation was observed, the results are compatible with a broad range of risk estimates.


Asunto(s)
Neoplasias Inducidas por Radiación/epidemiología , Neoplasias Inducidas por Radiación/etiología , Neoplasias/epidemiología , Neoplasias/etiología , Adolescente , Adulto , Niño , Preescolar , Estudios de Cohortes , Femenino , Alemania , Humanos , Incidencia , Lactante , Masculino , Análisis Multivariante , Radiación Ionizante , Sistema de Registros , Rayos X
12.
Z Med Phys ; 24(2): 123-37, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24630933

RESUMEN

Estimations of organ doses DT received during computed tomographic examinations are usually performed by applying conversion factors to basic dose indicators like the computed tomography dose index (CTDI) or the dose-length-product (DLP). In addition to the existing conversion factors for beam apertures of 5 mm or 10 mm, we present new DLP-DT conversion factors adapted to high-resolution CT (HRCT) examinations of infants and young children with beam apertures of the order of 1 mm and under consideration of bow tie filtration. Calculations are performed on mathematical MIRD phantoms for an age range from 0, 1, 5, 10, 15 up to (for comparison) 30 years by adapting PCXMC, a Monte Carlo algorithm originally developed by STUK (Helsinki, Finland) for dose reconstructions in projection radiography. For this purpose, each single slice CT examination is approximated by a series of corresponding virtual planar radiographies comprising all focus positions. The transformation of CT exposure parameters into exposure parameters of the series of corresponding planar radiographies is performed by a specially developed algorithm called XCT. The DLP values are evaluated using the EGSRay code. The new method is verified at a beam aperture of 10 mm by comparison with formerly published conversion factors. We show that the higher spatial resolution leads to an enhanced DLP-DT conversion factor if a small organ (e. g. thyroid gland, mammae, uterus, ovaries, testes) is exactly met by the chosen CT slice, while the conversion factor is drastically reduced if the chosen CT slice is positioned above or below the organ. This effect is utilized for dose-saving examinations with only a few single slices instead a full scan, which technique is applied in about 10% of all paediatric chest CT examinations.


Asunto(s)
Algoritmos , Carga Corporal (Radioterapia) , Modelos Biológicos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Recuento Corporal Total/métodos , Irradiación Corporal Total/métodos , Absorción de Radiación , Niño , Preescolar , Simulación por Computador , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Dosis de Radiación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad