1.
J Endovasc Ther ; 26(6): 865-870, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31455137

RESUMEN

Purpose: To compare balloon-expandable covered stents (BECS) available for use as renal chimney grafts to the Advanta V12 approved for use with the Endurant endograft. Materials and Methods: A silicone model was manufactured based on preoperative computed tomography angiography (CTA) scans of a patient with a 7-cm juxtarenal aneurysm treated with an Endurant bifurcated endograft and an Advanta V12 covered stent for the 6-mm-diameter right renal artery. The model was placed in a flow box filled with a 37°C blood-mimicking solution equipped with a pulsatile pumping system (140/60 mm Hg). The tested BECS were the Advanta V12, the VBX, and the BeGraft+. A 36-mm-diameter Endurant II endograft with a 16-mm-diameter contralateral limb and a 6×59-mm BECS chimney graft were used in 9 consecutive tests (3 for each combination). After each implantation, the model was placed in the CT scanner, and 2 radiologists blinded to the test device independently measured the gutter areas and the patent chimney graft lumen at the level of the Endurant's suprarenal stent, at the level of the chimney's maximum curvature, and 10 mm inside the renal artery. The intraclass correlation coefficients (ICC) were calculated to assess interreader reliability. Results: The mean gutter areas were 19.3±7, 20.2±8, and 22.3±8 mm2 for the Advanta, VBX, and BeGraft+, respectively (all p>0.05). At the level of the aortic endograft's suprarenal stent struts, the mean diameter of the Advanta V12, VBX, and BeGraft+ were 4.46±0.3, 4.12±0.4, and 4.12±0.3 mm, respectively (all p>0.05). At the level of the maximum chimney graft angulation, the mean diameters were 3.77±0.3, 4.16±0.1, and 3.74±0.3 mm, respectively (all p>0.05). In the right renal artery, the mean diameters were 3.91±0.2, 4.05±0.9, and 4.3±0.4 mm, respectively (all p>0.05). The ICCs varied between 0.7 and 0.9, indicating good agreement between readers. Conclusion: These in vitro findings showed comparable results between the Advanta V12 and the available BECS used in conjunction with the Endurant endograft according to the instructions for use. Further clinical evaluation is needed to confirm these results.


Asunto(s)
Angioplastia de Balón/instrumentación , Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Arteria Renal/cirugía , Stents , Angioplastia de Balón/efectos adversos , Aorta Abdominal/diagnóstico por imagen , Aorta Abdominal/fisiopatología , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/fisiopatología , Implantación de Prótesis Vascular/efectos adversos , Hemodinámica , Humanos , Modelos Anatómicos , Modelos Cardiovasculares , Diseño de Prótesis , Arteria Renal/diagnóstico por imagen , Arteria Renal/fisiopatología , Circulación Renal
2.
Eur J Orthop Surg Traumatol ; 26(7): 793-803, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27106585

RESUMEN

PURPOSE: To present a method of posterior arch and lateral mass screw (PALMS) insertion and to prove its feasibility. METHODS: Four formalin-fixed specimens and 40 macerated atlas vertebras were used to describe the relevant anatomy. The height of the posterior arch was measured on 42 consecutive patients using standard CT of the cervical spine. The operative technique and the special CT reconstructions used for preoperative planning are described. Eight patients underwent posterior fixation using this technique. RESULTS: We described the relevant anatomy and important anatomical landmarks of the posterior arch of the atlas. PALMS placement was modified according to these anatomical findings. Fifteen PALMSs were placed in eight patients using this technique without vascular or neural injury. CONCLUSION: It is feasible to place PALMS using the described technique. CT angiography is of crucial importance for preoperative planning using the described special reconstructions. The arch posterior to the lateral mass (APLM) is defined as the bone stock situated posterior to the lateral mass, respecting its convergence. The ideal entry point for a PALMS is on the APLM above the center of the converging lateral mass. A complete or incomplete ponticulus posticus and a retrotransverse foramen or groove can be used as an accessory landmark to refine the entry point.


Asunto(s)
Tornillos Óseos , Atlas Cervical/anatomía & histología , Adulto , Cadáver , Arterias Carótidas/diagnóstico por imagen , Atlas Cervical/cirugía , Vértebras Cervicales/anatomía & histología , Vértebras Cervicales/lesiones , Vértebras Cervicales/cirugía , Angiografía por Tomografía Computarizada , Estudios de Factibilidad , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Implantación de Prótesis/métodos , Fracturas de la Columna Vertebral/patología , Fracturas de la Columna Vertebral/cirugía , Fusión Vertebral/instrumentación , Fusión Vertebral/métodos , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Arteria Vertebral/diagnóstico por imagen
3.
Acta Radiol ; 56(1): 42-50, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24399513

RESUMEN

BACKGROUND: Assesment of the coronary arteries after stent placement using coronary computed tomography angiography (CCTA) currently requires reconstruction of images with soft kernels for the assessment of atherosclerotic plaques and dedicated edge enhancing kernels for the evaluation of the stent lumen. PURPOSE: To evaluate a two-dimensional filter tool that provides instant postprocessing of images reconstructed with soft kernels into edge-enhanced images and vice versa and thus may eliminate the need for two separate reconstrcutions for the assessment of coronary artery stents using CCTA. MATERIAL AND METHODS: Twenty stents with a diameter of 3.0 mm placed in a vascular phantom were scanned with a dual-source CT using standard parameters. Images were reconstructed with a soft B30f and an edge-enhancing B46f kernel and postprocessed with the corresponding filter algorithm (F30 for B30f images; F46 for B46f images). The resulting four data-sets were evaluated for lumen visibility, intraluminal attenuation, and image noise by two independent readers. Results were validated in vivo against invasive coronary angiography in data-sets from patients with coronary artery stents. RESULTS: Average intraluminal attenuation was 552.6 HU, 527.3 HU, 207.9 HU, and 267.5 HU for B30f, F30, B46f, and F46 images, respectively (P < 0.0001). Average image noise was 11.3, 10.6, 19.2, and 15.0 HU, respectively (P < 0.0001). The visible stent diameter was significantly higher in the B46f (59.6%) and F46 images (54%) compared to the B30f (48.3%) and F30 (51.5%) images (P < 0.0001). In the patient study, lumen assessability was significantly better in B46f images than in F46 images. Sensitivity for stenosis detection was best in the original B46f images with a sensitivity of 67% and a specificity of 94%. CONCLUSION: The postprocessing filter reduces image noise, however currently it does not offer an alternative to image reconstruction using the edge-enhancing kernels for the evaluation of the stent lumen.


Asunto(s)
Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Stents , Tomografía Computarizada por Rayos X/métodos , Algoritmos , Prótesis Vascular , Angiografía Coronaria/instrumentación , Enfermedad de la Arteria Coronaria/cirugía , Vasos Coronarios/cirugía , Humanos , Fantasmas de Imagen , Intensificación de Imagen Radiográfica/métodos , Imagen Radiográfica por Emisión de Doble Fotón/instrumentación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
4.
Acad Radiol ; 2024 Apr 23.
Artículo en Inglés | MEDLINE | ID: mdl-38658212

RESUMEN

BACKGROUND: Delivering case-based collaborative learning (cCBL) at scale using technology that both presents the clinical problem authentically and seeks to foster quality group discussion is a challenge, especially argumentation which is critical for effective learning. The aim of this study was to investigate the presence of essential conditions to capitalize on a technology-enhanced cCBL scenario for teaching radiology and facilitating quality group discussion. METHODS: A questionnaire was administered to 114 fourth-year medical students who completed a technology-enhanced cCBL scenario for teaching neuroradiology. It consisted of individual online pre-class work and face-to-face in-class work, where group discussion followed individual work at a workstation. Items from the "Heedful Interrelating in Collaborative Educational Settings" scale and "positive emotional engagement" questionnaire assessed the quality of social-cognitive processes and emotional engagement during the group discussions. Structured interviews were used to explore the teachers' awareness of and engagement with the technology. RESULTS: The mean scores of most "heedfulness" items were below 3.5 (7-point scale), suggesting that participants did not enter the debriefing with a mindset conducive for argumentation. However, for the affective states "interest" and "enjoyment" the mean scores were above 5. Free text comments suggested participants enjoyed the superficial interactions, but did not necessarily engage in argumentation. Structured interviews revealed teachers were aware of the possibilities of the learning dashboard and used it as a common frame of reference, but did not really succeed to use it as a springboard for discussion. CONCLUSION: A technology-enhanced cCBL scenario is useful for teaching radiology in undergraduate medical education, but the added value of acquiring in-depth knowledge will only be achieved when students are aware of the importance of an "heedful" mind-set.

5.
Radiology ; 265(2): 393-401, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23012461

RESUMEN

PURPOSE: To establish an ex vivo experimental setup for imaging coronary atherosclerosis with coronary computed tomographic (CT) angiography, intravascular ultrasonography (US), and optical frequency domain imaging (OFDI) and to investigate their ability to help differentiate early from advanced coronary plaques. MATERIALS AND METHODS: All procedures were performed in accordance with local and federal regulations and the Declaration of Helsinki. Approval of the local Ethics Committee was obtained. Overall, 379 histologic cuts from nine coronary arteries from three donor hearts were acquired, coregistered among modalities, and assessed for the presence and composition of atherosclerotic plaque. To assess the discriminatory capacity of the different modalities in the detection of advanced lesions, c statistic analysis was used. Interobserver agreement was assessed with the Cohen κ statistic. RESULTS: Cross sections without plaque at coronary CT angiography and with fibrous plaque at OFDI almost never showed advanced lesions at histopathologic examination (odds ratio [OR]: 0.02 and 0.06, respectively; both P<.0001), while mixed plaque at coronary CT angiography, calcified plaque at intravascular US, and lipid-rich plaque at OFDI were associated with advanced lesions (OR: 2.49, P=.0003; OR: 2.60, P=.002; and OR: 31.2, P<.0001, respectively). OFDI had higher accuracy for discriminating early from advanced lesions than intravascular US and coronary CT angiography (area under the receiver operating characteristic curve: 0.858 [95% confidence interval {CI}: 0.802, 0.913], 0.631 [95% CI: 0.554, 0.709], and 0.679 [95% CI: 0.618, 0.740]; respectively, P<.0001). Interobserver agreement was excellent for OFDI and coronary CT angiography (κ=0.87 and 0.85, respectively) and was good for intravascular US (κ=0.66). CONCLUSION: Systematic and standardized comparison between invasive and noninvasive modalities for coronary plaque characterization in ex vivo specimens demonstrated that coronary CT angiography and intravascular US are reasonably associated with plaque composition and lesion grading according to histopathologic findings, while OFDI was strongly associated. These data may help to develop initial concepts of sequential imaging strategies to identify patients with advanced coronary plaques.


Asunto(s)
Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico , Tomografía de Coherencia Óptica/métodos , Tomografía Computarizada por Rayos X/métodos , Ultrasonografía Intervencional/métodos , Cadáver , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Índice de Severidad de la Enfermedad
6.
J Cell Mol Med ; 15(2): 220-31, 2011 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-20015201

RESUMEN

Mutations of the ENPP1 gene encoding ecto-nucleotide pyrophosphatase/phosphodiesterase 1 (NPP1) are associated with medial calcification in infancy. While the inhibitory role of matrix proteins such as osteopontin (OPN) with respect to atherosclerotic plaque calcification has been established, the role of NPP1 in plaque calcification is not known. We assessed the degree of plaque calcification (computed tomography), NPP1 and OPN localization (immunohistochemistry) and expression (RT-PCR) in a cohort of 45 patients undergoing carotid endatherectomy for significant stenosis of the internal carotid artery and in normal arteries (N= 50). We correlated NPP1 and OPN expression levels to the degree of plaque calcification, to pro-atherogenic factors and statin therapy. NPP1 was demonstrated in the base and in the shoulder of atherosclerotic plaques. Compared to normal arteries and non-calcified plaques, in calcified plaques NPP1 mRNA was decreased (P < 0.0001). OPN mRNA levels were up-regulated in carotid atheroma. NPP1 and OPN expression levels positively correlated with the degree of plaque calcification (R= 0.54, P= 0.00019 and R= 0.46, P= 0.017, respectively) and with risk factors of atherosclerosis. Expression of the calcification inhibitor NPP1 is down-regulated in calcified atherosclerotic plaques. Our correlation data point to a counter-active mechanism, which in the end turns out to be insufficient to prevent further progression of calcification.


Asunto(s)
Arterias Carótidas/metabolismo , Hidrolasas Diéster Fosfóricas/genética , Hidrolasas Diéster Fosfóricas/metabolismo , Placa Aterosclerótica/metabolismo , Pirofosfatasas/genética , Pirofosfatasas/metabolismo , Calcificación Vascular/metabolismo , Anciano , Anciano de 80 o más Años , Aterosclerosis/metabolismo , Enfermedades de las Arterias Carótidas/metabolismo , Estenosis Carotídea/metabolismo , Regulación hacia Abajo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Músculo Liso Vascular/metabolismo , Osteopontina/biosíntesis , Osteopontina/genética , Hidrolasas Diéster Fosfóricas/biosíntesis , Placa Aterosclerótica/genética , Pirofosfatasas/biosíntesis , ARN Mensajero/biosíntesis
7.
Eur Radiol ; 20(12): 2817-23, 2010 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-20677007

RESUMEN

OBJECTIVE: Hyperintense areas in atherosclerotic plaques on pre-contrast T1-weighted MRI have been shown to correlate with intraplaque haemorrhage. We evaluated the presence of T1 hyperintensity in coronary artery plaques in coronary artery disease (CAD) patients and correlated results with multi-detector computed tomography (MDCT) findings. METHODS: Fifteen patients with CAD were included. Plaques detected by MDCT were categorised based on their Hounsfield number. T1-weighted inversion recovery (IR) MRI prepared coronary MRI for the detection of plaque and steady-state free-precession coronary MR-angiography for anatomical correlation was performed. After registration of MDCT and MRI, regions of interest were defined on MDCT-visible plaques and in corresponding vessel segments acquired with MRI. MDCT density and MR signal measurement were performed in each plaque. RESULTS: Forty-three plaques were identified with MDCT. With IR-MRI 5/43 (12%) plaques were hyperintense, 2 of which were non-calcified and 3 mixed. Average signal-to-noise and contrast-to-noise ratios of hyperintense plaques were 15.7 and 9.1, compared with 5.6 and 1.2 for hypointense plaques. Hyperintense plaques exhibited a significantly lower CT density than hypointense plaques (63.6 vs. 140.8). There was no correlation of plaque signal intensity with degree of stenosis. CONCLUSION: T1-weighted IR-MRI may be useful for non-invasive detection and characterisation of intraplaque haemorrhage in coronary artery plaques.


Asunto(s)
Estenosis Coronaria/complicaciones , Estenosis Coronaria/diagnóstico , Hemorragia/diagnóstico , Imagen por Resonancia Magnética/métodos , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tomografía Computarizada por Rayos X
8.
AJR Am J Roentgenol ; 194(2): 299-303, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-20093587

RESUMEN

OBJECTIVE: Multiple use of syringes in automatic injectors is considered to place patients at risk of septic complications. The purpose of this study was to evaluate the microbiologic contamination and time efficiency associated with routine clinical use of single-use prefilled disposable syringes for contrast administration. SUBJECTS AND METHODS: To ensure a hygienic background, imprints of devices and the palms of the hands of staff members were microbiologically analyzed before the clinical investigation. The microbiologic contamination of prefilled contrast and saline syringes was analyzed according to two protocols: single use of prefilled contrast syringes and saline syringes (n = 60) and single use of prefilled contrast syringes but multiple use of saline syringes for four injections or patients (n = 60). The time required for assembly of the injection system and filling and refilling for each protocol was measured. RESULTS: Contamination of the surfaces of devices and palms in the CT department was within the acceptable range for hygienic conditions. Prefilled disposable syringes for the contrast agent and saline solution used once had no microbiologic contamination. Microbial contamination with coagulase-negative staphylococci was found in two saline syringes used repeatedly. The time for assembly of the injection system and installation of prefilled syringes did not differ significantly (p = 0.45) between the single-use protocol (2.3 +/- 1.1 minutes) and the multiple-use protocol (2.0 +/- 1.4 minutes). CONCLUSION: Use of prefilled contrast syringes with single-use saline syringes is associated with time-efficient assembly of injection systems and prevents microbiologic contamination in clinical routine, especially in the care of immunocompromised patients.


Asunto(s)
Bacterias/aislamiento & purificación , Contaminación de Equipos , Control de Infecciones/normas , Yohexol/análogos & derivados , Jeringas/microbiología , Tomografía Computarizada por Rayos X/instrumentación , Medios de Contraste/administración & dosificación , Eficiencia , Diseño de Equipo , Análisis de Falla de Equipo , Mano/microbiología , Humanos , Inyecciones/instrumentación , Yohexol/administración & dosificación , Factores de Tiempo
9.
J Comput Assist Tomogr ; 34(4): 564-9, 2010 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-20657226

RESUMEN

OBJECTIVE: Comparison of 2-dimensional and semiautomated 3-dimensional (3D) measurements to distinguish between benign and malignant lymph nodes in patients with malignant lymphoma. METHODS: Whole-body positron emission tomography-computed tomography (PET-CT) was performed in 33 patients before therapy for malignant lymphoma. Two hundred fifty-seven peripheral lymph nodes (mean size, 13.4 +/- 5.4 mm) were evaluated independently by 2 radiologists, both manually and with the use of semiautomated segmentation software. Long-axis diameter (LAD), short-axis diameter (SAD), maximal 3D diameter, volume, and elongation were measured. Positron emission tomography-CT and PET-CT follow-up and/or histology served as the reference standard. Statistical analysis encompassed intraclass correlation coefficients and receiver operating characteristic curves. RESULTS: The standard of reference revealed involvement in 116 (45%) of 257 lymph nodes. Manual and semiautomated LAD and SAD showed good correlation with intraclass coefficients of 0.85 and 0.72, respectively. Semiautomated prediction of malignant lymph nodes revealed the highest areas under the receiver operating characteristic curves for volume (0.760; 95% confidence interval [CI], 0.639-0.887) followed by SAD (0.740; 95% CI, 0.616-0.862). The findings for LAD (0.722; 95% CI, 0.588-0.855), maximal 3D diameter (0.697; 95% CI, 0.565-0.830), and lymph node elongation (0.605; 95% CI, 0.466-0.745) were significantly lower (P < 0.05). CONCLUSIONS: Volumetric lymph node analysis is significantly superior compared with established LAD in the prediction of lymph node involvement and therefore can add to the definition of peripheral lymphoma target lesions.


Asunto(s)
Ganglios Linfáticos/diagnóstico por imagen , Linfoma/diagnóstico por imagen , Tomografía de Emisión de Positrones/métodos , Tomografía Computarizada por Rayos X/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Tomografía Computarizada de Haz Cónico/métodos , Medios de Contraste , Diagnóstico Diferencial , Femenino , Humanos , Imagenología Tridimensional/métodos , Yohexol/análogos & derivados , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Curva ROC , Intensificación de Imagen Radiográfica/métodos , Reproducibilidad de los Resultados , Imagen de Cuerpo Entero/métodos , Adulto Joven
10.
Eur Radiol ; 19(1): 42-9, 2009 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-18682956

RESUMEN

The aim of this study was to test a large sample of the latest coronary artery stents using four image reconstruction approaches with respect to lumen visualization, lumen attenuation, and image noise in dual-source multidetector row CT (DSCT) in vitro and to provide a CT catalogue of currently used coronary artery stents. Twenty-nine different coronary artery stents (19 steel, 6 cobalt-chromium, 2 tantalum, 1 iron, 1 magnesium) were examined in a coronary artery phantom (vessel diameter 3 mm, intravascular attenuation 250 HU, extravascular density -70 HU). Stents were imaged in axial orientation with standard parameters: 32 x 0.6 collimation, pitch 0.24, 400 mAs, 120 kV, rotation time 0.33 s. Image reconstructions were obtained with four different convolution kernels (soft, medium-soft, standard high-resolution, stent-dedicated). To evaluate visualization characteristics of the stent, the lumen diameter, intraluminal density, and noise were measured. The stent-dedicated kernel offered best average lumen visualization (54 +/- 8.3%) and most realistic lumen attenuation (222 +/- 44 HU) at the expense of increased noise (23.9 +/- 1.9 HU) compared with standard CTA protocols (p < 0.001 for all). The magnesium stent showed the least artifacts with a lumen visibility of 90%. The majority of stents (79%) exhibited a lumen visibility of 50-59%. Less than half of the stent lumen was visible in only six stents. Stent lumen visibility largely varies depending on the stent type. Magnesium is by far more favorable a stent material with regard to CT imaging when compared with the more common materials steel, cobalt-chromium, or tantalum. The magnesium stent exhibits a lumen visibility of 90%, whereas the majority of the other stents exhibit a lumen visibility of 50-59%.


Asunto(s)
Prótesis Vascular , Vasos Coronarios/cirugía , Análisis de Falla de Equipo/métodos , Stents , Tomografía Computarizada por Rayos X/métodos , Angiografía Coronaria/métodos , Diseño de Equipo , Humanos , Técnicas In Vitro , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/instrumentación
11.
Eur Radiol ; 19(10): 2373-82, 2009 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-19424699

RESUMEN

The aim of this study was to determine whether individually tailored protocols for the injection of contrast medium (CM) result in higher and more homogeneous vascular attenuation throughout the coronary arteries at coronary CT angiography compared with conventional injection protocols using fixed injection parameters. Of 120 patients included in the study, 80 patients were randomized into two groups. Group 1 received 80 mL of CM at 6 mL/s. For group 2 injection parameters were individually adjusted to patient weight, the duration of CT data acquisition, and attenuation parameters following a test bolus. In the control group (group 3) the volume of CM was adjusted to the duration of CT data acquisition and injected at 5 mL/s. Attenuation was measured in the proximal, middle, and distal right coronary artery (RCA), in the proximal and middle left anterior descending artery (LAD), and in cranial and caudal sections of both ventricles. Patient parameters, scan delay, and scan duration did not differ significantly between the groups. Mean CM volume was 82.5 mL (flow rate 5.1 mL/s) in group 2 and 73.5 mL in group 3. Attenuation in both RCA and LAD was significantly higher for group 2 vs. group 3 (RCA: 414.9 + or - 49.9)-396.1(+ or - 52.1) HU vs. 366.0(+ or - 64.3)-341.6(+ or - 72.5) HU; LAD: 398.9(+ or - 48.6)-364.6(+ or - 44.6) HU vs. 356.3(+ or - 69.5)-323.0(+ or - 67.2) HU). For group 1 vs. group 2 only attenuation in the distal RCA differed significantly: 396.1(+ or - 52.1) vs. 370.7(+ or - 70.5) HU. Individually tailored CM injection protocols yield higher attenuation, especially in the distal segments of the coronary vessels, compared with injection protocols using fixed injection parameters.


Asunto(s)
Medios de Contraste/administración & dosificación , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Yohexol/análogos & derivados , Intensificación de Imagen Radiográfica/métodos , Tomografía Computarizada por Rayos X/métodos , Femenino , Humanos , Inyecciones Intraarteriales , Yohexol/administración & dosificación , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
12.
AJR Am J Roentgenol ; 190(2): 308-14, 2008 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-18212214

RESUMEN

OBJECTIVE: The purpose of this study was to evaluate software for threshold-based 3D segmentation of the left ventricle in comparison with traditional 2D short axis-based planimetry (Simpson method) for measurement of left ventricular (LV) volume and global function with state-of-the-art dual-source CT. SUBJECTS AND METHODS: Fifty patients with known or suspected coronary artery disease underwent coronary CT angiography. LV end-diastolic, end-systolic, and stroke volumes and ejection fraction were determined from axial images to which 3D segmentation had been applied and from short-axis reformations from 2D planimetry. Interobserver variability was assessed for both approaches. RESULTS: Threshold-based 3D LV segmentation had excellent correlation with 2D short-axis results (end-diastolic volume, R = 0.99; end-systolic volume, R = 0.99; stroke volume, R = 0.90; ejection fraction, R = 0.97; p < 0.0001). Bland-Altman analyses revealed systematic underestimation of LV end-diastolic volume (-7.4 +/- 8.9 mL) and LV end-systolic volume (-7.0 +/- 4.4 mL) with the 3D segmentation approach and 2.8 +/- 3.3% overestimation of LV ejection fraction. Interobserver variation with 3D segmentation analysis was significantly (p < 0.001) less (e.g., LV ejection fraction, 0.1 +/- 1.7%) than with the 2D technique, and mean analysis time was significantly shorter (172 +/- 20 vs 248 +/- 29 seconds; p < 0.05). CONCLUSION: Automated threshold-based 3D segmentation enables accurate and reproducible dual-source CT assessment of LV volume and function with excellent correlation with results of 2D short-axis analysis. Exclusion of papillary muscles from LV volume results in small systematic differences in quantitative values.


Asunto(s)
Inteligencia Artificial , Imagenología Tridimensional/métodos , Reconocimiento de Normas Patrones Automatizadas/métodos , Intensificación de Imagen Radiográfica/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Disfunción Ventricular Izquierda/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Algoritmos , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/instrumentación , Disfunción Ventricular Izquierda/etiología
13.
AJR Am J Roentgenol ; 189(6): 1317-23, 2007 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-18029865

RESUMEN

OBJECTIVE: The purpose of this study was to determine the position of the optimal systolic and diastolic reconstruction intervals for coronary CT angiography using dual-source CT. SUBJECTS AND METHODS: In 90 patients, coronary dual-source CT angiography was performed without beta-blocking agents. Data were reconstructed in 5% steps throughout the R-R interval. Two independent readers selected optimal systolic and diastolic reconstruction windows for each major coronary vessel--the right coronary artery (RCA), left anterior descending artery (LAD), and left circumflex artery (LCX)--using a 3D viewer and volume-rendering displays. The motion score for each vessel was graded from 1 (no motion artifacts) to 5 (severe motion artifacts over entire vessel). RESULTS: The average heart rate of all patients was 68.7 beats per minute (bpm) (range, 43-119 bpm). The median optimal systolic reconstruction windows were at 35%, 30%, and 35% for the RCA, LAD, and LCX, respectively. The median optimal diastolic reconstruction window was at 75% for all vessels. The mean motion scores (+/- SD) in the systolic reconstructions were 1.9 +/- 0.8 (RCA), 1.7 +/- 0.5 (LAD), and 2.0 +/- 0.6 (LCX). The mean motion scores for the diastolic reconstructions were 1.7 +/- 0.9, 1.5 +/- 0.6, and 1.6 +/- 0.7, respectively. In patients with a heart rate of < 70 bpm, motion scores were significantly lower in diastole versus systole (1.3 +/- 0.4 and 1.9 +/- 0.5, respectively; p < 0.01). In most patients with a heart rate of > 80 bpm, motion scores were lower in systolic than in diastolic reconstructions (2.1 +/- 0.6 and 2.6 +/- 0.8, respectively; p < 0.05). CONCLUSION: Using dual-source CT, the overall optimal reconstruction window is at 75% of the R-R interval in patients with low or intermediate heart rates. In patients with heart rates of > 80 bpm, systolic reconstructions often yield superior image quality compared with diastolic reconstructions.


Asunto(s)
Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Intensificación de Imagen Radiográfica/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Disfunción Ventricular Izquierda/diagnóstico por imagen , Anciano , Enfermedad de la Arteria Coronaria/complicaciones , Diástole , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Sístole , Disfunción Ventricular Izquierda/etiología
14.
Invest Radiol ; 41(1): 22-7, 2006 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-16355036

RESUMEN

OBJECTIVES: We sought to assess the visualization of different coronary artery stents and the delineation of in-stent stenoses using 64- and 16-slice multidector computed tomography (MDCT). MATERIALS AND METHODS: A total of 15 different coronary stents with a simulated in-stent stenosis were placed in a vascular phantom and scanned with a 16-slice and a 64-slice MDCT at orientations of 0 degree, 45 degrees, and 90 degrees relative to the scanner's z-axis. Visible lumen diameter and attenuation in the stented and the unstented segment of the phantom were measured. Three readers assessed stenosis delineation and visualization of the residual lumen using a 5-point scale. RESULTS: Artificial lumen narrowing (ALN) was significantly reduced with 64-slice CT compared with 16-slice CT. At an angle of 0 degree, 45 degrees, and 90 degrees relative to the scanner's z-axis, the ALN for 16-slice CT was 42.2%, 39.8%, and 44.0% using a slice-thickness of 1.0 mm and 40.9%, 40.4%, and 41.6% using a slice thickness of 0.75 mm, respectively. With 64-slice CT, the ALN was 39.1%, 37.3%, and 36.0% at the respective angles. The differences between attenuation values in the stented and unstented segment of the tube were significantly lower for 64-slice CT. Mean visibility scores were significantly higher for 64-slice CT. CONCLUSION: Use of the 64-slice CT results in superior visualization of the stent lumen and in-stent stenosis compared with 16-slice CT, especially when the stent is orientated parallel to the x-ray beam.


Asunto(s)
Angiografía Coronaria/métodos , Estenosis Coronaria/diagnóstico por imagen , Oclusión de Injerto Vascular/diagnóstico por imagen , Radiografía Intervencional , Stents , Tomografía Computarizada por Rayos X/métodos , Estenosis Coronaria/cirugía , Procesamiento de Imagen Asistido por Computador , Técnicas In Vitro , Fantasmas de Imagen , Estadísticas no Paramétricas
15.
Invest Radiol ; 41(12): 898-903, 2006 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-17099429

RESUMEN

OBJECTIVE: We sought to evaluate an electrocardiogram (ECG)-independent image reconstruction technique for coronary computed tomography (CT)-angiography based on cardiac motion. MATERIALS AND METHODS: The raw data from 20 patients was reconstructed with both an ECG-gated algorithm and a motion-dependent algorithm that calculates the cardiac motion-function directly from the CT raw data using a center of mass technique. Images were reconstructed in 5% steps over the R-R interval and the cardiac motion-cycle. For both approaches multiplanar reformations were created and the set of images with the least motion artifacts was used for the evaluation. Motion artifacts affecting the ascending aorta, the left main coronary artery and the entire course of the LAD, LCX and RCA were scored using a 5-point scale. RESULTS: The mean optimal reconstruction window was at 60% of the R-R interval and 30% of the cardiac motion cycle. A total of 73 of 100 vascular regions showed no motion artifacts in ECG-gated images, with the motion-synchronized algorithm only 41 regions were free of motion artifacts. The mean motion-score was 1.4 (+/-0.6) and 2.4 (+/-1.2) respectively (P < 0.05). CONCLUSION: In the currently implemented form the motion-gated algorithm is inferior to ECG-gated image reconstruction but can be used in patients with an incomplete or corrupt ECG-signal.


Asunto(s)
Algoritmos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Movimiento (Física) , Contracción Miocárdica , Tomografía Computarizada por Rayos X , Artefactos , Electrocardiografía , Frecuencia Cardíaca , Humanos , Interpretación de Imagen Asistida por Computador/normas , Control de Calidad , Tomografía Computarizada por Rayos X/métodos
16.
AJR Am J Roentgenol ; 186(6 Suppl 2): S371-8, 2006 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-16714611

RESUMEN

OBJECTIVE: Determination of left ventricular (LV) volumes and global function parameters from MDCT data sets is usually based on short-axis reformations from primarily reconstructed axial images, which prolong postprocessing time. The aim of this study was to evaluate the feasibility of LV volumetry and global LV function assessment from axial images in comparison with short-axis image reformations. SUBJECTS AND METHODS: This study consisted of 20 patients with either coronary artery disease or dilated cardiomyopathy. We evaluated MDCT results using cine MRI as the reference technique. RESULTS: LV end-diastolic volume (LVEDV) and end-systolic volume (LVESV) were significantly overestimated by the axial MDCT approach in comparison with volume measurements from short-axis CT image reformations. The mean LV ejection fraction (LVEF) was not significantly different (41.2% vs 42.7%). Short-axis and axial MDCT determination of LVEF revealed a systematic underestimation by a mean +/- SD of -2.1% +/- 3.6% versus -3.6% +/- 8.2%, respectively, when compared with LVEF values based on cine MRI. The interobserver variability for volume and function measurements from axial images (LVEDV = 8.5%, LVESV = 10.8%, LVEF = 9.6%) was slightly higher than those measurements from short-axis reformations (LVEDV = 7.2%, LVESV = 9.5%, LVEF = 8.7%). The mean total evaluation time was significantly shorter using axial images (14.1 +/- 3.9 min) compared with short-axis reformations (16.9 +/- 5.2 min) (p < 0.05). CONCLUSION: Determination of LV volumes and assessment of global LV function from axial MDCT image reformations is feasible and time efficient. This approach might be a clinically useful alternative to established short-axis-based measurements in patients with normal or near-normal LV function. A progressive underestimation of LVEF with increasing LV volumes may limit the clinical applicability of the axial approach in patients with dilated cardiomyopathy.


Asunto(s)
Cardiomiopatía Dilatada/diagnóstico por imagen , Cardiomiopatía Dilatada/fisiopatología , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/fisiopatología , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/patología , Tomografía Computarizada por Rayos X , Función Ventricular Izquierda , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tamaño de los Órganos , Tomografía Computarizada por Rayos X/métodos
17.
Invest Radiol ; 38(12): 790-5, 2003 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-14627897

RESUMEN

OBJECTIVE: The aim of this study was to compare the visualization of different coronary artery stents and the detectability of in-stent stenoses during 4-slice and 16-slice computed tomography (CT) angiography in a vessel phantom. MATERIAL AND METHODS: Ten coronary stents were introduced in a coronary artery vessel phantom (plastic tubes with an inner diameter of 3 mm, filled with iodinated contrast material diluted to 220 Hounsfiled Units [HU], surrounded by oil [60 HU]). CT scans were obtained perpendicular to the stent axes on a 4-slice scanner (detector collimation 4x1 mm; table feed 1.5 mm/rotation, mAs 300, kV 120, medium-smooth kernel) and a 16-slice scanner (detector collimation 12x0.75 mm; table feed 2.8 mm/rotation, mAs 370, kV 120, reconstruction with a standard and an optimized sharp kernel). Longitudinal multiplanar reformations were evaluated regarding visible lumen diameters and intraluminal attenuation values. Additionally, the stents were scanned with the same parameters after implantation of 60% stenoses (HU 30). RESULTS: Using the same medium-smooth kernel reconstruction with 4-slice and 16-slice CT, there was a slight increase in the average visible lumen area (26% versus 31%) and less increase of average intraluminal attenuation values (380 HU versus 349 HU). Significant improvement of lumen visualization (54%, P<0.01) and attenuation values (250, P<0.01) was observed for the 16-slice scans using the sharp kernel reconstruction. In-stent stenoses could be more reliably identified (or ruled out) by 16-slice CT and sharp reconstruction kernel when compared with the other 2 methods. CONCLUSION: 16-slice CT using a dedicated sharp kernel for image reconstruction facilitates improved visualization of coronary artery stent lumen and detection of in-stent stenoses.


Asunto(s)
Estenosis Coronaria/diagnóstico por imagen , Oclusión de Injerto Vascular/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Angiografía Coronaria/métodos , Estenosis Coronaria/cirugía , Procesamiento de Imagen Asistido por Computador/métodos , Fantasmas de Imagen , Stents
18.
J Cardiovasc Comput Tomogr ; 8(6): 452-8, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25467832

RESUMEN

BACKGROUND: Elevated levels of inflammatory biomarkers are associated with increased cardiovascular morbidity and mortality. OBJECTIVE: We sought to determine whether elevated concentrations of high-sensitivity troponin T (hs-TnT) and high-sensitivity C-reactive protein (hs-CRP) predict progression of coronary artery disease (CAD) as determined by coronary CT angiography (coronary CTA). METHODS: Patients presenting to the emergency department with acute chest pain who initially showed no evidence of an acute coronary syndrome underwent baseline and follow-up coronary CTA (median follow-up, 23.9 months) using identical acquisition and reconstruction parameters. Coronary CTA data of each major coronary artery were co-registered. Cross-sections were assessed for the presence of calcified and noncalcified plaques. Progression of atherosclerotic plaque and change of plaque composition from noncalcified to calcified plaque was evaluated and correlated to levels of hs-TnT and hs-CRP at the time of the baseline CT. RESULTS: Fifty-four patients (mean age, 54.1 years; 59% male) were included, and 6775 cross-sections were compared. CAD was detected in 12.2 ± 21.2 cross-sections per patient at baseline. Prevalence of calcified plaque increased by 1.5 ± 2.4 slices per patient (P < .0001) over the follow-up period. On average, 1.6 ± 3.6 slices with new noncalcified plaque were found per patient (P < .0001) and 0.7 ± 1.7 slices with pre-existing noncalcified plaque had progressed to calcified plaque (P < .0001). After multivariate adjustment, change of overall CAD burden was predicted by baseline hs-TnT and hs-CRP (r = 0.29; P = .039 and r = 0.40; P = .004). Change of plaque composition was associated with baseline hs-TnT (r = 0.29; P = .03). CONCLUSION: Concentrations of hs-TnT and hs-CRP are weakly associated with a significant increase in CAD burden and change in plaque composition over 24 months independent of baseline risk factors.


Asunto(s)
Proteína C-Reactiva/análisis , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico , Vasos Coronarios/diagnóstico por imagen , Placa Aterosclerótica , Tomografía Computarizada por Rayos X , Troponina T/sangre , Calcificación Vascular/diagnóstico , Adulto , Anciano , Biomarcadores/sangre , Enfermedad de la Arteria Coronaria/sangre , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/epidemiología , Progresión de la Enfermedad , Femenino , Alemania , Humanos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Valor Predictivo de las Pruebas , Prevalencia , Estudios Prospectivos , Factores de Riesgo , Factores de Tiempo , Regulación hacia Arriba , Calcificación Vascular/sangre , Calcificación Vascular/diagnóstico por imagen , Calcificación Vascular/epidemiología
19.
Acad Radiol ; 20(8): 1015-23, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23830607

RESUMEN

RATIONALE AND OBJECTIVES: Numerous protocols have been developed to reduce cardiac computed tomography angiography (cCTA) radiation dose while maintaining image quality. However, cCTA practice is highly dependent on physician and technologist experience and education. In this study, we sought to evaluate the incremental value of real-time feedback via weekly dose reports on a busy cCTA service. MATERIALS AND METHODS: This time series analysis consisted of 450 consecutive patients whom underwent physician-supervised cCTA for clinically indicated native coronary evaluation between April 2011 and January 2013, with 150 patients before the initiation of weekly dose report (preintervention period: April-September 2011) and 150 patients after the initiation (postintervention period: September 2011-February 2012). To assess whether overall dose reductions were maintained over time, results were compared to a late control group consisting of 150 consecutive cCTA exams, which were performed after the study (September 2012-January 2013). Patient characteristics and effective radiation were recorded and compared. RESULTS: Total radiation dose was significantly lower in the postintervention period (3.4 mSv [1.7-5.7] and in the late control group (3.3 mSv [2.0-5.3] versus the preintervention period (4.1 mSv [2.1-6.6] (P = .005). The proportion of high-dose outliers was also decreased in the postintervention period and late control period (exams <10 mSv were 88.0% preintervention vs. 97.3% postintervention vs. 95.3% late control; exams <15 mSv were 98.0% preintervention vs. 100.0% postintervention vs. 98.7% late control; exams <20.0 mSv were 98.7% preintervention vs. 100.0% postintervention vs. 100.0% late control). CONCLUSION: Weekly dose report feedback of site radiation doses to patients undergoing physician-supervised cCTA resulted in significant overall dose reduction and reduction of high-dose outliers. Overall dose reductions were maintained beyond the initial study period.


Asunto(s)
Angiografía Coronaria/estadística & datos numéricos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/epidemiología , Mejoramiento de la Calidad/estadística & datos numéricos , Dosis de Radiación , Centros de Atención Terciaria/estadística & datos numéricos , Tomografía Computarizada por Rayos X/estadística & datos numéricos , Angiografía Coronaria/normas , Femenino , Humanos , Masculino , Massachusetts/epidemiología , Persona de Mediana Edad , Prevalencia , Protección Radiológica , Radiometría/normas , Radiometría/estadística & datos numéricos , Reproducibilidad de los Resultados , Medición de Riesgo , Sensibilidad y Especificidad , Centros de Atención Terciaria/normas , Tomografía Computarizada por Rayos X/normas
20.
J Cardiovasc Comput Tomogr ; 7(4): 215-22, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-24148775

RESUMEN

BACKGROUND: Despite continuous improvements in CT technology, accurate stent lumen delineation remains challenging. PURPOSE: The aim was to evaluate the quality of coronary stent lumen delineation with CT using a detector with integrated electronics. METHODS: Twelve coronary stents placed in plastic tubes and filled with contrast agent (CT number 250 HU) were imaged with either a 128-section dual-source CT machine equipped with conventional detector or with integrated electronics. On both scanners, images were reconstructed with filtered back projection (slice thickness 0.6 mm; increment 0.4 mm) and sinogram-affirmed iterative reconstruction (slice thickness 0.6 mm; increment 0.4 mm), and with iterative reconstruction (slice thickness 0.5 mm; increment 0.3 mm) on the integrated scanner. Two blinded, independent readers assessed image quality, noise, in-stent diameter, in-stent attenuation, and image sharpness by using signal intensity profiles across stents. RESULTS: Interreader agreement for image quality assessment was substantial (κ = 0.798). Both readers rated best image quality in data sets from integrated detector at highest spatial resolution (86 or 72% of stents rated best quality). Image noise was significantly lower in data sets scanned with integrated detector, being lowest at 0.6 mm slice thickness (14.3 vs 21.0 HU; P < .001). Differences between measured and true in-stent diameters and differences in attenuation across stents were smallest, and average/maximum image sharpness was highest in data sets from the integrated detector using iterative reconstructions. CONCLUSION: CT coronary stent imaging is significantly improved by using a detector with integrated electronics combined with iterative reconstructions.


Asunto(s)
Angiografía Coronaria/instrumentación , Vasos Coronarios/diagnóstico por imagen , Modelos Cardiovasculares , Tomografía Computarizada Multidetector/instrumentación , Interpretación de Imagen Radiográfica Asistida por Computador , Stents , Tomógrafos Computarizados por Rayos X , Artefactos , Angiografía Coronaria/métodos , Diseño de Equipo , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Diseño de Prótesis , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS