RESUMEN
Household air pollution is a leading risk factor for morbidity and premature mortality. Numerous cookstoves have been developed to reduce household air pollution, but it is unclear whether such cookstoves meaningfully improve health. In a controlled exposure study with a crossover design, we assessed the effect of pollution emitted from multiple cookstoves on acute differences in blood lipids and inflammatory biomarkers. Participants (n = 48) were assigned to treatment sequences of exposure to air pollution emitted from five cookstoves and a filtered-air control. Blood lipids and inflammatory biomarkers were measured before and 0, 3, and 24 hours after treatments. Many of the measured outcomes had inconsistent results. However, compared to control, intercellular adhesion molecule-1 was higher 3 hours after all treatments, and C-reactive protein and serum amyloid-A were higher 24 hours after the highest treatment. Our results suggest that short-term exposure to cookstove air pollution can increase inflammatory biomarkers within 24 hours.
Asunto(s)
Contaminación del Aire Interior , Contaminación del Aire , Contaminación del Aire Interior/análisis , Biomarcadores , Culinaria , Humanos , LípidosRESUMEN
Household air pollution emitted from solid-fuel cookstoves used for domestic cooking is a leading risk factor for morbidity and premature mortality globally. There have been attempts to design and distribute lower emission cookstoves, yet it is unclear if they meaningfully improve health. Using a crossover design, we assessed differences in central aortic hemodynamics and arterial stiffness following controlled exposures to air pollution emitted from five different cookstove technologies compared to a filtered air control. Forty-eight young, healthy participants were assigned to six 2-h controlled treatments of pollution from five different cookstoves and a filtered air control. Each treatment had a target concentration for fine particulate matter: filtered air controlâ¯=â¯0⯵g/m3, liquefied petroleum gasâ¯=â¯10⯵g/m3, gasifierâ¯=â¯35⯵g/m3, fan rocketâ¯=â¯100⯵g/m3, rocket elbowâ¯=â¯250⯵g/m3, three stone fireâ¯=â¯500⯵g/m3. Pulse wave velocity (PWV), central augmentation index (AIx), and central pulse pressure (CPP) were measured before and at three time points after each treatment (0, 3, and 24â¯h). Linear mixed models were used to assess differences in the outcomes for each cookstove treatment compared to control. PWV and CPP were marginally higher 24â¯h after all cookstove treatments compared to control. For example, PWV was 0.15â¯m/s higher (95% confidence interval: -0.02, 0.31) and CPP was 0.6â¯mmHg higher (95% confidence interval: -0.8, 2.1) 24â¯h after the three stone fire treatment compared to control. The magnitude of the differences compared to control was similar across all cookstove treatments. PWV and CPP had no consistent trends at the other post-treatment time points (0 and 3â¯h). No consistent trends were observed for AIx at any post-treatment time point. Our findings suggest higher levels of PWV and CPP within 24â¯h after 2-h controlled treatments of pollution from five different cookstove technologies. The similar magnitude of the differences following each cookstove treatment compared to control may indicate that acute exposures from even the cleanest cookstove technologies can adversely impact these subclinical markers of cardiovascular health, although differences were small and may not be clinically meaningful.
Asunto(s)
Contaminación del Aire Interior , Contaminación del Aire , Análisis de la Onda del Pulso , Humo , Adulto , Presión Sanguínea , Culinaria , Femenino , Humanos , Masculino , Humo/efectos adversos , Voluntarios , Adulto JovenRESUMEN
Background: Exposure to household air pollution generated as a result of cooking and heating is a leading contributor to global disease. The effects of cookstove-generated air pollution on adult lung function, however, remain uncertain.Objectives: We investigated acute responses in lung function following controlled exposures to cookstove-generated air pollution.Methods: We recruited 48 healthy adult volunteers to undergo six two-hour treatments: a filtered-air control and emissions from five different stoves with fine particulate matter (PM2.5) targets from 10 to 500 µg/m3. Spirometry was conducted prior to exposure and immediately, and three and 24 h post-exposure. Mixed-effect models were used to estimate differences in post-exposure lung function for stove treatments versus control.Results: Immediately post-exposure, lung function was lower compared to the control for the three highest PM2.5-level stoves. The largest differences were for the fan rocket stove (target 250 µg/m3; forced vital capacity (FVC): -60 mL, 95% confidence interval (95% CI) -135, 15; forced expiratory volume (FEV1): -51 mL, 95% CI -117, 16; mid-expiratory flow (FEF25-75): -116 mL/s, 95% CI -239, 8). At 3 h post-exposure, lung function was lower compared to the control for all stove treatments; effects were of similar magnitude for all stoves. At 24 h post-exposure, results were consistent with a null association for FVC and FEV1; FEF25-75 was lower relative to the control for the gasifier, fan rocket, and three stone fire.Conclusions: Patterns suggesting short-term decreases in lung function follow from exposure to cookstove air pollution even for stove exposures with low PM2.5 levels.
Asunto(s)
Contaminación del Aire Interior/efectos adversos , Culinaria , Artículos Domésticos , Pulmón/fisiopatología , Humo/efectos adversos , Adulto , Volumen Espiratorio Forzado , Humanos , Flujo Espiratorio Medio Máximo , Espirometría , Capacidad Vital , Adulto JovenRESUMEN
Caffeine and its derivatives have been used, alone and in combination with other phytochemicals, as weight-loss supplements. Caffeine affects several physiological and behavioural aspects of energy balance, including increasing locomotor activity. This study investigates the potential for caffeine to enhance activity thermogenesis and energy expenditure (EE) even when activity level is held constant. To do this, EE and muscle thermogenesis were measured in rats during treadmill walking regimens, with and without caffeine (25 mg/kg, ip). Activity-related EE was significantly increased throughout the treadmill walking protocol. Muscle heat dissipation, on the other hand, was significantly increased by caffeine only at the end of the 25-minute treadmill test. This study demonstrates that caffeine increases the caloric cost of physical activity, compared to the caloric cost of that same physical activity without caffeine, implicating decreased muscle work efficiency. Combined with the known ability of caffeine to increase locomotor activity, the decreased locomotor efficiency imparted by caffeine may further augment the potential for caffeine to enhance caloric expenditure.
Asunto(s)
Cafeína/farmacología , Metabolismo Energético/efectos de los fármacos , Termogénesis/efectos de los fármacos , Tejido Adiposo Pardo/efectos de los fármacos , Tejido Adiposo Pardo/metabolismo , Animales , Ratas , Respiración/efectos de los fármacos , CaminataRESUMEN
Background Exposure to air pollution from solid fuel used in residential cookstoves is considered a leading environmental risk factor for disease globally, but evidence for this relationship is largely extrapolated from literature on smoking, secondhand smoke, and ambient fine particulate matter ( PM 2.5). Methods and Results We conducted a controlled human-exposure study (STOVES [the Subclinical Tests on Volunteers Exposed to Smoke] Study) to investigate acute responses in blood pressure following exposure to air pollution emissions from cookstove technologies. Forty-eight healthy adults received 2-hour exposures to 5 cookstove treatments (three stone fire, rocket elbow, fan rocket elbow, gasifier, and liquefied petroleum gas), spanning PM 2.5 concentrations from 10 to 500 µg/m3, and a filtered air control (0 µg/m3). Thirty minutes after exposure, systolic pressure was lower for the three stone fire treatment (500 µg/m3 PM 2.5) compared with the control (-2.3 mm Hg; 95% CI, -4.5 to -0.1) and suggestively lower for the gasifier (35 µg/m3 PM 2.5; -1.8 mm Hg; 95% CI , -4.0 to 0.4). No differences were observed at 3 hours after exposure; however, at 24 hours after exposure, mean systolic pressure was 2 to 3 mm Hg higher for all treatments compared with control except for the rocket elbow stove. No differences were observed in diastolic pressure for any time point or treatment. Conclusions Short-term exposure to air pollution from cookstoves can elicit an increase in systolic pressure within 24 hours. This response occurred across a range of stove types and PM 2.5 concentrations, raising concern that even low-level exposures to cookstove air pollution may pose adverse cardiovascular effects.