Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo de estudio
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Phys Rev Lett ; 131(25): 256504, 2023 Dec 22.
Artículo en Inglés | MEDLINE | ID: mdl-38181357

RESUMEN

An ultrasharp photoluminescence line intimately related to antiferromagnetic order has been found in NiPS_{3}, a correlated van der Waals material, opening prospects for magneto-optical coupling schemes and spintronic applications. Here we unambiguously clarify the singlet origin of this excitation, confirming its roots in the spin structure. Based on a comprehensive investigation of the electronic structure using angle-resolved photoemission and q-dependent electron energy loss spectroscopy as experimental tools we develop, in a first step, an adequate theoretical understanding using density functional theory (DFT). In a second step the DFT is used as input for a dedicated multiplet theory by which we achieve excellent agreement with available multiplet spectroscopy. Our Letter connects the understanding of the electronic structure and of optical processes in NiPS_{3} and related materials as a prerequisite for further progress of the field.

2.
J Comput Assist Tomogr ; 4(5): 642-8, 1980 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-7410644

RESUMEN

Silver iodide colloid was used as a model of a particulate hepatic contrast agent for computed tomography (CT). Following intravenous administration to rabbits, approximately 90% of the injected dose was phagocytized by the liver's reticuloendothelial system, resulting in a four- to five-fold increase in the liver CT number. Suspensions of CeO2, Dy2O3, and Gd2O3 were prepared using stabilizers to prevent clumping. Particles of appropriate size for reticuloendothelial cell uptake were selected by centrifugation. Intravenous injections of the three suspensions increased the CT number of rabbit liver by approximately 30 Hounsfield units (HU: 1,000 scale) for each experimental contrast agent resulted in a minimum addition of 250 HU to the liver CT number. A linear relationship was found between the CT number and its contrast material concentration. This relationship was also tested in vitro by ashing samples of livers containing various amounts of contrast material. Standard curves of CT number versus contrast material concentration in the liver were plotted, which predicted the amount of liver enhancement obtained after contrast material injection. There may be a use for heavy metal-containing particulate materials as hepatic contrast agents, since they opacify the liver more selectively, to a higher degree, and for longer periods than the conventional biliary and urographic iodinated contrast materials.


Asunto(s)
Medios de Contraste , Hígado/diagnóstico por imagen , Metales de Tierras Raras , Tomografía Computarizada por Rayos X , Animales , Cerio , Disprosio , Gadolinio , Yoduros , Hígado/metabolismo , Óxidos , Tamaño de la Partícula , Conejos , Plata
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA