1.
Magn Reson Med ; 89(1): 29-39, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36063499

RESUMEN

PURPOSE: To explore the potential of deuterium metabolic imaging (DMI) in the human brain in vivo at 7 T, using a multi-element deuterium (2 H) RF coil for 3D volume coverage. METHODS: 1 H-MR images and localized 2 H MR spectra were acquired in vivo in the human brain of 3 healthy subjects to generate DMI maps of 2 H-labeled water, glucose, and glutamate/glutamine (Glx). In addition, non-localized 2 H-MR spectra were acquired both in vivo and in vitro to determine T1 and T2 relaxation times of deuterated metabolites at 7 T. The performance of the 2 H coil was assessed through numeric simulations and experimentally acquired B1 + maps. RESULTS: 3D DMI maps covering the entire human brain in vivo were obtained from well-resolved deuterated (2 H) metabolite resonances of water, glucose, and Glx. The T1 and T2 relaxation times were consistent with those reported at adjacent field strengths. Experimental B1 + maps were in good agreement with simulations, indicating efficient and homogeneous B1 + transmission and low RF power deposition for 2 H, consistent with a similar array coil design reported at 9.4 T. CONCLUSION: Here, we have demonstrated the successful implementation of 3D DMI in the human brain in vivo at 7 T. The spatial and temporal nominal resolutions achieved at 7 T (i.e., 2.7 mL in 28 min, respectively) were close to those achieved at 9.4 T and greatly outperformed DMI at lower magnetic fields. DMI at 7 T and beyond has clear potential in applications dealing with small brain lesions.


Asunto(s)
Encéfalo , Imagenología Tridimensional , Humanos , Deuterio , Encéfalo/diagnóstico por imagen , Encéfalo/metabolismo , Imagenología Tridimensional/métodos , Glucosa/metabolismo , Agua , Imagen por Resonancia Magnética/métodos
2.
NMR Biomed ; 32(12): e4171, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31517419

RESUMEN

In vivo 13 C MRS at high field benefits from an improved SNR and spectral resolution especially when using surface coils in combination with adiabatic pulses, such as the adiabatic half-passage (AHP) pulse for 13 C excitation. However, the excitation profile of the AHP pulse is asymmetric relative to the carrier frequency, which could lead to asymmetric excitation of the spectral lines relative to the center of the spectrum. In this study, a pulse-acquire sequence was designed for adiabatic 13 C excitation with a symmetric bandwidth, utilizing a combination of two AHP pulses with inverted phases in alternate scans. Magnetization and phase behavior as a function of frequency offset and RF amplitude of the B1 field, as well as the steady-state transverse magnetization response to off-resonance, were simulated. Excitation properties of the combined pulse sequence were studied by 23 Na imaging and 13 C spectroscopy in vitro on a phantom and in vivo on the human calf at 7 T. Simulations demonstrated symmetric transverse magnetization and phase with respect to positive and negative frequency offsets when using two AHP pulses with inverted phases in alternate scans, thereby minimizing baseline distortion and achieving symmetric T1 weighting, as confirmed by in vitro measurements. The intensities of the lipid peaks at 15, 30, 62, 73, and 130 ppm were in agreement with those theoretically predicted using two AHP pulses with inverted phases in alternate scans. We conclude that using two phase-inverted AHP pulses improves the symmetry of the 13 C excitation profile and phase response to off-resonance effects at 7 T in comparison with using a single AHP pulse.


Asunto(s)
Espectroscopía de Resonancia Magnética con Carbono-13 , Simulación por Computador , Humanos , Masculino , Músculos/diagnóstico por imagen , Protones , Sodio/química
3.
Magn Reson Med ; 73(2): 894-900, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24590906

RESUMEN

PURPOSE: Carbon-13 magnetic resonance spectroscopy ((13) C-MRS) is challenging because of the inherent low sensitivity of (13) C detection and the need for radiofrequency transmission at the (1) H frequency while receiving the (13) C signal, the latter requiring electrical decoupling of the (13) C and (1) H radiofrequency channels. In this study, we added traps to the (13) C coil to construct a quadrature-(13) C/quadrature-(1) H surface coil, with sufficient isolation between channels to allow simultaneous operation at both frequencies without compromise in coil performance. METHODS: Isolation between channels was evaluated on the bench by measuring all coupling parameters. The quadrature mode of the quadrature-(13) C coil was assessed using in vitro (23) Na gradient echo images. The signal-to-noise ratio (SNR) was measured on the glycogen and glucose resonances by (13) C-MRS in vitro, compared with that obtained with a linear-(13) C/quadrature-(1) H coil, and validated by (13) C-MRS in vivo in the human calf at 7T. RESULTS: Isolation between channels was better than -30 dB. The (23) Na gradient echo images indicate a region where the field is strongly circularly polarized. The quadrature coil provided an SNR enhancement over a linear coil of 1.4, in vitro and in vivo. CONCLUSION: It is feasible to construct a double-quadrature (13) C-(1) H surface coil for proton decoupled sensitivity enhanced (13) C-NMR spectroscopy in humans at 7T.


Asunto(s)
Glucógeno/análisis , Magnetismo/instrumentación , Músculo Esquelético/química , Espectroscopía de Protones por Resonancia Magnética/instrumentación , Adulto , Isótopos de Carbono/análisis , Isótopos de Carbono/química , Diseño de Equipo , Análisis de Falla de Equipo , Estudios de Factibilidad , Humanos , Masculino , Protones , Ondas de Radio , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Distribución Tisular
4.
Magn Reson Med ; 72(2): 584-90, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24006123

RESUMEN

PURPOSE: Multinuclear magnetic resonance spectroscopy and imaging require a radiofrequency probe capable of transmitting and receiving at the proton and non-proton frequencies. To minimize coupling between probe elements tuned to different frequencies, LC (inductor-capacitor) traps blocking current at the (1)H frequency can be inserted in non-proton elements. This work compares LC traps with LCC traps, a modified design incorporating an additional capacitor, enabling control of the trap reactance at the low frequency while maintaining (1)H blocking. METHODS: Losses introduced by both types of trap were analysed using circuit models. Radiofrequency coils incorporating a series of LC and LCC traps were then built and evaluated at the bench. LCC trap performance was then confirmed using (1)H and (13)C measurements in a 7T human scanner. RESULTS: LC and LCC traps both effectively block interaction between non-proton and proton coils at the proton frequency. LCC traps were found to introduce a sensitivity reduction of 5±2%, which was less than half of that caused by LC traps. CONCLUSION: Sensitivity of non-proton coils is critical. The improved trap design, incorporating one extra capacitor, significantly reduces losses introduced by the trap in the non-proton coil.


Asunto(s)
Aumento de la Imagen/instrumentación , Imagen por Resonancia Magnética/instrumentación , Magnetismo/instrumentación , Transductores , Diseño Asistido por Computadora , Diseño de Equipo , Análisis de Falla de Equipo , Aumento de la Imagen/métodos , Imagen por Resonancia Magnética/métodos , Magnetismo/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad