Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
J Burn Care Res ; 33(5): 649-53, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22878495

RESUMEN

Approximately 100 operating room (OR) fires occur per year in the United States, with 15% resulting in serious injuries. Intraoperative cautery was frequently associated with OR fires before 1994; however, use of supplemental oxygen (O(2)), ethanol-based products, and disposable drapes have been more frequently associated with OR fires. Fires resulting from cosmetic and other small procedures involving use of nasal canula O(2) and electrocautery have been described in six published reports. We report five thermal injury cases admitted to our burn treatment center because of fires during surgical procedures over a 5-year period. Two patients undergoing supraorbital excision experienced 2.5 and 3% TBSA involvement burns; in a third patient surgical excision of a nasal polyp resulted in a 1% TBSA burn; in a fourth patient an excisional biopsy of a lymph node resulted in a 2.75% TBSA burn; and the last patient was burned during placement of a pacemaker, with resulting TBSA of 10.5%. Two of the five patients required intubation for inhalational injury. Two patients required tangential excision and grafting of their thermal injuries. All patients had received local or parenteral anesthesia with supplemental O(2)/nitrous oxide (N(2)O) for surgical procedure. There are a number of ignition sources in the OR, including electrocautery, lasers, and faulty OR equipment. The risk of OR fires increases with surgical procedures involving the face and neck, including tracheostomy and tracheobronchial surgery. The common use of O(2)/N(2)O mixtures or enriched O(2) for minimally complex surgical procedures and disposable drapes adds to the risk of an OR fire: the O(2)/N(2)O provides a fuel source, and the disposable drapes trap thedelivered gas. Electrocautery near an O(2)/N(2)O source resulted in the five thermal injuries and warrants careful reconsideration of technique for surgical procedures.


Asunto(s)
Unidades de Quemados , Quemaduras/cirugía , Incendios , Enfermedad Iatrogénica , Quirófanos , Adolescente , Adulto , Anciano , Quemaduras/etiología , Femenino , Hospitalización , Humanos , Masculino , Persona de Mediana Edad , Seguridad del Paciente , Factores de Riesgo , Estados Unidos , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA