Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Anaesthesist ; 59(2): 135-9, 2010 Feb.
Artículo en Alemán | MEDLINE | ID: mdl-20151103

RESUMEN

BACKGROUND: The outcome of cardiopulmonary resuscitation (CPR) depends on the quality of chest compressions. Current European Resuscitation Council (ERC) guidelines promote the development of feedback systems. However, no studies presenting satisfactory results of feedback use have been published. METHODS: A total of 60 patients with cardiac arrest (> or =18 years of age) received resuscitation attempts using an automated external defibrillator (AED) with real-time feedback by the ambulance service of the City of Münster. The frequency of chest compressions, no-flow time (NFT) and depth of chest compressions were analyzed for the first three cycles of CPR and compared to the ERC guidelines 2005. RESULTS: Chest compression frequency did not differ significantly from the ideal as set out in the guidelines. Analysis of NFTs showed significantly longer NFT for the first cycle but NFT for the second and third cycles did not differ significantly from the ideal. The target depth of 4-5 cm was achieved in 80% of all chest compressions in the first 3 cycles. CONCLUSION: With the AED real-time feedback technology used in this study standardized performance of chest compressions could be maintained in a professional ambulance service. Implementation of a feedback system requires training of ambulance staff.


Asunto(s)
Reanimación Cardiopulmonar/instrumentación , Reanimación Cardiopulmonar/normas , Adulto , Anciano , Anciano de 80 o más Años , Algoritmos , Reanimación Cardiopulmonar/estadística & datos numéricos , Cardioversión Eléctrica , Electrocardiografía , Europa (Continente) , Retroalimentación , Femenino , Guías como Asunto , Paro Cardíaco/terapia , Humanos , Masculino , Persona de Mediana Edad , Mecánica Respiratoria , Programas Informáticos , Tórax
2.
J Clin Neurosci ; 16(1): 79-82, 2009 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-19017557

RESUMEN

The reported sensitivity of neurovascular ultrasound (nUS) for detecting spontaneous cervical artery dissection (sCAD) varies from 80% to 96% in the internal carotid artery (ICA) and from 70% to 86% in the vertebral arteries (VA). The aim of this study was to assess the sensitivity of nUS compared to MRI of the neck and MR angiography for the detection of sCAD. Forty consecutive patients with sCAD proven by 1.5T MRI were investigated by nUS within 48 hours of admission. A total of 52 cases of sCAD were detected by MRI, equally distributed (n=26, 50%) in the ICA and VA territories. Two sCADs affecting the ICA (n=2, 8%) and two sCADs of the VA (n=2, 8%) had normal initial nUS findings. The sensitivity of nUS in detecting sCAD is high, about 92% for both vascular territories. However, intramural hematomas may be missed either when they are located outside the arterial segments directly visible by nUS or if they are too small to cause hemodynamically significant stenosis.


Asunto(s)
Disección de la Arteria Carótida Interna/diagnóstico por imagen , Arteria Carótida Interna/diagnóstico por imagen , Ultrasonografía Doppler Dúplex/métodos , Disección de la Arteria Vertebral/diagnóstico por imagen , Arteria Vertebral/diagnóstico por imagen , Adulto , Anciano , Disección de la Arteria Carótida Interna/patología , Femenino , Humanos , Angiografía por Resonancia Magnética , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Sensibilidad y Especificidad , Disección de la Arteria Vertebral/patología , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA