Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Nat Methods ; 9(9): 889-95, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22936170

RESUMEN

We discuss unique features of lens-free computational imaging tools and report some of their emerging results for wide-field on-chip microscopy, such as the achievement of a numerical aperture (NA) of ∼0.8-0.9 across a field of view (FOV) of more than 20 mm(2) or an NA of ∼0.1 across a FOV of ∼18 cm(2), which corresponds to an image with more than 1.5 gigapixels. We also discuss the current challenges that these computational on-chip microscopes face, shedding light on their future directions and applications.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/instrumentación , Procesamiento de Imagen Asistido por Computador/métodos , Microscopía/instrumentación , Microscopía/métodos , Algoritmos , Eritrocitos/citología , Humanos , Lentes , Masculino , Espermatozoides/citología
2.
Proc Natl Acad Sci U S A ; 108(18): 7296-301, 2011 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-21504943

RESUMEN

We present a lens-free optical tomographic microscope, which enables imaging a large volume of approximately 15 mm(3) on a chip, with a spatial resolution of < 1 µm × < 1 µm × < 3 µm in x, y and z dimensions, respectively. In this lens-free tomography modality, the sample is placed directly on a digital sensor array with, e.g., ≤ 4 mm distance to its active area. A partially coherent light source placed approximately 70 mm away from the sensor is employed to record lens-free in-line holograms of the sample from different viewing angles. At each illumination angle, multiple subpixel shifted holograms are also recorded, which are digitally processed using a pixel superresolution technique to create a single high-resolution hologram of each angular projection of the object. These superresolved holograms are digitally reconstructed for an angular range of ± 50°, which are then back-projected to compute tomograms of the sample. In order to minimize the artifacts due to limited angular range of tilted illumination, a dual-axis tomography scheme is adopted, where the light source is rotated along two orthogonal axes. Tomographic imaging performance is quantified using microbeads of different dimensions, as well as by imaging wild-type Caenorhabditis elegans. Probing a large volume with a decent 3D spatial resolution, this lens-free optical tomography platform on a chip could provide a powerful tool for high-throughput imaging applications in, e.g., cell and developmental biology.


Asunto(s)
Holografía/instrumentación , Microscopía/instrumentación , Tomografía/instrumentación , Animales , Caenorhabditis elegans/ultraestructura
3.
Eur Rev Med Pharmacol Sci ; 28(12): 3822-3827, 2024 06.
Artículo en Inglés | MEDLINE | ID: mdl-38946379

RESUMEN

OBJECTIVE: A condition known as ligamentum flavum (LF) hypertrophy occurs when the ligamentum flavum (LF) swells as a result of pressures applied to the spine. Among the elderly population, lumbar spinal stenosis is a major cause of pain and disabilities. Numerous studies indicate that lumbar spinal stenosis etiology involves the ligamentum flavum in a major way. This study looks into the relationship between low back pain and ligamentum flavum thickening. PATIENTS AND METHODS: The imaging tests and case histories of all patients with low back pain who had consecutive magnetic resonance imaging exams performed at the Prince Sattam University and King Khalid hospitals in Al Kharj City will serve as the basis for this retrospective observational study. A radiologist utilized the Pfirrmann grading system, which is based on spinal levels starting from the first lumbar to the first sacral vertebrae, to measure the thickness of the ligamentum flavum in all cases who underwent magnetic resonance imaging (MRI). A correlation between age, hypertrophy of LF, and low back pain was investigated. RESULTS: There were 79 participants in the study, ages ranging from 21 to 82, 49 of which were men. The patients' average age was 54 years, and 62% of them were men. We found no appreciable variations in LF thickness according to gender. At the L4-L5 and L5-S1 levels, the left LF was noticeably thicker than the right. Moreover, there was a significant difference (p < 0.05) in the bilateral LF thicknesses at L5-S1 compared to the comparable sides at L4-L5. CONCLUSIONS: By evaluating the thickness of LF on magnetic resonance images, we discovered that it may be closely associated with the etiology of pain processes in the spine.


Asunto(s)
Hipertrofia , Ligamento Amarillo , Dolor de la Región Lumbar , Imagen por Resonancia Magnética , Humanos , Ligamento Amarillo/patología , Ligamento Amarillo/diagnóstico por imagen , Dolor de la Región Lumbar/diagnóstico por imagen , Dolor de la Región Lumbar/patología , Dolor de la Región Lumbar/etiología , Masculino , Persona de Mediana Edad , Femenino , Anciano , Estudios Retrospectivos , Adulto , Anciano de 80 o más Años , Adulto Joven , Vértebras Lumbares/diagnóstico por imagen , Vértebras Lumbares/patología , Estenosis Espinal/diagnóstico por imagen , Estenosis Espinal/patología
4.
IEEE J Sel Top Quantum Electron ; 18(3): 1059-1072, 2011 Jul 11.
Artículo en Inglés | MEDLINE | ID: mdl-24478572

RESUMEN

Lensfree on-chip holographic microscopy is an emerging technique that offers imaging of biological specimens over a large field-of-view without using any lenses or bulky optical components. Lending itself to a compact, cost-effective and mechanically robust architecture, lensfree on-chip holographic microscopy can offer an alternative toolset addressing some of the emerging needs of microscopic analysis and diagnostics in low-resource settings, especially for telemedicine applications. In this review, we summarize the latest achievements in lensfree optical microscopy based on partially coherent on-chip holography, including portable telemedicine microscopy, cell-phone based microscopy and field-portable optical tomographic microscopy. We also discuss some of the future directions for telemedicine microscopy and its prospects to help combat various global health challenges.

5.
Appl Opt ; 50(34): H253-64, 2011 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-22193016

RESUMEN

Optical sectioning of biological specimens provides detailed volumetric information regarding their internal structure. To provide a complementary approach to existing three-dimensional (3D) microscopy modalities, we have recently demonstrated lensfree optical tomography that offers high-throughput imaging within a compact and simple platform. In this approach, in-line holograms of objects at different angles of partially coherent illumination are recorded using a digital sensor-array, which enables computing pixel super-resolved tomographic images of the specimen. This imaging modality, which forms the focus of this review, offers micrometer-scale 3D resolution over large imaging volumes of, for example, 10-15 mm(3), and can be assembled in light weight and compact architectures. Therefore, lensfree optical tomography might be particularly useful for lab-on-a-chip applications as well as for microscopy needs in resource-limited settings.


Asunto(s)
Holografía/instrumentación , Microscopía/instrumentación , Tomografía Óptica/instrumentación , Algoritmos , Holografía/métodos , Procesamiento de Imagen Asistido por Computador , Microscopía/métodos , Tomografía Óptica/métodos
6.
Lab Chip ; 10(14): 1787-92, 2010 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-20445943

RESUMEN

We demonstrate lensfree digital microscopy on a cellphone. This compact and light-weight holographic microscope installed on a cellphone does not utilize any lenses, lasers or other bulky optical components and it may offer a cost-effective tool for telemedicine applications to address various global health challenges. Weighing approximately 38 grams (<1.4 ounces), this lensfree imaging platform can be mechanically attached to the camera unit of a cellphone where the samples are loaded from the side, and are vertically illuminated by a simple light-emitting diode (LED). This incoherent LED light is then scattered from each micro-object to coherently interfere with the background light, creating the lensfree hologram of each object on the detector array of the cellphone. These holographic signatures captured by the cellphone permit reconstruction of microscopic images of the objects through rapid digital processing. We report the performance of this lensfree cellphone microscope by imaging various sized micro-particles, as well as red blood cells, white blood cells, platelets and a waterborne parasite (Giardia lamblia).


Asunto(s)
Teléfono Celular , Holografía/instrumentación , Aumento de la Imagen/instrumentación , Iluminación/instrumentación , Microscopía/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo , Lentes , Semiconductores
7.
Lab Chip ; 10(9): 1109-12, 2010 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-20390127

RESUMEN

We demonstrate color and monochrome on-chip imaging of Caenorhabditis elegans samples over a wide field-of-view using incoherent lensless in-line holography. Digital reconstruction of the recorded lensless holograms rapidly creates the C. elegans images within <1 s over a field-of-view of >24 mm2. By digitally combining the reconstructed images at three different wavelengths (red, green and blue), color images of dyed samples are also acquired. This wide field-of-view and compact on-chip imaging modality also permits straightforward integration with microfluidic systems.


Asunto(s)
Caenorhabditis elegans/citología , Colorimetría/instrumentación , Holografía/instrumentación , Aumento de la Imagen/instrumentación , Técnicas Analíticas Microfluídicas/instrumentación , Microscopía/instrumentación , Procesamiento de Señales Asistido por Computador/instrumentación , Animales , Diseño de Equipo , Análisis de Falla de Equipo , Lentes , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
8.
Lab Chip ; 10(11): 1417-28, 2010 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-20401422

RESUMEN

Despite the rapid progress in optical imaging, most of the advanced microscopy modalities still require complex and costly set-ups that unfortunately limit their use beyond well equipped laboratories. In the meantime, microscopy in resource-limited settings has requirements significantly different from those encountered in advanced laboratories, and such imaging devices should be cost-effective, compact, light-weight and appropriately accurate and simple to be usable by minimally trained personnel. Furthermore, these portable microscopes should ideally be digitally integrated as part of a telemedicine network that connects various mobile health-care providers to a central laboratory or hospital. Toward this end, here we demonstrate a lensless on-chip microscope weighing approximately 46 grams with dimensions smaller than 4.2 cm x 4.2 cm x 5.8 cm that achieves sub-cellular resolution over a large field of view of approximately 24 mm(2). This compact and light-weight microscope is based on digital in-line holography and does not need any lenses, bulky optical/mechanical components or coherent sources such as lasers. Instead, it utilizes a simple light-emitting-diode (LED) and a compact opto-electronic sensor-array to record lensless holograms of the objects, which then permits rapid digital reconstruction of regular transmission or differential interference contrast (DIC) images of the objects. Because this lensless incoherent holographic microscope has orders-of-magnitude improved light collection efficiency and is very robust to mechanical misalignments it may offer a cost-effective tool especially for telemedicine applications involving various global health problems in resource limited settings.


Asunto(s)
Holografía/instrumentación , Lentes , Iluminación/instrumentación , Microfluídica/instrumentación , Microscopía/instrumentación , Telemedicina/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo , Miniaturización
9.
Anal Chem ; 82(11): 4621-7, 2010 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-20450181

RESUMEN

We present a detailed investigation of the performance of lens-free holographic microscopy toward high-throughput on-chip blood analysis. Using a spatially incoherent source that is emanating from a large aperture, automated counting of red blood cells with minimal sample preparation steps at densities reaching up to approximately 0.4 x 10(6) cells/muL is presented. Using the same lens-free holographic microscopy platform, we also characterize the volume of the red blood cells at the single-cell level through recovery of the optical phase information of each cell. We further demonstrate the measurement of the hemoglobin concentration of whole blood samples as well as automated counting of white blood cells, also yielding spatial resolution at the subcellular level sufficient to differentiate granulocytes, monocytes, and lymphocytes from each other. These results uncover the prospects of lens-free holographic on-chip imaging to provide a useful tool for global health problems, especially by facilitating whole blood analysis in resource-poor environments.


Asunto(s)
Recuento de Células Sanguíneas/instrumentación , Dispositivos Laboratorio en un Chip , Recuento de Células Sanguíneas/métodos , Recuento de Eritrocitos , Holografía , Humanos , Lentes , Recuento de Leucocitos , Microscopía , Factores de Tiempo
10.
Opt Express ; 18(5): 4717-26, 2010 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-20389485

RESUMEN

We introduce the use of a birefringent crystal with lensless digital holography to create an on-chip differential interference contrast (DIC) microscope. Using an incoherent source with a large aperture, in-line holograms of micro-objects are created, which interact with a uniaxial crystal and an absorbing polarizer, encoding differential interference contrast information of the objects on the chip. Despite the fact that a unit fringe magnification and an incoherent source with a large aperture have been used, holographic digital processing of such holograms rapidly recovers the differential phase contrast image of the specimen over a large field-of-view of approximately 24 mm(2).

11.
Opt Express ; 18(9): 9690-711, 2010 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-20588819

RESUMEN

A multi-angle lensfree holographic imaging platform that can accurately characterize both the axial and lateral positions of cells located within multi-layered micro-channels is introduced. In this platform, lensfree digital holograms of the micro-objects on the chip are recorded at different illumination angles using partially coherent illumination. These digital holograms start to shift laterally on the sensor plane as the illumination angle of the source is tilted. Since the exact amount of this lateral shift of each object hologram can be calculated with an accuracy that beats the diffraction limit of light, the height of each cell from the substrate can be determined over a large field of view without the use of any lenses. We demonstrate the proof of concept of this multi-angle lensless imaging platform by using light emitting diodes to characterize various sized microparticles located on a chip with sub-micron axial and lateral localization over approximately 60 mm(2) field of view. Furthermore, we successfully apply this lensless imaging approach to simultaneously characterize blood samples located at multi-layered micro-channels in terms of the counts, individual thicknesses and the volumes of the cells at each layer. Because this platform does not require any lenses, lasers or other bulky optical/mechanical components, it provides a compact and high-throughput alternative to conventional approaches for cytometry and diagnostics applications involving lab on a chip systems.


Asunto(s)
Diagnóstico por Imagen/instrumentación , Diagnóstico por Imagen/métodos , Holografía/instrumentación , Holografía/métodos , Lentes , Eritrocitos/citología , Humanos , Reproducibilidad de los Resultados
12.
Opt Express ; 17(19): 17179-89, 2009 Sep 14.
Artículo en Inglés | MEDLINE | ID: mdl-19770937

RESUMEN

A two-degrees-of-freedom scanned beam imaging system with large dynamic range and dynamic focusing is demonstrated. The laser diode, photo-detector and the optical components are integrated on a moving platform that is made of FR4 (Flame-Retardant 4), a common polymeric substrate used in printed circuit boards. A scan angle of 52 degrees is demonstrated at 60 Hz resonant frequency while the laser is moved 250 um in the out-of-plane direction to achieve dynamic focusing. The laser is scanned by physically rotating the laser diode and the collection optics to achieve high signal-to-noise ratio and good ambient light rejection. The collection optics is engineered such that the collection efficiency decreases when collecting light from close distances to avoid detector saturation. The detection range is extended from contact distance up to 600 mm while the collected power level varies only by a factor of 30 within this long range. Slight modifications will allow increasing the detection range up to one meter. This is the first demonstration of a laser scan engine with such a high degree of integration of electronics, optoelectronics, optics and micromechanics on the same platform.

13.
Saudi J Biol Sci ; 26(6): 1107-1111, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31516336

RESUMEN

The aims of the present work were to quantify radiation doses arises from patients' exposure in mammographic X-ray imaging procedures and to estimate the radiation induced cancer risk. Sixty patients were evaluated using a calibrated digital mammography unit at King Khaled Hospital and Prince Sultan Center, Alkharj, Saudi Arabia. The average patient age (years) was 44.4 ±â€¯10 (26-69). The average and range of exposure parameters were 29.1 ±â€¯1.9 (24.0-33.0) and 78.4 ±â€¯17.5 (28.0-173.0) for X-ray tube potential (kVp) and current multiplied by the exposure time (s) (mAs), respectively. The MGD (mGy) per single projection for craniocaudal (CC), Medio lateral oblique (MLO) and lateromedial (LM) was 1.02 ±â€¯0.2 (0.4-1.8), 1.1 ±â€¯0.3 (0.5-1.8), 1.1 ±â€¯0.3 (0.5-1.9) per procedure, in that order. The average cancer risk per projection is 177 per million procedures. The cancer risk is significant during multiple image acquisition. The study revealed that 80% of the procedures with normal findings. However, precise justification is required especially for young patients.

14.
Appl Radiat Isot ; 141: 261-265, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-30054177

RESUMEN

Patient effective doses and the associated radiation risks arising from particular computed tomography (CT) imaging procedures are assessed. The objectives of this research are to measure radiation doses for patients and to quantify the radiogenic risks from CT brain and chest procedures. Patient data were collected from five calibrated CT modality machines in Saudi Arabia. The results are from a study of a total of 60 patients examined during CT procedures using the calibrated CT units. For CT brain and chest, the mean patient effective doses were 1.9 mSv (with a range of 0.6-2.5 mSv) and 7.4 mSv (with a range of 0.5-34.8 mSv) respectively. The radiogenic risk to patients ranged from between 10-5 and 10-4 per procedure. With 65% of the CT procedure cases diagnosed as normal, this prompts re-evaluation of the referral criteria. The establishment of diagnostic reference levels (DRL) and implementation of radiation dose optimisation measures would further help reduce doses to optimal values.


Asunto(s)
Tomografía Computarizada por Rayos X/efectos adversos , Tomografía Computarizada por Rayos X/métodos , Adulto , Encéfalo/diagnóstico por imagen , Calibración , Femenino , Humanos , Masculino , Neoplasias Inducidas por Radiación/etiología , Neoplasias Inducidas por Radiación/prevención & control , Dosis de Radiación , Exposición a la Radiación/prevención & control , Traumatismos por Radiación/etiología , Traumatismos por Radiación/prevención & control , Protección Radiológica , Arabia Saudita , Tórax/diagnóstico por imagen , Tomografía Computarizada por Rayos X/normas
15.
Lab Chip ; 13(1): 51-67, 2013 Jan 07.
Artículo en Inglés | MEDLINE | ID: mdl-23044793

RESUMEN

Improving access to effective and affordable healthcare has long been a global endeavor. In this quest, the development of cost-effective and easy-to-use medical testing equipment that enables rapid and accurate diagnosis is essential to reduce the time and costs associated with healthcare services. To this end, point-of-care (POC) diagnostics plays a crucial role in healthcare delivery in both developed and developing countries by bringing medical testing to patients, or to sites near patients. As the diagnosis of a wide range of diseases, including various types of cancers and many endemics, relies on optical techniques, numerous compact and cost-effective optical imaging platforms have been developed in recent years for use at the POC. Here, we review the state-of-the-art optical imaging techniques that can have a significant impact on global health by facilitating effective and affordable POC diagnostics.


Asunto(s)
Imagen Óptica/instrumentación , Imagen Óptica/métodos , Sistemas de Atención de Punto , Salud Global , Humanos
16.
Stud Health Technol Inform ; 185: 299-323, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23542940

RESUMEN

The recent revolution in digital technologies and information processing methods present important opportunities to transform the way optical imaging is performed, particularly toward improving the throughput of microscopes while at the same time reducing their relative cost and complexity. Lensfree computational microscopy is rapidly emerging toward this end, and by discarding lenses and other bulky optical components of conventional imaging systems, and relying on digital computation instead, it can achieve both reflection and transmission mode microscopy over a large field-of-view within compact, cost-effective and mechanically robust architectures. Such high throughput and miniaturized imaging devices can provide a complementary toolset for telemedicine applications and point-of-care diagnostics by facilitating complex and critical tasks such as cytometry and microscopic analysis of e.g., blood smears, Papanicolaou (Pap) tests and tissue samples. In this article, the basics of these lensfree microscopy modalities will be reviewed, and their clinically relevant applications will be discussed.


Asunto(s)
Citodiagnóstico/métodos , Citometría de Imagen/métodos , Aumento de la Imagen/métodos , Microscopía/métodos , Sistemas de Atención de Punto , Análisis de Matrices Tisulares/métodos , Citodiagnóstico/instrumentación , Citometría de Imagen/instrumentación , Aumento de la Imagen/instrumentación , Lentes , Miniaturización , Análisis de Matrices Tisulares/instrumentación
17.
Ann Biomed Eng ; 40(2): 251-62, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21887590

RESUMEN

Microfluidic devices aim at miniaturizing, automating, and lowering the cost of chemical and biological sample manipulation and detection, hence creating new opportunities for lab-on-a-chip platforms. Recently, optofluidic devices have also emerged where optics is used to enhance the functionality and the performance of microfluidic components in general. Lensfree imaging within microfluidic channels is one such optofluidic platform, and in this article, we focus on the holographic implementation of lensfree optofluidic microscopy and tomography, which might provide a simpler and more powerful solution for three-dimensional (3D) on-chip imaging. This lensfree optofluidic imaging platform utilizes partially coherent digital in-line holography to allow phase and amplitude imaging of specimens flowing through micro-channels, and takes advantage of the fluidic flow to achieve higher spatial resolution imaging compared to a stationary specimen on the same chip. In addition to this, 3D tomographic images of the same samples can also be reconstructed by capturing lensfree projection images of the samples at various illumination angles as a function of the fluidic flow. Based on lensfree digital holographic imaging, this optofluidic microscopy and tomography concept could be valuable especially for providing a compact, yet powerful toolset for lab-on-a-chip devices.


Asunto(s)
Técnicas Analíticas Microfluídicas , Microscopía/métodos , Tomografía/métodos , Animales , Holografía/instrumentación , Holografía/métodos , Microscopía/instrumentación , Tomografía/instrumentación
18.
J Vis Exp ; (66): e4161, 2012 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-22929176

RESUMEN

Tomographic imaging has been a widely used tool in medicine as it can provide three-dimensional (3D) structural information regarding objects of different size scales. In micrometer and millimeter scales, optical microscopy modalities find increasing use owing to the non-ionizing nature of visible light, and the availability of a rich set of illumination sources (such as lasers and light-emitting-diodes) and detection elements (such as large format CCD and CMOS detector-arrays). Among the recently developed optical tomographic microscopy modalities, one can include optical coherence tomography, optical diffraction tomography, optical projection tomography and light-sheet microscopy. These platforms provide sectional imaging of cells, microorganisms and model animals such as C. elegans, zebrafish and mouse embryos. Existing 3D optical imagers generally have relatively bulky and complex architectures, limiting the availability of these equipments to advanced laboratories, and impeding their integration with lab-on-a-chip platforms and microfluidic chips. To provide an alternative tomographic microscope, we recently developed lensfree optical tomography (LOT) as a high-throughput, compact and cost-effective optical tomography modality. LOT discards the use of lenses and bulky optical components, and instead relies on multi-angle illumination and digital computation to achieve depth-resolved imaging of micro-objects over a large imaging volume. LOT can image biological specimen at a spatial resolution of <1 µm x <1 µm x <3 µm in the x, y and z dimensions, respectively, over a large imaging volume of 15-100 mm(3), and can be particularly useful for lab-on-a-chip platforms.


Asunto(s)
Microscopía/instrumentación , Microscopía/métodos , Tomografía Óptica/instrumentación , Tomografía Óptica/métodos , Animales , Caenorhabditis elegans
19.
J Biomed Opt ; 17(12): 126018, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23235893

RESUMEN

Endothelial cells cultured in three-dimensional (3-D) extracellular matrices spontaneously form microvessels in response to soluble and matrix-bound factors. Such cultures are common for the study of angiogenesis and may find widespread use in drug discovery. Vascular networks are imaged over weeks to measure the distribution of vessel morphogenic parameters. Measurements require micron-scale spatial resolution, which for light microscopy comes at the cost of limited field-of-view (FOV) and shallow depth-of-focus (DOF). Small FOVs and DOFs necessitate lateral and axial mechanical scanning, thus limiting imaging throughput. We present a lens-free holographic on-chip microscopy technique to rapidly image microvessels within a Petri dish over a large volume without any mechanical scanning. This on-chip method uses partially coherent illumination and a CMOS sensor to record in-line holographic images of the sample. For digital reconstruction of the measured holograms, we implement a multiheight phase recovery method to obtain phase images of capillary morphogenesis over a large FOV (24 mm2) with ≈ 1.5 µm spatial resolution. On average, measured capillary length in our method was within approximately 2% of lengths measured using a 10 × microscope objective. These results suggest lens-free on-chip imaging is a useful toolset for high-throughput monitoring and quantitative analysis of microvascular 3-D networks.


Asunto(s)
Capilares/citología , Capilares/crecimiento & desarrollo , Células Endoteliales/citología , Holografía/instrumentación , Imagenología Tridimensional/instrumentación , Microscopía/instrumentación , Morfogénesis/fisiología , Células Endoteliales/fisiología , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Sensibilidad y Especificidad
20.
PLoS One ; 7(9): e45044, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22984606

RESUMEN

We report Giga-pixel lensfree holographic microscopy and tomography using color sensor-arrays such as CMOS imagers that exhibit Bayer color filter patterns. Without physically removing these color filters coated on the sensor chip, we synthesize pixel super-resolved lensfree holograms, which are then reconstructed to achieve ~350 nm lateral resolution, corresponding to a numerical aperture of ~0.8, across a field-of-view of ~20.5 mm(2). This constitutes a digital image with ~0.7 Billion effective pixels in both amplitude and phase channels (i.e., ~1.4 Giga-pixels total). Furthermore, by changing the illumination angle (e.g., ± 50°) and scanning a partially-coherent light source across two orthogonal axes, super-resolved images of the same specimen from different viewing angles are created, which are then digitally combined to synthesize tomographic images of the object. Using this dual-axis lensfree tomographic imager running on a color sensor-chip, we achieve a 3D spatial resolution of ~0.35 µm × 0.35 µm × ~2 µm, in x, y and z, respectively, creating an effective voxel size of ~0.03 µm(3) across a sample volume of ~5 mm(3), which is equivalent to >150 Billion voxels. We demonstrate the proof-of-concept of this lensfree optical tomographic microscopy platform on a color CMOS image sensor by creating tomograms of micro-particles as well as a wild-type C. elegans nematode.


Asunto(s)
Holografía/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Microscopía/métodos , Tomografía/métodos , Animales , Caenorhabditis elegans/anatomía & histología , Color , Holografía/instrumentación , Procesamiento de Imagen Asistido por Computador/instrumentación , Microscopía/instrumentación , Reproducibilidad de los Resultados , Tomografía/instrumentación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA