Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Asunto principal
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Optom Vis Sci ; 88(1): 130-9, 2011 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-20935585

RESUMEN

PURPOSE: To assess relations between perimetric sensitivity and neuroretinal rim area using high-resolution perimetric mapping in patients with glaucomatous defects within 10° of fixation. METHODS: One eye was tested in each of 31 patients with open-angle glaucoma enrolled in a prospective study of perimetric defects within 10° of fixation. Norms were derived from 110 control subjects free of eye disease, aged 21 to 81 years. Perimetric sensitivity was measured using the 10-2 test pattern with the Swedish Interactive Threshold Algorithm (SITA) standard algorithm on the Humphrey Field Analyzer (HFA) II-i; Carl Zeiss Meditec), stimulus size III. Area of the temporal neuroretinal rim was measured using the Heidelberg retina tomograph 3. Decibel values were converted into linear units of contrast sensitivity averaged across locations corresponding to the temporal rim sector. Both measures were expressed as percent of mean normal, and the Bland-Altman method was used to assess agreement. Perimetric locations corresponding to the temporal sector were determined for six different optic nerve maps. RESULTS: Contrast sensitivity was moderately correlated with temporal rim area (r2 >30%, p < 0.005). For all six optic nerve maps, Bland-Altman analysis found good agreement between perimetric sensitivity and rim area with both measures expressed as fraction of mean normal and confidence limits for agreement that were consistent with normal between-subject variability in control eyes. CONCLUSIONS: By using high-resolution perimetric mapping in patients with scotomas within 10° of fixation, we confirmed findings of linear relations between perimetric sensitivity and area of temporal neuroretinal rim and showed that the confidence limits for agreement in patients with glaucoma were consistent with normal between-subject variability.


Asunto(s)
Glaucoma/diagnóstico , Glaucoma/fisiopatología , Adulto , Anciano , Anciano de 80 o más Años , Algoritmos , Sensibilidad de Contraste , Femenino , Humanos , Masculino , Persona de Mediana Edad , Modelos Anatómicos , Nervio Óptico/fisiopatología , Estudios Prospectivos , Retina/patología , Escotoma/diagnóstico , Sensibilidad y Especificidad , Tomografía , Pruebas del Campo Visual , Adulto Joven
2.
Transl Vis Sci Technol ; 7(6): 7, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-30479878

RESUMEN

PURPOSE: We assessed the image quality and reproducibility of blood flow measurements from a novel handheld laser speckle imager in handheld and stabilized use cases. METHODS: Eleven dilated human subjects were imaged with the XyCAM Handheld Retinal Imager investigational device (XyCAM HRI) in the handheld and stabilized use case in nine consecutive imaging sessions. Subjects then underwent standard color fundus photography using a Topcon TRC 50DX. The vessel-to-background contrast of the XyCAM HRI red-free photo was compared to the fundus photograph, while the coefficient of variation of blood flow measurements in specific arteries and veins also was determined. RESULTS: Vessel-to-background contrast was statistically greater in the handheld use case when compared to the standard color fundus photographs (P = 0.01). Estimates of mean blood flow velocity (BFV) were highly correlated between the stabilized and handheld use case (r 2 = 0.96). Peak velocity estimates in arteries were significantly higher than those in veins (P < 0.05). CONCLUSIONS: The XyCAM HRI prototype can acquire fundus photographs with the same or better level of clarity as color fundus photographs, and reproducibly acquire functional blood flow information in the handheld use case. TRANSLATIONAL RELEVANCE: To our knowledge, this is the first human study of a handheld laser speckle retinal imaging device. Determination of retinal blood flow has applications to ophthalmic and systemic disease and a portable handheld retinal imager that determines blood flow may be widely adopted at the point of care.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA